AEC Q200 Rev C Complete
AEC Q200 Rev C Complete
AEC Q200 Rev C Complete
Acknowledgement
Any Document involving a complex technology brings together experience and skills from many sources.
The Automotive Electronics Council would especially like to thank the suppliers that provided input for this
document and recognize the following co-authors:
NOTICE
AEC documents contain material that has been prepared, reviewed, and approved through the AEC
Technical Committee.
AEC documents are designed to serve the automotive electronics industry through eliminating
misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement
of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for
use by those other than AEC members, whether the standard is to be used either domestically or
internationally.
AEC documents are adopted without regard to whether or not their adoption may involve patents or articles,
materials, or processes. By such action AEC does not assume any liability to any patent owner, nor does it
assume any obligation whatever to parties adopting the AEC documents. The information included in AEC
documents represents a sound approach to product specification and application, principally from the
automotive electronics system manufacturer viewpoint. No claims to be in Conformance with this document
may be made unless all requirements stated in the document are met.
Inquiries, comments, and suggestions relative to the content of this AEC document should be addressed to
the AEC Technical Committee on the link http://www.aecouncil.com.
This document may be downloaded free of charge, however AEC retains the copyright on this material. By
downloading this file the individual agrees not to charge for or resell the resulting material.
Copyright © 2005 by Delphi Electronics & Safety, Siemens VDO, and Visteon Corporation. This document
may be freely reprinted with this copyright notice. This document cannot be changed without approval by the
AEC Components Technical Committee.
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Table of Contents
Section Page
1.0 Scope 1
1.1 Description 1
1.1.1 Definition of Stress – Test Qualification 1
1.1.2 Approval for Use in an Application 2
1.2 Reference Documents 2
2.0 General Requirements 2-5
3.0 Qualification and Requalification 5-7
4.0 Qualification Tests 7-10
Table 1 – Qualification Sample Size Requirements 11-12
Table 2 – Table of Methods Referenced Tantalum and Ceramic 13-14
Table 2A – ceramic/Tantalum Process Change Qualification guidelines for the Selected Test 15
Table 3 - Table of Methods Referenced Aluminum Electrolytic Capacitors 16-17
Table 3A – Electrolytic Capacitor Process Change Qualification Guidelines for the Selected Test 18
Table 4 – Table Methods Referenced Film Capacitors 19-20
Table 4A – Film Capacitor Process Change Qualification Guidelines for the Selection of Test 21
Table 5 – Table of Methods Referenced Magnetics (Inductors/Transformers) 22-23
Table 5A – Inductive Products Process Change Qualification Guidelines for the selection of Test 24
Table 6 – Table of Methods Referenced Networks (R-C/C/R) 25-26
Table 6A/7A – Networks and Resistors Process Change Qualification Guidelines for Selection of Test 27
Table 7- Table of Methods Reference Resistors 28-29
Table 8 – Table of Methods Referenced Thermistors 30-31
Table 8A – Thermistor Process Change Qualification Guideline for the Selection of Test 32
Table 9 – Table of Methods Referenced Trimmer Capacitors/Resistors 33-34
Table 9A – Trimmers Capacitors/Resistors Process Change Qualification Guidelines for the
Selection of Test 35
Table 10 Table of Methods Referenced Varistors 36-37
Table 10A – Varistors Process Change Qualification Guidelines for the Selection of Test 38
Table 11 – Table of Methods Referenced Quartz Crystals 39-40
Table 11A – Quartz Crystal Process change Qualification guidelines for the Selection of Test 41
Table 12 – Table of Methods Referenced Ceramic Resonators 42-43
Table 12A – Ceramic Resonator Process Change Qualification Guidelines for the Selection of Test 44
Table 13 – Table of Methods Referenced Ferrite EMI Suppressors/Filters 45-46
Table 13A – Ferrite EMI Suppressors/Filters Process Change Qualification /Guideline for the Selection
of Test 47
Table 14 – Table of Methods Referenced Polymeric Resettable Fuses 48-49
Table 14A – Polymeric Resettable Fuses Process Change Qualification /Guideline for the Selection of
Test 50
Glossary of Terms/Abbreviations 51
Appendix 1 – Definition of a Qualification Family 52-54
Appendix 2 – Certificate of Design, Construction and Qualification (CDCQ) 55
Appendix 3 – Qualification Test Plan Format - Example 56-57
Appendix 4 – Data Presentation Format and Content - Example 58
Production Part Approval – Parametric Verification Summary – Example 59
Revision History 60
Attachment 1 AEC – Q200-001 Flame Retardance
Attachment 2 AEC – Q200-002 Human Body Model Electrostatic Discharge Test
Attachment 3 AEC – Q200-003 Beam Load (Break Strength) Test
Attachment 4 AEC – Q200-004 Resettable Fuse Test
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
1.0 SCOPE
1.1 Description
This specification defines the minimum stress test driven qualification requirements and
references test conditions for qualification of passive electrical devices. This document does not
relieve the supplier of their responsibility to meet their own company's internal qualification
program. In this document, "user" is defined as all companies that adhere to this document. The
user is responsible to confirm and validate all qualification and assessment data that
substantiates conformance to this document.
Qualification of the noted device type to it's minimum temperature grade allows the supplier to
claim the part as "AEC qualified" to that grade and all lesser grades. Qualification to
temperatures less than the minimum specified above would allow the supplier to claim the part as
"AEC qualified" at the lower grade only.
“Approval” is defined as user approval for use of part in the application. The user’s method of
approval is beyond the scope of this document.
Page 1 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Current revision of the referenced documents will be in effect at the date of agreement to the
qualification plan. Subsequent qualification plans will automatically use updated revisions of these
referenced documents.
1.2.1 Military/EIA
1.2.2 Industrial
1.2.3 AEC
2.1 Objective
The objective of this document is to ensure the device to be qualified meet the qualification
requirements detailed in Tables 2 - 14.
In the event of conflict in the requirements of this specification and those of any other documents,
the following order of precedence applies:
For the device to be considered a qualified part, the purchase order and/or individual device
specification cannot waive or detract from the requirements of this document.
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
2.3 The Use of Generic Data to Satisfy Qualification and Requalification Requirements
The use of generic data for qualification will be based on a matrix of specific requirements
associated with each characteristic of the device and manufacturing process as shown in
Tables 2-14 and Appendix 1.
Tables 2A-14A define a set of qualification tests that must be considered for any changes
proposed for the component. Tables 2A-14A matrix is the same for both new processes and
requalification associated with a process change. This table is a superset of tests that the
supplier and user should use as a baseline for discussion of tests that are required for the
qualification in question. All items in Tables 2-14 are tests that are required during component
qualification and must be considered during the development of a component qualification
plan. It is the supplier's responsibility to present rationale for why any of these tests need not
be performed.
Appendix 1 defines the criteria by which components are grouped into a qualification family for
the purpose of considering the data from all family members to be equal and generically
acceptable to the qualification of the device in question.
With proper attention to these qualification family guidelines, information applicable to other
devices in the family can be accumulated. This information can be used to demonstrate
generic reliability of a device family and minimize the need for device-specific qualification test
programs. This can be achieved through qualification of a range of devices representing the
“four corners” of the qualification family (e.g. highest/lowest voltage, high/mid/low value).
Sources of generic data shall come from certified test labs, and can include internal supplier's
qualifications, user-specific qualifications and supplier's in-process monitors. The generic data
to be submitted must meet or exceed the test conditions specified in Tables 2-14. End-point
test temperature must address worst-case temperature extremes and designed product life for
the applications. The user(s) will be the final authority on the acceptance of generic data in lieu
of specific device test data (to include temperature ranges of the devices.)
Testing for the failure mechanisms specific to each component technology should be available
to the user whenever a new technology or material relevant to the appropriate wearout failure
mechanism is to be qualified. The data, test method, calculations, and internal criteria need
not be demonstrated or performed on the qualification of every new device, but should be
available to the user upon request.
Note: This information may be subject to a confidentiality agreement, since it contains
proprietary information of the supplier.
Page 3 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
All qualification parts shall be produced on tooling and processes at the manufacturing site that
will be used to support part deliveries at projected production volumes.
Devices used for nondestructive qualification tests may be used to populate other qualification
tests. Devices that have been used for destructive qualification tests may not be used any
further except for engineering analysis.
All endpoint test temperatures (room, hot and cold) are specified in the "Additional
Requirements" column Tables 2-13 for each test. The specific value of temperature must
address the temperature extremes and designed product life for the application for at least one
lot of data (generic or part specific) submitted per test. For example, if the supplier designs a
device intended solely for use in a Grade 3 environment (e.g. -40°C to +85°C), his endpoint
test temperature extremes need only address those application limits. Qualification to
applications in higher-grade environments (e.g. -40°C to +125°C for Grade 1) will require
testing of at least one lot using these additional endpoint test temperature extremes. All
endpoint test conditions must include all user specifications for any given family.
Test failures are defined as those devices not meeting the individual device specification, post-
test criteria specific to the test or the supplier's data sheet in order of significance as defined in
Section 2.2. Any device that shows external physical damage attributable to the environmental
test is also considered a failed device. If the cause of failure is agreed (by the manufacturer
and the user) to be due to mishandling or ESD, the failure shall be discounted, but reported as
part of the data submission.
Page 4 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Passing all appropriate qualification tests specified in Tables 1 and 2-14, either by performing
the test (acceptance of zero failures using the specified minimum sample size) on the specific
part or demonstrating acceptable family generic data (using the family definition guidelines
defined in Appendix 1 and the total required lot and sample sizes), qualifies the device per this
document.
Passing the acceptance criteria of all the tests in Table 1 and the conditions in Tables 2-14
qualify the device per this document. When the number of failures for any given test in Table
1 exceeds the acceptance criteria using the procedure herein, the device shall not be qualified
until the root cause of the failure(s) is (are) determined and the corrective and preventive
actions are implemented and confirmed to be effective in an 8D or other acceptable user
format. New samples or data may be requested to verify the corrective and prevented action.
