Aws Application
Aws Application
Aws Application
CAUTION
If you install the ADS Software from another ADS version, a full instal-
lation from scratch is required.
A complete AWS software installation (from scratch) takes about 90
minutes.
A version update (installation from warm) takes between 40 and 90
minutes.
Before installing software, please check out the peripheral featuring delivered
with your system according to references listed below, and set the correct
peripheral on OS and software installing.
• Monitors
- 18" LCD monitor FRU: 2403952-4, original reference: 2403951-4
- 19" LCD monitor, original reference: 5148720-4
- 21" LCD monitor, original reference: 5350390
Table 1:
CAUTION
Installing from scratch will erase all data. Before starting, make sure all
images have been safely backed-up or archived.
Note down the ADS parameters as indicated in chapter System Identi-
fication and Follow-up of the Service Information and Procedures man-
ual
Note:
Material needed:
• AWS Operating System DVD-ROM,
• AWS Application DVD-ROM,
• Current IDC software CD-ROM
2-1. Operating System Installation
There are two possibilities:
1. If system is on:
• Load Solaris DVD-ROM into the ADS DVD drive.
• Shut down system
• Once system is OFF
• Switch cart power ON
2. If system is off:
• Switch cart power ON
• Insert quickly Solaris DVD-ROM into the ADS DVD drive
A first screen with "Jumpstart Installation" should appear.
If the "jumpstart installation" message is not displayed on the first screen,
5426228-4-1EN rev. 1 Page 4
Senographe Essential AWS S/W Installation Guide
wait for the login or grub prompt. Then, redo the procedure from step 3.
If the installation still does not start, follow the troubleshooting procedure in
section 5, Troubleshooting.
3. Press <Enter> to start installation.
Solaris installation starts.
2-2. Keyboard layout configuration
1. Use the arrow keys to move the cursor and the spacebar to select an item.
2. Select the installed keyboard conforming with the P/N list on page 2, then
press F2.
3. To select English language, type "0" and then press <Enter>.
! Notice:
Do not select anything else but US English. This is the Operating Sys-
tem installation language, not the application language.
Note:
In order to be able to type, the mouse must be inside the window.
4. To begin the installation process, click Next in the window.
2-3. Network parameters configuration
1. Select Networked for network connection (even if the system is not con-
nected to a network). Click Next.
2. Select e1000g0 as the primary network interface.
3. Select No for DHCP. Click Next.
CAUTION
First note down the ADS parameters as indicated in chapter System
Identification and Follow-up of the Service Information and Procedures
manual.
5426228-4-1EN rev. 1 Page 10
Senographe Essential AWS S/W Installation Guide
1. Shut down and reboot the AWS workstation.
2. At the login prompt log in as root.
3. Load the AWS Application DVD-ROM into the drive, then enter:
{Hostname} cd /cdrom/cdrom0/jumpstart↵
{Hostname} update.ads↵
4. The Console and AWS Installation windows are displayed:
Note:
AWS installation will take between 40 and 90 minutes.
Date : starting AWS installation [UPDATE] for [Ffdm]
----------------------------------------------------
- Hit <Enter> to install from cdrom or type “net” to install from the
network:
5. Press <Enter>
- Press <Enter> when CD inserted or [q/Q] to quit
6. Press <Enter>
7. Wait about one minute; messages indicating the following actions are dis-
played.
Verify CD...ADS application CD found
Installation directory is /cdrom/adsXX.XX
Software will be updated
ads packages de-installation
ads packages installation
Verify that all operations are "successful”.
Note:
GEMSiop package installation can take about an hour, according to the
number of images
Note:
If some packages installation are not “successful”, wait until the end of
the update and start again at the beginning of section 3, Update from
CD-ROM.
Clean ADS installation files.
5426228-4-1EN rev. 1 Page 11
Senographe Essential AWS S/W Installation Guide
“Workstation will reboot in 1 minute. Please wait”
After ADS installation, the system reboots automatically:
8. Log in as sdc.
9. In the displayed window, enter:
User: clinical↵
(and corresponding password clinical)↵
10. From behind the Browser, right click on the background, and from the
Root menu, select Service Tools > Command window.
A Command window appears with an ADS prompt.
11. Change to the ~sdc/senovision/scripts directory, by entering:
cd ~sdc/senovision/scripts
12. Specify the monitor resolution and pitch, by entering:
SetMonitorConfig.sh RESOLUTION PITCH
where the RESOLUTION and PITCH vary according to the list provided in
Table 3 below.
