Transpo VRC2010 Regulator Tester PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 552
At a glance
Powered by AI
The document describes the features and operation of the VRC2010 voltage regulator tester.

The VRC2010 can test A and B circuit regulators at 12 and 24V, has a field circuit load, warning light circuit, dual stator output, buttons to identify active terminals and overvoltage functions.

The input connections on the left panel include Battery Pos, Battery Neg, STA1, STA2 and are used to connect to the regulator under test.

V o l t age Regul a t o r T e s t e r M a n u a l

VRC2010

June 2011
VRC2010 Features
z Test A and B Circuit, 12 and 24 Volt Alternator Regulators

z Test Field Circuit with 0.5A and 3.0A Loads @12Volt, 1A Loads @24Volt

z Warning Light Circuit to Simulate Vehicle Indicator Lamp for 12 and 24 Volt regulators

z Dual stator Output for Valeo type regulators and dual Frequency, replaces VRC101-34

z Push Button identify Active L-Terminal (Choke Drive)

z Push Button identify Presence of Over-Voltage Function

z Push Button C (Computer) type regulators

z Built in VRC101-31 Functions; enables test of F601 type regulators at 13 Volts, 14 Volts and 15 Volts

z 5 Volt lamp (LI) for F601 type application and also for PCM type lamp circuits driven from 5 Volts

z Built in “PD” tester to replace VRC101-26

z Lead Set and Test Manual Provided

z Universal power supply 47 – 63 Hz, 100 – 240 VAC and 3 amp fuse included

Page 1
VRC2010 Panel Description
z Choke Light: also called relay drive. Connects to negative inside, used to test active lamp driver
connections on 12 and 24 Volt regulators.

z Lamp: connected to Battery Positive inside tester, used to test lamp driver circuit for 12 and 24 Volt
regulators. Green color.

z Field Switch: to put tester in mode to test “A” type (low side drive) and “B” type (high side drive)
regulators. Yellow color.

z Stator: Switch enables setting frequency of stator from either 150Hz or 450Hz. White color.

z Comm. Voltage Switch: for Bss, LIN and RCV type regulators you can adjust the setpoint voltage to 13,
14 or 15 Volts.

z Choke Button: Push this button engages the Choke lamp circuit to test relay driver regulators.

z Overvoltage Button: push this button and the tester goes into an overvoltage condition and you can test
if regulator has OV lamp feature.

z Computer Button: push this button and the “C” connection is grounded, typically in this condition a “C”
type regulator setpoint voltage drops to about 12.8 Volts.

z DC Voltage Range Switch: This switch has three settings to control the tester. The 12V setting.puts a
low current 0.5 A load to the voltage regulator so you can check its setpoint voltage.The 12V, 3A setting
puts a three amp load onto the voltage regulator for test. The 24V setting puts a 1 A load on the regulator
and sets for testing 24 Volts regulators.

Page 2
VRC2010 Panel Input connections

z Left Panel Input connections


z Battery Pos: Connects to the battery connection of the regulator, also used to connect to the Sense, IGN
or Trio of the regulator. Also called B+, Positive, battery, power, Vcc. Connect DMM V+ for measuring
voltage. Red color.

z Battery Neg: Connects to the ground of the system, also called Negative, B-, GND, and Ground.
Connect DMM V- or COM for measuring voltage. Black color.

z STA1: Stator drive circuit also called phase. Provides either 150 or 450 HZ. White color.

z STA2: Same signal as STA1 except 180 degrees out of phase. Used for testing dual stator regulators.
White color.

z Right Panel Input connections


z LIN: Output connection to drive LIN based regulators, for example IB6056. Blue color.

z BSS: Output connection to drive BSS type regulators. Brown color.

z RCV: Output connection to drive Ford type Com regulators, for example F601HD. Gray color.

z LI: Load Indicator, this connects to the LI Led to verify the LI circuit of the regulator still works.The
brightness of the LI LED should change if the COMM Voltage Knob changes position. Gray color.

z PD: The drive circuit to test PD type voltage regulators. Orange color.

z C: connection for the “C” terminal of the voltage regulators. Common in many Import regulators. Purple
color.

z Battery Pos: Connects to the battery connection of the regulator when using the right panel input
connections. Red color.

z Battery Neg: Connects to the ground of the system when using the right panel input connections. Black
color.
Page 3
Example BSS or LIN type

x Connect (GND) to tester “BATTERY NEG”, Black.

x Connect (B+) to tester “POS”, Red.

x Connect (STATOR) to tester “STA1”, White.

x Connect (FIELD) to tester “Field”, Yellow.

x Connect (SENSE) to tester “POS”, Red.

x Connect (COM) to tester “LIN”, Blue Picture shows Transpo IB6056. For BSS
type connect (COM) to tester “BSS”.

x Turn switch to 12V setting.

x Set Field switch to “B” type.

x Turn on power switch on back of tester.

x Set comm. Voltage switch to desired Voltage and reading on display should
match within tolerance of the regulator.

Page 4
Example Transpo IM465HD (PD type):

x Connect (B-) to tester “BATTERY NEG”, Black.

x Connect (STATOR) to tester “STA1”, White.

x Connect (B+) to tester “POS”, Red.

x Connect (FIELD) to tester “Field”, Yellow.

x Connect (DRIVER) to tester “PD”, Orange.

x Turn switch to 12V setting or 12V, 3A setting.

x Set Field switch to “A” type.

x Set Stator switch to 150 HZ.

x Turn on power switch on back of tester.

x Voltage on display will be approximately 14.6 Volts for good regulator.

Page 5
Example Transpo IN220HD:

x Connect (B-) to tester “BATTERY NEG”, Black.

x Connect (STATOR) to tester “STA1”, White.

x Connect IGN, B+ and Sense to tester “POS”, Red.

x Connect (FIELD) to tester “Field”, Yellow.

x Connect (IL) to tester “LAMP”, Green.

x Turn switch to 12V setting.

x Set Field to “A” type.

x Set Stator switch to 450 HZ.

x Turn on power switch on back of tester.

x Voltage reads regulator setpoint of 14.5 Volts plus tolerance.

x Press Choke button and the Choke should come on.

x Disconnect Sense wire and the lamp will be on.

Page 6
IN224 ( C type)

x Connect (B-) to tester “BATTERY NEG”, Black.

x Connect (STATOR) to tester “STA1”, White.

x Connect B+and IGN to tester “POS”, Red.

x Connect (FIELD) to tester “Field”, Yellow.

x Connect (C) to tester “C”, Violet.

x Connect (IL) to tester “LAMP”, Green.

x Connect (FR) to tester “LI”, Grey.

x Turn switch to 12V setting.

x Set Field switch to “A” type.

x Set Stator switch to 450 HZ.

x Turn on power switch on back of tester.

x Voltage reads regulator setpoint of 14.5 Volts plus tolerance.

x Press “C” button and the setpoint voltage changes to 12.7 Volts.

Page 7
Example Transpo F601HD:

x Connect (B-) to tester “BATTERY NEG”, Black.

x Connect (STATOR) to tester “STA1”, White.

x Connect B+ and SENSE to tester “POS”, Red.

x Connect (FIELD) to tester “Field”, Yellow.

x Connect (RC) to tester “RCV”, Grey.

x Connect (LI) to tester “LI”, Grey.

x Turn switch to 12V setting.

x Set Field switch to “A” type.

x Set Stator switch to 450 HZ.

x Turn on power switch on back of tester.

x Set Comm Switch to desired Voltage and reading on display should match within
tolerance of the regulator.

Page 8
OPERATING INSTRUCTIONS FOR VRC2010

Set the field current switch to 0.5A for checking or setting the regulation voltage. Set the
field current switch to 3A for burn-in.

Set the "FIELD" switch to "A" or "B" according to the tester information given on the tester
instructions.

"A" Circuit - The "A" circuit regulator design has one alternator field lead connected to
battery (or trio) and the other end of the field is controlled or switched to ground by the
regulator.

"B" Circuit - The "B" circuit regulator design has one alternator field lead connected to
ground and the other field is controlled or switched to the battery (or trio) by the regulator.

Select the "Voltage Range" (12v, 12V, 3A or 24V) for the regulator being tested and turn
the power switch to the "ON" position.

If the short circuit light comes on, quickly turn the tester "OFF". The short circuit light
indicates that battery positive is being shorted to battery negative should the tester fail due
to overload, check the fuse. The Transpo VRC2010 is not to be used to check D.C.
generator regulators. The tester is designed to be used to test alternator regulators only.

TEST RESULTS "GOOD REGULATOR"

The regulator is operating correctly if the field light blinks and the digital meter displays
approximately the set point voltage given on the appropriate tester instructions. Sometimes
it may be necessary to adjust the voltage setting on those regulators that are adjustable.
See the tester instructions for the regulator being tested.

TEST RESULTS "BAD REGULATOR"

Full Field - The digital meter will indicate over 16.5V for a 12V regulator and over 29.5V for
a 24V regulator. The field light will not blink but will remain "ON". A regulator with this type
of defect will not be able to control the output voltage of the alternator.

Page 9
Table of Contents Regulator
Type Product Group
BOSCH IB
C.A.V CE
CHRYSLER C
DAEWOO DA
DELCO D
DUCELLIER ID
ELECTRODYNE E
FEMSA IF
FORD F
HARLEY H
HITACHI IH
ISKRA IK
LADA IR
LEECE NEEVILLE L
LUCAS IL
MAGNETI-MARELLI IX
MAGNETON-PAL PAL
MANDO IY
MITSUBISHI IM
MOTOROLA M5
NIEHOFF N
NIKKO IZ
NIPPONDENSO IN
PARIS RHONE IP
PRESTOLITE P8
SEV MARCHAL IS
SPECIALTY SR
STAR II AND STAR III ST-D
TRANSPO 911 SERIES 911
TRANSPO REPAIR CIRCUITS TRI
VALEO/MOTOROLA M

Page 10
TRANSPO TESTER INSTRUCTIONS
for CHRYSLER type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

C8010 B 12 14.3

C8012 B 12 14.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
N/A

Page 11
TRANSPO TESTER INSTRUCTIONS
for CHRYSLER type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

C8312 A 12 14.3

C8313 A 12 14.2

C8315 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
N/A

Page 12
TRANSPO TESTER INSTRUCTIONS
for C.A.V. type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

CE301 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 13
TRANSPO TESTER INSTRUCTIONS
for C.A.V. type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

CE520 A 24 HI 28.8

CE520 A 24 MID 27.8

CE520 A 24 LO 26.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 14
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D10 A 12 14.8 D21 A 12 14.0

D10SE8 A 8 9.6 DE610 A 12 14.7

D10SE24 A 24 27.5 D30 A 24 27.5

DE608 A 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 15
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D104HD-264 A 24 26.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 16
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D10AC B 12 14.2

D22AC B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 17
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D10SE132 A 12 14.8

D10SE138 A 12 14.8

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 18
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D1332 B 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the set point should be 14.5 +/-0.2V.
2. Reconnect Sense and disconnect Stator, the Light Lamp comes on, and the Field Lamp dims.
3. Reconnect Stator, push the Over Voltage button on the panel, the Light Lamp comes on.
4. Push the Choke Drive button on the panel, the Choke Lamp comes on.

• Stator Activated
• Over Voltage Lamp
• Under Voltage Lamp
• Field, Lamp short circuit protection
• Active Lamp – With Output

Page 19
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D17SE A 12 14.2 D27S A 12 14.0

D102HD A 12 13.7

D30S A 24 27.5

D27 A 12 13.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 20
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D198XHD B 12 14.8 D203XHD B 12 14.8

D200XHD B 12 14.8

D201XHD B 12 14.8

D202XHD B 12 14.8

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove Stator terminal, field light stays on voltage reads 12 volts and lamp light comes on. Remove light
terminal (and "I" terminal on PLIS type), voltage regulator turns off.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 21
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D2198 A 12 14.35

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 22
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D2206 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Stator, the Lamp Indicator comes on.
2. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indicator should be on.
3. Push the Field Diode button on the panel, the Field Diode LED should be on.

Soft Start & LRC function


Ignition or Light Activated
Over Voltage and Under Voltage Lamp
Standard Lamp -- Without output

Page 23
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D2295 A 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the set point should be 15.55+/-0.2V.

Light or Ignition Activated.

Page 24
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D3101 B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove WHITE TEST LEAD from terminal marked "STATOR", 12 volt Lamp will turn on and Field light will turn
off.

Page 25
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D3232 B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the setpoint should be 14.2+/-0.2V.
2. Reconnect Sense,disconnect Stator, the Lamp Indicator comes on.
3. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indicator comes on.

Light Activated
Soft Start
2.5s LRC function
Over Voltage, Under Voltage Lamp
Standard Lamp -- Without Output

Page 26
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D32S A 32 37.5 D10SE12 A 12 14.8

D10SE6 A 6 7.7 D101 A 12 14.8

D105 A 12 14.8 D101HD A 12 14.8

D105HD A 12 14.8

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 27
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D33 A 12 14.1

D22 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 28
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D3587 B 12 13.8*

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect IL terminal of D3587 to RCV terminal on tester. Connect FR terminal of D3587 to LI terminal on tester.
2. Adjust Comm Voltage switch to position 13, Setpoint is 11.8V.
3. Adjust Comm Voltage switch to position 14, Setpoint is 13.3V.
4. Adjust Comm Voltage switch to position 15, Setpoint is 14.7V.

• This is GM RCV type, ‘Regulated Voltage Control’ system regulator.


• Regulated Voltage Control is provided by the vehicle’s PCM / ECU or GBCM (Generator Battery Control
Module) via a digital ‘PWM’ signal applied to the regulator L-terminal.

Page 29
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D401 A 24 27.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 30
TRANSPO TESTER INSTRUCTIONS
for DAEWOO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D403 A 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
D403 Special Note: POWER ON field lamp may blink or illuminate steady-on to indicate a functional circuit.

D403 Special Note: POWER ON field lamp may blink or illuminate steady-on to indicate a functional circuit.

Page 31
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D404 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 32
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D408XHD B 12 14.8

D411XHD B 12 14.8

*D440G B 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "STATOR". The indicator light will turn on, field lamp will stay on and meter will
indicate approximately 12V. Disconnect the test lead from "L" terminal. Regulator will turn off and the meter will indicate 12V.
To check for over Voltage, push the “Over Voltage” switch and the “Lamp Indicator” will turn on between 16.0V and 17.1V.
Push the choke drive and the “Choke Drive Indicator Lamp” will turn on, if present.

NOTE: On D440 regulator, both of the "L" and "I" terminals must be connected in order to conduct the test.