Any unique reliability test or conditions requested by the user and not specified in this
document shall be agreed upon between the supplier and user requesting the test, and will not
preclude a device from passing stress-test qualification as defined by this document.
The users, through supporting data presented by the supplier demonstrating equivalency, must
approve any deviation from the test requirements, listed in Table 1 and the test conditions
listed in Tables 2-14. These deviations will be clearly reported when the results of the
qualification are submitted to the user for approval.
Requirements for qualification of a new device are listed in Table 1, with the corresponding
test conditions listed in Tables 2-14. For each qualification, the supplier must present data for
ALL of these tests, whether it is stress test results on the device to be qualified or acceptable
generic family data. A review is to be made of other parts in the same generic family to ensure
that there are no common failure mechanisms in that family. Justification for the use of generic
data, whenever it is used, must be demonstrated by the supplier and approved by the user.
For each part qualification, the supplier must present a Certificate of Design, Construction and
Qualification data see Appendix 2.
Added requirements needed to address the special quality and reliability issues that arise when
lead (Pb) free processing is utilized is specified in Section 4. Materials used in lead-free
processing include the termination plating and the board attach (solder). These new materials
usually require higher board attach temperatures to yield acceptable solder joint quality and
reliability. These higher temperatures will likely adversely affect the moisture sensitivity level
of plastic packaged devices. As a result, new, more robust mold compounds may be required.
If an encapsulation material change is required to provide adequate robustness for Pb-free
processing of the device, the supplier should refer to the process change qualification
requirements in this specification. Preconditioning should be run at the applicable reflow
temperatures described in Section 4 wherever it is required before environmental stress tests.
Page 5 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Requalification of a device shall be required when the supplier makes a change to the product
and/or process that impact the form, fit, function, quality and reliability of the device.
The supplier shall submit a projection to the users of all forecasted process changes. This
projection of implemented changes shall be submitted at least 6 months in advance.
Information required for submission to the user will include the following as a minimum:
1. Benefit to the user (value, time and quality).
2. For each user part numbers involved in the change, the following information is required:
a) Supplier part number
b) An estimated date of the last production lot of unchanged parts.
c) An estimated final order date and final ship date of unchanged parts.
d) The first projected shipment date and date code of changed parts.
A detailed description of the change in terms of the materials, processes,
visual/electrical/mechanical characteristics, rating, circuit design, internal element layout and
size as applicable.
4. Technical data and rationale to support the proposed changes.
5. An electrical characterization comparison (between the new and original product) of
all significant electrical parameters over temperature extremes that the change could
affect. Changes in median and dispersion performances shall be noted even though
conformance to specification limits is still guaranteed.
6. The supplier shall submit an updated Certificate of Design, Construction and Qualification
along with information required by this section (section 3.2.1) plus any changes impacting
Appendix 2 information as originally submitted.
7. The results of completed supplier Requalification tests of the changed device(s).
Items 1, 2, 3, & 4 are background information needed up front to evaluate the impact of the
change on supply and reliability and to come to agreement on a qualification plan acceptable
to the supplier and user. Items 5, 6 and 7 must be submitted prior to any final approval to
implement any change on the user's product. No change shall be implemented without
prior approval of the users.
As a minimum, any change to the product, as defined in Appendix 1, requires performing the
applicable tests listed in Tables 1 and 2-14. Table 2A-14A will be used as a guide for
determining which tests need to be performed or whether equivalent generic data can be
submitted for that test. These tables include requirements for comparative testing of parts
produced before the change to parts produced after. At a minimum, electrical characterization
test #19 should be performed on a comparative basis. An agreement between the supplier
and the user(s) with justification for performing or not performing any recommended test shall
occur before the implementation of a Requalification plan.
It is the responsibility of each user to review the data, change notices, and supporting
documentation to either qualify or not qualify the change based on the results of the tests
performed. All criteria requirements described in 2.6 apply.
Page 6 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
A change may not affect a part's qualification status, but may affect its performance in an
application. Individual user authorization of a process change will be required for that user's
particular application(s), and this method of authorization is outside the scope of this
document.
Test details are given in Tables 1-14. Not all tests apply to all devices. For example, certain
tests apply only to hermetically packaged devices, others apply only to SMD large can
devices, and so on. The applicable tests for the particular device type are indicated in the
"Note" column of Table 1 and the "Additional Requirements" in Tables 2-14. The "Additional
Requirements" column of Tables 2-14 also serves to highlight test requirements that
supersede those described in the referenced test.
The following tests must be performed on the specific device to be qualified for all devices.
Generic data is not allowed for these tests. Device specific data, if it exists, is acceptable.
2. Electrical Characterization - The supplier must demonstrate that the part is capable of
meeting parametric limits detailed in the individual user device specification. This data
must be taken from at least three lots of the required sample size over the specified
temperature range.
3. Additional Environmental Testing may be required because of the user's experience with
the supplier.
Page 7 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
4.3.1 Solderability
The qualification requirements outlined in Table 4.1 are to act as a supplement to EIA/JESD22-
B102 Solderability Test Method. The solderability (test #18) and resistance to solder heat
(test #15) tests are still required to be performed on Pb-free components for backward
compatibility with Pb processes. A single lead-free solder solution has not been industry
standardized as has eutectic tin-lead solder. For different formulations of solder, the chemistry,
reflow temperatures and joint reliability may vary widely. Thus, until one can be standardized, the
supplier must use the user's recommended solder and flux for performing solderability testing for
that user. Steam age preconditioning is performed before the solderability test to simulate the
oxidation of the termination plating that can develop over a long storage time. This oxidation can
minimize the solder coverage via pinholes, voids, porosity, nonwetting and dewetting and produce
poor solder strength or poor reliability.
The table in this section below serves as the recommended environmental tests that the supplier
should consider when qualifying a new or changed Pb-free component. The supplier can
propose, with technical justification, a subset of the recommended tests for a given component
type.
Preconditioning is used to simulate the thermal stress devices must endure during attachment to
circuit boards in electronic system manufacturing. These stresses become more severe and,
thus, more important to simulate when higher Pb-free temperatures are used. These stresses
can then influence the functional life of the device, which is why preconditioning is required
before environmental life stress tests.
Page 8 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Refer to Table 4.2 to determine the maximum number of reflows before the appropriate reliability
stress test for a given type of passive component. The difference in the number of reflows
represents the differences in capability among the various types of passive devices. The peak
reflow temperature for Pb-free forward compatibility, measured as the reflow oven ambient, is
O
260(+0/-5) C when attaching surface mount passive devices onto test boards. If the supplier
O
feels their component cannot endure a 260 C reflow and demonstrate acceptable life, perform a
lower reflow precondition temperature, informing the user immediately of this deviation.
Term Str
Bd Flex
Tests after Preconditioning
HTE
MR
BH
TC
OL
TS
Type of Component
Ceramic/Tantalum Capacitor 3 3 3 3 3 3 3 3
Electrolytic/Film Capacitor C/ 2 2 2 2 2 2 2 2
Resistor 3 3 3 3 3
Inductor 2 2 2 2 2 2 2 2
PTC Polymer Thermistor B/ B/ B/ B/ B/
PTC Ceramic Thermistor 2 2 2 2 2
NTC Thermistor 2 2 2 2 2
Trimmer 2 2 2 2 2 2
Varistor 2 2 2 2 2 2 2 2
Resonator/Crystal 2 2 2 2 2
Attenuator 2 2 2 2 2 2 2 2
A/ moisture soaking to MSL 1 before reflow for plastic packaged SMD capacitors, inductors and
attenuators only. If device is incapable of MSL1, can soak at MSL3 before reflow, but parts must
be drypacked for shipment to user.
B/ three reflow passes at 260ºC/20 seconds (instead of 10 seconds) onto test boards
C/ Aluminum electrolytics must be allowed to cool after the first and before the second reflow
passes
Page 9 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Perform this test per section 4.2.4 of J-STD-002 using a solder dip temperature of 260 +0/-5 C.
Table 4.2
ISSUE PASSIVE DEVICES
Qualification Requirements AEC-Q200
Resistance to Dissolution of J-STD-002
Metallization Section 4.2.4
260+0/-5C
Tin whisker growth is more likely to occur, influenced by complex material and processing
conditions, when tin termination plating is used. This is a wearout reliability issue in that these
whiskers can grow to contact adjacent terminations to cause false data pulses, intermittent
failures and, in extreme circumstances, electrical overstress.
If using tin without an underlayer (e.g., Ni) as the termination plating, it must be deposited in a
very clean environment and must display a matte finish. In addition, some studies have shown
O
that a tin plating thickness >7um, a nickel underlayer and/or a postbake at 150 C/1 hour will
minimize the likelihood of whisker growth. These conditions have been identified as major
factors in minimizing tin whisker growth.
Suppliers must test for susceptibility to whisker growth during device aging. After each stress,
the terminations shall be observed visually using a high power (>50X) microscope. Any
termination displaying a whisker filament greater than or equal to 50um in total axial length shall
constitute a failure.
Page 10 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
The above inspection intervals and minimum durations are based on experimental data and are
given to make data comparisons easier. Total test durations (cycles/hour) are not specified in
JESD22 Method A121. Some experimental data suggests that there is an incubation time during
which whiskers do not appear. This incubation time depends on lead finish, thickness of the finish
and substrate characteristics. If test durations are too short, whiskers will not be observed. For
qualification of lead finishes, test duration and inspection intervals will be defined in the qualification
plan agreed to by the supplier and user.
Data summary shall be submitted as defined in Appendix 4. The individual user shall submit raw
data and histograms upon request. All data and documents (e.g., justification for non-performed
test, etc.) shall be maintained by the supplier in accordance with QS-9000 / TS-16949
requirements.
