Motors: Single and Multiple Vane Pumps & Vane Motors
Motors: Single and Multiple Vane Pumps & Vane Motors
Motors: Single and Multiple Vane Pumps & Vane Motors
Introduction
General Information BH* & V*
General Information DT6*
5
Special Pumps 2
Pumps with tank, flow regulating & pressure limiting valves.
Compact Power Pack & Pump
87
2
Motors
MD4C & MHP Motors
97
2
Instructions for Use and Repairs (V* Series)
Cartridge identification, change of rotation, guidelines for repairs
105
2
Instructions for Use and Repairs (DT61Series)
Cartridge identification, change of rotation, guidelines for repairs
115
2
1
2
HYDRAULIC VANE PUMPS
Versión Corel 1.0: 01-06-06
3
4
SINGLE AND MULTIPLE VANE PUMPS
TDZ vane pumps are manufactured in a wide range of displacements, from 2 cc/r to 269 cc/rev.
for single pumps, 460 cc/rev. for double pumps and 560 cc/rev. for triple pumps. 2
INTRODUCTION
All TDZ pumps have a low power to weight ratio, high efficiency, low noise levels, optional inlet
and outlet port positions and ease of maintenance.
Ease of maintenance is achieved by the pump design, where the working components are
contained within a cartridge which can quickly and easily be replaced without disconnecting the
pump from the prime mover or moving it away from the pipe work. TDZ vane pumps are
hydraulically balanced, reducing wear and eliminating bearing loads from within the pump.
The option to rotate the outlet port 90 degrees in relation to the inlet port provides flexibility and
easy installation.
Depending on the application, there are three versions of the larger single, double and triple vane
pumps: low noise industrial models VS and BHS, mobile models VQ and BHQ and multi-
purpose models DT6 (275 bar).
Models VS, VQ and DT6 have UNC threads for the port flanges whilst models BHS, BHQ have
metric threads. On single pumps the outlet port is at the shaft end for models VS, VQ, DT6 on
models BHS and BHQ the outlet port is at the cover end.
5
SINGLE AND MULTIPLE VANE PUMPS
PUMP DRIVE
Direct coaxial drive is recommended via flexible coupling. For indirect drives imposing a radial load on the shaft,
consult TDZ HYDRAULICS S.A. or your nearest distributor for advice.
ROTATION
The direction of rotation can be reversed by turning the ring, rotor and vanes through 180 degrees.
Direction of rotation is viewed from the shaft end.
STARTING
TDZ vane pumps are self priming, however, if possible, fill the pump with oil before starting or bleed the outlet port
while the pump is running to remove any trapped air.
FILTRATION
For satisfactory service life, full flow filtration to provide fluid cleanliness conforming to ISO code 18/15 or better is
recommended.
HYDRAULIC FLUIDS
Use antiwear industrial hydraulic oils with a viscosity of 25-49 cST. Automotive crankcase oils SAE10-SAE20 may
also be used depending on the operating temperature.
The optimum operating temperature is 50 °C with a maximum of 70 °C. At higher temperatures service life is
decreased with degradation of the wearing parts and seals.
For fire resistance fluids, the "F3" version with special seals must be used at reduced pressures and speeds as
indicated below.
With synthetic fluids, water glycols and water in oil emulsions, the maximum recommended speed is 1200 rpm. A
special version of the BHP2 pump is available for speeds up to 5000 rpm
Speeds shown are given as a guide only based on the correct fluid and correct suction characteristics as
recommended by our Technical Services department.
Long or restricted suction lines can cause cavitation, therefore the maximum running speed must be reduced.
Avoid using 90 degree elbows in suction lines, use swept bends where possible. Too viscous fluids will also cause
cavitation.
When using lower displacement pumps within a given pump frame size, speeds slightly higher than those shown in
the charts are acceptable.
For antiwear hydraulic fluids and water glycols, the inlet pressure must not exceed 0.2 bar vacuum, for synthetic
fluids and water in oil emulsions, the inlet pressure must not exceed 0.1 bar vacuum.
This data is for V*20, V*25,V* 35,V* 45, BH*4,BH* 6, BH*7, double and triple pumps. For other pumps see chart.
The intermittent pressures shown in the table can be maintained for 10% of the time, with a maximum duration of 6
seconds/minute.
6
SINGLE AND MULTIPLE VANE PUMPS
INTRODUCTION
Water-Glycol emulsions: 160 Bar
Water-in-oil emulsions: 70 Bar
SOUND LEVEL
Single Pumps: : 2
VS25 and BHS4: 62 dB (A)
VS35 and BHS6: 65 dB (A)
VS45 and BHS7: 71 dB (A)
Double Pumps:
VS43: 68 dB (A)
VS63: 69 dB (A)
VS73: 71 dB (A)
VS64: 69 dB (A)
VS74: 71 dB (A)
VS76: 72 dB (A)
Sound levels measured with hydraulic oil at 140 Bar, 1500 rpm and a vacuum at pump inlet of 0,17 Bar.
However, in the case of double pumps and thru drive pumps, if both cartridges/pumps work simultaneously under pressure,
the sum of the torques absorbed for each of them may exceed the resistance of the shaft.
In practice, the absorbed torque for each cartridge/pump may be calculated with the formula:
In order to choose the most appropriate type of shaft, calculate said torque sum under the most unfavourable working
conditions and compare them with the torque values admitted for each shaft as indicated in table 1.
Analogically, in the thru drive pumps, the absorbed torque for the second pump will be calculated under the most
unfavourable conditions, and it must be checked that it does not exceed the torque values admissible as indicated in table
2 for each connection.
Table 1 Table 2
V*73
V*74
1 588
V*76
11 803
V*7T
86 803
7
SINGLE AND MULTIPLE VANE PUMPS
DT series vane pumps are fixed displacement and high efficiency pumps. Designed under SAE J744c 2 bolt standards,
2 triple pumps), the complete range includes single, double and triple units with wide possibilities of flow
(excluding T6EDC
combinations, porting configurations, possibilities of use of fluids other than petroleum-based oil and a vast number of different
shafts.
The DT series is a hydraulically-balanced design. Quality and composition of materials have been checked and tested over millions
of cycles on our experimental test benches. This fact, together with a rigid bearing and a high resistance to particle contamination
thanks to the double lip vane, makes DT series pumps long -life hydraulic units.
Within 3 different cartridge kit sizes, flows available range from 3 to 31 GPM in C size, 14 to 61 GPM in D size and 42 to 85 GPM in D
size. As in our earlier BH* and V* vane pump series, cartridge kit design allows easy service when replacement or conversion is
needed, reducing the operation to just a few minutes. Cartridge kit design also offer possibilities of quick change of rotation by
changing the position of cam ring .
Four different combinations of porting positions are possible in single pumps. In double pumps 32 combinations are possible and
128 for triple pumps.
The high pressure capability of 275 bar in the DT6 series reduces installation costs and provides long life at reduced pressure.
The high mechanical and volumetric efficiency reduces heat generation and energy consumption. Lower noise levels than most
of hydraulic pump designs suppose an advantage and safety for machine operators.
TDZ Hydraulics DT series vane pumps are unidirectional but they have been designed for an easy change of rotation.
Instructions for change of rotation are included in this catalogue (Instructions for Use and Repair).
RECOMMENDED FLUIDS
Operating characteristics showed in this catalogue have been calculated considering the use of Antiwear petroleum base fluids.
Non Antiwear Petroleum Base Fluids, Synthetic Fluids, Water In Oil Emulsions or Water Glycols are also acceptable. In these cases,
speed and pressure limits will be supplied directly by TDZ Hydraulics or your nearest distributor.
VISCOSITY
Fluid must be clean during the entire working life of the pump in order to maintain a contamination level of ISO 18/14 or even better, if
possible.
Filters with 25 microns are adequate but will not guarantee total cleanliness levels. Suction strainers should be of an adequate size to
provide the recommended inlet pressure. For cold starts or fire-resistant fluids, oversize strainers must be used or omitted.
Higher levels of water than 0.10% in mineral oils or 0.05% in synthetic or biodegradable fluids are not acceptable. In these
cases, water should be drained off the circuit.
FLUID TEMPERATURES
Fluid viscosity should be selected depending on the normal operating temperature of the unit. Cold starts pump should operate at
low pressure and, if possible, low speeds until the fluid warms up to a convenient viscosity for full power application.