Page 33
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D412 * B 12 14.2 D446 B 12 14.6

D413 B 12 14.7 D411SE B 12 14.7

D440 ** B 12 14.7

D425 B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "STATOR". The indicator light will turn on, field lamp will stay on
and meter will indicate approximately 12V. Disconnect the test lead from "L" terminal. Regulator will turn off and
the meter will indicate 12V. On "I" type voltage regulators, connect the regulators as per diagram below except do
not connect the indicator light to the "L" terminal. Connect red test lead to the terminal marked "I/F" and same
results as step number 2 should be noticed.

*NOTE: On D412 regulator , an 1800 OHM pull-up resistor is required between "S" terminal of regulator and the
testers battery POS.
**NOTE: On D440 regulator, both of the "L" and "I" terminals must be connected in order to conduct the test.

Page 34
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D4152 B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect Sense Lead and verify the setpoint is 14.2+/-0.2v.
Disconnect Stator Lead and verify the Light is on.
Push the OVER VOLTAGE button and verify the Light is on.

D4152 is Stator Activated.


Load AMP switch is 0.5 position only.

Page 35
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D424 B 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "stator". The indicator light will turn on, field lamp will stay on and
meter will indicate approximately 12V. Disconnect the test lead from "L" terminal . Regulator will turn off and the
meter will indicate 12V.

Page 36
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D432 B 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove the white test lead from terminal marked "STATOR". The indicator light will turn on, field lamp will stay on and meter
will indicate approximately 12V. Disconnect the test lead from "L" terminal. Regulator will turn off and the meter will indicate
12V.
Using VRC2010: To check for over Voltage, push the “Over Voltage” switch and the “Lamp Indicator” will turn on between
16.0V and 17.1V. Push the choke drive and the “Choke Drive Indicator Lamp” will turn on, if present.

Page 37
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D437 A 24 27.5

D559 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked with (*) . Field lamp should turn off and the meter will indicate low
voltage.

Page 38
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D437P A 24 27.5

D559P A 12 12.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 39
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D443 B 12 14.2

D447 B 24 27.5

D551 B 12 14.2

D597 B 24 27.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 40
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D443P B 12 14.2

D447P B 24 27.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 41
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D445 B 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "stator. The indicator light will turn on, field lamp will stay on and
the meter will indicate approximately 12 volts.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 42
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D4476 B 24 28.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect Sense Lead, verify the setpoint is 28.0+/-0.2v, also verify the the Light is on.
Disconnect Stator Lead, verify the Light is on and the part stops function.
Push the OVER VOLTAGE button and verify the Light is on.

D4476 is Stator Activated.


Load AMP switch is 0.5 position only.

Page 43
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D551P B 12 14.2

D597P B 24 27.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 44
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D590S B 12 14.2

D591S B 24 27.5

D593S B 32 37.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 45
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D698 B 12 14.2

D699 B 24 27.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 46
TRANSPO TESTER INSTRUCTIONS
for DELCO STAR II & STAR type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D7011 B 6 7.8

D7012 B 8 9.6

D7014 B 12 14.2

D7016 B 24 27.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect white test lead (Stator) from regulator's yellow wire. Field lamp should turn "OFF" and the meter will
indicate the original voltage range in step one.

Note: Indicator light will turn "ON" on part numbers: D7011, D7014, D7016, D7041.

Regulator Wire Test Lead Wire Function


Red Red Battery Positive
Black Black Battery Negative
Green Yellow Field
Yellow White Stator

Page 47
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D7018 A 12 14.2

D7019 A 24 27.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from regulator's wire marked "stator". Field lamp should turn off and the meter will
indicate low voltage.

Page 48
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D702XHD B 12 14.5

D703XHD B 12 14.5

D705XHD B 12 14.7

D706XHD B 12 14.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "stator". The indicator light will turn on, field lamp will stay on and
the meter will indicate approximately 12 volts.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 49
TRANSPO TESTER INSTRUCTIONS
for DELCO STAR II & STAR type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D7044 B 12 14.7

D7024 B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect white test lead (Stator) from regulator's yellow wire. Field lamp should turn "OFF" and the meter will
indicate the original voltage range in step one.

Note: Indicator light will turn "ON" on part numbers: D7044, D7021, D7024, D7026.

Regulator Wire Test Lead Function


Red Red Battery Positive
Black Black Battery Negative
Green Yellow Field
Yellow White Stator

Page 50
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D7050 B 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "stator". Regulator will turn off and the meter will indicate 12V.

Page 51
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D710 B 6 7.8

D713 B 12 14.2

D173L B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "stator". Field lamp should turn off and the meter will indicate low
voltage. On D713L regulator, removal of white test leads will also cause indicator light to turn on.

Page 52
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D712 B 12 14.6 D734 B 12 14.6

D718 B 12 14.7 D749 B 12 14.6

D719 B 12 14.75 D748 B 12 14.8

D729 B 12 14.75 D752 B 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "stator". the indicator light will turn on, field lamp will stay on and
meter will indicate approximately 12v. Disconnect the test lead from "L" terminal. Regulator will turn off and the
meter will indicate 12v. On "I" type voltage regulators, connect the regulators as per diagram below except do not
connect the indicator light to the "L" terminal. Connect red test lead to the terminal marked "I/F" and same results
as step number 2 should be noticed.

Page 53
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D751 A 12 15.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
IMPORTANT ... Tester FIELD LOAD Switch Must Be Set to 0.5 AMP !

Remove "White" test lead from terminal marked "Stator". The indicator light will turn on, field lamp will stay on and
the meter will indicate approximately 12 volts. Remove red test lead from Sense and light will come on. Remove
"Green" test lead, lamp will go off and field lamp will go off.

IMPORTANT ... Tester FIELD LOAD Switch Must Be Set to 0.5 AMP !

Page 54
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D812 A 12 14.2

D817 A 12 14.2

D824 A 24 27.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from the regulator's yellow wire. Field lamp should turn off and the meter will indicate low
voltage. Also, connection the red test lead to "NO CONNECTION" terminal instead of regulator's red wire will
result in the same test data.

Page 55
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D812 A 12 14.2 D824 A 24 27.5

D812HD A 12 14.2 D824HD A 24 27.5

D813 A 12 14.2 D832 A 32 37.5

D813HD A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 56
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D817 A 12 14.2

D817HD A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 57
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D840 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the part stops regulating and the voltage goes down to 12.0v.

Page 58
TRANSPO TESTER INSTRUCTIONS
for DELCO 5si type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D850

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 59
TRANSPO TESTER INSTRUCTIONS
for type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D907 B 12 14.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect Stator Lead and verify the Light is on.

B-Circuit, Volt Set 14.0V


• S-F-L-P Terminals
• Stator Activated
• Full Short Circuit Protection
• Excellent Choice for 1-Wire System

Page 60
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D9206 B 6 7.8

D9207 B 6 7.8

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
On D9207, remove test lead from the terminal marked "STA". Field lamp will turn off , indicator light will turn on,
and the meter will indicate low voltage.

Page 61
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D9212 B 12 14.2 D6378 B 12 14.6

D9212S B 12 14.2 D6377 B 12 14.6

D9212C B 12 14.2 D518 B 24 27.5

D6374 B 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
On all above parts numbers except D6377, disconnect red test lead from the terminal marked with "S" Indicator
light should turn on and the meter will indicate set point voltage.

Page 62
TRANSPO TESTER INSTRUCTIONS
for CS130D type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

D9715 B 12 14.70

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1.POWER OFF: Set “Voltage Range” and “FLD” switches to desire settings; Connect the voltage regulator
as indicated in the diagram below, except for the “Computer” terminals.
2.POWER ON: Field lamp should blink and meter will indicate approximately the set point voltage
indicated in the above table.
3.Connect black test lead to “Computer” terminal voltage goes to approx. 13.2 volts, Disconnect black test lead from
“Computer” terminal. Disconnect “Stator” terminal, light comes on and voltage reads 12.0 volt and field light stays on.

Page 63
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

DE1650 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Push the Over Voltage button on the panel, the Lamp Light comes on.
2. Push the Choke Drive button on the panel, the Choke Light comes on.

Stator Activated.

Page 64
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

DE604 A 12 14.8

DE605 A 12 14.8

DE609 A 12 14.8

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 65
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

DE606 A 12 14.5

DE607 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 66
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

DE611 A 12 14.7

DE615 A 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 67
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

DE701 A 12 14.7

DE701HD A 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 68
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

DE708 B 12 14.8

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove "White" test lead from "Stator" lamp will come on and voltage will go to 12 volts.
Reconnect "White" test Lead.
Remove "Green" Lead from "Light" terminal regulator will go to 12 volts and "Field" light will stop blinking.

Page 69
TRANSPO TESTER INSTRUCTIONS
for DELCO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

DE708HD B 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

B circuit, high side drive


Light actived
with softstart
with LRC

Page 70
TRANSPO TESTER INSTRUCTIONS
for FORD type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

F540 B 12 14.3 F540SP B 12 14.2

F540HD B 12 14.2 F540XHD B 12 14.2

F540S B 12 14.3 F782 B 12 14.2

F540SLD B 12 14.2 F783 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red lead from terminal marked "S". Indicator light should turn on and meter will still indicate set point
voltage. Removal of test lead from "S" and "I" terminal will result in the field lamp turning off and the meter
reading 12V. On Mechanical type regulators (F8512M), the "short circuit" light will also turn on due to the
regulator's internal circuitry. Limit this test to a short time.

Page 71
TRANSPO TESTER INSTRUCTIONS
for FORD type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

F600 A 12.0 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked “Stator”, field light stays on, voltage remains at 14.3 volt and
indicator light turns on. Remove green test lead from “Light” terminal, field light and 12.0 volt light turn off.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 72
TRANSPO TESTER INSTRUCTIONS
for FORD type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

F601 A 12 14.0*

F601HD A 12 14.0*

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Use VRC2010 tester to complete RC voltage setpoint testing,Connect RC terminal to VRC2010 tester.
1. Adjust Comm Voltage switch to position 13, Setpoint is 12.9V.
2. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.
3. Adjust Comm Voltage switch to position 15, Setpoint is 14.8V.
* The 14.0V Set Point indicate above is the 'default VSet' (no vehicle PCM input).

• AS-RC-LI Terminals
• Regulation Voltage Controlled by Vehicle PCM

Page 73
TRANSPO TESTER INSTRUCTIONS
for FORD type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

F602 A 12.0 14.4

F603 A 12.0 14.4

F605 A 12.0 14.4

F606 A 12.0 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked “Stator”, field light stays ON. On F602 voltage drops to 12.0 volts and indicator
light turns ON. On F603 voltage stays at 14.4 volts and lamp turns ON. Remove green test lead from “Light” terminal, field
light and lamp turn OFF.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V and 17.1V.
Note: F605 Disconnect sense terminal, regulator should read aproximately 14.8V.

Page 74
TRANSPO TESTER INSTRUCTIONS
for FORD type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

F610 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
To Check for presence of over voltage function-Press “over-voltage button”

• S-D-L Terminals (Sense-N/C-Light)


• M3 Field Post
• F610 noted to replace OE regulators having a white insert surrounding the heat sink.

Page 75
TRANSPO TESTER INSTRUCTIONS
for FORD type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

F611 A 12V 14.0*

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Use VRC2010 tester to complete RC voltage setpoint testing:
1. Connect RC terminal to VRC2010 tester.
2. Adjust Comm Voltage switch to position 13, Setpoint is 12.9V.
3. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.
4. Adjust Comm Voltage switch to position 15, Setpoint is 14.8V.
* The 14.0V Set Point indicate above is the 'default VSet' (no vehicle PCM input).

Page 76
TRANSPO TESTER INSTRUCTIONS
for FORD type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

F613 A 12 14.45

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
To check presence of over voltage function- Press O.V. button

• AS-FR-IL Terminals
• Soft Start
• Over-Voltage Lamp Function
• F613 noted to replace OE regulators having a green insert surrounding the heat sink.

Page 77
TRANSPO TESTER INSTRUCTIONS
for FORD type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

F7078 B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked " Stator". Field lamp should turn off, indicator light will turn on and
the meter will indicate low voltage.

Page 78
TRANSPO TESTER INSTRUCTIONS
for FORD type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

F733L B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "stator". Field lamp should turn off and the meter will indicate low
voltage. On F733L regulator, removal of white test lead will result in indicator light turning on.

* NOTE: No Yellow wire for F733

Page 79
TRANSPO TESTER INSTRUCTIONS
for FORD type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

F784 A 12 14.6 F785 A 12 14.6

F784HD A 12 14.6 F786 A 12 14.6

F794 A 12 14.6 F794B A 12 14.6

F784B A 12 14.6 F795 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Indicator light should turn on and the meter will still indicate the
set point voltage. Removal of test of leads from "S" and " I" will result in field lamp turning off and the meter
reading 12V.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

NOTE: On Transpo's F786 & F795 connect white test lead to terminal marked "S".

Page 80
TRANSPO TESTER INSTRUCTIONS
for FORD type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

F796 A 12.0 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 81
TRANSPO TESTER INSTRUCTIONS
for FORD type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

F797 A 12 *14.0

F797HD A 12 *14.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect RC terminal of regulator to RCV regulator on tester. Connect LI terminal of regulator to LI terminal on tester.
1. Adjust Comm Voltage switch to position 13, Setpoint is 12.9V.
2. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.
3. Adjust Comm Voltage switch to position 15, Setpoint is 14.8V.
* The 14.0V Set Point indicated above is the 'default VSet' (no vehicle PCM input).

Page 82
TRANSPO TESTER INSTRUCTIONS
for FORD type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

F798 A 12.0 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from stator and voltage will remain the same and 12 volt lamp will come on.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 83
TRANSPO TESTER INSTRUCTIONS
for FORD type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

F8512 B 12 14.2

F8512M B 12 14.3

F8512S B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Indicator light should turn on meter will still indicate set point
voltage. Removal of test lead from "S" and "I" terminal will result in the field lamp turning off and the meter
reading 12v. On mechanical type on due to the regulator's internal circuitry. Limit this test to a short time.

Page 84
TRANSPO TESTER INSTRUCTIONS
for FORD type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

FB123 B 12 14.2

FB303 B 12 14.2

FB309 B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from blue wire of the regulator. Field lamp should turn off and the meter will indicate 12V.

Page 85
TRANSPO TESTER INSTRUCTIONS
for HARLEY type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

H0478 A 12 15.1

H0482 A 12 15.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 86
TRANSPO TESTER INSTRUCTIONS
for HARLEY type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

H606 A 6 7.5

H614 A 12 15.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 87
TRANSPO TESTER INSTRUCTIONS
for HARLEY type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

H8615 A 12 15.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 88
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB033A B 24 28.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 89
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB160 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

A circuit,low side drive


STA activated and light activated to softstart
without LRC
with softstart
with F function

Page 90
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB200 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Stator, the Lamp Indicator comes on and the Field Circuit LED should be dim.
2. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indicator comes on.
3. Push the Choke Drive button on the panel, the Choke Drive Indicator comes on.