Page 11 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
High Temperature 3 DG 77 1 0
Exposure Note B
Temperature Cycling 4 DG 77 1 0
Note B
1
Destructive Physical 5 DG 5 0
Analysis Note B
77
Moisture Resistance 6 DG 1 0
Note B
Humidity Bias 7 DG 77 1 0
Note B
High Temperature 8 DG 77 1 0
Operating Life Note B
Physical Dimensions 10 NG 30 1 0
Resistance to Solvent 12 DG 5 1 0
Mechanical Shock 13 DG 30 1 0
Vibration 14 DG Note B
Thermal Shock 16 DG 30 1 0
ESD 17 D 15 1 0
Page 12 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Electrical 19 NG 30 3 0
Characterization Note A
Board Flex 21 DS 30 1 0
Terminal Strength 22 DS 30 1 0
(SMD)
Beam Load 23 DG 30 1 0
Flame Retardance 24 DG 30 1 0
Rotation Life 25 DG 30 1 0
Surge Voltage 27 DG 30 1 0
Salt Spray 29 DG 30 1 0
Electrical Transient 30 DG 30 1 0
Conduction
Note: A For parametric verification data, sometimes circumstances may necessitate the acceptance
of only one lot by the user. Should a subsequent user decide to use a previous user’s
qualification approval, it will be the subsequent user’s responsibility to verify that an acceptable
number of lots was used.
B Where generic (family) data is provided in lieu of component specific data, 3 lots are required.
C The solderability (test #18) and resistance to solder heat (test #15) tests are still required to be
performed on Pb-free product for backward compatibility with Pb processes.
D Destructive test, devices are not to be reused for qualification or production.
G Generic data allowed. See Section 2.3.
H Required for hermetic packaged devices only.
L Required for leaded devices only.
N Nondestructive test, devices can be used to populate other tests or they can be used for
production.
S Required for surface mount devices only.
Page 13 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 14 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 15 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 16 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 17 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Note: A letter or " " indicates that performance of that stress test should be considered for the appropriate process change
a = termination equipment only B = comparative data (unchanged vs. Changed) required c = Ceramics only
Page 18 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 19 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 20 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
TABLE 3A - Electrolytic Capacitor Process Change Qualification Guidelines for the Selection of Tests
3. High Temperature Exposure (Storage) 12. Resistance to Solvents 21. Board Flex
4. Temperature Cycling 13. Mechanical Shock 22. Terminal Strength (SMD)
14. Vibration 27. Surge Voltage
6. Moisture Resistance 15. Resistance to Soldering Heat
7. Biased Humidity 16. Thermal Shock
8. Operational Life 17. Electrostatic Discharge (ESD)
9 External Visual 18. Solderability
10. Physical Dimension 19. Electrical Characterization
11. Terminal Strength (Leaded) 20. Flammability
Note: A letter or " " indicates that performance of that stress test should be considered for the appropriate process change
Page 21 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 22 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 23 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
TABLE 4A - Film Capacitor Process Change Qualification Guidelines for the Selection of Tests
3. High Temperature Exposure (Storage) 12. Resistance to Solvents 21. Board Flex
4. Temperature Cycling 13. Mechanical Shock 22. Terminal Strength (SMD)
14. Vibration
6. Moisture Resistance 15. Resistance to Soldering Heat
7. Biased Humidity 16. Thermal Shock
8. Operational Life 17. Electrostatic Discharge (ESD)
9 External Visual 18. Solderability
10. Physical Dimension 19. Electrical Characterization
11. Terminal Strength (Leaded) 20. Flammability
Note: A letter or " " indicates that performance of that stress test should be considered for the appropriate process change
Page 24 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 25 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 26 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
TABLE 5A - Inductive Products Process Change Qualification Guidelines for the Selection of Tests
3. High Temperature Exposure (Storage) 12. Resistance to Solvents 21. Board Flex
4. Temperature Cycling 13. Mechanical Shock 22. Terminal Strength (SMD)
14. Vibration
6. Moisture Resistance 15. Resistance to Soldering Heat
7. Biased Humidity 16. Thermal Shock
8. Operational Life 17. Electrostatic Discharge (ESD)
9 External Visual 18. Solderability
10. Physical Dimension 19. Electrical Characterization
11. Terminal Strength (Leaded) 20. Flammability
Note: A letter or " " indicates that performance of that stress test should be considered for the appropriate process change
Page 27 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 28 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 29 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
TABLE 6A/7A - Networks and Resistors Process Change Qualification Guidelines for the Selection of Tests
3. High Temperature Exposure (Storage) 12. Resistance to Solvents 21. Board Flex
4. Temperature Cycling 13. Mechanical Shock 22. Terminal Strength (SMD)
14. Vibration 24. Flame Retardance
6. Moisture Resistance 15. Resistance to Soldering Heat 29. Salt Spray
7. Biased Humidity 16. Thermal Shock
8. Operational Life 17. Electrostatic Discharge (ESD)
9 External Visual 18. Solderability
10. Physical Dimension 19. Electrical Characterization
11. Terminal Strength (Leaded) 20. Flammability
Note: A letter or " " indicates that performance of that stress test should be considered for the appropriate process change
R = Resistors Only F = Film products only B = comparative data (unchanged vs. Changed) required
N = Networks Only W = Wirewound products only
Page 30 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 31 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 32 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 33 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 34 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
TABLE 8A - Thermistor Process Change Qualification Guidelines for the Selection of Tests
3. High Temperature Exposure (Storage) 12. Resistance to Solvents 21. Board Flex
4. Temperature Cycling 13. Mechanical Shock 22. Terminal Strength (SMD)
14. Vibration
6. Moisture Resistance 15. Resistance to Soldering Heat
7. Biased Humidity 16. Thermal Shock
8. Operational Life 17. Electrostatic Discharge (ESD)
9 External Visual 18. Solderability
10. Physical Dimension 19. Electrical Characterization
11. Terminal Strength (Leaded) 20. Flammability
Note: A letter or " " indicates that performance of that stress test should be considered for the appropriate process change
Page 35 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 36 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 37 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
TABLE 9A - Trimmers Capacitors/Resistors Process Change Qualification Guidelines for the Selection of Tests
3. High Temperature Exposure (Storage) 12. Resistance to Solvents 21. Board Flex
4. Temperature Cycling 13. Mechanical Shock 22. Terminal Strength (SMD)
14. Vibration 25. Rotation Life
6. Moisture Resistance 15. Resistance to Soldering Heat
7. Biased Humidity 16. Thermal Shock
8. Operational Life 17. Electrostatic Discharge (ESD)
9 External Visual 18. Solderability
10. Physical Dimension 19. Electrical Characterization
11. Terminal Strength (Leaded) 20. Flammability
Note: A letter or " " indicates that performance of that stress test should be considered for the appropriate process change
Page 38 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 39 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 40 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
TABLE 10A - Varistors Process Change Qualification Guidelines for the Selection of Tests
3. High Temperature Exposure (Storage) 12. Resistance to Solvents 21. Board Flex
4. Temperature Cycling 13. Mechanical Shock 22. Terminal Strength (SMD)
14. Vibration 30. Electrical Transient Conduction
6. Moisture Resistance 15. Resistance to Soldering Heat
7. Biased Humidity 16. Thermal Shock
8. Operational Life 17. Electrostatic Discharge (ESD)
9 External Visual 18. Solderability
10. Physical Dimension 19. Electrical Characterization
11. Terminal Strength (Leaded) 20. Flammability
Note: A letter or " " indicates that performance of that stress test should be considered for the appropriate process change
Page 41 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 42 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 43 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
TABLE 11A- Quartz Crystal Process Change Qualification Guidelines for the Selection of Tests
3. High Temperature Exposure (Storage) 12. Resistance to Solvents 22. Terminal Strength (SMD)
4. Temperature Cycling 13. Mechanical Shock
14. Vibration
6. Moisture Resistance 15. Resistance to Soldering Heat
7. Biased Humidity 16. Thermal Shock
8. Operational Life 18. Solderability
9 External Visual 19. Electrical Characterization
10. Physical Dimension 20. Flammability
11. Terminal Strength (Leaded) 21. Board Flex
Note: A letter or " " indicates that performance of that stress test should be considered for the appropriate process change
Test # From Table 11 3 4 6 7 8 9 10 11 12 13 14 15 16 18 19 20 21 22
MATERIAL
Quartz Blank B
Base
Lead/Termination B
Glass Seal B
Can/Cap
Blank Support B
Overmold
Case Sealing B
Electrode
Insulator B
PROCESS
Quartz Blank B
Base Assembly
Blank Etch/Clean B
Electrode Formation B
Auto Trim B
Bond/Anneal Blank B
Cap/Can Attach B
Overmolding B
Marking
Aging B
DESIGN
Quartz Blank B
Base
Lead/Termination B
Can/Cap B
Blank Support B
Package (Molded) B
Insulator
MISCELLANEOUS
Mfg. Site Transfer B
Material Suppliers B
Process Control
Change
Page 44 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 45 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 46 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
TABLE 12A - Ceramic Resonator Process Change Qualification Guidelines for the Selection of Tests
3. High Temperature Exposure (Storage) 12. Resistance to Solvents 22. Terminal Strength (SMD)
4. Temperature Cycling 13. Mechanical Shock
14. Vibration
6. Moisture Resistance 15. Resistance to Soldering Heat
7. Biased Humidity 16. Thermal Shock
8. Operational Life 17. Electrostatic Discharge (ESD)
9 External Visual 18. Solderability
10. Physical Dimension 19. Electrical Characterization
11. Terminal Strength (Leaded) 21. Board Flex
Note: A letter or " " indicates that performance of that stress test should be considered for the appropriate process change
Page 47 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 48 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
ESD 17 AEC-Q200-
002
Solderability 18 J-STD-002 For both Leaded & SMD. Electrical Test not
required. Magnification 50 X. Conditions:
Leaded: Method A @ 235°C, category 3.
SMD: a) Method B, 4 hrs @ 155°C dry heat @
235°C
b) Method B @ 215°C category 3.
c) Method D category 3 @ 260°C.
Electrical 19 User Spec. Parametrically test per lot and sample size
Characterization requirements, summary to show Min, Max, Mean
and Standard deviation at room as well as Min and
Max operating temperatures.
Flammability 20 UL-94 V-0 or V-1 are acceptable. Electrical Test not
required.
