SR 12615

This standard establishes efficiency classes and performance specifications for three-phase AC line-operated motors rated from 0.12 kW to 1000 kW. It covers motors with 2, 4, 6, or 8 poles, rated voltages up to 1000V at 50Hz, and frame sizes from 56 to 315 according to IS 1231. The standard applies to motors that operate continuously at rated power within specified insulation temperature classes, between -20°C and +60°C, and up to 4000m altitude.

Uploaded by

Aravindh Nagaraj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
115 views1 page

SR 12615

This standard establishes efficiency classes and performance specifications for three-phase AC line-operated motors rated from 0.12 kW to 1000 kW. It covers motors with 2, 4, 6, or 8 poles, rated voltages up to 1000V at 50Hz, and frame sizes from 56 to 315 according to IS 1231. The standard applies to motors that operate continuously at rated power within specified insulation temperature classes, between -20°C and +60°C, and up to 4000m altitude.

Uploaded by

Aravindh Nagaraj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SYNOPSIS

DOC. ETD 15 (11575)

IS and Title:

LINE OPERATED THREE PHASE AC MOTORS (IE


IS 12615: 2018 CODE) “EFFICIENCY CLASSES AND PERFORMANCE
SPECIFICATION”

a) SCOPE:

This standard covers the efficiency classes & performance specifications of single-speed
line operated AC motors that are rated according to IS 15999 (Part 1)/IEC 60034-1, rated
for operation on a sinusoidal voltage supply and :
a) have a rated power from 0.12 kW to 1 000 kW;
b) have 2, 4, 6 or 8 poles;
c) have a rated voltage Un up to 1 000 V with a rated frequency of 50 Hz;
d) frame size from 56 up to and including 315 M having Frame to output co-relation as
specified in Table 3 of IS 1231;
e) frame size 315L with dimensions as per IS 1231 and having output rating as declared
by motor manufacturer;
f) frame size 355 and above, with dimensions & output ratings as declared by motor
manufacturer but conforming to IS 8223;
g) are capable of continuous operation at their rated power with a winding temperature
rise within the specified insulation temperature class;
h) are marked with any ambient temperature within the range of -20°C to +60°C;
i) are marked with an altitude up to 4000 m above sea level;
j) This standard covers motors with or without service factor;
k) Most motors covered by this standard are primarily rated for duty type S1 (continuous
duty). Motors rated for duty cycles S2 and above with an equivalent S1 duty are also
covered. These motors must also be marked with the equivalent S1 duty output and
its corresponding IE class. Declaration Value of S1 duty output value may be as per
mutual agreement between motor manufacturer and customer.
l) Motors with output power rating higher than as specified in table 3 of IS 1231 for a
given frame, must meet the efficiency class corresponding to that power rating.

b) Salient features of content:

c) Types/Grades/Classes, if any covered in the standard: N/A

d) Disclaimer (to be automatically provided by the program / software)