• VSet 14.4 +/- 0.2


• 15-61E Terminals (15=IGN, 61E=IL/Lamp)
• With Soft Start & LRC
• Ignition, Lamp, or Stator Activated
• Active Lamp – With Output

Page 91
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB201 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1 Remove white test lead from terminal marked "Stator" - the Field light and Lamp will come on and
Voltage will show 12 volts.
2 Remove green test lead from "light" terminal , field light will go out and voltage stays at 12 volts.
3 No Over Voltage and Lamp.
4 Push choke drive button and choke drive lamp should be on.

• VSet 14.4 +/- 0.2


• L-DFM Terminals
• 2.5 Second LRC
• Active Lamp Circuit - With Output
• Ref. F-00M-225-401, 0-122-1AA-5BO, 0-122-9AA-0X0

Page 92
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB206 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Do not connect FR terminal.
Push Over Voltage button, Light should be ON, set point is approximately 17.3 volts.
Push Choke button and Choke light should be ON.

Page 93
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB225 A 12 14.5

IB5225 A 12 14.5

IB247 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect (FR) to tester “LI”, Grey

• Remove white test lead from terminal marked "Stator" - the Field light and Lamp will come on and
Voltage will show 12 volts.
• Remove green test lead from "light" terminal , field light will go out and voltage stays at 12 volts.
• To check for Over Voltage using VRC1000, push the “Over Voltage” switch and the “Lamp Indicator” will
turn on between 16.0V and 17.1V.

Page 94
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB226 A 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 95
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB227 A 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Push the Over Voltage button on the panel, the Lamp Indicator comes on.
2. Disconnect Stator, the Lamp Indicator comes on.

Light Activated
Soft Start
3 seconds LRC
OV, UV Lamp

Page 96
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB229 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove White Test lead from Stator Terminal, Lamp will come on, display will show 12 volts and field light will
stay on. Remove Green Test lead and field light will turn off.

Page 97
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB231 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
VRC2010 Tests:
• To check for presence of Active Lamp function - Press ‘Choke Drive’ button, choke lamp will illuminate
• To check for presence of Over Voltage function - Press ‘Over Voltage’ button, indicator lamp will illuminate

IB231
• With LRC and Soft Start
• L (D+) Terminal M5

Page 98
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB235 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove White Test Lead from Stator, Lamp Light comes on and Field Light stay on.
Remove Green Test Lead from Light terminal, Lamp Light and Field Light turn off.

Page 99
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB236 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove White Test Lead from Stator, Lamp Light comes on and Field Light stay on.
Remove Green Test Lead from Light terminal, Lamp Light and Field Light turn off.

•IG-S-L-DFM Terminals • With LRC 5-Seconds • External Sense • Ignition Activated but will Lamp Activate
and Stator Start • Active Lamp Function -With Output • Field, Lamp, Choke Short Circuit Protection

Page 100
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB241 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "Stator" volts will drop to 12 volts; field light and lamp light will
come on. Remove green test lead from terminal marked "light", field and lamp light will go out and voltage
remains at 12 volts.
To check for over Voltage, push the “Over Voltage” switch and the “Lamp Indicator” will turn on between 16.0V
and 17.1V.

Page 101
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB248 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove White Test lead from Stator Terminal, Lamp will come on, display will show 12 volts and field light will
stay on. Remove Green Test lead and field light will turn off.

Page 102
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB251 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Power On: Field light should blink and meter will indicate approximately the set point voltage indicated in the above table.
Remove white test lead from terminal marked "Stator" field light and "Lamp" light will come on and voltage will show 12 volts.
Reconnect "Stator" wire;Remove green test lead from "Light" terminal, field light will continue to blink and meter will indicate
approximately the set point voltage indicated in the above table. Reconnect "Lamp" wire;Remove ignition, field light will
continue to blink, "Lamp" light will turn on and meter will indicate approximately the set point voltage indicated in the above
table.

Page 103
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB252 B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove White test Lead from Stator Light comes on. Reconnect Stator.
Remove Red test Lead from Sense, Light comes on. Reconnect Sense.
Remove Green test Lead from Lamp, voltage remains same. Reconnect Light.
Remove White test Lead from Stator, Light and Ignition voltage goes to 12 volts.

• L-Terminal M5
• Active Lamp Function - With Output
• Lamp, Field, Choke Drive Short Circuit Protection

Page 104
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB261 B 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
• Remove white test lead from terminal marked "Stator" - the Field light and Lamp will come on and
Voltage will show 12 volts.
• Remove green test lead from "light" terminal, field light will go out and voltage stays at 12 volts.

• L-FR Terminals • Stator Activated• With Soft Start & LRC• TC -10mV/C• Active Lamp Circuit -With Output

Page 105
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB266 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

A circuit,low side drive


Light/Stator activated
with softstart
with LRC
with FR function

Page 106
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB286 B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
• To check for presence of Active Lamp function - Press ‘Choke Drive’ button, choke lamp will illuminate
• To check for presence of Over Voltage function - Press ‘Over Voltage’ button, indicator lamp will
illuminate

• L-DFM Terminals • LRC 2.5 Seconds, w/ Soft Start • Active Lamp Function – With Output
NOTE: VRC101-34 adapter shown for enhance stator signal, not all late model regulators need enhance signal

Page 107
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB297 B 24 28.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect FR to tester “LI”, Grey.

Remove White test Lead from Stator Light comes on. Reconnect Stator.
Remove Red test Lead from Sense, Light comes on. Reconnect Sense.
Remove Green test Lead from Lamp, voltage remains same. Reconnect Light.
Remove White test Lead from Stator, Light and Ignition voltage goes to 12 volts.
• W-L-15-S-DFM Terminals • OE Compliant Circuit Protection & Functions... 'With Stator Start,

Page 108
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB298 B 24 28.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove White test Lead from Stator Light comes on. Reconnect Stator.
Remove Green test Lead from Lamp, voltage remains same. Reconnect Light.
Remove White test Lead from Stator, Light and Ignition voltage goes to 12 volts.

• Note: IB298 without Loss of Sense Lamp Indication


• W-L-15-S-DFM Terminals • OE Compliant Circuit Protection & Functions... 'With Stator Start,

Page 109
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB301 B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 110
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB303 B 12 14.4

IB303A B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 111
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB305 B 12 14.8

IB306 B 12 14.8

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

NOTE: IB306 Superseded by IB305-1

Page 112
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB307BZ B 24 28.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Trio Excited.
Trio connected to Light

Page 113
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB308 B 24 28.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 114
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB308BZ B 24 28.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Trio Excited.
Trio connected to Light.

Page 115
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB313 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Stator, the Lamp Indication comes on.
2. Reconnect Stator, push the Choke Drive button on the panel, the Choke Drive Indication comes on.

Soft Start function


2 seconds LRC
Stator or Light Activated
Active Lamp function -- With Output

Page 116
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB314 B 12 13.8*

IB696 B 12 13.8*

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Use VRC2010 tester to complete RC voltage setpoint testing,Connect RC terminal to VRC2010 tester.
1. Adjust Comm Voltage switch to position 13, Setpoint is 11.8V.
2. Adjust Comm Voltage switch to position 14, Setpoint is 13.3V.
3. Adjust Comm Voltage switch to position 15, Setpoint is 14.4V.
Note: The Voltages listed above are approximate and may not exactly match your meter read out.

• This is an RVC type, ‘Regulated Voltage Control’ system regulator.


• Regulated Voltage Control is provided by the vehicle’s PCM / ECU or GBCM (Generator Battery Control
Module) via a digital ‘PWM’ signal applied to the regulator L-terminal.

Page 117
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB343 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "STA"; meter will indicate set point and lamp light will come on. Reconnect the
white test lead. Remove red test lead from the terminal marked "SENSE", the meter will indicate 12V, field lamp will stay on
and lamp light will come on. Remove green test lead; field and lamp light will turn off.
To check for over Voltage, push the “Over Voltage” switch and the “Lamp Indicator” will turn on between 16.0V and 17.1V.

Page 118
TRANSPO TESTER INSTRUCTIONS
for type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB347 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 119
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB348 A 12 15.0 IB353 A 12 14.5

IB350 A 12 14.1 IB354 A 12 14.1

IB351 A 12 14.5 IB355 A 12 14.5

IB352 A 12 14.1 IB356 A 12 14.8

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 120
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB360 A 12 14.1 IB364 A 24 29.0

IB368 A 12 14.1 IB369 A 24 28.0

IB362 A 24 28.00 IB366-1 A 24 28.5

IB363 A 24 28.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 121
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB365 A 24 28.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 122
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB370 A 12 14.5

IB370A A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 123
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB371 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 124
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB375 A 12 14.4 IB379 A 24 28.1

IB376 A 24 27.5 IB374 A 24 27.5

IB377 A 12 14.4

IB378 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 125
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB380 A 12 14.4 IB387 A 12 14.5

IB383 A 12 14.4

IB384 A 12 14.4

IB385 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 126
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB382 A 24 28.8

IB381 A 24 28.1

IB316 A 24 28.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 127
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB386 A 28 28

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 128
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB388 A 12 14.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 129
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB389 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

A circuit
with LRC

Page 130
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB390 A A 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 131
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB392 A 12 14.4

IB391 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove Red test lead from terminal marked "STA". lamp comes on and the meter will indicate set point voltage.
Reconnect the white test lead. Remove red test lead from the terminal marked "S", field lamp will turn on, the
indicator light will turn on and the meter will indicate 12V.

Page 132
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB392BG A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "STA". Field lamp remain fully on and the meter will indicate
approximately 12V. Reconnect the white test lead. Remove red test lead from the terminal marked "S", field lamp
will turn off, the indicator light will turn on and the meter will indicate 12V.
Using VRC2010: To check for over Voltage, push the “Over Voltage” switch and the “Lamp Indicator” will turn on
between 16.0V and 17.1V.

NOTE: Connect B- (black) test lead last, already having turned on the tester "ON" switch.
• 20 ampere 60 volt field transistor voltage saturation test @ 5 amps 13.50 volts = 150 to 250 milli-volts
• Undervoltage Lamp Indication = 8.50 volts to 10.00 volts
• Overvoltage Lamp Indication = 16.00 volts to 17.10 volts
• Current Leakage = 2.0 milli-amps

Page 133
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB398 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 134
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB399 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 135
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB400 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 136
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB501 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 137
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB511 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 138
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB512 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 139
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB520 A 12 14.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect Stator Lead and verify the Light is on.
Push the CHOKE DRIVE button and verify the CHOKE DRIVE lamp is on.

IB520 is Stator Activated.


Load AMP switch is 0.5 position only.

Page 140
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB5300 B 24 25.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

B circuit,high side drive


Ignition activated
with softstart
with FR function

Page 141
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB5353 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove test lead from terminal marked "Stator" - the Field light and Lamp will come on and
Voltage will show 12 volts.
Push the Choke Drive button on the panel, the Choke Drive Indicator will come on.

• L-FR Terminals
• With LRC and Soft Start
• Active Lamp Circuit - with Output
• VRC101-34 adapter shown for enhance stator signal, not all late model regulators need enhance signal

Page 142
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB5369 B 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Push the Choke Drive button on the panel, the Choke Light comes on.
2. Disconnect Stator, the Lamp Light comes on, the Field Lamp is dim.

Stator Activated

Page 143
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB558 B 24 25.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Power On: Note Set Point on VRC2010 digital display;Disconnect Sense terminal and note set point reading
should rise to approximately 28.5 volts.

Page 144
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB677 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Stator, the Lamp Indicator comes on.
2. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indicator comes on.
3. Push the Choke Drive button on the panel, the Choke Drive Indicator comes on.

Light or Stator Activated


Soft Start
2 seconds LRC
Over Voltage Lamp
Active Lamp -- With Output

Page 145
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB680 B 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Push the Choke Drive button on the panel, the Choke Drive Indicator comes on.
2. Disconnect Stator, the Lamp Light comes on, the Field Lamp is dim.

soft start function


8 seconds LRC
Active Lamp function -- With Output
Stator or Light Activated.

Page 146
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB8315 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 147
TRANSPO TESTER INSTRUCTIONS
for BOSCH type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IB861 B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Stator, the Lamp Indicator comes on.
2. Reconnect Stator, push the Choke Drive button on the panel, the Choke Drive Indicator comes on.

Stator or Light Activated.


Soft Start & LRC function
Active Lamp -- With Output

Page 148
TRANSPO TESTER INSTRUCTIONS
for DUCELLIER type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

ID1004 A 14 14.3

ID1016 A 14 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect red test lead from stator (blue) wire indicator lamp will come on regulator will continue to read
14.4/14.5 volts. Reconnect stator lead and lamp will go out.

Page 149
TRANSPO TESTER INSTRUCTIONS
for DUCELLIER type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

ID1006 A 12 14.3

ID1010 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from the blue wire of the regulator. Indicator light should turn on and the meter will still
indicate the set point voltage.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 150
TRANSPO TESTER INSTRUCTIONS
for DUCELLIER type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

ID1007 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect red test lead from stator (blue) wire indicator lamp will come on regulator will continue to read
14.4/14.5 volts. Reconnect stator lead and lamp will go out.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 151
TRANSPO TESTER INSTRUCTIONS
for DUCELLIER type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

ID1011 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect red test lead from stator (blue) wire indicator lamp will come on regulator will continue to read
14.4/14.5 volts. Reconnect stator lead and lamp will go out.

Page 152
TRANSPO TESTER INSTRUCTIONS
for DUCELLIER type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

ID1015 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 153
TRANSPO TESTER INSTRUCTIONS
for DUCELLIER type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

ID1018 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from the blue wire of the regulator. Indicator light should turn on the meter will still indicate
the set point voltage.

Page 154
TRANSPO TESTER INSTRUCTIONS
for DUCELLIER type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

ID4009 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 155
TRANSPO TESTER INSTRUCTIONS
for FEMSA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IF1692 A 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 156
TRANSPO TESTER INSTRUCTIONS
for FEMSA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IF5442 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red lead from terminal marked stator. Indicator light will come on, reconnect. Light shuts off.

Page 157
TRANSPO TESTER INSTRUCTIONS
for FEMSA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IF8603 A 12 14.7

IF8607 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 158
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH201 A 12 14.3

IH202 A 12 14.3

IH203 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 159
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH205 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove (Red) Sense lead, voltage should go to 15.5V.