Board Flex 21 AEC-Q200- Appendix 2 Note: 2mm (min)
005
Terminal Strength 22 AEC-Q200- Appendix 1 Note: A force of 1.8kg for 60 seconds.
(SMD) 006
TEST NOT USED 26 ------------ ------------------------------------------------------------------
Electrical 30 ISO-7636-1 Test pulses 1 to 3
Transient
Conduction
Page 49 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
TABLE 13A - Ferrite EMI Suppressor/ Filter Process Change Qualification Guidelines for the Selection of Tests
3. High Temperature Exposure (Storage) 12. Resistance to Solvents 21. Board Flex
4. Temperature Cycling 13. Mechanical Shock 22. Terminal Strength (SMD)
5. Destructive Physical Analysis 14. Vibration 30. Electrical Transient Conduction
15. Resistance to Soldering Heat 31. Shear Strength
7. Biased Humidity 16. Thermal Shock
8. Operational Life 17. Electrostatic Discharge (ESD)
9 External Visual 18. Solderability
10. Physical Dimension 19. Electrical Characterization
11. Terminal Strength (Leaded) 20. Flammability
Note: A letter or " " indicates that performance of that stress test should be considered for the appropriate process change
Page 50 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Page 51 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Note: Pre stress electrical tests also serve as electrical characterization if required data per
Stress 19 is collected at that time.
Page 52 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
TABLE 14A – Polymeric Resettable Fuses Process Change Qualification Guidelines for the Selection of Tests
Note: A letter or “ “ indicates that performance of that stress test should be considered for the appropriate process change.
Note 1: For parts marked with ink only. Laser and stamped marked parts shall be exempt from this test.
Note 2: Test numbers are the last sub paragraph numbers of requirements or procedure paragraphs.
B = comparative data (unchanged vs. Changed) required
Page 53 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
GLOSSARY OF TERMS/ABBREVIATIONS
Page 54 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
The qualification of a particular process will be defined within, but not limited to, the categories listed below. The
supplier will provide a complete description of each process, case size and material of significance. There must
be valid and obvious links between the data and the subject of qualification.
For devices to be categorized in a qualification family, they all must share the same major process and materials
elements as defined below. All devices using the same process and materials are to be categorized in the same
qualification family for that process and are qualified by association when one family member successfully
completes qualification with the exception of the device specific requirements of section 4.2.
Prior qualification data 2 years old or newer obtained from a device in a specific family may be extended to the
qualification of subsequent devices in that family provided the supplier can insure no process changes have been
made.
For broad changes that involve multiple attributes (e.g. site, material(s), process(es)), refer to section 2.3, which
allows for the selection of worst-case test vehicles to cover all the possible permutations.
1. Sub Assembly
Each process technology must be considered and qualified separately. No matter how similar, processes from
one fundamental technology cannot be used for the other.
Family Requalification with the appropriate tests is required when the process or a material is changed. The
important attributes defining a qualification family are listed below:
1) CAPACITOR TECHNOLOGY
* Aluminum Electrolytic
* Tantalum
* Ceramic
* Film
* Networks
* Trimmers
2) RESISTOR TECHNOLOGY
* Thin Film
* Thick Film
* Networks
*Trimmers
* Wirewounds
* Molded Metal Strip
3) INDUCTORS
* Fixed (Axial/Radial/SMD)
* Ferrite Cores
* Wirewound
* Multilayer
* Variable
4) TRANSFORMERS
* Pulse Transformers
* SMD (for DC TO DC CONVERTERS)
* Switch Mode Power Transformers
* SMD (for Pulse Applications)
Page 55 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
5) VARISTORS
* Ring Varistors (Barium-Titanium Oxide)
* Disc Varistors (Zinc Oxide)
* Multilayer Surface Mounted Varistors
6) THERMISTORS
* For Motor Starting
* For Overcurrent Limiting
* For Temperature Compensation
7) CRYSTALS
* Metal AT CUT
* Metal AT STRIP
* Molded Surface Mounted
* Tuning Fork
8) RESONATORS
* Ceramic
* SAW resonators
2. Assembly Process
The processes for each package type must be considered and qualified separately. For
devices to be categorized in a qualification family, they all must share the same major process
and material elements as defined below. Family Requalification with the appropriate tests are
required when the process or a material is changed. The supplier must submit technical
justification to the user to support the acceptance of generic data with package type if
different than the device to be qualified.
2) Assembly Site
When the specific product or process attribute to be qualified or requalified will affect more than a family, the
qualification test vehicles should be three lots of a single device type from each of the technology and package
families that are projected to be most sensitive to the changed attribute with sample sizes split to include a
minimum of 30 pieces from each of 3 assembly lots from each assembly site.
Below is the recommended process for qualifying changes across many process and product families:
2) Identify the critical structures and interfaces potentially affected by the proposed change.
3) Identify and list the potential failure mechanisms and associated failure modes for the critical structures
and interfaces.
Page 56 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
4) Define the product groupings or families based upon similar characteristics as they relate to the
technology process and package families and device sensitivities to be evaluated, and provide technical
justification for these groupings.
5) Provide the qualification test plan, including a description of the change, the matrix of tests and the
representative products, which will address each of the potential failure mechanisms and associated
failure modes.
6) Robust process capability must be demonstrated at each site (e.g. control of each process step,
capability of each piece of equipment involved in the process, equivalence of the process step-by-step
across all affected sites) for each of the affected process step(s).
Page 57 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
The following information, as applicable, is required to identify a component, which has met the requirements of
this specification. This page is available as a stand-alone document.
Attachments: Requirements:
1) Cross section photo. 1) A separate CDCQ shall be submitted for
2) Package outline drawing. each family as defined by Appendix 1 and
3) Special test circuits. Appendix 2
4) Letter stating exceptions taken
to AEC-Q200.
2) Document shall be signed by a responsible individual at
the supplier who can verify that all of the above
information is correct.
Page 58 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
The supplier is requested to complete and submit the Passive Component Qualification Plan as part of
the pre-launch Control Plan whenever production approval submission is required. Acceptance and
subsequent sign-off of the plan will establish a qualification agreement between the user and the supplier
determining requirements for both new parts and process changes prior to commencement of testing.
Where “family” data is being proposed, the plan will document how the reliability testing previously
completed fulfills the requirements outlined in this specification. An approved copy of the qualification
plan should be included with each production approval submission.
The test plan section of the form should detail ONLY the testing that will be performed on the specific
part shown. Testing MUST include the additional requirements listed in the applicable table 2-14.
For process change qualifications, multiple parts can be included on the same plan. Supporting generic
or family data reports should be noted in the comment section and attached. When requesting use of
generic or family data, attach a separate page detailing similarities or differences between parts
referencing the criteria in Appendix1. There must be valid and obvious links between the data and the
subject of qualification.
The example below is provided to demonstrate how the Qualification Plan Form should be used. In this
case, a ceramic multilayer capacitor was chosen as being representative of a typical new part
qualification requesting reduced component testing by including generic test data. The part comes from a
supplier who previously qualified the package, assembly site etc. This EXAMPLE is shown for illustration
purposes only and should not limit any requirements from Table 1 – 14 herein.
Page 59 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Item Test Test conditions Exceptions Est. Start Est. # Lots S. S. Additional Requirements
Comp.
1. Supplier requests 1 lot qualification of this device type in addition to attached reliability reports of similar parts.
Page 60 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
The supplier is required to complete and submit an Environmental Test Summary and Parametric
Verification Summary with each Passive Component production approval submittal. Figure 4-1 is an
EXAMPLE of a completed Environmental Test Summary. The format shall be followed.
EXAMPLE
Page 61 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Figure 4-2 is an EXAMPLE of a completed Parametric Verification Summary. The format shall be
followed.
Page 62 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Revision History
Rev # Date of change Brief summary listing affected paragraphs
Page 63 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
(2.4.3) editorial
(3.2) Added section: Qualification of a Lead (Pb) – Free
Device
(3.3.2) comparative testing of parts
(4.3) Added section: Lead (Pb) – Free Specific Tests
(4.4) Data maintenance per TS-16949
Table 1: Solderability note C and legend description
Test 21: AEC-Q200-005 reference in Table of Tests
Test 22: AEC-Q200-006 reference in Table of Tests
Test 19: B reference in Change tables and legend description
Test 27: AEC-Q200-007 reference in Table of Tests
Test 8: MIL-PRF-27 reference in Table of Tests #5
Appendix 1, family 7 & 8
Page 64 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
ATTACHMENT 1
Page 65 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
METHOD - 001
PASSIVE COMPONENT
FLAME RETARDANCE
TEST
1.0 SCOPE
1.1 DESCRIPTION:
The purpose of this specification is to assure a device will not flame due to self-heating when full
automotive battery potential is applied. This test applies to all devices that, under normal
operation, are not intended for use at full automotive battery potential.
Not Applicable
2.0 EQUIPMENT:
The total number of components and lots to be tested are listed in Table 1 of AEC-Q200 specification.
Devices shall be mounted to the test board in their normal mounting configuration and subjected
to voltages from 9.0 to 32.0 VDC (current clamped up to 500A) in 1.0 VDC increments. Each
voltage level shall be applied for a minimum of one hour, or until the device is either electrically
open or a failure described in Paragraph 4.0 occurs. The test board shall be horizontal, with the
component on the underside if a leaded device and on the top side if a surface mounted device.
The test shall be conducted at 22C ± 5C in still air. The temperature sensor shall be placed in
contact with, but not adhered to, the outer surface of the device centered along its body for parts
rated at one Watt and below, or at a distance of 1mm from the outer surface of the device body
for devices rated above one Watt, as illustrated in Figure 1.
Page 66 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
3.3 Measurement:
Prior to Flame Retardance testing, complete the electrical characterization (TST NO. 19)
functional tests. The DC current shall be monitored continuously during the test to determine
when the device is electrically open. The temperature sensing and recording system shall
monitor temperature throughout the test.