Higher flows of C and D sizes also involves speed limitations, as indicated in the technical chart of this catalogue. Fluids other than
Antiwear Petroleum Base fluids will also involve a speed limit, depending on the choice, (consult TDZ or your nearest distributor).
8
SINGLE AND MULTIPLE VANE PUMPS
PRESSURE RATINGS
Maximum pressure in DT6 vane pumps is 275 bar intermittent for C series and 240 bar for D and E series. Nevertheless,
exceptions are indicated in this catalogue when fluids other than Antiwear Petroleum Base are used or in the case of use of
INTRODUCTION
high flows of C and D pump sizes.
Both continuous and intermittent pressures are indicated in this catalogue. The maximum period of intermittent pressure may
be considered acceptable when the average pressure time is less than or equal to the continuous recommended pressure, for
that particular model during a complete cycle of work.
Minimum allowable inlet pressure is 0.95 bar for 1,800 rpm or less, 1.10 bar between 1,800 and 2,300 rpm and 1.30 bar
when the speed is more than 2,300 rpm.
Multiply the above-mentioned values by 1.40 when fluids other than Antiwear Petroleum base fluids are used.
The difference between inlet pressure and atmospheric pressure should not exceed 0.2 bar to prevent aeration. Inlet
Pressure is considered with petroleum base fluids at viscosities of between 10 and 65 cSt.
9
2
10
SINGLE VANE PUMPS
2 11
BH* SINGLE VANE PUMPS
F3 BHQ 4 67 D 1 A 00
1 2 3 4 5 6 7 8
1 - "F3" means special seals for fire-resistant fluids. Omit if not required.
2 - Pump Type:
BHP = 10 vane pump, industrial and mobile use, BSP, NPT & SAE threads.
BHS = 12 vane pump, industrial use (very quiet), metric threads.
BHQ = 10 vane pump and bronze plates, mobile use, metric threads.
3 - Pump model: 1, 2 and 3 in BHP types; 4, 6 and 7 in BHS and BHQ types.
4 - Flow: BHP, BHS and BHQ in Litres per minute at 1000 rpm and 7 Bar.
8- Special characteristics
Omit if not required.
Example: 02 : BSP
03 : UNF
04 : NPT
12
BH* SINGLE VANE PUMPS
2
TDZ DESIGN VANE PUMPS
6 2 0,9 1,9
16 5 1,7 4,3
18 6 2,8 5,3
25 8 4,5 6,9
BHP3 27 9 4,8 600 2500 150 175 7,6 (4) (4) 7,1
35 11 4,8 8,8
38 12 5,4 10,2
44 14 6,6 2000 11,9
50 16 7,8 1500 100 125 13,6
26 8 4,5 6,9
40 12 5,7 10,4
45 14 5,7 2500 11,6
BHS4 55 17 5,8 600 1800 175 210 13,8 Ø38 Ø26 14,5
60 19 5,8 (BHS) 14,6
BHQ4 67 21 6 16,8
80 24 6,2 20,3
88* 27* 6,5 1500 125 150 22,4
66 21 8,6 16,8
81 25 9 2400 20,3
BHS6 97 30 10 1800 24,3 Ø60
600 175 210 Ø32 26,3
BHQ6 112 35 11,4 (BHS) 27,4
121 38 11,4 29,3
142 45 13,1 1500 125 150 33,3
138 42 15 32,3
148 47 15,7 36,3
162 50 14,3 2200 37,9
BHS7 155 175 43,2 38,3
180 57 17,9 600 1800 Ø75 Ø38
BHQ7 193 60 18,6 (BHS) 46,1
214 67 22 51,2
240 75 26 57,4
* 27 gallons (88 lts.) cartridge not mounted in BHQ4 vane pump model.
(1) There is a version of this pump with built-in flow regulating and pressure limiter valves, ref. B2V. If a built-in tank with filter is
required, the ref. Is B2VC (1.5 ltrs. tank) or B2VA (1 litre tank).
(2) Delivery flow reduction in Ltrs./min. at 100 Bar. 22 cST of oil viscosity at operating temperature. To calculate the
approximate delivery flow at a given pressure and speed, use the following formula with flow reduction and theoretical flow values
shown in the chart. Flow reduction values are independent of shaft speed.
13
BH* SINGLE VANE PUMPS
Lts at 1000 rpm 2 3 4,5 5,5 6,5 Mín. Máx. Contin. Intermit. Inlet Outlet (Kgs.)
Gal at 1200 rpm 0,6 0,9 1,2 1,7 2 600 2500 175 210 Ø38 Ø26 14,5
Conicalness 1:8
Inlet Outlet
Frame
REF. GO 01007
14
BH* SINGLE VANE PUMPS
15
BH* SINGLE VANE PUMPS
97
61 20
2,2 Kp.m.
53
Ø10,2
40
5 93
112
11
See chart (Inlet)
See chart (Outlet)
Num. Inlet Outlet
02 3/4" BSP 1/2" BSP
80 ø50 f7
Nº3 Shaft
Nº1 Shaft Nº2 Shaft
16
BH* SINGLE VANE PUMPS
40 10,6
35 9,2
30 15 7,9
15
25 6,6
12
12
20
10
5,3
10
15 8 8 3,9
7 7
10 5 5
2,6
5 1,3
HP Kw
16 12,0
14 15
10,5
12 9,0
12
10 7,5
10
15
8 6,0
8
12
7
6 10
4,5
5 8
7
4 3,0
5
2 1,5
17
BH* SINGLE VANE PUMPS
* For further details see general chart See chart below for
additional connections
DIMENSIONS IN MILLIMETRES 1" = 25.4 millimetres
18
BH* SINGLE VANE PUMPS
2
FLOW AND INPUT POWER DIAGRAMS
120 31,7
105 27,7
90 23,8
43
43
75 37 19,8
37 34
34
60 15,9
28
28
24
45 24 11,9
19
19
30 7,9
15 3,9
HP Kw
40 29,8
43
35 26,1
37
34
30 22,4
25 28 43
18,6
24 37
20 34 14,9
19
28
15 11,2
24
19
10 7,4
5 3,7
19
BH* SINGLE VANE PUMPS
Nº2 Shaft
Nº1 Shaft
Tooth number:13
20
BH* SINGLE VANE PUMPS
2
FLOW AND INPUT POWER DIAGRAMS
160 42,3
140 37,0
120 66 66
31,7
60 60
100 54 54 26,4
80 44 44 21,1
39
39
60 15,9
40 10,6
20 5,3
HP Kw
80 59,7
66
70 52,2
60
54
60 44,7
44
50 37,3
39
40 66 29,8
60
54
30 22,4
44
39
20 14,9
10 7,5
21
BH* SINGLE VANE PUMPS
Tooth number:14
22
BH* SINGLE VANE PUMPS
2
FLOW AND INPUT POWER DIAGRAMS
320 84,5
280 74,0
240 63,4
118 118
112
200 112
52,8
94 94
160 42,3
78 78
120 66 66 31,7
80 21,1
40 10,6
HP Kw
160 119,3
140 104,4
120 89,5
118
112
100 74,6
94
80 59,6
78
118
66 112
60 94
44,7
78
40 66 29,8
20 14,9
23
BH* SINGLE VANE PUMPS
Tooth number:14
24
BH* SINGLE VANE PUMPS
2
FLOW AND INPUT POWER DIAGRAMS
560 147,9
490 129,4
420 111,0
350 195
195
92,5
180
180
210 55,5
140 37,0
70 18,5
HP Kw
200 149,1
150 111,8
160
148
125 135
93,2
100 195
74,6
180
160
75 148 55,9
135
50 37,3
25 18,6
25
V* SINGLE VANE PUMPS
F3 VS 25 67 D 1 A 00
1 2 3 4 5 6 7 8
1 - "F3" means special seals for fire-resistant fluids. Omit if not required.
2 - Pump Type:
4 - Flow: VC, VS and VQ in US Gallons per minute at 1200 rpm and 7 Bar.