Page 160
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH209 A 12 14.7 IH212 A 12 14.3

IH210 A 12 14.3 IH213 A 12 14.3

IH210HD A 12 14.2

IH211 A 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 161
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH214 A 12 14.4

IH215 A 12 14.2

IH707 A 24 28.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 162
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH237 A 12 14.6

IH238 A 12 14.6

IH239 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicate
approximately 15.5V.

Page 163
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH240 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S" Field lamp should still blink and the meter will indicate
approximately 15.5V.

Page 164
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH241 A 12 14.6

IH244 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicate
approximately 15.5V.

Page 165
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH242 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicate
approximately 15.5V.

Page 166
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH243 A 12 14.6

IH246 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicate
approximately 15.5V.

Page 167
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH245 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal "S" Field lamp should still blink and the meter will indicate approximately 15.5
V.

Page 168
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH247 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "STA". Indicator light should turn on, field lamp will remain on and
meter will indicate approximately 12V. Remove red test lead from terminal marked "IG". Field lamp should turn
off.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 169
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH248 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicate
approximately 15.5V.

Page 170
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH249 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp should blink and the meter will indicate approximately
15.5V.

Page 171
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH250 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicate
approximately 1 volt higher than set point.

Page 172
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH251 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp should blink and the meter will indicate approximately
15.5V.

Page 173
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH252 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove sense. Voltage goes to 15.6V and field light stays on.

Page 174
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH254 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove (Red) lead from sense , Field lamp will stay on, voltage will rise between 15.5V and 15.9V.

Page 175
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH258 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 176
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH605 B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from the terminal marked "STA". Warning light will turn on and meter should set point
voltage.

Page 177
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH701 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the light comes on, the part continues regulating.

Light Activated

Page 178
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH708 A 24 28.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect a red test lead to the terminal marked "C". The field lamp should still blink and the meter will indicate
approximately 26.3 V.

Page 179
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH717 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 180
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH737 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the setpoint should be 15.3+/-0.2V.
2. Reconnect Sense, disconnect Stator, the Light should be on.

Light Activated.
Soft Start
9.2 seconds LRC
Standard Lamp -- Without Output

Page 181
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH738 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove sense lead and voltage rises to approximately 15.5 volts, reconnect sense lead. Remove white test lead
from stator, 12 volt lamp comes on, voltage drops to 12 volts and field LED stays on (soft start).

Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on
between 16.0V and 17.1V.

Page 182
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH741 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect the C terminal to VRC2010,push the COMPUTER button to check the C function.
1. Disconnect Sense, the setpoint should be 15.2+/-0.2V
2. Reconnect Sense, disconnect Stator, the Lamp Indicator comes on.
3. Reconnect Stator, connect C to VRC2010, the setpoint should be 13.0+/-0.2V.

Light Activated.
Soft start
9s LRC
Field, Lamp short circuit protection
Standard Lamp, without output

Page 183
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH742 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove sense lead and voltage rises to approximately 15.5 volts, reconnect sense lead. Remove white test lead
from stator, voltage remains the same and lamp comes on.

Using VRC2010:To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on
between 16.0V and 17.1V.

Page 184
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH743 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the setpoint is 15.3+/-0.2V
2. Reconnect Sense, connected C to B-, the setpoint should be 12.75+0.25/-0.15V.
3. Disconnect C, disconnect Stator, the Lamp Indicator comes on.
4. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indicator comes on.

Lamp Activated.
Over Voltage, Under Voltage Lamp.

Page 185
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH744 A 12.0 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove sense lead and voltage rises to approximately 15.5 volts, reconnect sense lead. Remove white test lead
from stator, 12 volt lamp comes on, voltage drops to 12 volts and field LED stays on (soft start).

Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on
between 16.0V and 17.1V.

Page 186
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH745 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the setpoint should be 15.3+/-0.2V.
2. Reconnect Sense, disconnect Stator, the Light should be on.

Light Activated.
Soft Start
9 seconds LRC
Standard Lamp -- Without Output

Page 187
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH746 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the setpoint should be 15.3+/-0.2V.
2. Reconnect Sense, disconnect Stator, the Light should be on.

Light Activated.
Soft Start
9 seconds LRC
Standard Lamp -- Without Output

Page 188
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH747 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
disconnect the SENSE, the setpoint is about 15.2V, lamp is on

A circuit, low side drive


light activated
with LRC
with soft start
with C function

Page 189
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH758 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Caution - Note:• IH758 has D-P terminal functions: D=Drive, P=Phase.
• D-P Type Regulators are immediately damaged if tested using procedure typical to common S-L type
regulators, where B+ Voltage would be applied to the D terminal position.

Page 190
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH760 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Filed lamp should still blink and the meter will indicate
approximately 15.5 volts.

Page 191
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH761 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "Stator". 12V lamp should illuminate and the meter will indicate
approximately 12.0 V.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 192
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH762 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "STA". Field lamp will remain fully on and the meter should indicate
12V.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 193
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH763 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red lead from terminal marked "S" and voltage will rise to approximately 15.5V. Remove stator and lamp
comes on and voltage drops to 12V.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 194
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH765 A 12 14.3

IH767 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "Stator". 12V lamp should illuminate and the meter will indicate
approximately 12 volts.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 195
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH766 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect "S", Voltage stays the same , 12V lamp comes on and field lamp continues to be on and field lamp
continues to be on.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 196
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH768 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Filed lamp should still blink and the meter will indicate
approximately 15.5 volts.

Page 197
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH769 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white lead from stator; 12 volt lamp will come on and voltage will read 12.0 volts. Field lamp will be on.

Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on
between 16.0V and 17.1V.

Page 198
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH770 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect "S", voltage goes to approximately 15.2V Field lamp stays on.

Page 199
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH772 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove stator and lamp comes on. Apply ground to "C" Terminal and voltage will drop to 12.5 volts.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.

Page 200
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH774 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white lead from stator, field circuit lamp will stay on. 12V lamp will come on and voltage will drop to 12V.

Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on
between 16.0V and 17.1V.

Page 201
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH776 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white lead from stator, field circuit lamp will stay on. 12V lamp will come on and voltage will drop to 12V.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 202
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH782 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect (white ) lead from stator, voltage drops to 12V and lamp comes on. Disconnect (Red) lead from
sense, lamp comes on and rises to 15.5V.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 203
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH784 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

TRIO EXCITED

Page 204
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH811 B 12 14.3

IH814 B 12 14.3

IH820 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove test lead from terminal marked "STA" Indicator light should turn on and the meter will still indicate the
set point voltage.

Page 205
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH815 B 12 14.3

IH816 B 12 14.3

IH830 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove test lead from terminal marked "STA" Indicator light should turn on and the meter will still indicate the set
point voltage.

Page 206
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH832 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove black test lead from terminal marked "STA". Indicator lamp should turn on and the meter will still indicate
the set point voltage.

Page 207
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IH833 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove test lead from terminal marked "STA". Indicator light should turn on and the meter will still indicate the
set point voltage.

Page 208
TRANSPO TESTER INSTRUCTIONS
for ISKRA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IK401 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 209
TRANSPO TESTER INSTRUCTIONS
for ISKRA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IK404 A 24 28.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 210
TRANSPO TESTER INSTRUCTIONS
for LUCAS type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IL1292 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 211
TRANSPO TESTER INSTRUCTIONS
for LUCAS type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IL211 A 12 14.2

IL213 A 12 14.2

IL217 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 212
TRANSPO TESTER INSTRUCTIONS
for LUCAS type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IL214 A 12 14.2

IL215 A 12 14.2

IL216 A 12 14.2

IL218 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 213
TRANSPO TESTER INSTRUCTIONS
for LUCAS type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IL217 A 12 14.25

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Trio Excited.

Page 214
TRANSPO TESTER INSTRUCTIONS
for LUCAS type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IL219 A 12 14.3

IL220 A 12 14.3

IL221 A 12 12.3

IL222 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 215
TRANSPO TESTER INSTRUCTIONS
for LUCAS type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IL223 A 12 14.3

IL225 A 24 28.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 216
TRANSPO TESTER INSTRUCTIONS
for LUCAS type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IL224 A 12 12.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 217
TRANSPO TESTER INSTRUCTIONS
for type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IL7020JMP A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

TRIO Excited.

Page 218
TRANSPO TESTER INSTRUCTIONS
for LUCAS type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IL7044JMP A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Trio Excited.

Page 219
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM204 A 12 14.6

IM204HD A 12 14.6

IM205 A 12 14.6

IM225 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
On IM225 regulator, remove red test lead from terminal marked "*". Field lamp should still blink and the meter
will indicate approximately 15.4V.

Page 220
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM206 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 221
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM207 A 12 14.5

IM213 A 24 28.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 222
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM209 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S" field lamp will still blink, and the meter will indicate approximately
15.5V.

Page 223
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM210 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp will still blink, and the meter will indicate
approximately 15.5V.

Page 224
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM211 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 225
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM212 A 24 28.4

IM208 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 226
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM214 A 24 28.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 227
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM215 A 24 28.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 228
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM216 A 12 14.5 IM217 A 12 14.3

IM216HD A 12 14.5

IM289 A 12 14.5

IM217HD A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
On IM217 Regulator, remove red test lead from terminal marked "*". Field lamp should still blink and the meter
will indicate approximately 15.4V.

Page 229
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM224 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect another black test lead to terminal marker "Quick Start". Field lamp should still blink and the meter will
indicate approximately 13.0V.

Page 230
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM226 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 231
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM227 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 232
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM232 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 233
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM261 A 12 14.5

IM269 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
On IM261, remove red test lead from the terminal marked "*". Field lamp should still blink and the meter will
indicated approximately 15.4 v.

IM261: S-L Terminals


IM269: R-L Terminals

Page 234
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM262 A 12 14.5

IM263 A 12 14.5

IM265 A 12 14.5

IM265HD A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicate
approximately 1.5V above the set point voltage.

Page 235
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM264-2 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
disconnect the SENSE, the setpoint(DMM reading) is about 15.2V

Page 236
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM266 A 12 14.5

IM266HD A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 237
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM267 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "C" and connect a black test lead to it . Field lamp should still blink
and the meter will indicate approximately 12.5V.

Page 238
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM268 A 12 14.5

IM270 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
On IM268, removal of red test lead from terminal marked "A" should result in the indicator light to turn on and the
meter will indicate approximately 15.7V. On IM270, Removal of test lead "A" terminal should result in the meter
to indicate approximately 15.7V.

Page 239
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM271 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp should still blink, indicator light turn on and the meter
will indicate approximately 15.5V.

Page 240
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM272 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "A". Field lamp should still blink , indicator light will turn on and the
meter will indicate approximately 15.5V.

Page 241
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM273 A 12 14.4

IM839 A 12 14.4

IM835 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "TRIO". field lamp should still blink indicator light will turn on and
meter will indicate the set point voltage.

Reconnect red test lead to terminal marked "Trio". Connect black test lead to "C" terminal. Field lamp should still
blink and meter will indicate approximately 12.5V.

Page 242
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM274 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicate
approximately 15.5V.

Page 243
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM275 A 12 14.7

IM834 A 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 244
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM276 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Indicator light will turn on, Field lamp will still blink, and the
meter will indicate approximately 15.5V.

Page 245
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM277 A 12 14.5

IM278 A 12 14.5

IM279 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicate
approximately 15.5V. (on IM277 & IM279 indicator light will turn on.)

Page 246
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM280 A 12 14.4

IM837 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S" Indicator lamp should turn on, will still blink, and the meter will
indicate approximately 15.5V.
Push the choke drive switch and the "Choke Drive Indicator Lamp" will turn on between 16.0V and 17.1V.

Page 247
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM282 A 12 14.4

IM281 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". field lamp should still blink and the meter will indicated
approximately 15.5V.

Page 248
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM283 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 249
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM284 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp will still blink, and the meter will indicate
approximately 15.5V.

Page 250
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM285 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicate
approximately 15.5 volts.

Page 251
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM286 A 24 28.7

IM294 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 252
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM287 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". The meter will indicate approximately 15.5V.

Page 253
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM288 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicate
approximately 15.5V.

Page 254
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM290 A 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 255
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM291 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S" Indicator lamp should turn on, field lamp will still blink, and the
meter will indicate approximately 15.5V.

Page 256
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM292 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S" field lamp will still blink, and the meter will indicate approximately
15.5V.

Page 257
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM293 A 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 258
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM318 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Push the choke drive switch and the "Choke Drive Indicator Lamp" will turn on between 16.0V and 17.1V.

Page 259
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM341 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove sense lead and voltage rises to approximately 15.4 volts, reconnect sense lead. Connect C terminal of
regulator to C terminal on tester, and press Computer button, Voltage drops to 13.1 volts. Remove white test lead
from stator, 12 volt lamp comes on, voltage drops to 12 volts and field LED stays on (soft start). Remove Light
lead field light and Lamp light turn off.

Page 260
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM342 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect SENSE, the set point is 15.6+/-0.2V.
2. Disconnect Stator, the lamp light comes on, field light stays on and volts go to 12 volts..
3. Disconnect Light, the part stops regulation.
4. Push the Field Diode Button on the panel, the Field Diode LED is on.

Light Activated.

Page 261
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM345 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Caution - Note:• Connect DRIVER to tester “PD”
• IM345 has D-P terminal functions: D=Drive, P=Phase.
• D-P Type Regulators are immediately damaged if tested using procedure typical to common S-L type
regulators, where B+ Voltage would be applied to the D terminal position.

Page 262
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM350 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove sense lead and voltage rises to approximately 15.4 volts, reconnect sense lead. Remove white test lead
from stator, 12 volt lamp comes on, voltage drops to 12 volts and field LED stays on (soft start).

To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 263
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM358 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
No additional test required.

Page 264
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM369 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "Stator" field and lamp light comes on. Remove green test lead
from terminal marked "Light" field and lamp light goes off.

Using VRC2010: Connect external 3 Watt Lamp from Tester Battery Positive to the Voltage Regulator lamp
connection. Do not use the VRC2010 Lamp connection.

Page 265
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM381 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead and lamp comes on, voltage drops to 12.0 volts and field light stays on . Remove green
test lead from light and field light goes off.
Push the choke drive switch and the "Choke Drive Indicator Lamp" will turn on between 16.0V and 17.1V.

Page 266
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM465 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
• IM465 has D-P terminal functions: D=Drive, P=Phase.
• D-P Type Regulators are immediately damaged if tested using procedure typical to common S-L type
regulators, where B+ Voltage would be applied to the D terminal position.

• IM465 field brush is top / outer brush; (unlike many other Mitsubishi regulators).

Page 267
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM472HD A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the setpoint should be 15.6+/-0.2V.
2. Reconnect sense, and connect C to B-, the setpiont should be 12.7+/-0.2V.
3. Disconnect C, Disconnect Stator, the Lamp Indicator comes on.
4. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indicator should be on.