Figure 1 Leaded and Surface Mount Device Temperature Sensor contact points
b) An explosion
Any device that electrically opens or changes value outside part tolerance without causing any of
the above shall not be considered a failure. Should a device open prior to attaining the maximum
voltage or current described in 3.0, that device shall be replaced. The replaced device shall be
subjected to 32 VDC current clamped up to 500 ADC and decreased in 1.0 VDC/hour
increments until the voltage at which the first device opened is attained or until all parts are
open, whichever occurs first. This assures that the part will meet specification requirements
throughout the required test voltage range.
Page 67 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Revision History
Page 68 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
ATTACHMENT 2
Page 69 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
METHOD - 002
PASSIVE COMPONENT
HUMAN BODY MODEL (HBM)
ELECTROSTATIC DISCHARGE (ESD)
TEST
1.0 SCOPE
1.1 Description:
The purpose of this specification is to establish a reliable and repeatable procedure for
determining passive component HBM ESD sensitivity.
A condition in which a component does not meet all the requirements of the acceptance criteria,
as specified in section 5 following the ESD test.
Page 70 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
An instrument that simulates the passive component human body model ESD pulse as defined
in this specification.
A common electrical reference point for the DUT, ESD simulator, and auxiliary equipment.
The maximum ESD voltage at which, and below, the component is determined to pass the
failure criteria requirements specified in section 4.
1.3.9 PUT:
Page 71 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
2.0 EQUIPMENT:
The apparatus for this test consists of an ESD pulse simulator with an equivalent passive
component HBM ESD circuit as shown in Figure 1. The simulator must be capable of supplying
pulses that meet the waveform requirements of Table 1 and Figure 3 using the coaxial target
specified in section 2.2.1.
High Voltage
Relay
Rch Rd
Discharge
100 Mohm 2000 ohm Tip
Discharge
Return
Connection
Direct Contact Adapter Ground Plane
(if applicable)
Equipment used to verify conformance of the simulator discharge waveform to the requirements
as specified in Table 1 and Figure 3 shall be either an analog oscilloscope with a minimum
bandwidth of 1 GHz or a digital oscilloscope with a minimum sampling rate of 2 gigasamples per
second and a minimum bandwidth of 1 GHz. Each instrument shall have a 50 ohm input
impedance. A faster oscilloscope (larger bandwidth and/or higher sampling rate) may be
required to fully characterize the ESD waveform.
The coaxial target shall be a current-sensing transducer as specified by IEC 801-2 (1990), or
equivalent. The target is used to verify the ESD simulator waveform as defined in sections 2.3,
2.3.1, and 2.3.2.
Page 72 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
The ground plane is a common electrical reference point with dimensional requirements of a
2
1 mm minimum thickness and a 1 m minimum area. The ground plane is connected to earth
ground by a ground strap as short and as wide as possible; length ≤ 1 m, width ≥ 5 mm, and
inductance ≤ 2 µH.
2.2.3 Probe:
The probe used to verify the ESD simulator charging voltage, as defined in sections 2.3.2 and
2.4, shall be an electrometer probe with an input impedance ≥ 100 Gigohm.
ESD simulator calibration and qualification must be performed during initial acceptance testing
and whenever the simulator is serviced. A period of six (6) months is the maximum permissible
time between full qualification tests. The ESD simulator must meet the waveform parameter
requirements for all voltage levels as defined in Table 1, section 2.3.1, and section 2.3.2. If at
any time the waveforms do not meet the requirements of Table 1 and Figure 3, the testing shall
be halted until waveforms are in compliance.
Page 73 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
b. The coaxial target shall be located on and bonded to the center of the ground plane.
The target output shall be connected to the oscilloscope through a 50 ohm double-
shielded, high frequency, semi-rigid cable with length ≤ 1 meter. The cable shall not be
looped and shall be insulated from the ground plane.
c. The horizontal time base and vertical amplifier level of the oscilloscope shall be
configured in order to view the rise time of the ESD waveform. The horizontal sweep
shall be set to single event trigger.
d. The ESD simulator high voltage ground shall be directly connected to the ground plane
by a grounding strap with length ≤ 1 meter and an inductance ≤ 2 µH. The ESD
simulator shall be set up and operated according to its instruction manual.
Coaxial Target
50 ohms
(distributed)
ESD Simulator 20 dB (10X)
Attenuator
2 ohms (if applicable) 50 ohms
(distributed) Scope Input
a. To calibrate the display voltage of the ESD simulator, adjust the simulator voltage to the
desired level and polarity. With the electrometer in direct contact with the discharge tip
(see Figure 1), verify the voltage setting at levels of ± 500 V, ± 1 kV, ± 2 kV, ± 4 kV, ± 8
kV, ± 12 kV, ± 16 kV, and ± 25 kV. The electrometer reading shall be within ± 10% for
voltages from 200 V to ≤ 25 kV.
b. For Direct Contact Discharge Qualification, discharge to the coaxial target at each
voltage level and polarity shown in Table 1. Record the rise time and first peak current
values and verify the parameters meet the requirements of Table 1. Figure 3 illustrates
a typical discharge waveform to a coaxial target. The simulator must meet the
requirements of Table 1 and Figure 3 for five (5) consecutive waveforms at all voltage
levels.
Page 74 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
c. For Air Discharge qualification, the ESD simulator shall be placed a distance of ≥ 15 mm
from the coaxial target sphere. The ESD simulator, with the air discharge probe
attached, shall be held perpendicular (± 15°) to the target. From this position, the
simulator air discharge probe shall be slowly (≤ 5 mm/second) moved towards the target
until a single discharge occurs. Only single event discharge waveforms shall be
acceptable. Test voltages for the air discharge are ± 12 kV, ± 16 kV, and ± 25 kV.
Figure 3 illustrates a typical discharge waveform to a coaxial target. The slow approach
method specified above minimizes multiple discharges, discharges at lower voltage
levels, and ringing in the measurement equipment.
The performance of the simulator can be dramatically degraded by parasitics in the discharge
path. Therefore, to ensure proper simulation and repeatable ESD results, ESD simulator charge
verification shall be performed before each daily use. With the electrometer in direct contact
with the discharge tip (see Figure 1), verify the voltage setting at levels of ± 500 V, ± 1 kV, ± 2
kV, ± 4 kV, ± 8 kV, ± 12 kV, ± 16 kV, and ± 25 kV. The electrometer reading shall be within ±
10% for voltages from 200 V to ≤ 25 kV. If at any time the simulator charge does not meet the
requirements of Table 1, the testing shall be halted until the simulator is in compliance and all
ESD testing performed since the last passing charge verification shall be considered invalid.
Table 1: Direct Contact and Air Discharge ESD waveform parameter requirements
Page 75 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Ip
90%
10%
t
tr Time (ns)
Figure 3: Typical Direct Contact and Air Discharge PASSIVE COMPONENT HBM ESD discharge
waveform to a coaxial target
Each pair of pins and/or terminals and all combinations of pin and/or terminal pairs for each component
shall be subjected to one (1) pulse at each stress voltage polarity following the ESD levels stated in
Figure 4. Any pin and/or terminal not under test shall be in an electrically open (floating) state. A
sufficient number of ESD levels must be tested to either: a) demonstrate the component can pass a 25
kV Air Discharge exposure, or b) determine the pass/fail transition region between two (2) consecutive
ESD test levels. If an expected failure level cannot be estimated, the test flow diagram of Figure 4 may
be used to minimize the amount of testing required.
Page 76 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Each component shall be subjected to ESD pulses at 22C ± 5C. For all Air Discharge testing,
the relative humidity shall be 30% to 60%.
3.4 Measurements:
Prior to ESD testing, complete parametric testing (initial electrical verification) shall be
performed on all sample groups and all components in each sample group per applicable user
device specification at room temperature followed by hot temperature, unless specified otherwise
in the user device specification. If using an allowable parametric shift as a failure criterion, a
data log of each component shall be made listing the applicable parameter measurement values.
The data log will be compared to the parameters measured during final electrical test
verification testing to determine the failure criteria of section 4.
a. Ensure that the daily ESD simulator charge verification procedure (section 2.4) has been
performed before applying discharges to the DUT.
b. The ESD simulator high voltage ground shall be directly connected to the ground plane
by a grounding strap with a length ≤ 1 meter and an inductance ≤ 2 µH.
c. All DUTs are considered sensitive to ESD until proven otherwise and shall be handled
accordingly (reference internal procedures for proper handling of ESD sensitive
components).
d. The DUT must pass complete parametric testing (initial electrical verification) as defined
in section 3.4 prior to any application of ESD stress voltage levels.
a. The ESD simulator shall be placed in direct contact with each PUT specified in section
3.2.
b. Each PUT within a sample group shall be tested at a stress voltage level specified in the
test flow diagram of Figure 4 using the Direct Contact discharge probe. Two (2)
discharges shall be applied to each PUT within a sample group and at each stress
voltage level, one (1) with a positive polarity and one (1) with a negative polarity.
c. After each discharge to the PUT, residual charge remaining on the DUT shall be
dissipated by briefly connecting a one (1) megohm resistor between the PUT discharge
location and/or ground point of the DUT and the ground of the test setup.
d. Repeat the procedure for all components within the sample group.
e. Using the next sample group, select another direct contact stress voltage level and
repeat the above procedure until all sample groups have been tested at a specified
voltage level. It is permitted to use the same sample group for the next stress voltage
level if all components in the sample group meet the acceptance criteria requirements
specified in section 5 after exposure to a specified voltage level.