8- Special characteristic
Omit if not required
Example: 02 : BSP
03 : UNF
04 : NPT
26
V* SINGLE VANE PUMPS
8 2 0,9 1,9
18 5 2,1 4
VK20 27 8 2,8 6,6
29 9 3,5 600 1800 175 210 6,9 Ø1½" Ø3/4" 12
VQ20 36 11 4,3 7,3
39 12 4,3 7,4
46 14 5,3 210 7,6
26 8 4,5 6,9
40 12 5,7 10,4
2500
45 14 5,7 11,6
1800 175 210 Ø1½" Ø1" 15
VS25 55 17 5,8 600
(VS)
13,8
60 19 5,8 14,6
VQ25 67 21 6 16,8
80 24 6,2 1500 125 150 20,3
88* 27 6,5 21,1
66 21 8,6 16,8
81 25 9 2400 20,3
VS35 97 30 10 600 1800 175 210 24,3 Ø2" Ø1¼" 23
112 35 11,4 (VS) 27,4
VQ35 121 11,4
38 29,3
142 45 13,1 1500 125 150 33,3
138 42 15 32,3
148 47 15,7 36,3
VS45 162 50 14,3 2200 37,9
180 57 17,9 600 1800 155 175 43,2 Ø3" Ø1½" 35,5
VQ45 193 60 18,6 (VS) 46,1
214 67 22 51,2
240 75 26 57,4
(2) Delivery flow reduction in Ltrs./min. at 100 Bar. 22 cST of oil viscosity at operating temperature. To calculate the approximate
delivery flow at a given pressure and speed, use the following formula with flow reduction and theoretical flow values shown in the chart.
Flow reduction values are independent of shaft speed.
Approx. output flow (Ltrs./min.) = Theoretical flow x R.P.M - Reduction x Pressure (Bar)
1000 1000
(3) Nominal power in H.P. at 100 Bar and 1000 RPM (to convert into Kw multiply by 0.735).
To obtain the real input power at different pressure and revolutions, use the formula as follows:
27
V* SINGLE VANE PUMPS
Dimension
Gallons
28
V* SINGLE VANE PUMPS
38 10
Max. pressure (180 bar) 3 gal (7 bar)
34 9
3 gal (180 bar)
Dimension
Galon
Nº1 Shaft
30
V* SINGLE VANE PUMPS
98 26 98 26
9 gal (7 bar)
76 20 76 20
8 gal (7 bar)
9 gal (180 bar)
68 18 68 18
7 gal (7 bar) 8 gal (180 bar)
6 gal (7 bar)
61 16 61 16
45 12 45 12
38 10 38 10
30 8 30 8
23 6 23 6
15 4 15 4
8 2 8 2
0 0 0 0
400 800 1200 1600 2000 2400 2800 R.P.M. 400 800 1200 1600 2000 2400 2800 3200 R.P.M.
31
V* SINGLE VANE PUMPS
32
V* SINGLE VANE PUMPS
90 23,78 90 23,78
14 gal (7 bar)
80 21,13 80 21,13
14 gal (210 bar)
12 gal (7 bar)
70 18,49 70 18,49
12 gal (210 bar) 11 gal (7 bar)
60 15,85 60 15,85
8 gal (7 bar) 11 gal (210 bar)
9 gal (7 bar)
50 13,21 50 13,21
8 gal (210 bar) 9 gal (210 bar)
40 10,58 40 10,58
5 gal (7 bar)
30 7,93 30 7,93
5 gal (210 bar)
20 5,28 20 5,28
2 gal (7 bar)
10 2,64 10 2,64
2 gal (210 bar)
400 800 1200 1500 2000 R.P.M. 400 800 1200 1500 2000 R.P.M.
CV Kw
32,18 24
37,55 28
21,46 16 11 gal (210 bar)
32,18 24
5 gal (210 bar)
16,09 12
14 gal (210 bar)
26,28 20
10,73 8 8 gal (210 bar)
21,46 16
5,36 4
9 gal (7 bar)
12 gal (7 bar) 16,09 12
5 gal (7 bar)
0
10 7,5 10,73 8
5 3,75 5,36 4
14 gal (7 bar)
2 gal (7 bar) 11 gal (7 bar)
8 gal (7 bar)
400 800 1200 1500 2000 R.P.M. 400 800 1200 1500 2000 R.P.M.
33
V* SINGLE VANE PUMPS
Outlet
Inlet
34
V* SINGLE VANE PUMPS
160 42,3
140 37,0
120 21 21
31,7
19 19
100 17 17 26,4
80 14 14 21,1
12
12
60 15,9
40 10,6
20 5,3
HP Kw
80 59,7
21
70 52,2
19
17
60 44,7
14
50 37,3
12
40 21 29,8
19
17
30 22,4
14
12
20 14,9
10 7,5
35
V* SINGLE VANE PUMPS
Lts.at 1000 rpm 66 81 97 112 121 142* Min. Max. Contin. Intermit. Inlet Outlet (Kgs.)
Gal.at 1200 rpm 21 25 30 35 38 45* 600 2400* 175 210* Ø2" Ø1"1/4 23
Outlet
Inlet
36
V* SINGLE VANE PUMPS
320 84,5
280 74,0
240 63,4
38
38
35
35
200 52,8
30 30
160 42,3
25 25
120 21 21 31,7
80 21,1
40 10,6
HP Kw
160 119,3
140 104,4
120 89,5
38
100 35
74,6
30
80 59,6
25
38
21 35
60 30 44,7
25
40 21
29,8
20 14,9
37
V* SINGLE VANE PUMPS
Lts.a 1000 rpm 138 148 162 180 193 214 240 Mín. Máx. Contin. Intermit. Inlet Outlet (Kgs.)
Gal. a 1200 rpm 42 47 50 57 60 67 75 600 2200* 155 175 Ø3" Ø1"1/2 35,5
* For further details see general chart
Tooth number: 14
560 147,9
490 129,4
420 111,0
350 60
60
92,5
57
57
50
280 50
74,0
47 47
42 42
210 55,5
140 37,0
70 18,5
HP Kw
200 149,1
175 60 130,5
57
150 111,8
50
47
125 42
93,2
100 74,6
60
57
50
75 47 55,9
42
50 37,3
25 18,6
39
DT6TSINGLE VANE PUMPS
DT6I- C - * - B - 17 - 1 - R - 00 - B - 1 - M
Special Features
1: NBR
Seal Class
2: VITON
Design letter
Bidirectional
M* 1 shaft seal
P* 2 shaft seals
Size (C, D, E)
40
DT6 SINGLE VANE PUMPS - GENERAL CHARACTERISTICS
SINGLE PUMPS
Pump Cartridge Theoretical Maximum Max. speed Min. speed Weight Front flange SAE 4 holes flange
Model model displacement Pressure rpm rpm Kgs Standard
3
Cm /rev SAE j744c Suction Pressure
ISO 3019-1
003 10.8
005 17.2
006 21.3
008 26.4
010 34.1
012 37.1 275 2800 400 15 SAE B 1 ½” 1”
DT6C 014 46.0
017 58.3
020 63.8
022 70.3
025 79.3
028 88.8 210 2500
031 100
DT6CP Pump model only mount B14 to B31 cartridges
014 47.6
020 66.0
024 79.5
028 89.7
031 98.3 240 2500 400 24 SAE C 2” 1 1/4”
DT6D 035 111.0
038 120.3
042 136.0
045 145.7 2200
050 158.0 210
061 190.5 120 1800
042 132.3
045 142.4
050 158.5
DT6E 052 164.8
062 196.7 240 2200 400 44 SAE C 3” 1 ½”
066 213.3
072 227.1
085 269.8 90 2000
00 01 02 03
P P-S P P
S S
41
DT6C OPERATING CHARACTERISTICS
FLOW
2 SPEED (rpm) PRESSURE (bar) WEIGHT
Mín. Máx. Intermit. Contin. (Kgs.)
Lts/min.at 1000 rpm 11 17 21 26 34 37 46 58 64 70 79 89 100
Gal/min.at 1200 rpm 3 5 6 8 10 12 14 17 20 22 25 28 31 400 2800* 275 240* 15
80 107,2
250 66,13 31
70 93,8
31 28
0 0
0 1000 2000 3000 R.P.M. 0 1000 2000 3000 R.P.M.
To calculate the real flow at a given operating pressure, To calculate the theoretical input power at other
substract the internal leakage value for this pressure pressures and speeds, use the formula:
(see diagram below) from the theoretical flow.
(See diagram above). Q(L/min.) x P(Bar)
P(Kw)
600
Where Q is the theoretical flow (upper left diagram)
and P the operating pressure.