For example, if you have the 18” monitor (2403951-4), enter:
SetMonitorConfig.sh 1MP 90
Table 3:
13. The systems asks for the root password twice, enter it.
14. Reboot the system, by entering:
reboot
4. VERIFY INSTALLATION
In order to check proper installation or update, you shall launch the AWS
dr_ads utility, by following the steps below:
1. Reboot the system.
2. Login as sdc
User: clinical↵
(and corresponding password clinical)↵
3. On the AWS background screen, right click to open the Root Menu. Select
Service Tools, then Command Window.
4. From this window, login as root:
su - root↵
(and corresponding password when asked) ↵
5. Move to the dr ADS directory:
cd /export/home/install/jumpstart/DoctorAds↵
6. Start dr_ads, launching all tests in a row:
./dr_ads ↵
dr_ads main menu is displayed.
--------------------- Doctor ADS Tests -------------------------
0 - Perform all tests [1-17] 10 - Check IPC setting
1 - Perform visual check 11 - Check run level
2 - Check RAM size 12 - Check software key
3 - Check PCI boards 13 - Check hostname
4 - Check cdrom 14 - Check network
5 - Check disks 15 - Check users accounts
6 - Check ttys 16 - Check vital files
7 - Check packages/revisions 17 - Check optional CD-R drive
5426228-4-1EN rev. 1 Page 14
Senographe Essential AWS S/W Installation Guide
8 - Check partitions 18 - Perform Software tests
9 - Check patches 19 - Perform hardware tests
------------------------- Reports ------------------------------
80 - Display ADS configuration 83 - Display latest report
81 - Display customer data sheet
82 - Display latest errors
--------------------------- Tools ------------------------------
98 - Reset devices path.
99 - Reboot ADS
----------------------------------------------------------------
e - Exit
Your choice :
7. Select 0 - Perform all tests [1-17] to launch all tests. Press [RETURN] to
the first two questions.
Check Security Label is fixed as specified............................[ OK ]
Check HLB Label is fixed as specified.................................[ OK ]
Checking RAM size.....................................................[ OK ]
Checking Ethernet board...............................................[ OK ]
Checking Serial board.................................................[ OK ]
Checking Graphic board................................................[ OK ]
Checking Resolution...................................................[ OK ]
Checking CDROM drive..................................................[ OK ]
Checking disk.........................................................[ OK ]
Compare disk size.....................................................[ OK ]
Compare disk model....................................................[ OK ]
Checking serial ports settings........................................[ OK ]
Checking S/W Package installation.....................................[ OK ]
Checking disks partitions.............................................[ OK ]
Patches are no longer required for Sun U20............................[ OK ]
Checking IPC settings.................................................[ OK ]
Checking ADS run level................................................[ OK ]
Checking ADS mandatory S/W key........................................[ OK ]
Validating hostname settings..........................................[ OK ]
Checking /etc/hosts...................................................[ OK ]
Pinging remote nodes..................................................[ OK ]
Checking network interfaces...........................................[ OK ]
Checking users account................................................[ OK ]
Checking existence/permissions of ADS directories.....................[ OK ]
Checking existence/permissions of ADS executable files................[ OK ]
Checking existence/permissions of ADS script files....................[ OK ]
Checking existence/permissions of ADS configuration files.............[ OK ]
Checking existence/permissions of ADS Uptine/IQ files.................[ OK ]
Checking existence/permissions of ADS locale-specific files...........[ OK ]
Checking permissions of the /dev/null device..........................[ OK ]
Checking /export/home/sdc/.SdCrc sanity...............................[ OK ]
Checking $DISPLAY environment variable................................[ OK ]
Checking CD-R drive model.............................................[ OK ]
Checking CD-R Partition...............................................[ OK ]
5426228-4-1EN rev. 1 Page 15
Senographe Essential AWS S/W Installation Guide
---------------------------------------------------------------------
Dr ADS Results 11/04/2006 12:30:07: 0 ERROR(s) XX WARNING(s)
8. No errors should be listed. Warnings are acceptable.
Error and warning summaries are displayed by selecting option 82 -
Display latest errors from dr_ads main menu.
Note:
5. TROUBLESHOOTING
Note:
When executing the troubleshooting procedure, do not modify anything
else but what is described in this procedure.
Make sure "NUMLOCK" is not enabled on the keyboard.
1. Shutdown and reboot the system.
2. Press Delete to enter the BIOS.
3. Press F3 (Defaults optimized), then press Yes.
4. Press F4 (Save and Exit), then press Yes.