Light Activated
Soft Start & LRC function
With C-function
Over Voltage Lamp
Standard Lamp -- Without Output

Page 268
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM476 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect Sense lead and Light should turn ON. Set Point will be approximately 15.6 volts.
Reconnect the Sense lead and press the Over Voltage button. The light should be ON, and the set point will be
approximately 17.3 volts.

Page 269
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM480 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect SENSE, the set point should be 15.6 +/- 0.2V, and the Light comes on.
2. Reconnect SENSE, disconnect STATOR, the Light comes on.

Light Activated.

Page 270
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM498 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Stator, the Lamp comes on.
2. Reconnect Stator, push the ‘Choke Drive’ button on the panel, the Lamp comes on.

Light Activated.

Page 271
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM505 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect DRIVER to tester “PD”

Page 272
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM529 A 12 *14.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Use VRC2010 tester to complete RC voltage setpoint testing, Connect RC terminal to VRC2010 tester.
1. Adjust Comm Voltage switch to position 13, Setpoint is 12.9V.
2. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.
3. Adjust Comm Voltage switch to position 15, Setpoint is 14.8V.
* The 14.0V Set Point indicate above is the 'default VSet' (no vehicle PCM input).

Page 273
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM542 B 12 14.3

IM951 B 12 14.3

IM954 B 12 14.3

IM952 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove Red test lead from terminal marked "STA". Indicator light should turn on and the meter will indicate the
set point voltage.

Page 274
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM545 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Do not connect the FR terminal.
Disconnect the Stator terminal and the Light should turn ON.
Reconnect the Stator terminal, push the Over Voltage button, the light should turn ON, the set point will be
approximately 17.2 volts.

Page 275
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM545 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Stator, the Lamp Indicator comes on.
2. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indicator comes on.

Soft Start
2.5s LRC
Light Activated
Over Voltage, Under Voltage Lamp
Standard Lamp -- Without Output

Page 276
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM547 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the setpoint should me 15.5+/-0.2V.
2. Reconnect Sense, connect C to B-, the setpoint should be 13.1+/-0.2V.
3. Disconnect C, disconnect Stator, the Lamp Indication comes on.
4. Reconnect Stator, the Lamp Indication comes on

Light Activated.
Soft Start function.
6 seconds LRC
Field, Lamp short circuit protection
Standard Lamp -- Without Output

Page 277
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM564 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the setpoint should be 15.6V+/-0.2v, the Lamp Indicator comes on.
2. Reconnect Sense, disconnect Stator, the Lamp Indicator should be on.
3. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indicator comes on.

Light Activated.
Soft Start function
5.5s LRC
Over Voltage Lamp
Standard Lamp -- Without output

Page 278
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM604 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "STA". Indicator light should turn on and the meter will indicate set
point voltage.

Page 279
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM757 A 12 14.70

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 280
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM829 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Indicator lamp should turn on, field lamp will still blink, and the
meter will indicate approximately 15.5V.

Page 281
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM830 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Indicator lamp should turn on, field lamp will still blink, and the
meter will indicate approximately 15.5V. and the lamp will turn on.

Page 282
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM830HD A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp should still blink, indicator light will turn on and the
meter will indicate approximately 15.5 volts.

Page 283
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM831 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp should still blink and the meter will indicate
approximately 15.5 volts.

Page 284
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM832 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Indicator lamp should turn on, field lamp will still blink, and the
meter will indicate approximately 15.5V.

Page 285
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM836 A 14 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "A". Field lamp should still blink, indicator light will turn on and the
meter will indicate approximately 15.5V.

Page 286
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM840 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red sense lead & indicator light will turn on & Voltage will rise to 15.5 volts.

Page 287
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM843 A 24 28.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 288
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM844 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Connect C to B-, the setpoint should be 12.6-0.5/+0.4V.

Ignition Activated.
Trio input turns off charge indicator lamp.

Page 289
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM845 A 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect sense & voltage should rise to approximately 15.5 volts and light come on. Reconnect sense.
Connect black test lead to "C", voltage should drop to approximately 12.5 volts.
Push the choke drive switch and the "Choke Drive Indicator Lamp" will turn on between 16.0V and 17.1V.

Page 290
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM846 A 24 28.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 291
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM848 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove sense lead and voltage rises to approximately 15.4 volts, reconnect sense lead. Remove white test lead
from stator, 12 volt lamp comes on, voltage drops to 12 volts and field LED stays on (soft start). Remove Light
lead field light and Lamp light turn off.

Page 292
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM850 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect "C" terminal to tester, push Computer button and voltage will drop to approximately 12.5V. field lamp
stays on.
Push the choke drive switch and the "Choke Drive Indicator Lamp" will turn on between 16.0V and 17.1V.

Page 293
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM851 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "Stator" field and lamp light comes on and voltage will indicate 12 volts.
Remove green test lead from terminal marked "Lamp" and lamp light goes off. Remove red test lead from terminal marked
"Ignition" and field light goes off.
* Connect black lead to "C" computer terminal and field lamp will stay on and voltage will read approximately 12.7 volts
Using VRC2010: Push the choke drive switch and the "Choke Drive Indicator Lamp" will turn on between 16.0V and 17.1V.

Page 294
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM853 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked “Stator” field, lamp light comes on and Voltage will incate 12 Volts.
Remove green test lead from terminal marked “Lamp” and lamp light goes off. Remove red test lead from
terminal marked “Ignition” and the field light goes off.

Page 295
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IM854 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnecting Sense turns light on.

Page 296
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN209 A 12 14.5

IN210 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 297
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN209 A 12 14.5

IN210 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 298
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN215 A 12 14.6

IN452 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect C terminal of regulator to C terminal on tester, and press Computer button, Voltage will read 12.6V.
Remove white test lead to confirm charge indicator light function.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.
IN452 - No connection on black test lead labeled “C” on IN215, “D” on IN452.

Page 299
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN218 A 12 14.2

IN217 A 24 27.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "B+.". The meter should indicate approximately 17V on the IN218
regulator and 28V on the IN236 regulator.

Page 300
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN219 A 12 14.5 IN225 A 12 14.5

IN221 A 12 14.5 IN227 A 12 14.5

IN222 A 12 14.5 IN251 A 12 14.5

IN224 A 12 14.5 IN252 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 301
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN220 A 12 14.4 IN436 A 12 14.0

IN226 A 12 14.4 IN437 A 12 14.4

IN250 A 12 14.4 IN439 A 12 14.4

IN256 A 12 14.4 IN444 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove test lead from the terminal marked "*". The indicator light will turn on and the meter will indicate
approximately 12V and the field lamp will remain fully on (this is the soft start mode of the regulator).
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.

NOTE on Stator: Transpo (White test lead) / OE (Red test lead)

Page 302
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN220E A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove test lead from the terminal marked "*". The indicator light will turn on and the meter will indicate
approximately 14.6v. and the field lamp will remain fully on.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.

Page 303
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN223 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove test lead from terminal marked "P" Indicator light should turn on, field lamp will remain on, and the meter
will indicate approximately 12.0V.

Page 304
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN228 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 305
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN229 A 12 14.1

IN229HD A 12 14.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

NOTE: When testing the Transpo IN229 or the Original Equipment voltage regulators, the short circuit light may
flash and the meter will indicate the set point voltage.

Page 306
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN230 A 12 14.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Indicator light will come on and voltage will rise to approximately
16 volts.

NOTE: When testing the Transpo IN230 or the Original Equipment voltage regulators, the short circuit light may
flash and the meter will indicate the set point voltage.

Page 307
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN231 A 12 14.4

IN232 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 308
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN233 A 24 28

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 309
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN234 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". Field lamp will still blink, and the meter will indicate
approximately 15.0V.

Page 310
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN235 A 12 14.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 311
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN248 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Push the Choke Drive button on the panel, the Choke light comes on.

Ignition Activated

Page 312
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN249 A 12 14.65

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

A circuit,low side drive

Page 313
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN253 A 12 14.5 IN431 A 12 14.5

IN254 A 12 14.5 IN435 A 12 14.5

IN255 A 12 14.5

IN429 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 314
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN257 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove test lead from the terminal marked "*". The indicator light will turn on and the meter will indicate
approximately 12V and the field lamp will remain fully on (this is the soft start mode of the regulator).
Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on
between 16.0V and 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.

NOTE on Stator: Transpo (White test lead) / OE (Red test lead)


REFER TO PRODUCT GROUP IN-29, PAGE 341-A FOR REGULATOR'S DIAGRAM

Page 315
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN258 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
• When Ignition wire is disconnected from the regulator, VSet reading drops to default 12V.
• When both the Field and Stator connections are disconnected from regulator, lamp illuminates.

Note: This regulator’s light circuit functions when a combined condition exists ... Loss of the Stator signal and B+
Voltage drops below 14.0V (approx).

• IN258 is an "A" circuit, low side drive regulator.


• D-IG-L Terminals (D = dummy / no function)
• VSet 14.4V (+/- 0.2V).
• Field rating 5-Amps.
• Ignition activated.

Page 316
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN265 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Stator, the Lamp Indication comes on.

Ignition Activated.

Page 317
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN266 A 24 28.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Ignition Activated.

Page 318
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN277 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect “Stator” terminal, “Light” comes on, voltage goes to 12 Volts and field light stays on. Remove “Light”
terminal, Volts will read 12 Volts and field light will go off.

Page 319
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN289 A 12 13.8

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the setpoint should be about 14.5V. lamp on
2. Reconnect Sense, disconnect Stator, the Light should be on.

A circuit, low side drive


with softstart
with LRC
IGN actived

Page 320
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN302 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked “S”, lamp turns on and voltage remains the same. Reconnect.
Remove white test lead from terminal marked stator, lamp light turns on an voltage goes to 12 volts with field light
on.

Page 321
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN3054 B 12 14.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the field lamp should blink, check the reading on the meter, it should be 13.9+/-0.2v.
2. Disconnect Stator, the light should be ON, and voltage reads 12.0 volt and field light stays on.
3. Disconnect Ignition, the part should stop regulation.
4. Push the Field Diode Button on the panel, the Field Diode lamp should be on.

Ignition Activated.

Page 322
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN317 A 12 14.35

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
No connection to the FM Out terminal.
Push Over Voltage button, Light should turn ON, set point is approximately 17.2 volts.
Push Choke button, Choke Light should turn ON.

Page 323
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN330 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Ignition Activated.

Page 324
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN332 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Stator, the Lamp Indication comes on.

Ignition Activated.
Soft start.
9 seconds LRC.
Under voltage Lamp

Page 325
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN348 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Stator, the Lamp Indicator comes on.
2. Reconnect Stator, Push the Choke Drive button on the panel, the Choke Drive Indicator should be on.

Ignition Activated
Soft Start
Under Voltage Lamp
P-IG-L Terminal Function
Active Lamp -- With Output

Page 326
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN369 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
The FR terminal is not connected.
Disconnect the Sense terminal, the light should be ON, and the set point will read approximately 14.5 volts.
Push the Over Voltage button, the set point should read approximately 17.3 volts.

Page 327
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN373 A 24 28.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Stator, the Lamp Indicator comes on, and the Field Circuit LED comes dim.
2. Reconnect Stator, push the Choke Drive button on the panel, the Choke Drive Indicator comes on.

Ignition Activated
Active Lamp -- With Output
With Soft Start

Page 328
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN434 A 12 14.3

IN438 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove test lead from the terminal marked "*". The indicator light will turn on and the meter will indicate
approximately 12V and the field lamp will remain fully on (this is the soft start mode of the regulator).
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

NOTE on Stator: Transpo (White test lead) / OE (Red test lead)

Page 329
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN441 A 14 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked Stator. Indicator light will turn on and meter will indicate 12V; Field
circuit light stays on. Reconnect. Remove red test lead from terminal marked "IG"; field lamp should turn off
meter will indicate 12V.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

NOTE on Stator: Transpo (White test lead) / OE (Red test lead)

Page 330
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN442 A 12 14.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked stator. Indicator light will come on.

Page 331
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN445 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
* With regulator ‘ON’, connect "C" terminal to tester, push Computer button on tester and Voltage should drop to
12.5 volts.
To check for over Voltage, push the "Over Voltage" button and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 332
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN447HD A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect stator, the light is ON and the regulator is function.
2. Push the Over Voltage Button on the pannel, the light will be ON.
3. Push the Field Diode Button on the pannel, the field diode LED will be ON.

Ignition Activated.

Page 333
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN449 A 12 14.5

IN440 A 12 14.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on
between 16.0V and 17.1V.

Page 334
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN450 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

* NOTE: On OE Regulator connect a Red test lead to stator (STA)

Page 335
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN453 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white lead from stator and voltage should drop to 12.0V and 12V lamp should come on. Field circuit
lamp stays on.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 336
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN453HD A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect stator, the field light is ON and the regulator goes to 12V. Reconnect stator.
2. Disconnect Sense, the setpoint is 14.5+/-0.2V and light comes on. Reconnect Sense.
3. Push the Over Voltage Button on the pannel, the light will be ON.
4. Push the Field Diode Button on the pannel, the field diode LED will be ON.

Ignition Activated. Remove Ignition, voltage goes to 12V and light is off.

Page 337
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN454 B 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the Lamp Indicator comes on.

Stator or Light Activated.


Under Voltage Lamp
Soft Start & LRC function.

Page 338
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN455 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S" and lamp turns on and voltage remains the same.

Page 339
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN460 A 24 28.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
• Remove white lead from stator connection and note the following:
... Indicator lamp should light and voltage stay the same

• Using VRC2010 to check for ‘Over Voltage’:


... Push the ‘Field Diode’ switch and the ‘Field Diode Lamp’ will turn on.

• Ignition (IGN) activated.


• Stator input turns off the Light.
• Standard Lamp Circuit - No Output
• Field Rating 3-Amps.
• Typical Vsat 1.20-Volts, @ 3-Amps, 24-Volts.

Page 340
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN550 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 341
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN551 B 12 14.3 IN822 B 12 14.3

IN558 B 12 14.3 IN579 B 12 14.3

IN560 B 12 14.3

IN562 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove black test lead from terminal marked "STA". Indicator light should turn on and the meter will indicate the
set point voltage.

Page 342
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN554 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 343
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN555 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove the white test lead from the terminal marked stator, The indicate approximately 12V. The field lamp will
remain fully on, (This is the soft-start mode of the regulator.)

Page 344
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN567 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 345
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN568 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 346
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN569 B 12 14.3

IN578 B 12 14.3

IN589 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove black test lead from terminal marked "STA". Indicator light should turn on and the meter will indicate the
set point voltage.