N=2800
24 cSt
N=2500 24 cSt
10 cSt N=1000
24 5
Internal leaking qVs [l/min.]
21
4
Power loss Ps [Kw]
18
15 3
12
9 2
6
1
3
0 0
0 35 70 105 140 160175190 210 240 275 0 35 70 105 140 160 175190 210 240 275
42
DIMENSIONS - SINGLE VANE PUMPS DT6C
45,5
174,5 40,7 7,9
146,0 7,9 24,5
73,0
24,5 1,5 x 45º
1,5 x 45º
161,5 71,4
82,3 38,1
9,7 38,1
Mounting Torque 159Nm
7,9
6,35 Max Key 6,35/6,30
76,2
Ø 101,60/101,55
134,6
Ø 51,3
Ø22,22 / 22,20
M8 x 16,0
24,54 Max
1,5 x 45º
1,3 x 45º
Shaft Code 1
3/8-16 UNC x 19.05 Deep
12,7
35,7 26,2 58,2
1/2-13 UNC x 22.35 Deep 17,85 13,10 7,9
31,8
Key 4,762/4,712
69,86
52,4
26,2
34,93
24,54 Max
Ø22,22 / 22,20
1,5 x 45º
FLOW
2 SPEED (rpm) PRESSURE (bar) WEIGHT
Mín. Máx. Intermit. Contin. (Kgs.)
Lts/min.at 1000 rpm 48 66 80 90 98 111 120 136 146 158 191
Gal/min.at 1200 rpm 14 20 24 28 31 35 38 42 45 50 61 400 2500* 240 210 24
50 13,22 20 26,8
10 13,4
0 0
0 500 1000 1500 2000 2500 R.P.M. 0 500 1000 1500 2000 2500 R.P.M.
To calculate the real flow at a given operating pressure, To calculate the theoretical input power at other
substract the internal leakage value for this pressure pressures and speeds, use the formula:
(see diagram below) from the theoretical flow.
(See diagram above). Q(L/min.) x P(Bar)
P(Kw)
600
Where Q is the theoretical flow (upper left diagram)
and P the operating pressure.
N=2400
24 cSt N=1500 24 cSt
10 cSt N=1000
32 6
Internal leaking qVs [l/min.]
28 5
Power loss Ps [Kw]
24
4
20
16 3
12 2
8
1
4
0 0
0 35 70 105 140 160 175 190 210 240 0 35 70 105 140 160 175 190 210 240
44
DIMENSIONS - SINGLE VANE PUMPS DT6D
55,1
212,4 7,9
181,0 38,1
90,5
2,3 x 45º
Ø17,5
Shaft Code 3
SAE C Splined shaft 1-J498b
12/24 d.p. - 14 Teeth
30º Pressure angle
184,9 83,6
87,4 38,1 12,7
7,9
6,35 Max
Shaft Code 1
49,3
Key 7,94/7,89
77,7
7,9
2,3 x 45º
Ø127,00/126,95
156,7
Ø64,3
Ø31,75/31,70
35,27 Max
2,3 x 45º
1,3 x 45º
Shaft Code 4
7/16-14 UNC x 22.35 No SAE Splined shaft 1-J498b
15,7 73,2 12/24 d.p. - 14 Teeth
4 Orifices1/2-13 UNC x 23.88 42,9 30,2 30º Pressure angle
38,1
Mounting torque 187 Nm
Key 7,94/7,89
77,7
58,7
Ø 31,75/31,70
35,27 Max
2,3 x 45º
FLOW
2 SPEED (rpm) PRESSURE (bar) WEIGHT
Mín. Máx. Intermit. Contin. (Kgs.)
Lts/min.at 1000 rpm 132 142 156 165 197 213 227 270
Gal/min.at 1200 rpm 42 45 50 52 62 66 72 85 400 2200* 240 210 44
0 500 1000 1500 2000 2500 R.P.M. 0 500 1000 1500 2000 2500 R.P.M.
To calculate the real flow at a given operating pressure, To calculate the theoretical input power at other
substract the internal leakage value for this pressure pressures and speeds, use the formula:
(see diagram below) from the theoretical flow.
(See diagram above). Q(L/min.) x P(Bar)
P(Kw)
600
Where Q is the theoretical flow (upper left diagram)
and P the operating pressure.
N=2200
24 cSt N=1500 24 cSt
10 cSt N=1000
36 6
Internal leaking qVs [l/min.]
32
5
Power loss Ps [Kw]
28
24 4
20
3
16
12 2
8
1
4
0 0
0 35 70 105 140 160175 190 210 240 0 35 70 105 140 160 175 190 210 240
46
DIMENSIONS - SINGLE VANE PUMPS DT6E
55,9 62,2
213
181 7,9 7,9
90,5 38,1 31,5
Ø 147,6
2,3 x 45º
2,3 x 45º
Ø17,5
Shaft Code 3 Shaft Code 4
SAE C Splined shaft 1-J498b SAE C-C Splined shaft
12/24 d.p. - 14 Teeth 1-J498b 12/24 d.p. -
30º Pressure angle 17 Teeth
30º Pressure angle
Key 9,52/9,47
98,6
M10 x 20
Ø127,00/126,95
Ø 38,10/38,05
42,36 Max
Ø 76,2
187,5
2,3 x 45º
1,3 x 45º
Shaft Code 1
SAE C-C
61,9
4 Orifices 5/8-11 UNC x 23.88 17,5
61,9 35,7
38,1
Key 7,94/7,89
Ø 31,75/31,70
Ø35,31 Max
69,8
106,4
2,3 x 45º
Shaft Code 2
4 Orifices 1/2-13 UNC x 23.37
47
48
THRU DRIVE SINGLE VANE PUMPS
See single V* pumps for displacement & power diagrams (Pages 35, 37.39)
49
THRU DRIVE SINGLE VANE PUMPS
2
F3 VS 7T C 60 D 86 A A
1 2 3 4 5 6 7 8 9
1 - "F3" means special seals for fire-resistant fluids. Omit if not required
2 - Pump Type:
7 - Shaft type:
1: Parallel keyed
11: Splined
86: Heavy duty parallel keyed
50
THRU DRIVE SINGLE VANE PUMPS
2
FLOW SPEED PRESSURE Nominal CONNECTION WEIGHT
TYPE Gal. At Reduction
(rpm) (Bar) Power (Kgs.)
Lts.at
(1) Delivery flow reduction in Ltrs./min. at 100 Bar. 22 cST of oil viscosity at operating temperature. To calculate the approximate
delivery flow at a given pressure and speed, use the following formula with flow reduction and theoretical flow values shown in
the chart. Flow reduction values are independent of shaft speed.
Approx. outpout flow (Ltrs./min.) = Theoretical flow x R.P.M - Reduction Pressure (bar)
1000 100
(2) Nominal power in H.P. at 100 Bar and 1000 RPM (to convert into Kw multiply by 0.735).
To obtain the real input power at different pressure and revolutions, use the formula as follows:
51
THRU DRIVE SINGLE VANE PUMPS
2
DIMENSIONS IN MILLIMETRES 1" = 25.4 millimetres
A 130
B 315
C 440 (V*6TC)
700 (V*7TC)
52
THRU DRIVE SINGLE VANE PUMPS
2
DIMENSIONS IN MILLIMETRES 1" = 25.4 millimetres
Tooth number: 13
53
THRU DRIVE SINGLE VANE PUMPS
2
DIMENSIONS IN MILLIMETRES 1" = 25.4 millimetres
Model A
V*6TA 20
V*6TB 30
V*6TC 38
54
THRU DRIVE SINGLE VANE PUMPS
2
DIMENSIONS IN MILLIMETRES 1" = 25.4 millimetres
V*7TA 20
V*7TB 30
V*7TC 38
55
56
DOUBLE VANE PUMPS
57
BHP & V* DOUBLE VANE PUMPS
2 F3 VS 43 21 8 D 1 A A
1 2 3 4 5 6 7 8 9
1 - "F3" means special seals for fire-resistant fluids. Omit if not required
2 - Pump Type:
4 - Pump flow at shaft side: BHP33 model in litres per minute at 1000 rpm and 7 Bar.
All the other models in US gallons per minute at 1200 rpm and 7 Bar.
(See flow chart).
