Therminol 59 Oil Properties
Therminol 59 Oil Properties
Therminol 59 Oil Properties
- 49 to 315 C
° °
(--56° to 600°F)
THERMINOL 59
®
ul
in
k
Therminol 59 fluid is designed for use in nonpressurized/
. us
us
e
e
low-pressure, indirect heating systems. While Therminol 59
te
te
m
m
p.
p.
has a relatively high normal boiling point (289°C/553°F), the
,–
–2
,6
80
56
25
00
0
recommended maximum bulk (315°C/600°F) and film (345°C/
°F
650°F) temperatures are greater. Therefore, proper care should
be taken in the design of the system to minimize leakage,
especially when operating above a bulk fluid temperature of
°C
288°C (550°F).
–1
–4
42
31
7
5
specifications for Therminol 59 fluid. bLiquid enthalpy basis is –17.8ºC (0ºF). c1 cSt = 1 mm2/s and 1 mPa•s =1 cP. d100 kPa =1 bar.
Liquid properties of Therminol® 59 heat transfer fluid by temperaturea
(English units)
Liquid
Liquid Heat of Liquid thermal Vapor
Temperature Liquid density heat capacity vaporization enthalpyb conductivity Liquid viscosityc pressured
°F °C lb/gal lb/ft3 Btu/(lb·°F) Btu/lb Btu/lb Btu/(ft·h·°F) lb/(ft·h) cSt (mm2/s) psia
–56 –49 8.55 64.0 0.349 167.1 –20.3 0.0726 4970 2000 —
–50 –46 8.53 63.8 0.352 166.3 –18.1 0.0725 2640 1070 —
–40 –40 8.49 63.5 0.356 164.9 –14.6 0.0723 1100 446 —
–20 –29 8.43 63.0 0.364 162.1 –7.4 0.0720 286 117 —
0 –18 8.36 62.5 0.373 159.4 0.0 0.0716 109 44.8 —
20 –7 8.29 62.0 0.381 156.7 7.5 0.0712 52.7 21.9 —
40 4 8.23 61.5 0.390 154.2 15.3 0.0708 30.2 12.7 —
60 16 8.16 61.0 0.398 151.7 23.1 0.0703 19.4 8.18 —
80 27 8.09 60.5 0.407 149.2 31.2 0.0699 13.5 5.74 —
100 38 8.02 60.0 0.416 146.8 39.4 0.0694 9.91 4.26 0.001
120 49 7.96 59.5 0.424 144.5 47.8 0.0689 7.63 3.31 0.003
140 60 7.89 59.0 0.433 142.2 56.4 0.0684 6.07 2.65 0.006
160 71 7.82 58.5 0.441 140.0 65.1 0.0679 4.95 2.19 0.011
180 82 7.75 58.0 0.450 137.8 74.0 0.0673 4.13 1.84 0.021
200 93 7.68 57.5 0.459 135.7 83.1 0.0668 3.50 1.57 0.036
220 104 7.62 57.0 0.468 133.6 92.4 0.0662 3.00 1.36 0.062
240 116 7.55 56.5 0.476 131.6 101.8 0.0656 2.61 1.19 0.102
260 127 7.48 55.9 0.485 129.6 111.4 0.0649 2.29 1.06 0.162
280 138 7.41 55.4 0.494 127.7 121.2 0.0643 2.03 0.945 0.251
300 149 7.34 54.9 0.503 125.8 131.2 0.0636 1.81 0.851 0.378
320 160 7.27 54.4 0.512 123.9 141.3 0.0629 1.62 0.771 0.557
340 171 7.19 53.8 0.520 122.0 151.7 0.0622 1.47 0.703 0.802
360 182 7.12 53.3 0.529 120.2 162.2 0.0615 1.33 0.645 1.13
380 193 7.05 52.7 0.538 118.3 172.8 0.0607 1.22 0.595 1.57
400 204 6.98 52.2 0.547 116.5 183.7 0.0600 1.11 0.551 2.14
420 216 6.90 51.6 0.556 114.7 194.7 0.0592 1.03 0.513 2.88
440 227 6.83 51.1 0.565 112.9 205.9 0.0584 0.948 0.479 3.81
460 238 6.75 50.5 0.574 111.1 217.3 0.0576 0.879 0.449 4.97
480 249 6.67 49.9 0.583 109.2 228.9 0.0567 0.817 0.422 6.41
500 260 6.59 49.3 0.593 107.4 240.7 0.0559 0.762 0.399 8.17
520 271 6.51 48.7 0.602 105.5 252.6 0.0550 0.713 0.378 10.3
540 282 6.43 48.1 0.611 103.6 264.7 0.0541 0.669 0.359 12.8
560 293 6.35 47.5 0.621 101.6 277.0 0.0532 0.629 0.342 15.9
580 304 6.26 46.9 0.630 99.6 289.6 0.0522 0.593 0.326 19.5
600 316 6.18 46.2 0.640 97.5 302.2 0.0513 0.560 0.313 23.6
620 327 6.09 45.5 0.649 95.4 315.1 0.0503 0.530 0.300 28.5
TLC Total Lifecycle Care®
When Therminol heat transfer fluids are used within suggested we can help improve system design, promote safety, and reduce
temperature limits, they may provide years of trouble-free service. overall cost. Customers can take advantage of Eastman’s heat
To help users get maximum life, Eastman offers testing of transfer system operation and product training programs. These
in-service heat transfer fluids to detect contamination, moisture, programs are customized to suit the varied needs of frontline
thermal degradation, and other conditions that may impact technicians, operations supervisors, and maintenance technicians
system performance. This comprehensive analysis includes to design engineers. Customers can also receive training assistance
acid number, kinematic viscosity, insoluble solids, low boilers, for dealing with important topics like fluid safety and handling.
related problem is suspected. safety awareness training that focuses on the design, start-up,
operation, and maintenance of heat transfer fluid systems.
Although the information and recommendations set forth herein are presented in good faith, Eastman Chemical
Company and its subsidiaries make no representations or warranties as to the completeness or accuracy thereof.
You must make your own determination of its suitability and completeness for your own use, for the protection
of the environment, and for the health and safety of your employees and purchasers of your products. Nothing
contained herein is to be construed as a recommendation to use any product, process, equipment, or formulation
in conflict with any patent, and we make no representations or warranties, express or implied, that the use thereof
will not infringe any patent. NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, OF
Eastman Chemical Company MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR OF ANY OTHER NATURE ARE MADE HEREUNDER
Corporate Headquarters WITH RESPECT TO INFORMATION OR THE PRODUCT TO WHICH INFORMATION REFERS AND NOTHING HEREIN
P.O. Box 431 WAIVES ANY OF THE SELLER’S CONDITIONS OF SALE.
Kingsport, TN 37662-5280 U.S.A.
Safety Data Sheets providing safety precautions that should be observed when handling and storing our products
U.S.A. and Canada, 800-EASTMAN (800-327-8626) are available online or by request. You should obtain and review available material safety information before
Other Locations, +(1) 423-229-2000 handling our products. If any materials mentioned are not our products, appropriate industrial hygiene and other
safety precautions recommended by their manufacturers should be observed.
www.eastman.com/locations
© 2015 Eastman Chemical Company. Eastman brands referenced herein are trademarks of Eastman Chemical
Company or one of its subsidiaries. The ® used on Eastman brands denotes registered trademark status in the U.S.;
marks may also be registered internationally. Non-Eastman brands referenced herein are trademarks of their
respective owners.
TF-24 12/15