Page 77 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
f. Submit the components for complete parametric testing (final electrical verification) per
the user device specification at room temperature followed by hot temperature, unless
specified otherwise in the user device specification, and determine whether the
components meet the acceptance criteria requirements specified in section 5. It is
permitted to perform the parametric testing (final electrical verification) per user device
specification after all sample groups have been tested.
a. Using a new sample group, each PUT specified in section 3.2 shall be tested at an air
discharge stress voltage level specified in the test flow diagram of Figure 4 using the Air
Discharge probe. It is permitted to use the same sample group for the next stress
voltage level if all components in the sample group meet the acceptance criteria
requirements specified in section 5 after exposure to a specified voltage level.
b. The ESD simulator shall be placed ≥ 15 mm away from the PUT. The simulator, with
the Air Discharge probe, shall be held perpendicular to the PUT discharge location. The
probe shall be slowly moved towards the PUT (e.g., ≤ 5 mm/second) until a single
discharge is obtained.
c. If no discharge occurs, continue moving the probe towards the DUT until the simulator
discharge probe contacts the PUT discharge location. If the simulator makes contact
with the PUT discharge location and discharge occurs, discontinue testing at the stress
voltage level and location. A test board with closely spaced lead wires or metal runners
may prevent discharging to an intended PUT and result in an arcing phenomenon.
When this situation occurs, multiple test boards with a reduced number of lead wires or
metal runners shall be used.
d. Two (2) discharges shall be applied to each PUT within a sample group at the air
discharge stress voltage level, one (1) with a positive polarity and one (1) with a negative
polarity.
e. After each discharge to the PUT, residual charge remaining on the DUT shall be
dissipated by briefly connecting a one (1) megohm resistor between the PUT discharge
location and/or ground point of the DUT and the ground of the test setup.
f. Repeat the procedure for all components within the sample group.
g. Using the next sample group, select another air discharge stress voltage level and
repeat the above procedure until all sample groups have been tested at a specific
voltage level. It is permitted to use the same sample group for the next stress voltage
level if all components in the sample group meet the acceptance criteria requirements
specified in section 5 after exposure to a specified voltage level.
h. Submit the components for complete parametric testing (final electrical verification) per
the user device specification at room temperature followed by hot temperature, unless
specified otherwise in the user device specification, and determine whether the
components meet the acceptance criteria requirements specified in section 5. It is
permitted to perform the parametric testing (final electrical verification) per user device
specification after all sample groups have been tested.
Page 78 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
A component will be defined as a failure if, after exposure to ESD pulses, the component fails
any of the following criteria:
1. The component exceeds the allowable shift value. Specific parameters and allowable
shift values shall be defined in the applicable user device specification. During initial
parametric testing, a data log shall be made for each component listing the applicable
parameter measurement values. The data log will be compared to the parameters
measured during final parametric testing to determine the shift value. Components
exceeding the allowable shift value will be defined as a failure.
2. The component no longer meets the user device specification requirements. Complete
parametric testing (initial and final electrical verification) shall be performed per
applicable user device specification.
A component passes a voltage level if all components stressed at that voltage level pass. All
the samples used must meet the measurement requirements specified in section 3 and the
failure criteria requirements specified in section 4. Using the classification levels specified in
Table 2, classify the components according to the highest ESD voltage level survived during
ESD testing. The supplier shall define the ESD withstanding voltage for each component.
Page 79 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
6 ≥ 25,000 V (AD)
Page 80 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
6 kV
Direct Contact
FAIL PASS
2 kV 12 kV
Direct Contact Air Discharge
1 kV 4 kV 8 kV 16 kV
Direct Contact Direct Contact Direct Contact Air Discharge
500 V 1 kV 2 kV 4 kV 6 kV 8 kV 12 kV 25 kV
Direct Contact DC DC DC DC DC AD Air Discharge
Note 1: Classify the components according to the highest ESD voltage level survived during
ESD testing.
Page 81 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Revision History
Rev # Date of change Brief summary listing affected paragraphs
Page 82 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
ATTACHMENT 3
Page 83 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
METHOD - 003
PASSIVE COMPONENT
SURFACE MOUNTED CERAMIC CAPACITORS
BEAM LOAD (BREAK STRENGTH) TEST
1.0 SCOPE
1.1 DESCRIPTION:
This specification establishes the procedure and criteria for evaluating break strength.
Not Applicable
2.0 EQUIPMENT:
The apparatus required for testing shall be equivalent to the fixture shown in Figure 1.
The total number of components and lots to be tested are listed in Table 1 of AEC-Q200
specification.
Place the part in the beam load fixture. Apply a force until the part breaks or the minimum acceptable
force level required in the user specification(s) is attained.
3.3 Measurement:
Prior to beam load testing, complete the external visual (TST NO. 9) test. Record the force level
at which the part breaks to conclude the test.
Page 84 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Breaking strength
Tested with the fixture described below
During (if applicable) and after subjection to test, part rupture prior to any minimum user force
requirement shall be considered a failure.
Page 85 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Revision History
Rev # Date of change Brief summary listing affected paragraphs
Page 86 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
ATTACHMENT 4
Page 87 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
METHOD 004
PASSIVE COMPONENT
MEASUREMENT METHODS FOR
RESETTABLE FUSES
1.0 SCOPE
1.1 Description:
This method covers the test and measurement methods for resettable fuses based on polymeric
materials with positive temperature coefficient of resistance. The purpose of this specification is
to provide users of such components means to compare polymeric positive temperature
coefficient (PPTC) based resettable fuses against an established standard performance
requirements tested in accordance with an established test method. This method provides
supplemental information required to perform tests described in Table 14 of AEC-Q200.
1.2.1 Absolute Maximum Resistance, Amax: Maximum functional resistance of devices before and
after stress tests.
1.2.2. Absolute Minimum Resistance, Ramin: Minimum functional resistance of devices before and after
stress tests.
1.2.3 Core Material (Chip): A singulated sub-component of resettable fuse material that contains
conductive polymer and two electrodes that may be coated with solder.
1.2.4 Electrical Current Type: Unless otherwise specified, direct current power source shall be used.
1.2.5 Lot: Unless otherwise specified, a lot shall consist of devices manufactured to the same part
drawing number, assembled at the same location using the same production techniques,
materials, controls and design.
1.2.6 Maximum Hold Current, Ihold: The maximum current that any device of a given product
designation (part number) is guaranteed to hold without tripping, at specified temperature
conditions, and under specified circuit and/or source conditions.
1.2.7 Maximum Hold Current at Temperature, Ihold@T: Maximum hold current at the specified ambient
temperature as specified in User Specification.
1.2.8 Maximum Operating Voltage, Vmax: The maximum voltage a resettable fuse is designed to
tolerate as specified on device User Specifications.
1.2.9 Maximum Resistance, Rmax: The maximum resistance of a device that has not been tripped in
as-shipped condition and measured at room temperature.
1.2.10 Maximum Short Circuit Current, Iscmax: The maximum current used to perform short circuit
current durability test based on device operating parameters specified on the user
specification.
Page 88 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
1.2.11 Minimum Resistance, Rmin: The lowest specified resistance of a device that has not been tripped
in as-shipped condition and measured at room temperature.
1.2.12 Room Temperature: Unless otherwise defined, the temperature range of 25±5ºC is defined as
the room temperature.
1.2.13 Passive Resistance: Resistance of a device measured with no power (excluding measurement
instrument supplied power) applied to the device.
1.2.14 Steady State: A change of less than 1% in the power dissipation over a one minute period.
1.2.15 Still Air Environment (Non-forced Air Environment): An environment where the only air
movement is from natural convection due to heating or cooling of ambient air.
1.2.16 Time-to-Trip, TtT: Time-to-trip is defined as an elapsed time from the application of a specific
amount of current to a device-under-test at a specific ambient temperature specified in the
user specification to the point where the device-under-test reaches the tripped state.
1.2.17 Trip Current, Itrip: The minimum current guaranteed to trip any device of a given product
designation in a specified time, at specified temperature conditions, and under specified circuit
and/or source conditions.
1.2.18 Tripped Power Dissipation, Pd: Power dissipation is the product of the current flowing through a
device in the tripped state and the voltage across the device.
1.2.19 Tripped State: A device is in the tripped state when the voltage across the device-under-test rises to
80% of the open circuit source voltage, or the resistance of the device increases by a factor of 40 times
or more of the maximum specified resistance at the test environment temperature.
2.1.1.1 Leaded: Where applicable and unless otherwise specified, devices shall be mounted for
electrical testing to the test apparatus via a pair of spring loaded clips. Leaded devices with
formed leads shall be clipped within 5 mm from the base of the form away from the device body.
Leaded devices with non-formed leads shall be clipped at 5 to 10 mm from the bottom of the
body of the part.
2.1.1.2 SMD: Where applicable and unless otherwise specified, devices shall be mounted for electrical
testing on printed circuit boards where the power dissipation of the mounted device is consistent
with the typical power dissipation value found in User Specification. Devices shall be reflowed
on to test boards using a reflow oven, or equivalent, and an appropriate reflow temperature-time
profile. Devices shall be left at room temperature for a minimum of 24 hours prior to starting
pre-stress tests.
2.2 Test Power Source: Unless otherwise specified, the standard open circuit test voltage shall be at
the maximum operating voltage on User Specification. Unless otherwise required, the power
source shall be capable of delivering the current required to perform the test. Whenever
required, current delivered to the device shall be determined based on initial resistance at room
Page 89 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
temperature. This may be achieved by measuring the initial resistance at room temperature
immediately preceding the test and calculating the necessary load resistance to deliver the
current required by the specification.
2.3.1 Standard Stress Test Conditions: Unless otherwise specified herein, all stress tests shall be
performed at the standard room condition. The standard room condition shall be defined as the
temperature of 25 ± 5 °C with uncontrolled ambient air pressure and relative humidity.
Whenever these conditions must be closely controlled in order to obtain reproducible results, for
referee purposes, a temperature of 25 ± 3 °C, at uncontrolled ambient air pressure and relative
humidity shall be used.
2.3.2 Standard Stress Test Tolerances: Unless otherwise specified, the tolerances for stress
conditions shall be as follows:
Voltage: ± 2% Weight: ± 2%
Current: ± 2% Humidity: ± 5%
Temperature: ± 5°C Length: ± 5%
Time: +10% -0%
2.3.3 Pre- and Post-Stress Test Conditions: Unless otherwise specified herein, all pre- and post-stress
test evaluation measurements shall be performed at the minimum, room, and maximum rated
temperatures. At the start of this test, the test chamber shall be controlled to test temperature ±
3 °C, at uncontrolled ambient air pressure and relative humidity. The temperature controller
shall be capable of controlling the test chamber temperature to set temperature ± 2 °C.