5 - Pump flow at cover side: BHP33 and VS42-VQ42 models in litres per minute
at 1000 rpm and 7 Bar. All the other models in gallons per minute at 1200 rpm and 7 Bar.
(See flow chart).
7 - Shaft type:
1: Parallel keyed
2: Splined, (only mounted in BHP 33 model)
11: Splined
86: Heavy duty parallel keyed
58
DOUBLE VANE PUMPS
26 8 4,5 6,9
40 12 5,7 10,4
2500 7 2,2 0,7 1,8
* 27 gallons (88lts.) cartridge not mounted in VQ 42, VQ 43, VQ 64, VQ 74 vane pump model.
(1), (2) & (3) Please turn to next page
59
BHP DOUBLE VANE PUMPS
Outlet
Inlet
Nº2 Shaft
Nº1 Shaft
Diametral pitch: 16/32
Tooth number: 13
60
V* DOUBLE VANE PUMPS
2
DIMENSIONS IN MILLIMETRES 1" = 25.4 millimetres
38 85,5 85
76,3 76,5
64
53
9,5
3/8"x16 UNC
13
Ø25,4 Outlet Ø45 Inlet
1/2"x13 UNC
Ø14,3
146
26,2 42,8 175
1/2"BSP Outlet
Tooth number: 13
There is a version for the pump of the cover end with flow regulating and pressure limiter valves whose reference V*42V
61
V* DOUBLE VANE PUMPS
38 101,5 89,5
76,3 84
64
76,3
9,5 250
10,5
6,5
3/8"x16 UNC
13
Ø25,4 Outlet Ø64 Inlet
1/2"x13 UNC
Ø14,3
3/8"x16 UNC
Ø101,6 52,4 89 Ø121
47,6
146
26,2 50,8 22,2 175
Ø19 Outlet 3/4"BSP
(Optional outlet)
Nº1 Shaft Nº11 Shaft Nº86 Shaft
Tooth number: 13
62
V* DOUBLE VANE PUMPS
2
DIMENSIONS IN MILLIMETRES 1" = 25.4 millimetres
38 110,9 98
82,5 89,5
78
76,3
7/16"x14 UNC
16
Ø31,8 Ø76 Inlet
5/8"x11 UNC
Ø17,5
3/8"x16 UNC
Ø127 58,7 106,3 Ø148
47,6
181
30,2 61,9 22,2
213
Ø19 Outlet
3/4"BSP
(Optional outlet)
Tooth number: 14
63
V* DOUBLE VANE PUMPS
38 116,9 110
82,5 89,5
78
75
7/16"x14 UNC
16
Ø31,8 Outlet Ø76 Inlet
5/8"x11 UNC
Ø17,5
3/8"x16 UNC
Ø127 58,7 106,3 Ø148
52,4
181
30,2 61,9 26,2
213
Ø25,4 Outlet
3/4"BSP
(Optional outlet)
(Opcional)
Tooth number: 14
64
V* DOUBLE VANE PUMPS
2
DIMENSIONS IN MILLIMETRES 1" = 25.4 millimetres
43 120 120
93,7 102,5
85
76,3
1/2"x13 UNC
16
Ø38,1 Outlet Ø89 Inlet
5/8"x11 UNC
Ø17,5
3/8"x16 UNC
Ø127 69,8 120,6 Ø148
47,6
181
35,8 69,8 22,2 213
Ø19 Outlet 3/4"BSP
(Optional outlet)
Tooth number: 14
65
V* DOUBLE VANE PUMPS
43 120 136
93,7 102,5
83
75
12,7 325 35
10,5
1/2"x13 UNC
16
Ø38,1 Outlet Ø89 Inlet
5/8"x11 UNC
Ø17,5
3/8"x16 UNC
Ø127 69,8 120,6 Ø148
52,4
181
35,8 69,8 26,2
Outlet 213
Ø25,4 Outlet 3/4"BSP
(Optional outlet)
Tooth number: 14
66
V* DOUBLE VANE PUMPS
2
DIMENSIONS IN MILLIMETRES 1" = 25.4 millimetres
Inlet
Outlet
Tooth number: 14
67
ORDERING CODE - SERIES DT
DT6*I- CC - * - B -17/14 - 1 - R - 00 - B - 1 - M - 00
Special Features
1: NBR
Seal Class
2: VITON
Design letter
Bidirectional
M* 1 shaft seal
P* 2 shaft seals
Size (CC, DC, EC, ED)
68
DT61DOUBLE VANE PUMPS
GENERAL CHARACTERISTICS
DOUBLE VANE PUMPS
P1 P2 Front SAE 4 Holes
flange flange
Pump Cartridge Theoretical Maxim. Cartridge Theoretical Maxim. Maxim. Minim. Weight
standard
Model Model displacement Pressure Model displacement Pressure speed speed Kgs Suction Pressure
SAE j744c S P1 P2
3
Cm /rev Bar Cm3/rev Bar
ISO 3019-1
DT6CC/M 003 a 031 10.8 a 100 275 003 a 031 10.8 a 100 275 2800 400 SAE B 26 2 ½”ó 3” 1” 1” ó 3/4”
DT6DC/M 014 a 061 47.6 a 190.5 240 003 a 031 10.8 a 100 275 2800 400 SAE C 37 3” 1 1/4” 1”
DT6EC/M 042 a 085 132.3 a 269.8 240 003 a 031 10.8 a 100 275 2200 400 SAE C 55 3 ½” 1 ½” 1”
DT6ED/M 042 a 085 132.3 a 268.8 240 014 a 061 47.6 a 190.5 240 2200 400 SAE C 66 4” 1 ½” 1”
Above mentioned values of maximum speed and maximum pressure are based on use of antiwear oil only.
Please contact TDZ for particular values when different fluids are used, (synthetic fluids, water in oil emulsions,
water glycol, etcetera)
DOUBLE VANE PUMPS - PORTING COMBINATION DT6CC-DT6DC-DT6EC
00 01 02 03 04 05 06 07
P1-P2 P1-P2 S-P1-P2 P1-P2 P1 P1 P1 P1-S
S S P2
S S P2 P2
S S-P2
08 09 10 11 12 13 14 15
P1-S P1-S P1 P1 P1 P1 P1 P1
P2 P2 P2 P2
S S S
P2 S
P2 P2 S P2 S
16 17 18 19 20 21 22 23
P1-S P1 P1 P1 P1 P1
P2 P2 P2 P1 P1
P2
S S S S
P2 P2 P2 P2
S S S
24 25 26 27 28 29 30 31
P1-S P1-S P1-S P1-S P1 P2 P1 P1
P2 P2 P1
P2
S S S S
P2 P2 P2 P2
S S-P2
08 09 10 11 12 13 14 15
P1-S P1-S P1 P1 P1 P1 P1 P1
P2 P2 P2 P2
S S S
P2 S
P2 P2 S P2
S= Suction port | P1= Shaft end pressure port | P2= Cover end pressure port
69
DT61DOUBLE VANE PUMPS
2
SHAFT END SECTION
FLOW
2 SPEED (rpm) PRESSURE (bar) WEIGHT
Mín. Máx. Intermit. Contin. (Kgs.)
Lts/min.at 1000 rpm 11 17 21 26 34 37 46 58 64 70 79 89 100
Gal/min.at 1200 rpm 3 5 6 8 10 12 14 17 20 22 25 28 31 400 2800* 275 240* 15
FLOW
2 SPEED (rpm) PRESSURE (bar) WEIGHT
Mín. Máx. Intermit. Contin. (Kgs.)
Lts/min.at 1000 rpm 11 17 21 26 34 37 46 58 64 70 79 89 100
Gal/min.at 1200 rpm 3 5 6 8 10 12 14 17 20 22 25 28 31 400 2800* 275 240* 15
SHAFT END
See DT6C Single Pumps for flow and input power diagrams (page 42)
COVER END
See DT6C Single Pumps for flow and input power diagrams (page 42)
70
DT61DOUBLE VANE PUMPS
76,2
DT6CC reference depending your option.