Page 347
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6001 B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
• Set Field Load Switch to 0.5 Amp only.
• Disconnect the Sense Lead and verify Light Turns On.

• S-IG-L Terminals
• Ignition Activated.
• Without LRC
• Active Lamp – With Output

Page 348
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6002 B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
• Set Field Load Switch to 0.5 Amp only.
• Disconnect the Sense Lead and verify Light Turns On.
• No over voltage lamp

• S-IG-L Terminals
• Ignition Activated
• Without LRC
• Standard Lamp – No Output

Page 349
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6003 B 12 15.0V

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
• Set Field Load Switch to 0.5 Amp only
• Disconnect the Sense Lead and verify Light Turns On with Delay
• This Regulator without Over Voltage Lamp Indication

• S-F-L Terminals
• Stator Activated.
• LRC 9-Seconds (to 400HZ)
• Standard Lamp – No Output

Page 350
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6004 B 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
• Set Field Load Switch to 0.5 Amp only
* Connect C terminal to B-, verify Set-Point is 12.8 V +/- 0.2V

• IG-C-L-FR Terminals
• Standard Lamp Function - No Output
• No Output LRC

Page 351
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6009 B 12 14.8

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
• Set Load Amperage Switch to 0.5 Position Only
• No over voltage lamp
• Regulator without Over Voltage Lamp Indication

• F-L Terminals
• Lamp Activated.
• LRC 2-Seconds (to 400HZ)
• Standard Lamp Function – No Output

Page 352
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN601 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 353
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6015 B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the setpoint should be 13.9+/-0.2V and the Lamp Light comes on.
2. Reconnect Sense, and disconnect Stator, the Lamp Light comes on, and the field Light is dim.

Ignition Activated.

Page 354
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN602 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove black test lead from terminal marked "STA". Indicator light turn on and the meter will indicator light
should turn on and the meter will indicate the set point voltage.

Page 355
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6301 B 12 14.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
• Set Field Load Switch to 0.5 Amp only.
• Disconnect the Sense Lead and verify Light Turns On.

• IG-S-L-M(FR) Terminals
• Ignition Activated
• LRC 6-Seconds, Full Range
• Multi-Step TempCo
• Standard Lamp – No Output

Page 356
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6302 B 12 14.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1.Set Field Load Switch to 0.5 Amp only.
2.This regulator is not tested for Over Voltage Lamp or Loss of Sense
3.The RLO Function is similar to the RC control function found in PCM controlled Ford 6G systems and GM RVC
systems.When the vehicl ECM takes command of the regulator’s RLO circuit,the alternator Voltage follows the PWM signal
duty cycle;the regulation Voltage will range between 11.80V and 14.99V as needed

• IG-RLO-L-M Terminals
• Ignition Activated
• LRC 6-Seconds, Full Range
• Multi-Step TempCo (unless in RLO mode)

Page 357
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6304 B 12 14.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
• Set Field Load Switch to 0.5 Amp only.
• Disconnect the Sense Lead and verify Light Turns On (slight delay), reconnect Sense Lead.
• Disconnect Ignition Lead, voltage goes to 12 volts, Field Light turns off and Lamp Light turns off.

• IG-S-L-M(FR) Terminals
• Ignition Activated
• LRC 6-Seconds, Full Range
• Multi-Step TempCo
• Standard Lamp – No Output

Page 358
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6304 B 12 14.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
• Set Field Load Switch to 0.5 Amp only.
• Disconnect the Sense Lead and verify Light Turns On

... Need to verify all !!!!

• IG-S-L-M(FR) Terminals
• Ignition Activated
• LRC 6-Seconds, Full Range
• Multi-Step TempCo
• Standard Lamp – No Output

Page 359
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6308 B 12 14.45

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Stator, the Lamp Indicator comes on and the Field Circuit LED will dim.

Light Activated
Soft Start
2.2s LRC

Page 360
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6315 B 12 14.35

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Connect C terminal to the B- of VRC2010, the set point should be 12.7+/-0.2V.
2. Remove C, disconnect Stator, the Light should be on, the regulator continues regulating.
3. Connect Stator, disconnect Ignition, the regulator stops regulating.

Ignition Activated.

Page 361
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6322 B 12 14.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
• Set Field Load Switch to 0.5 Amp only.
• No Over Voltage Lamp
• No RLO terminal test default voltage test only

• IG-RLO-L-M Terminals
• Ignition Activated
• LRC 6-Seconds, Full Range
• Multi-Step TempCo (unless in RLO mode)

Page 362
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6324 B 12 13.8

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Use VRC2010 tester to complete RC voltage setpoint testing,Connect RC terminal to VRC2010 tester.
1. Adjust Comm Voltage switch to position 13, Setpoint is 11.8V.
2. Adjust Comm Voltage switch to position 14, Setpoint is 13.3V.
3. Adjust Comm Voltage switch to position 15, Setpoint is 14.4V.
* The 13.8V Set Point indicate above is the 'default VSet' (no vehicle PCM input).

Stator or RVC Activated.

Page 363
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6329 B 12 13.8

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Use VRC2010 tester to complete RC voltage setpoint testing:
1. Connect RC terminal to VRC2010 tester.
2. Adjust Comm Voltage switch to position 13, Setpoint is 11.8.
3. Adjust Comm Voltage switch to position 14, Setpoint is 13.3V.
4. Adjust Comm Voltage switch to position 15, Setpoint is 14.4V.
* The 13.8V Set Point indicate above is the 'default VSet' (no vehicle PCM input).

Stator or RVC Activated

Page 364
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6335 B 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
• Set Field Load Switch to 0.5 Amp only
• Connect the C Terminal to B-, the set point should drop to 12.7 Volts
• Remove Stator wire and the Light should turn ON

• IG-C-L-FR Terminals• Ignition Activated• LRC 11-Seconds (to 400HZ)


• Standard Lamp – No Output
• Due to the long delay, automatic spin bench testers should be setup to be in the ‘Wait Always’ mode. Not doing
so may result in an inaccurate performance reading.

Page 365
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6343 B 12 13.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect Sense, the setpoint should be 13.85+/-0.2V, then reconnect.
Use VRC2010 tester to complete RC voltage setpoint testing,Connect RC terminal to VRC2010 tester.
1. Adjust Comm Voltage switch to position 13, Setpoint is 12.9V.
2. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.
3. Adjust Comm Voltage switch to position 15, Setpoint is 14.8V.
* The 13.5V Set Point indicate above is the 'default VSet' (no vehicle PCM input).

RC or STATOR activated

Page 366
TRANSPO TESTER INSTRUCTIONS
for type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6349 B 12 13.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect Sense, the setpoint should be 13.85+/-0.2V, then reconnect.
Use VRC2010 tester to complete RC voltage setpoint testing,Connect RC terminal to VRC2010 tester.
1. Adjust Comm Voltage switch to position 13, Setpoint is 12.9V.
2. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.
3. Adjust Comm Voltage switch to position 15, Setpoint is 14.8V.
* The 13.5V Set Point indicate above is the 'default VSet' (no vehicle PCM input).

RC or STATOR activated

Page 367
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6365 B 12 14.35

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Stator, the Lamp Indicator comes on.
2. Reconnect Stator, connect C terminal to B-, the setpoint should be 12.7+/-0.2V.

Ignition Activated.
C function
Standard Lamp Function -- Without Output.

Page 368
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN6366 B 12 14.46

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Stator, the Lamp Indicator comes on.
2. Reconnect Stator, connect C terminal to B-, the setpoint should be 12.8+/-0.2V.

Ignition Activated.
C function
12 seconds LRC
Standard Lamp -- Without Output

Page 369
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN821 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove black test lead from the terminal marked "STA". The indicator light should turn on and the meter will
indicate the set point voltage.

Page 370
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN8315 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 371
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN920 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove the white test lead from the terminal marked stator, the indicator light will turn on and the meter will
indicate approximately 12V. The field lamp will remain fully on . (This is the soft -start mode of the regulator)

NOTE: Transpo (White test lead) / OE (Red test lead)

Page 372
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN9252 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

D+ Activated/Excited.

Page 373
TRANSPO TESTER INSTRUCTIONS
for NIPPONDENSO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IN9254 A 24 27.9

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

D+ Activated/Excited.

Page 374
TRANSPO TESTER INSTRUCTIONS
for PARIS RHONE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IP122 A 12 14.4

IP152 A 12 14.2

IP1639 A 12 14.4

IP1655 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove black test lead from the blue wire of the regulator . Indicator light should turn on and meter will still
indicate the set point voltage.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 375
TRANSPO TESTER INSTRUCTIONS
for PARIS RHONE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IP123 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove black test lead from blue wire. Indicator light should turn on and voltage will remain the same.

Page 376
TRANSPO TESTER INSTRUCTIONS
for PARIS RHONE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IP125 A 12 14.6

IP126 A 24 28.4

IP955 A 24 28.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 377
TRANSPO TESTER INSTRUCTIONS
for PARIS RHONE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IP127 A 12 14.7

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 378
TRANSPO TESTER INSTRUCTIONS
for PARIS RHONE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IP130 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from the stator wire of the regulator. indicator light should turn on and meter will still
indicate the set point voltage.

Page 379
TRANSPO TESTER INSTRUCTIONS
for PARIS RHONE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IP135 A 12 14.3

IP135B A 12 14.3

IP129B A 24 27.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 380
TRANSPO TESTER INSTRUCTIONS
for PARIS RHONE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IP137 A 12 14.6

IP1903 A 12 14.6

IP2700 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 381
TRANSPO TESTER INSTRUCTIONS
for PARIS RHONE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IP1652 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from the blue wire of the regulator. Indicator light should turn on and meter will read
approximately 12 volts.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 382
TRANSPO TESTER INSTRUCTIONS
for PARIS RHONE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IP1926 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 383
TRANSPO TESTER INSTRUCTIONS
for PARIS RHONE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IP735B A 12 14.3

IP729B A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 384
TRANSPO TESTER INSTRUCTIONS
for PARIS RHONE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IP736 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 385
TRANSPO TESTER INSTRUCTIONS
for LADA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IR674 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 386
TRANSPO TESTER INSTRUCTIONS
for SEV MARCHAL type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IS219 B 12 14.2

IS219A B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 387
TRANSPO TESTER INSTRUCTIONS
for SEV MARCHAL type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IS222 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 388
TRANSPO TESTER INSTRUCTIONS
for SEV MARCHAL type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IS223 B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 389
TRANSPO TESTER INSTRUCTIONS
for SEV MARCHAL type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IS301 B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 390
TRANSPO TESTER INSTRUCTIONS
for SAWAFUJI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IW700 A 24 28.5

IW701 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove test lead from Stator terminal and light will come on; reconnect test lead to Stator terminal. Remove test
lead from Ignition terminal, field light will stop flashing and voltage goes to default. (see note)

Note: Remove test lead from Ignition terminal, field light will stop flashing and voltage goes to 12V for (IW701)
and 24V (IW700).

Page 391
TRANSPO TESTER INSTRUCTIONS
for MAGNETI-MARELLI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IX106 A 12 14.2

IX107 A 12 14.2

IX108 A 24 28.0

IX109 A 24 28.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 392
TRANSPO TESTER INSTRUCTIONS
for MAGNETI-MARELLI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IX110 A 12 14.5

IX111 A 24 28.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 393
TRANSPO TESTER INSTRUCTIONS
for MAGNETI-MARELLI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IX110CN A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 394
TRANSPO TESTER INSTRUCTIONS
for MAGNETI-MARELLI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IX118 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red lead from stator and voltage will remain the same. Field lamp will flicker and 12V lamp come on.

Page 395
TRANSPO TESTER INSTRUCTIONS
for MAGNETI-MARELLI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IX121 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from stator terminal. Indicator light will come on. Field light will stay on and meter will
read approximately 12 volts.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 396
TRANSPO TESTER INSTRUCTIONS
for MAGNETI-MARELLI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IX123 A 12 14.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from stator terminal. Indicator light will come on. Field light will stay on and meter will
read approximately 12 volts.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.

Page 397
TRANSPO TESTER INSTRUCTIONS
for MAGNETI MARELLI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IX124 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Stator, the Lamp Indicator should be on.
2. Reconnect Stator, push the Choke Drive button on the panel, the Choke Drive Indicator should be on.

IL or Stator Activated.
Active Lamp -- With Output

Page 398
TRANSPO TESTER INSTRUCTIONS
for MAGNETI-MARELLI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IX127 A 12 14.2

IX128 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from stator terminal . Indicator light will come on. Field light will stay on and meter will
read approximately 12 volts.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 399
TRANSPO TESTER INSTRUCTIONS
for MAGNETI-MARELLI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IX131 A 12 *14.0

IX131HD A 12 *14.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect RC terminal of regulator to RCV terminal on tester. Connect LI terminal of regulator to LI terminal on tester
1. Adjust Comm Voltage switch to position 13, Setpoint is 12.9V.
2. Adjust Comm Voltage switch to position 14, Setpoint is 14.0V.
3. Adjust Comm Voltage switch to position 15, Setpoint is 14.8V.
* The 14.0V Set Point indicated above is the 'default VSet' (no vehicle PCM input).

Page 400
TRANSPO TESTER INSTRUCTIONS
for MAGNETI-MARELLI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IX4004 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 401
TRANSPO TESTER INSTRUCTIONS
for type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IX597 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

A circuit
without LRC
with choke drive

Page 402
TRANSPO TESTER INSTRUCTIONS
for MANDO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IY028 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 403
TRANSPO TESTER INSTRUCTIONS
for MANDO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IY058 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from "S" terminal. Voltage will go up to approximately 15.5V.

Page 404
TRANSPO TESTER INSTRUCTIONS
for type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IY145 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the setpoint should be 15.3+/-0.2v.

Light Activated.

Page 405
TRANSPO TESTER INSTRUCTIONS
for MANDO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IY146 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect SENSE, the setpoint should be 15.3+/-0.2V,
2, Reconnect SENSE, then connect C terminal to the B-, the setpoint should be 12.7+0.2v/-0.3v.

Light Activated.

Page 406
TRANSPO TESTER INSTRUCTIONS
for MANDO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IY289 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the setpoint should be 15.6+/-0.2V.

Ignition Activated.

Page 407
TRANSPO TESTER INSTRUCTIONS
for MANDO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IY422 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Disconnect sense (Red) lead, voltage should go to 15.5V.

Page 408
TRANSPO TESTER INSTRUCTIONS
for MANDO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IY510 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 409
TRANSPO TESTER INSTRUCTIONS
for MANDO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IY785 A 12 14.6

IY786 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 410
TRANSPO TESTER INSTRUCTIONS
for MANDO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IY903 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from "S" terminal. Voltage will go up to approximately 15.5V.