3.2.1 Passive Resistance at Temperature: Devices shall be tested in accordance with AEC-Q200-004-
001.
3.2.3 Hold Current at Temperature: Devices shall be tested in accordance with AEC-Q200-004-003
for hold current.
3.2.4 Sequence of Testing: Unless otherwise specified, the electrical performance verification tests
shall be performed in the following order and state of the device:
Passive resistance at temperature: “As is” condition following any stress tests. For devices that
require soldering for mounting on a test apparatus, devices shall be in room temperature and
condition storage for at least 24 hours after-soldering prior to testing.
Time-to-trip at temperature: “As is” condition after passive resistance test.
Hold current at temperature: Test shall be performed after a minimum of 1 hour from the
conclusion of a trip event such as time-to-trip test. The starting of hold current test shall not
exceed three hours from the conclusion of the trip event.
3.2.5 Test Environment: Electrical performance verification tests shall be performed at the minimum,
room, and maximum rated temperatures. The devices shall be tested, unless otherwise
specified, in a non-forced air environment. The test chamber temperature shall be monitored
Page 90 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
and controlled at a location that reasonably represents the general test chamber temperature and
result in the ability to control the chamber temperature as required. Test samples shall be
divided into three equal groups except when the samples are not equally divisible, the remaining
one or two devices shall be included in the room temperature test group. The groups that are
selected to be in a certain temperature group shall remain in the same temperature group for
pre- and post-stress tests.
3.3.1 Operational Life: Parts shall be tested per MIL-STD-202 Method 108 with the following details:
Distance of temperature measurement from specimen: 10.16 cm minimum
Still-air Requirement: None - Circulation oven permitted provided that there is no direct
impingement of air flow on devices under test.
Test Temperatures: At 85C (125C for 125 C parts)
Operating Conditions: Apply Ihold@T in constant current mode with power on for 15 seconds and
off for 15 seconds. Devices-under-test may be connected in series for simplification of the
power delivery system.
3.3.2 Terminal Strength (Leaded only): Parts shall be tested per MIL-STD-202 Method 211 with the
following details:
Test Condition A:
Method of Holding the device: Device-under-test (DUT) shall be held using a strip of
fiberglass loaded Teflon sheet that is bent around DUT in between the pant legs in a “U”
shape. Two free ends of the strip shall be held in the jaw or vice. The load shall be applied
to one lead at a time in the manner prescribed in MIL-STD-202 Method 211. The width of
the strip shall be slightly less than the distance between the pant legs. The strip shall be
secured to DUT by means of adhesive tape such as fiber-glass tape to prevent slippage.
Test Condition C:
Post-stress visual examination: Prior to post-stress electrical tests examine the bend area
for cracks or breakage of wire lead. with a microscope with magnification of no greater than
10.
Apply the maximum short circuit current (ISCMAX ) specified in the user specification through the
device under test for 5 to 10 seconds. Then remove the current for a minimum of 2 minutes.
Repeat for the number of cycles specified in the user specification, where VPOWER SUPPLY = ISCMAX
X RTEST SYSTEM. VPOWER SUPPLY, however, shall not exceed rated voltage for the device, and to set
ISCMAX, a shorting buss bar shall be used across the DUT mounting clips.
The device shall be functional after the test as verified per post-stress tests that include visual
inspection, resistance, time-to-trip verification, and hold current verification.
Apply a minimum of 6 times the rated hold current ( IHOLD ) specified in the user specification
through the device under test for 5 to 7 minutes and then remove for a minimum of 10 minutes.
Repeat for the number of cycles specified in the user specification. The device shall be
Page 91 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
functional after the test as verified per post-stress tests that include visual inspection, resistance,
time-to-trip verification, and hold current verification.
Page 92 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
Use the devices that were subjected to the fault durability test. Apply enough current, long
enough to
trip the device (current shall be a minimum of 6 times IHOLD specified in the user specification).
Hold
in the tripped condition for 5 to 10 seconds and then turn power off for a minimum of minute.
Repeat
for the number of cycles specified in the user specification.
After stressing, examine for burnt devices and measure resistance. The device shall exhibit
PTC of resistance behavior or shall have a resistance value that is high enough to limit the
current to the hold current (IHOLD) specified for the device at the rated voltage specified in the
user specification.
Apply 26 volts across RL in series with the device under test. Monitor the voltage across RL with
an oscilloscope or equivalent. Apply voltage for 1minute ± 3 seconds then turn off for a
minimum of 2 minutes. Apply and remove voltage 3 times. RL ≤ Vmax of device / Ihold. Resistance
due to wire and other electrical connections and the source impedance of the power supply shall
be included in the calculation of RL
The device shall be functional after the test as verified per post-stress tests that include visual
inspection, resistance, time-to-trip verification, and hold current verification.
.
3.3.7 Load Dump Endurance: Devices shall be tested in accordance with ISO7635-1 using Test Pulse
number 5.
Apply ISO 7635-1 load dump voltage VS across RL and the device under test . Monitor the
voltage across RL with an oscilloscope or equivalent. The pulses shall be applied every 90 ± 30
seconds for a total of 10 pulses. RL ≤ Vmax of device / Ihold. Resistance due to wire and other
electrical connections and the source impedance of the power supply shall be included in the
calculation of RL
The device shall be functional after the test as verified per post-stress tests that include visual
inspection, resistance, time-to-trip verification, and hold current verification.
Test Parameters:
Vs: The test pulse voltage shall be the rated device load dump voltage as defined
in User Specification.
Ri: In accordance with the table below.
UA: 13.5 ± 0.5 V
td: In accordance with the table below.
t r: 5-10 ms
Vs (V) Ri ( ) td (ms)
26.5 0.50 40
46.5 1.67 160
66.5 2.83 280
86.5 4.00 400
Page 93 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
AEC-Q200-004-001
1.0 SCOPE
1.1 Purpose: This AEC-Q200-004-001 covers methods used to measure resistance of PTC
resettable devices while the devices are in the off state.
2.0 EQUIPMENT
3.0 PROCEDURE
3.1 Test Circuit, 2-Wire: The measuring instrument may be connected to the test device with any
suitable clip leads. This method shall be used to measure device resistance values of 20 ohms
or higher.
3.2 Test Circuit, 4-Wire: The measuring instrument is generally connected to the test device with
special Kelvin clip leads. If standard clip leads are used, the voltage leads must be the closer to
the body of the device, and the current leads further from the body of the device. This method
of resistance measurement shall be used to measure device resistance values of less than 20
ohms.
3.3 Device Mounting and Resistance Measurement Location: Resistance of devices shall be
measured at the connection point to the fixture as defined in Paragraph 2.1.1 of AEC-Q200-004.
3.4 Resistance Measurements for Devices Mounted with Heat: Initial resistance of the devices
that require heat for mounting onto test fixtures (e.g. soldering of SMD components) shall be the
value measured at least 24 hours from the time of the heating operation.
Page 94 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
AEC-Q200-004-002
1.0 SCOPE
1.1 Purpose: The purpose of this test is to verify that a test specimen will trip within a specified
length of time at a specified current.
2.0 EQUIPMENT
2.1 Power Supply: A power source capable of supplying the trip current specified in the user
specification, at the voltage specified in the user specification. The source voltage must be
controlled to ± 2%. The load resistor controls the source current.
2.2 Load Resistor: A load resistor to adjust the current through the test specimen to ± 2% of the
trip current specified in the user specification, when the power source is set for the maximum
operating voltage specified in the user specification.
2.3 Parametric Measurement Instruments: A system for measuring either the voltage across the
test specimen, or the current through it (or both), as a function of time. The time resolution of
the system needs to be 100 milliseconds or better, unless otherwise specified in the user
specification. The voltage or current needs to be determined to be an accuracy of ± 2%. Digital
equipment is suggested, for ease in storing and transferring information. Suitable systems
include digital oscilloscopes, A/D converters, and computer-controlled multimeters.
3.0 PROCEDURES
3.1 Device Mounting: Test samples shall be mounted in accordance with Paragraph 2.1.1 of AEC-
Q200-004. The devices shall be tested individually or multiple devices in parallel. When
multiple devices are connected in parallel, the current through each device shall be controlled
and monitored separately. In addition, time-to-trip measurement shall be measured individually
Page 95 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
3.2 Resistance: Resistance of test samples shall be measured prior to the time-to-trip test and one
hour after the conclusion of the test in accordance with AEC-Q200-004-001.
3.3 Non-Forced Air Ambient: The time-to-trip of PTC resettable devices may be influenced
substantially by air flow. As such, there shall be no air circulation around the test specimen
during the test, including air flow due to body motion. Naturally convective airflow due to heating
and cooling of the test specimen shall be allowed.
3.4 Test Temperature: The devices shall be tested at the temperature specified in this specification or User
Specification. The test specimens shall be allowed to equilibrate at the specified temperature for a
minimum of 5 minutes.
3.5 Test Current: The time-to-trip evaluation test current level shall be as specified in User
Specification. In cases where the test current is not specified, 5 times the Ihold@T shall be used.
3.6. Test Sequence: The time-to-trip test shall be performed after a resistance measurement. The device
shall not experience any trip event(s) after manufacturing, soldering, or stress testing, whichever is the
most recent event, prior to the time-to-trip test.
Page 96 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
AEC-Q200-004-003
1.0 SCOPE
1.1 Purpose: The purpose of this test is to verify that a test specimen will pass a specified current
without tripping.
2.0 EQUIPMENT
2.1 Power Supply: A power source capable of supplying the trip current specified in the user
specification, at the voltage specified in the user specification. The source voltage must be
controlled to ± 2%. The load resistor controls the source current.
2.2 Load Resistor: A load resistor to adjust the current through the test specimen to ± 1% of the
trip current specified in the user specification, when the power source is set for the maximum
operating voltage specified in the user specification.