Ø 14,3
265,6 71,4
88,2 101,6 38,1
9,7 38,1
7,9
6,35 Max
Key 6,35/6,30
84,1
M8 x 16
Ø 101,60/101,55
D
Ø 51,3
Shaft Code 3
28,22 Max
1,3 x 45º
Mounting Torque 61 Nm
Shaft Code 2 40,7
SAE BB 24,5
E - 4 Orifices 4 Orifices 3/8-16 UNC x 19.05 7,9
12,7
1,5 x 45º
26,2 58,2
B B 13,1 7,9
31,7
Key 4,762/4,712
52,4
Ø 22,225/22,20
A
Ø 24,53 Max
26,2
A
1,5 x 45º
Shaft Code 5
SAE B Splined shaft
1-J498b 16/32 d.p. -
13 Teeth
Ø C - Pressure Ø C - Suction Ø 25,4 - Pressure Shaft Code 1 30º Pressure angle
Keyed no SAE
71
DT61DOUBLE VANE PUMPS
2
SHAFT END SECTION
FLOW
2 SPEED (rpm) PRESSURE (bar) WEIGHT
Mín. Máx. Intermit. Contin. (Kgs.)
Lts/min.at 1000 rpm 48 66 80 90 98 111 120 136 146 158 191
Gal/min.at 1200 rpm 14 20 24 28 31 35 38 42 45 50 61 400 2500* 240 210 24
FLOW
2 SPEED (rpm) PRESSURE (bar) WEIGHT
Mín. Máx. Intermit. Contin. (Kgs.)
Lts/min.at 1000 rpm 11 17 21 26 34 37 46 58 64 70 79 89 100
Gal/min.at 1200 rpm 3 5 6 8 10 12 14 17 20 22 25 28 31 400 2800* 275 240* 15
SHAFT END
See DT6D Single Pumps for flow and input power diagrams (page 44)
COVER END
See DT6C Single Pumps for flow and input power diagrams (page 42)
72
DT61DOUBLE VANE PUMPS
82,6
Ø 17,5
286 83,6
109,5 114,3 38,1 12,7 Shaft Code 1
7,9 SAE C
6,35 Max 49,3
Key 7,95/7,90
M10 x 20
88,9
74,7
Ø 127,00/126,95
Ø 64,5
Ø 31,75/31,70
32,28 Max
73,9
2,3 x 45º
1,3 x 45º
Mounting Torque 68 Nm
58,7
47,8
Ø 31,75/31,70
Ø 35,28 Max
2,3 x 45º
73
DT61DOUBLE VANE PUMPS
2
SHAFT END SECTION
FLOW
2 SPEED (rpm) PRESSURE (bar) WEIGHT
Mín. Máx. Intermit. Contin. (Kgs.)
Lts/min.at 1000 rpm 132 142 156 165 197 213 227 270
Gal/min.at 1200 rpm 42 45 50 52 62 66 72 85 400 2200* 240 210 44
FLOW
2 SPEED (rpm) PRESSURE (bar) WEIGHT
Mín. Máx. Intermit. Contin. (Kgs.)
Lts/min.at 1000 rpm 11 17 21 26 34 37 46 58 64 70 79 89 100
Gal/min.at 1200 rpm 3 5 6 8 10 12 14 17 20 22 25 28 31 400 2800* 275 240* 15
SHAFT END
See DT6E Single Pumps for flow and input power diagrams (page 46)
COVER END
See DT6C Single Pumps for flow and input power diagrams (page 42)
74
DT61DOUBLE VANE PUMPS
90,5 31,4
7,9 2
38,1
2,3 x 45º
2,3 x 45º
331,6 90,9
136,7 118,5 52,3 12,7 Shaft Code 1
7,9 SAE CC
6,35 Max 50,8
Key 9,52/9,47
M10 x 20
98,4
102,4
74,7
Ø 127,00/126,95
Ø 42,36 Max
Ø 38,10/38,05
Ø 76,2
2,3 x 45º
76,2
88,9
1,3 x 45º
Mounting Torque 68 Nm
Key 7,94/7,89
Ø 31,75/31,70
38,1
Ø 35,27 Max
120,6
69,8
52,4
2,3 x 45º
Ø 25,4 - Pressure
Shaft Code 2
75
DT61DOUBLE VANE PUMPS
2
SHAFT END SECTION
FLOW
2 SPEED (rpm) PRESSURE (bar) WEIGHT
Mín. Máx. Intermit. Contin. (Kgs.)
Lts/min.at 1000 rpm 132 142 156 165 197 213 227 270
Gal/min.at 1200 rpm 42 45 50 52 62 66 72 85 400 2200* 240 210 44
FLOW
2 SPEED (rpm) PRESSURE (bar) WEIGHT
Mín. Máx. Intermit. Contin. (Kgs.)
Lts/min.at 1000 rpm 48 66 80 90 98 111 120 136 146 158 191
Gal/min.at 1200 rpm 14 20 24 28 31 35 38 42 45 50 61 400 2500* 240 210 24
SHAFT END
See DT6E Single Pumps for flow and input power diagrams (page 46)
COVER END
See DT6D Single Pumps for flow and input power diagrams (page 44)
76
DT61DOUBLE VANE PUMPS
212,5
61 55,9
2
181 7,9
90,5 7,9
31,4
38,1
2,3 x 45º
2,3 x 45º
Ø 17,5
Shaft Code 4
Key 9,52/9,47
98,4
M10 x 20
102,4
101,6
Ø 127,00/126,95
Ø 42,36 Max
Ø 38,10/38,05
Ø 76,2
2,3 x 45º
81
88,9
1,3 x 45º
Mounting Torque 187 Nm
Key 7,94/7,89
38,1
69,8
130,2
58,7
Ø 31,75/31,70
Ø 35,27 Max
2,3 x 45º
Shaft Code 2
Ø 29,5 - Pressure Cylindrical no SAE
Ø 101,6- Suction Ø 37,1 - Pressure
77
78
DT61TRIPLE VANE PUMPS
79
DT6 TRIPLE VANE PUMPS
2
DT6 TRIPLE VANE PUMPS ORDERING CODE
Special Features
1:NBR
Seal Class
5:VITON
Design letter
R: clockwise
Direction of rotation L: counterclockwise
Bidirectional
80
DT6 TRIPLE VANE PUMPS - GENERAL CHARACTERISTICS
DT6DCC 014 a 061 47.6 a 190.5 240 003 a 031 10.8 a 100 275 003 a 031 10.8 a 100 275 2500 SAE C 61 4” 1 1/4” 1” 1” ó 3/4”
DT6EDC 042 a 085 132.3 a 269.8 240 014 a 061 47.6 a 190.5 240 003 a 031 10.8 a 100 275 2200 ISO 3019-2 100 4” 1 ½” 1 1/4” 1” ó 3/4”
S= Suction port | P1= Shaft end pressure port | P2= Middle pressure port | P3= Cover end pressure port
81
DT6 TRIPLE VANE PUMPS
MIDDLE SECTION
FLOW
2 SPEED (rpm) PRESSURE (bar) WEIGHT
Mín. Máx. Intermit. Contin. (Kgs.)
Lts/min.at 1000 rpm 11 17 21 26 34 37 46 58 64 70 79 89 100
Gal/min.at 1200 rpm 3 5 6 8 10 12 14 17 20 22 25 28 31 400 2800* 275 240* 15
SHAFT END
See DT6D Single Pumps for flow and input power diagrams (page 44)
MIDDLE BODY
See DT6C Single Pumps for flow and input power diagrams (page 42)
COVER END
See DT6C Single Pumps for flow and input power diagrams (page 42)
82
DT6 TRIPLE VANE PUMPS
90,5
181
7,9 7,9
2
31,4 38,1
2,3 x 45º 2,3 x 45º
127
Ø 127,00/126,95
Code 00 Code01
Ø 31,75/31,70
P3 1” 3/4”
Ø 34,6 Max
85
2,3 x 45º
M10 x 20
130,2
58,7
52,4
A
Ø 38,10/38,05
Ø 64,3
2,3 x 45º
Shaft Code 2
Ø C - Pressure Ø 25,4 - Pressure Ø 101,6- Suction Ø 31,8 - Pressure Keyed SAE CC 83
DT6 TRIPLE VANE PUMPS
MIDDLE SECTION
FLOW
2 SPEED (rpm) PRESSURE (bar) WEIGHT
Mín. Máx. Intermit. Contin. (Kgs.)
Lts/min.at 1000 rpm 48 66 80 90 98 111 120 136 146 158 191
Gal/min.at 1200 rpm 14 20 24 28 31 35 38 42 45 50 61 400 2500* 240 210 24
* See page 41 for further information about speed & pressure.