Page 411
TRANSPO TESTER INSTRUCTIONS
for NIKKO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IZ226 A 24 27.5

IZ227 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 412
TRANSPO TESTER INSTRUCTIONS
for NIKKO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

IZ228 A 24 28.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 413
TRANSPO TESTER INSTRUCTIONS
for LEECE NEVILLE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

L1666280 A 12 13.8

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 414
TRANSPO TESTER INSTRUCTIONS
for LEECE NEVILLE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

L5003 B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 415
TRANSPO TESTER INSTRUCTIONS
for LEECE NEVILLE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

L5016 B 12 14.2

L5028 B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 416
TRANSPO TESTER INSTRUCTIONS
for LEECE NEVILLE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

L5022 A 12 14.2 L5042HD A 24 27.5

L5042 A 24 27.5

L5062 A 32 37.5

L5078 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 417
TRANSPO TESTER INSTRUCTIONS
for LEECE NEVILLE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

L77973AC A 12 14.2

L97300AC A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from the regulator's stud marked "Stator". Field lamp should turn off and the meter will
indicate low voltage.

Page 418
TRANSPO TESTER INSTRUCTIONS
for LEECE NEVILLE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

L77973S A 12 14.2

L78855S A 24 27.5

L78935S A 32 37.5

L97300S A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from regulator's stud marked "TRIO" or "IGN". Field lamp should turn off and the meter
will indicate low voltage.

Page 419
TRANSPO TESTER INSTRUCTIONS
for LEECE NEVILLE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

L79000 A 12 14.2 L79000S A 12 14.2

L79000HD A 12 14.2 L79000X A 12 14.2

L79000HDP A 12 14.2 L95019 A 12 14.2

L79000LH A 12 14.2 L96852 A 24 27.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from regulator wire marked "TRIO". Filed lamp should turn off and the meter will indicate
low voltage.

Page 420
TRANSPO TESTER INSTRUCTIONS
for LEECE NEVILLE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

L79000AC A 12 14.2

L96345AC A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from regulator wire marked "Stator". Filed lamp should turn off and the meter will indicate
low voltage.

Page 421
TRANSPO TESTER INSTRUCTIONS
for LEECE NEVILLE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

L79350S A 24 27.5

L97050S A 32 37.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from regulator wire marked "TRIO". Filed lamp should turn off and the meter will indicate
low voltage.

Page 422
TRANSPO TESTER INSTRUCTIONS
for LEECE NEVILLE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

L95300S A 24 28.0

L99500S A 12 14.2

L99825S A 24 27.5

L99850S A 32 37.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

NOTE: Connect B+ to the three stator Terminals if no IGN terminal is used

Page 423
TRANSPO TESTER INSTRUCTIONS
for LEECE NEVILLE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

L99920 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from “Stator” terminal and regulator turns off.

Page 424
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M3118C A 24 28.5

M3118 A 24 28.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 425
TRANSPO TESTER INSTRUCTIONS
for VALEO / MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-036 B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 426
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-050A A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from yellow wire of the regulator marked as "Stator". Field lamp should turn off and the
meter will indicate low voltage.

Page 427
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-104A A 12 14.2

M5-121A A 12 14.2

M5-179A A 24 28.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

NOTE:
The above are "SCR" type regulators. They cannot be tested on Transpo's regulator tester due to a requirement
of an adapter. To test them simply install them in the appropriate alternator and check for regulation.

Page 428
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-113A B 12 14.2

M5-122A B 12 14.4

M5-216A B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from yellow wire of the regulator. Indicator light should turn on and the meter will indicate
the set point voltage.

Page 429
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-123A A 24 28.0

M5-128A B 32 38.4

M5-234A B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 430
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-130A B 12 15.2

M5-130 B 12 15.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

NOTE: * Regulators with One (1) yellow wire: M5-30A, M5-42A, M5-130A, M5-135, M5-141A
** Regulators with Two (2) yellow wires: M5-28A, M5-50A

Page 431
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-137A B 12 15.2

M5-142A B 12 14.2

M5-184A B 24 29.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 432
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-143A B 12 14.2 M5-222A B 12 15.3

M5-150A B 12 14.2 M5-185A B 24 29.2

M5-206A B 12 15.3

M5-218A B 12 15.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

NOTE: * Regulators with One (1) Yellow wire: M5-143A, M5-150A, M5-206A, M5-218A, M5-222A, M5-185A

Page 433
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-146 B 12 15.2

M5-146A B 12 15.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 434
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-149A B 24 28.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "S". field lamp should still blink and the meter will indicate
approximately 29.5v.

Page 435
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-151SA6 B 6 7.8 M5-151SA32 B 32 37.5

M5-151SA8 B 8 9.6

M5-151SA12 B 12 14.2

M5-151SA24 B 24 27.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove the white test lead from the yellow wire of the regulator marked "stator". Field lamp should turn off and
the meter will indicate low voltage. On models with indicator light connection, removal of stator lead form
regulator should cause the light to turn on and meter indicates low voltage.

NOTE * Not used for 24V and 32V

Page 436
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-156A B 12 14.2 M5-177A B 24 28.0

M5-157A B 24 29.2 M5-191A B 12 14.2

M5-161A B 24 28.4 M5-211A B 12 14.2

M5-163A B 24 28.0 M5-232A B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 437
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-158A B 24 29.2

M5-162A B 24 28.4

M5-166A B 24 28.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 438
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-159A B 24 29.2

M5-227A B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 439
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-160A B 24 29.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

REGULATOR CONNECTION TEST LEAD FUNCTION


BLACK BLACK BATTERY NEGATIVE
RED RED TRIO, IGNITION, AUX
GREEN YELLOW FIELD
YELLOW NO CONNECTION

Page 440
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-164A B 24 28.4

M5-167A B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 441
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-165A B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 442
TRANSPO TESTER INSTRUCTIONS
for VALEO / MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-170A B 12 14.4

M5-742A B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 443
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-172A B 12 14.2

M5-169A B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 444
TRANSPO TESTER INSTRUCTIONS
for VALEO / MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-180A B 12 14.2

M5-241A B 12 14.2

M5-763A B 12 14.1

M5-764A B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 445
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-181A B 12 15.0

M5-192A B 12 14.2

M5-201A B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 446
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-193A B 12 14.4

M5-214A B 12 14.4

M5-240A B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 447
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-196A B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 448
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-197A B 12 15.0

M5-207A B 12 14.2

M5-250A B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 449
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-198A B 12 15.0

M5-200A B 12 14.2

M5-244A B 12 13.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 450
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-200SA6 B 6 7.8 M5-200SA32 B 32 37.5

M5-200SA8 B 8 9.5

M5-200SA12 B 12 14.2

M5-200SA24 B 24 27.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from the yellow wire of the regulator marked "Stator ". Field lamp should turn off and the
meter will indicate low voltage. On regulators with indicator light, light should also turn on when stator is removed
from the regulator.

* NOTE: Not used on 24V & 32V Regulators

Page 451
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-203A B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 452
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-204A B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked with "*". Field lamp should still blink and the meter will indicate
approximately 15.3 v.

Page 453
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-208A B 24 29.2

M5-209A B 24 28.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Measure between regulator's yellow and red wire using an ohm meter (without a connection to the voltage
regulator tester). Approximately 150 Ohms must be measured.

Page 454
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-215A A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 455
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-217A B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 456
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-224A B 12 14.4

M5-245A B 12 13.8

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from yellow wire of the regulator marked as "Stator". Field lamp should turn off and the
meter will indicate low voltage.

Page 457
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-225A A 12 14.4

M5-225 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 458
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-226A A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 459
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-228A B 12 14.1 M5-223A B 12 13.8

M5-138A B 12 15.2

M5-174A B 12 14.1

M5-205A B 12 14.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 460
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-230A B 12 14.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 461
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-233A B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from yellow wire of the regulator marked as "Stator". Field lamp should turn off and the
meter will indicate low voltage.

Page 462
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-237A B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from stator wires. The field lamp should stay on and the meter will indicate high voltage.
Connect red test lead to the post marked "no connection". Regulator will regulate at the specified set point
voltage.

Page 463
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-239A B 12 13.8

M5-274A B 36 38.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 464
TRANSPO TESTER INSTRUCTIONS
for type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-2471 A 24 27.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

A circuit,low side drive


STA actived

Page 465
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-247A B 24 27.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from yellow wire of the regulator marked as "Stator". Field lamp should turn off and the
meter will indicate low voltage.

NOTE: Original Equipment Regulator no. 5-247 is an "A" circuit compared to Transpo's "B" circuit.

Page 466
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-249A B 24 28.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from yellow wire of the regulator marked as "Stator". Field lamp should turn off and the
meter will indicate low voltage.

NOTE: Original Equipment Regulator no. 5-249 is an "A" circuit compared to Transpo's "B" circuit.

Page 467
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-251 A 24 26.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
DO NOT CONNECT BOTH SENSE LEADS AT THE SAME TIME.

• VSET1: Disconnect Sense (Purple Lead Wire) ... Voltage Regulation 28.00V +/- 0.5V

• VSET2: Connect Regulator as shown; Use Resistor 5K Ohm... Voltage Regulation 26.5V +/- 0.5V

NOTE: THE VOLTAGE IS BELOW METER RANGE WITHOUT USING A RESISTOR ON YELLOW WIRE.
REGULATOR IS FACTORY SET AT 26.5V. WE DO NOT RECOMMEND TURNING VARIABLE
RESISTOR UNTIL INSTALLED ON VEHICLE.

Page 468
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-265 A 12 14.4

M5-266 A 12 14.4

M5-269 A 24 28.4

M5-270 A 24 28.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 469
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-26A B 12 15.2 M5-153A B 12 15.0

M5-27A B 24 29.2 M5-183A B 24 29.2

M5-92A B 12 15.2

M5-93A B 24 29.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 470
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-280A A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from yellow wire of the regulator marked as "Stator". Field lamp should turn off and the
meter will indicate low voltage.

Page 471
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-292A A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from terminal marked "Stator". Field lamp should turn off and the meter will indicate
approximately 12v.

Page 472
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-29A B 12 15.0 M5-152A B 12 14.2

M5-48A B 24 29.2 M5-182A B 24 29.2

M5-63A B 24 29.2 M5-242(A) B 12 14.2

M5-151A B 12 15.0 M5-248A B 24 28.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 473
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-313 A 12V 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
disconnect Sense, check the secondary voltage, it is 15.4+/-0.2V.

Light Activated.

Page 474
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-313CN A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the set point should be 15.4+/-0.2V.

Light Activated.

Page 475
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-329A A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 476
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-332 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. test with VRC2010 disconnect sense, the set point(DMM) is about 15.4V, the Lamp indicator is on

A circuit

Page 477
TRANSPO TESTER INSTRUCTIONS
for VALEO / MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-508 B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 478
TRANSPO TESTER INSTRUCTIONS
for VALEO / MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-509 B 12 14.1

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 479
TRANSPO TESTER INSTRUCTIONS
for VALEO / MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-515 B 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove black test lead from terminal marked "D+". Indicator will come on.

Page 480
TRANSPO TESTER INSTRUCTIONS
for MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-61A B 24 28.0 M5-136A B 12 14.2

M5-74A B 32 39.2 M5-147A B 12 15.00

M5-79A B 12 14.2 M5-148A B 24 28.0

M5-94A B 32 38.4 M5-154A B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 481
TRANSPO TESTER INSTRUCTIONS
for VALEO / MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-762 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 482
TRANSPO TESTER INSTRUCTIONS
for VALEO / MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M5-768 B 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "D+". Indicator light will come on.

Page 483
TRANSPO TESTER INSTRUCTIONS
for VALEO / MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M506 A 12 15.0

M508 A 12 15.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 484
TRANSPO TESTER INSTRUCTIONS
for VALEO / MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M507 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 485
TRANSPO TESTER INSTRUCTIONS
for VALEO / MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M509 A 12 14.4

M510 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 486
TRANSPO TESTER INSTRUCTIONS
for VALEO / MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M511 A 14 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 487
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M511V A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Trio Excited.

Page 488
TRANSPO TESTER INSTRUCTIONS
for VALEO / MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M512 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white lead from stator and voltage should drop to 12.0v. lamp should come on. Field circuit lamp stays
on.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 489
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M512HD A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Push the Over Voltage button on the panel, the Lamp Indicator comes on.
2. Disconnect Stator, the Lamp Indicator comes on.

Ignition Activated
With Soft Start
Over Voltage and Under Voltage lamp

Page 490
TRANSPO TESTER INSTRUCTIONS
for VALEO / MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M513 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white lead from stator and voltage should drop to 12.0v and 12V lamp should come on. Field circuit lamp
stays on.
To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on between 16.0V
and 17.1V.

Page 491
TRANSPO TESTER INSTRUCTIONS
for VALEO / MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M515 B 12 14.8

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 492
TRANSPO TESTER INSTRUCTIONS
for VALEO / MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M517 B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove “White” lead from “Stator”, meter will read 12.0 volts field light will come on and 12 volt lamp will come
on. Remove “Lamp” terminal and field light will go out and lamp light will go out.

Page 493
TRANSPO TESTER INSTRUCTIONS
for VALEO / MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M519 B 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove “White” lead from “Stator”, meter will read 12.0 volts field light will come on and 12 volt lamp will come
on. Remove “Lamp” terminal and field light will go out and lamp light will go out.

Page 494
TRANSPO TESTER INSTRUCTIONS
for VALEO MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M520 B 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ

Page 495
TRANSPO TESTER INSTRUCTIONS
for VALEO MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M523 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ

• Terminal Designation 16E-15 (Lamp-Ignition) • Stator Activated • LRC 5-Seconds • OE Compliant Soft
Start • Lamp-Choke, Field Short Circuit Protection

Page 496
TRANSPO TESTER INSTRUCTIONS
for VALEO MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M524 B 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ

• F-L terminals
• Lamp Activated
• With FR Resistor

Page 497
TRANSPO TESTER INSTRUCTIONS
for VALEO MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M526 B 12 14.8

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
After applying power part requires about 10 seconds to start regulating.Must install a 1.5uF capacitor between
Stator terminal #2 and B-. Attach VRC2010 Stator lead to Stator terminal #1.
Disconnect Sense lead and light turns ON.Push Choke button, choke light will turn ON.
Reconnect Sense lead and push Over Voltage button, light should turn ON, set point is approximately 17.3 volts.

Page 498
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M527 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.
1. disconnect Stator, the Lamp Indicator comes on, and the Field Circuit led should be dim.
2. Reconnect Stator, push the Choke Drive button on the panel, the Choke Drive Indicator comes on.