2.3 Parametric Measurement Instruments: A system for measuring either the voltage across the
test specimen, or the current through it (or both), as a function of time. The voltage or current
needs to be determined to an accuracy of ± 1%. Digital equipment is suggested, for ease in
storing and transferring information. Suitable systems include digital oscilloscopes, A/D
converters, and computer-controlled multimeters.
2.4 Elapsed Time Measurement Device: Commonly used time measuring instrument capable of
timing the hold current test duration, e.g. stop watch.
3.0 PROCEDURES
3.1 Device Mounting: Test samples shall be mounted in accordance with Paragraph 2.1.1 of AEC-
Q200-004. The devices may be tested individually or in groups. If tested in a group, the devices
shall be connected in series.
Page 97 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
3.2 Resistance: Resistance of test samples shall be measured prior to the hold current test and one
hour after the conclusion of the test in accordance with AEC-Q200-004-001.
3.3 Non-Forced Air Ambient: The hold current capability of PTC resettable devices may be influenced
substantially by airflow. As such, there shall be no air circulation around the test specimen during the
test, including airflow due to body motion. Naturally convective airflow due to heating and cooling of the
test specimen shall be allowed.
3.4 Test Temperature: The devices shall be tested at the temperature specified in this specification
or User Specification. The test specimens shall be allowed to equilibrate at the specified
temperature for a minimum of 5 minutes.
3.5 Test Current: The hold current level shall be as specified in User Specification as Ihold@T.
3.6 Test Sequence: The hold current evaluation test shall be performed at least one hour, but not
more than three hours, after the most recent trip event. In most cases, this trip event will be a
time-to-trip evaluation test.
3.7 Test duration: The hold current as defined in accordance with User Specification shall be
applied to the test specimen for 15 minutes or more.
3.8 Pass/Fail Criteria: The samples that pass the hold current evaluation test shall be capable of
conducting specified Ihold@T for a minimum of 15 minutes.
Page 98 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
AEC-Q200-004-004
1.0 SCOPE
1.1 Purpose: The purpose of this test is to verify that a test specimen will trip at a specified current.
2.0 EQUIPMENT
2.1 Power Supply: A power source capable of supplying the trip current specified in the user
specification, at the voltage specified in the user specification. The source voltage must be
controlled to ± 2%.
2.2 Load Resistor: A load resistor to adjust the current through the test specimen to ± 2% of the
trip current specified in the user specification, when the power source is set for the maximum
operating voltage specified in the user specification.
2.3 Parametric Measurement Instruments: A system for measuring either the voltage across the
test specimen, or the current through it (or both). The voltage or current needs to be determined
to an accuracy of ± 2%. Digital equipment is suggested, for ease in storing and transferring
information. Suitable systems include digital oscilloscopes, A/D converters, and computer-
controlled multimeters.
2.4 Elapsed Time Measurement Device: Simple time measuring instrument capable of timing the
trip current test duration.
3.0 PROCEDURES
3.1 Device Mounting: Test samples shall be mounted in accordance with Paragraph 2.1.1 of AEC-
Q200-004 The devices shall be tested individually or connected to the power supply in parallel.
3.2 Resistance: Resistance of test samples shall be measured prior to the trip current test and one
hour after the conclusion of the test in accordance with AEC-Q200-004-001.
Page 99 of 111
AEC-Q200-REV C
June 17, 2005
Automotive Electronics Council
Component Technical Committee
3.3 Non-Forced Air Ambient: The trip current capability of PTC resettable devices may be
influenced substantially by airflow. As such, there shall be no air circulation around the test
specimen during the test, including airflow due to body motion. Naturally convective airflow due
to heating and cooling of the test specimen shall be allowed.
3.4 Test Temperature: The devices shall be tested at the temperature specified in this specification or User
Specification. The test specimens shall be allowed to equilibrate at the specified temperature for
minimum of 5 minutes.
3.5 Test Current: The trip current level shall be as specified in User Specification as Itrip@T.
3.6 Test Sequence: The trip current evaluation test shall be performed on devices that have not
been tripped. If a heating process, such as soldering, is necessary to perform tests on a test
fixture, the device shall be conditioned at the standard room condition for at least 24 hours prior
to the testing of the trip current.
3.7 Test duration: The trip current as defined in accordance with User Specification shall be
applied to the test specimen for 15 minutes or until the device trips, whichever occurs first.
3.8 Pass/Fail Criteria: The samples that pass the trip current evaluation test shall trip at the specified Itrip@T
in 15 minutes or less.
AEC-Q200-004-005
1.0 SCOPE
1.1 Description: The purpose of this test is to determine the amount of power dissipated by a
device in a standard environment after it has stabilized in the tripped state.
2.0 EQUIPMENT
2.1 Power Supply: A power source capable of supplying the trip current specified in the user
specification, at the voltage specified in the user specification. The source may be either ac or
dc, unless the type is specified in the user specification. The source voltage must be controlled
to ± 2%. The load resistor controls the source current.
2.2 Load Resistor: A load resistor to adjust the current through the test specimen to ± 2% of the
trip current specified in the user specification, when the power source is set for the maximum
operating voltage specified in the user specification.
2.3 Parametric Measurement Instruments: A system for measuring either the voltage across the
test specimen and the current through the device-under-test. The voltage or current needs to be
determined to an accuracy of ± 2%. Digital equipment is suggested, for ease in storing and
transferring information. Suitable systems include digital oscilloscopes, A/D converters, and
computer-controlled multimeters, or equivalent.
3.0 PROCEDURE
3.1 Device Mounting: Test samples shall be mounted in accordance with Paragraph 2.1.1 of AEC-
Q200-004. The devices may be connected to the power source in parallel.
3.2 Resistance: Resistance of test samples shall be measured prior to the power dissipation test
and one hour after the conclusion of the test in accordance with AEC-Q200-004-001.
3.3 Non-Forced Air Ambient: The power dissipation of PTC resettable devices may be influenced
substantially by airflow. As such, there shall be no air circulation around the test specimen
during the test, including airflow due to body motion. Naturally convective airflow due to heating
and cooling of the test specimen shall be allowed.
Revision History
Rev # Date of change Brief summary listing affected paragraphs
Attachment 5
PASSIVE COMPONENT
SURFACE MOUNTED DEVICES
METHOD - 005
PASSIVE COMPONENT
Board Flex / Terminal Bond Strength Test
1.0 SCOPE
1.1 DESCRIPTION:
This specification establishes the procedure and criteria for evaluating the Terminal Strength of a
Surface Mount Component when mounted on a PCB during a Board Flex.
Not Applicable
2.0 EQUIPMENT:
The apparatus required for testing shall be equivalent to the fixture shown in Figure 1.
The total number of components and lots to be tested are listed in Table 1 of AEC-Q200
specification.
1. Part mounted on an FR4 board provided by the Supplier for the part being tested with the
following requirements:
3. Part mounted on a 100mm X 40mm FR4 PCB board, which is 1.6mm ± 0.2 mm thick and has a
Layer-thickness 35 µm ± 10 µm. Part should be mounted using the following Soldering Reflow
profile:
4. Place the 100mm X 40mm board into a fixture similar to the one shown in Figure 1 with the
component facing down. The apparatus shall consist of mechanical means to apply a force
which will bend the board (D) x = 2 mm minimum (or as defined in the customer specification or
Q200). The duration of the applied forces shall be 60 (+ 5) Sec. The force is to be applied only
once to the board.
3.3 Measurement:
Prior to beam load testing, complete the external Visual test in Q200. A test monitor shall be
used to detect when a part cracks or a termination failure occurs. (example: Megohmeter
attached with leads during the time the force is being applied to a Ceramic Capacitor. A crack
would cause a deflection of the needle towards zero.)
3.4 Failure:
A failure is when a part cracks or causes a change in the parametric being monitored.
Revision History
Attachment 6
METHOD - 006
PASSIVE COMPONENT
Terminal Strength (SMD) / Shear Stress Test
1.0 SCOPE:
The purpose of this test is to verify that the component terminations can withstand axial stresses
that are likely to be applied during normal manufacturing and handling of a finished printed
circuit board (PCB) assembly.
1.1 DESCRIPTION:
This test is designed to evaluate the strength of the solder bond between terminations/leads of a
surface mounted device and a specified copper pattern on glass epoxy circuit board.
None.
2.0 EQUIPMENT:
Unless otherwise specified, the SMD shall be tested while mounted onto a .062 inch thick FR-4
PCB using 1 ounce of Copper. The Supplier shall use the preferred pad layout for the device
being tested. The Supplier shall provide parts placed and reflowed on the test coupon and
provided as part of the qualification package. (See Figure 1 below)
See Figure 1
With the component mounted on a PCB obtained from the Supplier with the device to be tested,
apply a 17.7 N (1.8 Kg) force to the side of a device being tested. This force shall be applied for
60 +1 seconds. Also the force shall be applied gradually as not to apply a shock to the
component being tested. (See Figure 1)
Figure 1
Magnification of 20X or greater may be employed for inspection of the mechanical integrity of
the device body, terminals and body/terminal junction. Before, during and after the test, the
device shall comply with all electrical requirements stated in this specification.
The total number of components and lots to be tested is listed in Table 1 of AEC-Q200 specification.
Visual and Electrical characterization of devices are to be performed at room temperature per
device specification.
The failure criteria are governed by not meeting the device specification, along with evidence of
cracking or part being sheared off from its pad.
Revision History
Attachment 7
METHOD - 007
PASSIVE COMPONENT
VOLTAGE SURGE
TEST
1.0 SCOPE:
1.1 DESCRIPTION:
The purpose of this specification is to assure a device will withstand voltage surges at the surge
voltage rating of the device's specification.
Not Applicable
2.0 EQUIPMENT:
The total number of components and lots to be tested are listed in Table 1 of AEC-Q200 specification.
Subject capacitor under test, CDUT, to the voltage waveform in Figure 2. The charge and
discharge time constants, ratio of surge voltage to rated voltage, number of test cycles, duration
of charging and discharge periods, time between cycles, and temperature (if different than 25+/-
5C) shall be specified in the device specification.
Revision History