SHAFT END
See DT6E Single Pumps for flow and input power diagrams (page 46)
MIDDLE BODY
See DT6D Single Pumps for flow and input power diagrams (page 44)
COVER END
See DT6C Single Pumps for flow and input power diagrams (page 42)
84
DT6 TRIPLE VANE PUMPS
2
45º
5
31
Alternative ports
Ø
Orifice Code A B C
9,9
139,7
63,5
115
74,7
101,6
Ø 249,98/249,94
Ø 48,9 Max
M12 x 24
M12 x 20
22 8,9 Code 00 Code 01
120,1 100,7
468 91,9
P3 1” SAE 3/4” SAE
M10 x 19 M12 x 24 M16 x 30 M12 x 30
B 30,2 77,8 35,8
Ø 44,99/45,02
Ø 14,00/13,95
69,9
130,2
58,7
209
A
These pumps include in a compact set, one BHP2 vane pump, one
pressure limiter valve and one flow regulating pilot valve; being also
possible to add an oil tank with paper filter cartridge.
So, in a very small place and at an economical cost almost all
necessary elements are available for many simple hydraulic circuits.
Flow regulating valve gives constant delivery flow, even with changes
in pump rotation speed and load.
87
88
SPECIAL VANE PUMPS
CH25/PRODUCT INFORMATION
The CH-25 contributes a definitive solution of the problems that appear in the installation of a
hydraulic system, such as the assembly and the design. It is a set formed by a simple o multiple
vane pump, a veried group of valves to be able to make easily tipical schemes, a built-in high
pressure filter and support to be able to be connected a electric standard B5 motor of diverse
powers, all integrated it in an extremely compact equipment. The reason that it mounts a vane
pump must to the requirements of the industry today, then facility and flexibility of handling and
spare parts, high capacity of flow (to 80 GPM), high work pressure (to 270 bar), very high
efficiency (94%), and all it with a highly quiet operation due to its compact design.
89
SPECIAL VANE PUMPS
CH25/MAIN DIMENSIONS
90
SPECIAL VANE PUMPS
CH25/ASSEMBLY SCHEME
Assembly examples
91
SPECIAL VANE PUMPS
Inlet
Outlet
DIMENSIONS IN MILLIMETRES
1" = 25.4 millimetres
Continuous line shows those of pumps with outlet port sized to give
as maximum the cartridge rated flow.
Broken line is, for instance, of one pump with hole sized to give as
maximum flow 18 Ltrs. (In this case cartridge rated flow is 15 ltrs. at
1000 rpm.)
Litres/minute
Hexagonal 24
Nº1 Shaft
Nº2 Shaft
Diametral pitch: 16/32
Tooth number: 9
Nº3 Shaft
M12x1,5 M16x1,5 7
8
M14x1,5 M18x1,5
10
M16x1,5 3/4" BSP 12 Port sizes are optional.
3/8" BSP 15
Any combination can be supplied.
92
SPECIAL VANE PUMPS
B2VA & B2VC SINGLE VANE PUMP WITH VALVE, TANK AND FILTER
B2VC
(1,5 ltrs)
B2VA
(1 ltr)
Outlet
Nº3 Shaft
Nº1 Shaft Nº2 Shaft
Diametral pitch: 16/32
Tooth number: 9
Continuous line shows those of pumps with outlet port sized to give
as maximum the cartridge rated flow.
Broken line is, for instance, of one pump with hole sized to give as OUTLET INLET CARTRIDGES
maximum flow 18 Ltrs. (In this case cartridge rated flow is 12 ltrs. at Ltrs./min a 1000 rpm
1000 rpm.)
M12x1,5 Ø 13 7
8
M14x1,5
10
Litres/minute
M16x1,5 12
3/8" BSP 15
93
SPECIAL VANE PUMPS
TYPES
2 B2VRC: Pump with manual flow & pressure regulating valves
B2VARC: Pump with f. & p. valves and 1 Ltr. tank
B2VCRC: Pump with f. & p. regulating valves and 1.5 Ltrs. tank
Outlet
Aprox.
It can optionally
be served with
adjustable ring.
94
SPECIAL VANE PUMPS
FR01000 (1.5 LTRS) AND FR05050 (1 LTR) TANK TYPES WITH PAPER FILTER
WITHOUT SUPPORT 2
DIMENSIONS IN MILLIMETRES 1" = 25.4 millimetres
Hexagonal
Oultet
Hexagonal
Inlet Minimun thickness for the
95
SPECIAL VANE PUMPS
FR04000 (1.5 LTRS) AND Fr05000 (1 LTR) TANK TYPES WITH PAPER FILTER
Hexagonal
Inlet
Oultet
Hexagonal
Inlet
Hexagonal
Oultet
96
MHP & MD4C VANE MOTORS
VANE MOTORS
MHP & MD4C
97
MHP VANE MOTORS
F3 MHP 2 10 D 1 A
1 2 3 4 5 6 7
1 - "F3" means special seals for fire-resistant fluids. Omit if not required
2 - Motor Type:
3 - Motor Model:
Models 2
98
MHP VANE MOTORS
97
20
61
2,2 Kpm
58
Ø10,2
40
5 93
112
11
Inlet 3/4"
Outlet 1/2" BSP BSP
80 50 f7
MOTORS
Tooth number: 9
99
MD4C VANE MOTORS
2
MD4C 075 1 N 00 C 1 02 ..
BA
10 cSt
CCW Rotation: A= OUTLET 32
24 cSt DRAIN
B= INLET
Internal leakage (l/min)
28
24 B
20
16
A
DRAIN
12 01 02
8
4
0
0 35 100 140 175 P ressure (bar)
To r q u e T Poweroutput
Volumetric I n p u t f l o w a t n = 2000 R PM At n = 2000 R P M At n = 2000 R P M
M o del displacement (Vi)
Te órico a 175 bar p a 175 bar p a 175 bar p
100
MD4C VANE MOTORS
PORT CONNECTIONS 2
DRAIN SAE 6
Mounting (9/16" - 18 UNF)
torque OR 3/8" BSPP
A B (2 places)
A B
A B
Weight : 15,4 Kg
MOTORS
SHAFT TYPE
101
MD4C VANE MOTORS
100
2
MD4C 30
024 75
25
Torque T (Nm)
T=175 bar
Power (kW.)
20
T=140 bar P=175 bar
50 15
P=140 bar
T=105 bar
P=105 bar
10
25 T=70 bar P=70 bar
T=35 bar 5
P=35 bar
0 0
0 100 500 1000 1500 2000 2500 3000 3600
Velocidad (RPM)
100
30
MD4C
027 T=175 bar 25
75
20
Torque T (Nm)
Power (kW.)
50 P=140 bar
T=105 bar 15
P=105 bar
T=70 bar 10
P=70 bar
25
T=35 bar 5
P=35 bar
0 0
0 100 500 1000 1500 2000 2500 3000 3600
Velocidad (RPM)
100 35
MD4C T=175 bar
30
031
75 T=140 bar 25
Power (kW.)
Torque T (Nm)
0 0
0 100 500 1000 1500 2000 2500 3000 3600
Velocidad (RPM)
50
MD4C 150
T=175 bar 45
043 125 40
35
100 T=140 bar
Power (kW.)
Torque T (Nm)
P=175 bar 30
P=140 bar
75 T=105 bar 25
P=105 bar
20
50 T=70 bar P=70 bar 15
10
25 T=35 bar P=35 bar
5
0 0
0 100 500 1000 1500 2000 2500 3000 3600
Velocidad (RPM)
102
MD4C VANE MOTORS
MD4C
175 2
60
T=175 bar 55
150
055 50
125
T=140 bar 45
P=175 bar
40
Torque T (Nm)
Power (kW.)
100 T=105 bar P=140 bar 35
P=105 bar 30
75 25
T=70 bar
P=70 bar 20
50
15
T=35 bar
25 P=35 bar 10
5
0 0
0 100 500 1000 1500 2000 2500 3000 3600
Velocidad (RPM)
225 60
MD4C 200 55
T=175 bar
067 50
175 P=175 bar
P=140 bar 45
150 T=140 bar
40
Torque T (Nm)
Power (kW.)