Stator Activated.
Soft Start & LRC function
Active Lamp -- With Output

Page 499
TRANSPO TESTER INSTRUCTIONS
for VALEO MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M528 B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ

Stator Activated • OE Compliant Soft Start • Under Voltage Lamp • Field, Lamp, Choke - Short Circuit
Protection

Page 500
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M531 B 12 14.45

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.
1. Disconnect Stator, the Lamp Indicator should be on.

Soft Start Function


5 seconds LRC
Under Voltage Lamp
Stator Activated.

Page 501
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M534 B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.
1. Disconnect Sense, the set point should be 14.3V, the Lamp Indication should be on.
2. Reconnect Sense, Disconnect Stator, the Lamp Indication should be on.

Stator Activated
Soft Start Function
6s LRC
Under Voltage Lamp

Page 502
TRANSPO TESTER INSTRUCTIONS
for VALEO MOTOROLA type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M536 B 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ

Page 503
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M540 B 12 13.8

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Use VRC2010 tester to complete RC voltage setpoint testing,Connect RC terminal to VRC2010 tester.
1. Adjust Comm Voltage switch to position 13, Setpoint is 11.8V.
2. Adjust Comm Voltage switch to position 14, Setpoint is 13.3V.
3. Adjust Comm Voltage switch to position 15, Setpoint is 14.4V.
4. Connect the disconnected terminal of Lamp cable to the Light on the VRC2010, disconnect stator, the Lamp Indication
should be on.

RC or Stator Activated.
Soft Start Function
VSet controlled by vehicle RVC system

Page 504
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M544 B 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.
1. Disconnect stator, the Lamp Indication comes on.

Stator Activated.
Soft Start Function
Under Voltage Lamp.

Page 505
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M546 B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.
1. Disconnect Stator, the Lamp Indication comes on.
2. Reconnect Stator, push the Choke Drive button on the panel, the Choke Drive Indication comes on.

Stator or Light Activated.


Soft Start Function
9 seconds LRC
Under Voltage Lamp
Active Lamp -- With Output

Page 506
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M549 B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.
1. Disconnect Stator, the Lamp Indication comes on.
2. Reconnect Stator, push the Choke Drive button on the panel, the Choke Drive Indication comes on.

Stator or Light Activated.


Soft Start Function
9 seconds LRC
Under Voltage Lamp
Active Lamp -- With Output

Page 507
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M550 B 12 14.45

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.
1. Disconnect Stator, the Lamp Indicator comes on.

Stator or Light Activated.


Soft Start function.
4 seconds LRC
Under Voltage Lamp
Standard Lamp -- Without Output

Page 508
TRANSPO TESTER INSTRUCTIONS
for type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M552 B 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

B circuit, high side drive


with softstart
with LRC
with FR

Page 509
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M556 B 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
disconnect the SENSE,the setpiont is about 15.0V.

B circuit,high side drive


light/stator activated
with LRC
with C function
with soft start

Page 510
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M557 B 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
disconnect the stator, lamp is on

B circuit, high side drive


with soft start
with under voltage

Page 511
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M558 B 12 14.65

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.
1. Disconnect Stator, the Lamp Indication should be on.

•B-Circuit, High side drive regulator


•Stator or Lamp Activated
•Soft Start
•3 seconds LRC
•Under Voltage Lamp

Page 512
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M564 B 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.
1. Disconnect Stator, the Lamp Indication comes on.
2. Reconnect Stator, Push “Choke Drive” on the panel, the Choke Drive Indication comes on.

Stator or Light Activated


Soft Start Function
5 seconds LRC
Under Voltage Lamp
Active Lamp -- With Output

Page 513
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M564 B 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect STA1 and STA2 to VRC2010. Turn the STATOR swicth to 150HZ.
1. Disconnect Stator, the Lamp Indication comes on.
2. Reconnect Stator, Push “Choke Drive” on the panel, the Choke Drive Indication comes on.

Stator or Light Activated


Soft Start Function
5 seconds LRC
Under Voltage Lamp
Active Lamp -- With Output

Page 514
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M6120 A 12 14.65

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

TRIO excited.

Page 515
TRANSPO TESTER INSTRUCTIONS
for VALEO type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

M6132 A 12 14.65

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

TRIO excited

Page 516
TRANSPO TESTER INSTRUCTIONS
for MAGNETON-PAL type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

MP293 A 14 28.4

MP291 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 517
TRANSPO TESTER INSTRUCTIONS
for MAGNETON-PAL type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

MP417 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 518
TRANSPO TESTER INSTRUCTIONS
for MAGNETON-PAL type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

MP419 B 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 519
TRANSPO TESTER INSTRUCTIONS
for NIEHOFF type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

N9013 A 12 14.3

N9015 A 24 27.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from blue wire of the regulator. Field lamp should turn off and the meter will indicate low
voltage.

Page 520
TRANSPO TESTER INSTRUCTIONS
for NIEHOFF type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

N9014 A 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from blue wire of the regulator. Field lamp should turn off and the meter will indicate low
voltage and indicator light will turn on.

Page 521
TRANSPO TESTER INSTRUCTIONS
for NIEHOFF type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

NA2-101 A 24 27.5

NA2-102 A 12 14.2

NA2-103 A 32 37.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 522
TRANSPO TESTER INSTRUCTIONS
for NIEHOFF type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

NA2-111 A 24 28.0

NA2-110 A 12 14.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from the terminal marked "IGNITION". Field lamp should turn off and the meter will indicate
approximately 12V. For NA2-111. For NA2-110.

Page 523
TRANSPO TESTER INSTRUCTIONS
for PRESTOLITE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

P8-328 B 12 14.2 P8-407 B 12 15.0

P8-328A B 12 14.2 P8-407A B 12 15.0

P8-379 B 12 15.0 P8-406 B 12 15.0

P8-379A B 12 15.0 P8-406A B 12 15.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 524
TRANSPO TESTER INSTRUCTIONS
for PRESTOLITE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

P8-354 B 12 14.2 P8-357 B 12 14.2

P8-354A B 12 14.2 P8-357A B 12 14.2

P8-355 B 12 14.2 P8-352 B 12 14.2

P8-355A B 12 14.2 P8-352A B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 525
TRANSPO TESTER INSTRUCTIONS
for PRESTOLITE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

P8-368 B 12 15.0 P8-393 B 24 27.5

P8-368A B 12 15.0 P8-393A B 24 27.5

P8-405 B 12 14.2

P8-405A B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 526
TRANSPO TESTER INSTRUCTIONS
for PRESTOLITE type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

P8-403 B 12 14.2 P8-410 B 12 14.2

P8-403A B 12 14.2 P8-410A B 12 14.2

P8-404 B 12 14.2 P8-343 B 12 15.0

P8-404A B 12 14.2 P8-343A B 12 15.0

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 527
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI100 A 12 14.6

TRI110 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 528
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI10DN B 12 14.2

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from regulator's connection marked "STA". Field lamp should turn off and the meter will
indicate 12V.

Page 529
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI219 A 12 14.5 TRI224 A 12 14.5

TRI220 A 12 14.5 TRI225 A 12 14.5

TRI221 A 12 14.5 TRI226 A 12 14.5

TRI222 A 12 14.5 TRI227 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on
between 16.0V and 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.

NOTE: Regulators shown with circuit up (Epoxy side)


NOTE: After repair circuit installation, refer to complete regulator assembly procedure.

REFER TO PRODUCT GROUP TRI-07, PAGE 378-A, FOR REGULATOR'S DIAGRAM

Page 530
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI232 A 12 14.3

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 531
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI233 A 24 27.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 532
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI247 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white test lead from wire marked "STA". Indicator light should turn on, field lamp will remain on and the
meter will indicate 12V. Remove red test lead from wire marked "IG". Field lamp should turn off.
Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on
between 16.0V and 17.1V.

Page 533
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI248 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 534
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI250 A 12 14.5 TRI254 A 12 14.5

TRI251 A 12 14.5 TRI255 A 12 14.5

TRI252 A 12 14.5

TRI253 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on
between 16.0V and 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.

NOTE: Regulators shown with circuit up (Epoxy side)


NOTE: After repair circuit installation, refer to complete regulator assembly procedure.

REFER TO PRODUCT GROUP TRI-07, PAGE 378-A, FOR REGULATOR'S DIAGRAM

Page 535
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI257 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove white lead from terminal marked "stator". The indicator light will turn on and the meter will indicate
approximately 12 volts and the field lamp will remain fully on.
Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on
between 16.0V and 17.1V. Push the choke drive and the "Choke Drive Indicator Lamp" will turn on, if present.

Page 536
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI267 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from the wire marked as "C" and connect a black test lead to the "C" terminal. Field lamp
should still blink and the meter will indicate approximately 12.5v.

Page 537
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI268 A 12 14.5

TRI270 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
TESTER CONNECTION CHART NOTE: This instruction does not apply to TRI270
B ... RED TEST RED (B+) I ... GREEN TEST LEAD (I.L.) T ... RED TEST LEAD (TRIO)
E ... BLACK TEST LEAD (B-) F ... YELLOW TEST LEAD (FLD) A ... RED TEST LEAD (SENSE)
Remove the red test lead from the wire marked "sense". The field light will still blink, the meter will indicate from
15v to 16v and the indicator lamp will remain on.

NOTE: Instruction #3 Does not apply to TRI270

Page 538
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI271 A 12 14.5

TRI276 A 12 14.4

TRI836 A 12 14.4

TRI837 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove the red test lead from the wire marked as "SENSE". The field light will still blink the meter will indicate
from 15V. to 16V, and the indicator lamp will remain on.
Using VRC2010: To check for over Voltage, push the "Over Voltage" switch and the "Lamp Indicator" will turn on
between 16.0V and 17.1V.

Page 539
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI275 A 12 14.5

TRI285 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:

Page 540
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI278 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from the wire marked as "S". Field lamp should still blink and the meter will indicate
approximately 15.5V.

Page 541
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI341 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the set point should be 15.5+/-0.2v.
2. Reconnect Sense, remove Stator, the Lamp comes on and the voltage goes to 12.0V.
3. Reconnect Stator and push the ‘Over Voltage’ button on the panel, the Lamp comes on.

*Connect Black Test Lead to terminal marked “C”, voltage will drop to approximately 12.5v.

Page 542
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI400R A 12 14.5 TRI410 A 12 14.6

TRI400S A 12 14.5 TRI420 A 12 14.6

TRI405 A 12 14.4 TRI421 A 12 14.6

TRI406 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
TESTER CONNECTION CHART B ... RED TEST RED (B+) S ... RED TEST LEAD (SENSE)
R ... RED TEST LEAD (IG) T ... RES TEST LEAD (TRIO) F ... YELLOW TEST LEAD (FLD)
L ... RED TEST LEAD (INDICATOR LIGHT) E ... BLACK TEST LEAD (GROUND)

NOTE: Regulators shown with circuit up (Epoxy side)


NOTE: After repair circuit installation, refer to complete regulator assembly procedure.

REFER TO PRODUCT GROUP TRI-04, PAGE 376-A, FOR REGULATOR'S DIAGRAM

Page 543
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI422 A 12 14.6

TRI430 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
TESTER CONNECTION CHART B ... RED TEST RED (B+) S ... RED TEST LEAD (SENSE)
R ... RED TEST LEAD (IG) T ... RED TEST LEAD (TRIO) F ... YELLOW TEST LEAD (FLD)
L ... RED TEST LEAD (INDICATOR LIGHT) E ... BLACK TEST LEAD (GROUND)

NOTE: Regulators shown with circuit up (Epoxy side)


NOTE: After repair circuit installation, refer to complete regulator assembly procedure.

REFER TO PRODUCT GROUP TRI-04, PAGE 376-A, FOR REGULATOR'S DIAGRAM

Page 544
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI423 A 12 14.6

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Remove red test lead from terminal marked "TRIO". Field lamp should still blink and the meter will indicate
approximately 15.5v.

Page 545
TRANSPO TESTER INSTRUCTIONS
for type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI738 A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the setpoint should be 15.3+/-0.2V.
2. Reconnect Sense, disconnect Stator, the Lamp Indication should be on.
3. Reconnect Stator, push the Over Voltage button on the panel, the Lamp Indication should be on.

Soft Start Function


3 seconds LRC
Over Voltage, Under Voltage Lamp.

Page 546
TRANSPO TESTER INSTRUCTIONS
for HITACHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI744 A 12 14,4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Sense, the set point should be 15.3+/-0.2v.
2. Reconnect Sense, remove Stator, the Lamp comes on and the voltage goes to 12.0V.
3. Reconnect Stator and push the ‘Over Voltage’ button on the panel, the Lamp comes on.

Stator Activated

Page 547
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI839 A 12 14.4

TRI273 A 12 14.4

TRI835 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Remove red test lead from terminal marked "TRIO". Field lamp should still blink, the meter will indicate the set
point voltage and the indicator light will turn on.
2. Reconnect red test to "TRIO". Connector a black test lead to terminal marked "C". Field lamp should still blink
and the meter will indicate approximately 12.5v.

Page 548
TRANSPO TESTER INSTRUCTIONS
for TE REPAIR CIRCUIT type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI845 A 12 14.4

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
Connect Computer (C) to Black (B-), voltage will read 12.5 volts
Remove Sense (Red), Lamp light will turn on.

* Connect only for Computer (C) function test

Page 549
TRANSPO TESTER INSTRUCTIONS
for MITSUBISHI type regulators

PART NO. FLD VOLT SET POINT PART NO. FLD VOLT SET POINT

TRI851HD A 12 14.5

1. POWER OFF: Set ‘FLD’ switch and ‘Voltage Range’ switch to compatible setting. Connect the Voltage Regulator
as indicated in the diagram or as described in the ‘Amendments or Additional Test’ notes.
2. POWER ON: Tester field lamp should blink and tester meter should indicate the approximiate Set Point
Voltage noted in the table above.
3. Amendments or Additional Tests:
1. Disconnect Stator, the Lamp Indicator comes on and the Field Circuit LED should be dim.
2. Reconnect Stator, and connect the C terminal to B-, the set point should be 12.6+/-0.2V.
3. Disconnect C terminal, push the Over Voltage button on the panel, the Lamp Indicator comes on.

• Lamp Activated
• With soft start and LRC
• Over Voltage Lamp function

Page 550
WAI Global Corporate Headquarters
411 Eagleview Blvd., Suite 100, Exton, PA 19341
Toll Free ...... 1-800-877-3340 Email ...... [email protected]
Local ........... 1-610-495-2200 Fax .............. 1-800-948-6121

WAI Europe b.v.


Klappolder 225, 2665 MR Bleiswijk, The Netherlands
Local ........... +31 (0) 10 524 1980 Fax ........... +31 (0) 10 524 1981
Email ...... [email protected]

www.waiglobal.com

You might also like