P=105 bar
125 35
T=105 bar
30
100
25
75 T=70 bar
P=70 bar 20
50 15
T=35 bar 10
25 P=35 bar
5
0 0
0 100 500 1000 1500 2000 2500 3000 3600
Velocidad (RPM)
MOTORS
75 20
P=70 bar 15
50 T=35 bar
P=35 bar 10
25
5
0 0
0 100 500 1000 1500 2000 2500 3000 3600
Velocidad (RPM)
103
104
V* VANE PUMPS - INSTRUCTIONS FOR USE & REPAIRS
INSTRUCTIONS FOR
USE AND REPAIRS
Cartridge identification, change of rotation, guidelines for repairs.
V* series
105
V* VANE PUMPS - INSTRUCTIONS FOR USE & REPAIRS
IDENTIFICATION
Due to the difficulty in finding out spare cartridge references, either for the loss of the
pump feature plate, or for the lack of the machine spare part catalogue, it is most
convenient to include some sheets to identify the sample accurately and to give some
advice for a correct assembly.
To identify properly cartridge and pump, use the 3 following pages as follows:
106
V* VANE PUMPS - INSTRUCTIONS FOR USE & REPAIRS
IDENTIFICATION
B C
2 8 24 21 42
5 12 28 25 47
FLOW 8 14 30 50
9 17 35 57
in Gal. at 1.200 rpm 11 19 60
38
12 21 45 67
14 24 75
27
107
V* VANE PUMPS - INSTRUCTIONS FOR USE & REPAIRS
IDENTIFICATION
PUMP ROTATION
To determine pump rotation look at it from the shaft end side. If clockwise it is right hand
rotation, on the contrary, it is left hand rotation.
When taking out cartridge and putting it on to the outlet plate take into account that
rotation is seen the other way round; anyway, an arrow engraved in the ring or cam ring shows
the real turning sense. (See pictures.)
Support Bushing
Always mounted on the
inlet plate.
All single pumps have it.
LEFT RIGHT
RIGHT
LEFT
108
V* VANE PUMPS - INSTRUCTIONS FOR USE & REPAIRS
IDENTIFICATION
2
PUMP ROTATION
Support Bushing
Shaft End Cartridge Double pumps only wear it on the shaft
end cartridge (Cover end cartridges do not have it).
LEFT
hand rotation Pump LEFT
LEFT
RIGHT
hand rotation Pump RIGHT
RIGHT
109
V* VANE PUMPS - INSTRUCTIONS FOR USE & REPAIRS
Since this is a high precision kit (mechanized in tolerances within thousandth of millimeter), any abrasive
impurity can damage it in a few minutes or damage it to shorten its performance, before disassembling
it is necessary that working place, tools and worker handsare completely clean and neat.
Please avoid any blow, however insignificant, taking special care with all edge sides, ring seat points
and inlet and outlet plates.
1º Lean the cartridge, holding it tightly, at the work bench on the outlet plate. Loosen the 2 screws which
fix the kit, take them out as well as the pins (if there are any).
Take out inlet plate shifting it laterally, as due to the protective oil it may be gummed up. Place it at the
bench on a clean paper, white preferably.
3º Be sure there is no small dirty particles on the leaning surface, put ring on to the outlet plate, placing
it in the required turning sense. Make chamfer edge coincide, in which flow and arrow are engraved,
with inlet or admission port.
4º Set inlet plate, pins and the 2 screws as shown in the pictures, taking into account that the lattes must
be in opposite position to the ones they had before disassembling. (To do so, just turn ring, rotor and
vanes 180°). Fasten the screws moderately and dip the whole cartridge kit into clean hydraulic oil for a
while. After these steps it is ready to be assembled.
Please pay good attention to the cartridge and pump rotation, as they do not always coincide.
Be very careful to identify them properly. (See previous pages.)
110
V* VANE PUMPS - INSTRUCTIONS FOR USE & REPAIRS
A B
Fig. 1
A B
Outlet plate
Fig. 2
A B
A B
Fig. 3
A B
180º 180º
111
V* VANE PUMPS - INSTRUCTIONS FOR USE & REPAIRS
CARTRIDGE REPLACEMENT
3º - Should the used cartridge shows seizure in rotor, outlet & inlet plates, disassemble the
pump completely. Check that the key is in good condition (it could be cut out). Then, put the
shaft between points to make sure it is not twisted or crooked. Change it in case of any fault.
Take all the oil out of the circuit and other parts. Clean the tank carefully. If there is available
any used cartridge mount it and start the machine for at least 15 minutes, driving all controls.
To do so, spend the least possible amount of oil, since it will have to be replaced after this
operation, although it could be reused again, after being filtrated in a filter no bigger than 5
microns, as it still keeps additives).
Replace or clean all filters, mount the new cartridge and fill the tank to the level with new oil.
CARTRIDGE REPAIRS
MINIMAL CLEARANCE BETWEEN CAM RING AND ROTOR
112
V* VANE PUMPS - INSTRUCTIONS FOR USE & REPAIRS
20V 6,5
45V 35
45-20V 35 6,5
45-25V 35 10,5
45-35V 35
113
114
DT6 VANE PUMPS - INSTRUCTIONS FOR USE & REPAIRS
INSTRUCTIONS FOR
USE AND REPAIRS
Cartridge identification, change of rotation, guidelines for repairs.
DT6 series
115
DT6 VANE PUMPS - INSTRUCTIONS FOR USE & REPAIRS
PRIMING AT STARTING
Before starting the operation of TDZ hydraulics vane pumps, the following aspects should be always carefully
checked:
At first, start operation at lowest possible speed and pressure until regular operating fluid temperature is reached. If
a relief valve is used at the outlet, it should be backed off to minimize return pressure.
An air bleed off should be provided to purging of system air.
Vane pumps may present different external configurations depending on the inlet port position (located in the back
cover) in relation to the outlet port (located at the front flange or shaft end).
The inlet port may be in line with the outlet port, 90º to the right, 90º to the left or totally opposite to the outlet port
(180º).
These are the following steps that should be followed in order to modify the porting positions:
· Fix the pump in a working bench and loosen the 4 bolts that fix the back cover with the front body, (flange side
or shaft end part).
· Do not remove the 4 bolts totally. Remove approximately half of their total length them from the pump body.
· Separate the back cover from the front body by only 1mm 2mm maximum, turning the cover slightly to the right
and to the left, pushing it outwards.
· Using a sufficiently-long metal bar.
116
DT6 VANE PUMPS - INSTRUCTIONS FOR USE & REPAIRS
Vane pumps have a different external configuration, depending on the position of the suction flange (located on
the pump cover) in relation to the pressure flange (located on the coupling flange or shaft side).
The suction flange may be in line with the pressure flange, (o°), 90° to the right, 90° to the left or totally opposite it
(180º in relation to the pressure flange).
The steps to modify the position of the suction flange in relation to the pressure flange are as follows:
117
DT6 VANE PUMPS - INSTRUCTIONS FOR USE & REPAIRS
The cartridges on this type of pump available worldwide can be unidirectional or bidirectional. Rotation on
unidirectional cartridges cannot be modified, except where the cartridge pressure plates are replaced for others
with an opposite turning direction or for bidirectional plates.
TDZ cartridges are bidirectional. This means that rotation can be modified by means of a simple operation using
exactly the same cartridge components that are to be modified.
2.- Remove the cartridge suction cover. Of the two cartridge covers, the suction cover is the flattest and may be
fitted with a bronze bearing, depending on the position of the cartridge on the pump (P1, P2 or P3).
Next to the cover is a position pin that should also be removed.
3.- Remove the cam ring or stator and turn 180º so that side "A" of the stator that was previously in contact with
the surface of the suction cover is now touching the pressure cover and side “B” of the stator that was previously
in contact with the pressure cover is now touching the suction cover.
4.- Change the positioning pin on the pressure cover from hole "A" to hole "B" and re-insert the stator so that the
stator hole matches the new position of the pin.
5.- Also change the position pin on the suction cover and readjust the cover using the two screws. Turn the rotor
and the blades manually before tightening the screws.
Attentions: The screws are basically for alignment purposes. They must not be too tight. If the three parts of the
cartridge (stator, suction cover and pressure cover) are not perfectly concentric, it will be impossible to insert the
cartridge into the pump housing.
In this case, loosen the screws slightly and insert the entire cartridge into the body of the pump. When it is fully
inserted is when the cartridge parts are fully aligned and the screws can be readjusted.
118
NOTES
119
NOTES
120