ASME VIII Flange Calculation
ASME VIII Flange Calculation
ASME VIII Flange Calculation
Table of contents
Table of contents .....................................................................................................................................................1
Comparison Form for equations ..............................................................................................................................2
Example E4.16.1 - Integral Type ..........................................................................................................................3
E 4.16.1 Bolted flanges ASME BPVC VIII DIVISION 1 APP. 2, 2015 Edition.........................................................5
Example E4.16.2 - Loose Type ...............................................................................................................................8
E 4.16.2 Bolted flanges ASME BPVC VIII DIVISION 1 APP. 2, 2015 Edition.........................................................9
Appendix: Material documentation ..........................................................................................................................9
Layout
Comparison
Form for equations
Equation form
Comment
Results for example E4.3.7-8 acc. ASME and Lauterbach Verfahrenstechnik GmbH (LV)
The LV-program uses formulas for Bolted flanges acc. VIII-1, App.2.
Equations Value
Conversion factor mm2in = 0.03937 0.03937
. N2lbf = 0.22481 0.2248
'Results Ex. E4.16.1 LV and ASME 0
Required load W acc. LV W1 = #23(1)*N2lbf 237101
Required load W ASME W1Asme = 237626.3 237626
Difference in % Diff1 = (W1-W1Asme)/W1Asme*100 -0.2211
0
0
'Results Ex. E4.16.2 LV and ASME 0
Required load W acc. LV W2 = #23(2)*N2lbf 383049
Required load W ASME W2Asme = 387702.5 387703
Difference in % Diff2 = (W2-W2Asme)/W2Asme*100 -1.2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
'Maximum difference between LV and ASME 0
Dmax = Max(|Diff1|;|Diff2|) 1.2
General Data:
Cylinder Material = SA-516, Grade 70
Design Conditions = 135 psig @650°F
Allowable Stress at Design Temperature = 18800 psi
Allowable Stress at Ambient Temperature = 20000 psi
Corrosion Allowance = 0.125 in
Flange Data:
Material = SA-105
Allowable Stress at Design Temperature = 17800 psi
Allowable Stress at Ambient Temperature = 20000 psi
Modulus of Elasticity at Design Temperature = 26.0E + 06 psi
Modulus of Elasticity at Ambient Temperature = 29.4E +06 psi
Bolt Data:
Material = SA-193, Grade B7
Allowable Stress at Design Temperature = 25000 psi
Allowable Stress at Ambient Temperature = 25000 psi
Diameter = 0.75 in
Number of Bolts = 44
Root area = 2
0.302 in
Gasket Data:
Material = Flat Metal Jacketed
(Iron/Soft Steel)
Gasket Factor = 3.75
Seating Stress = 7600 psi
Inside Diameter = 29.0 in
Outside Diameter = 30.0 in
Design rules for bolted flange connections with ring type gaskets are provided in Vlll-1 Mandatory
Appendix 2. The rules in this paragraph are the same as those provided in Vlll-2, paragraph 4.16.
However, there are differences to be noted, including; a step-by-step design procedure, nomenclature
with regard to operating and gasket seating bolt loads, the inclusion of a flange moment due to
externally applied axial forces and bending moment, and minor differences in bolt pacing criteria.
Therefore, while the example problem will be presented for use with Vlll-1, Appendix 2, references
to Vlll-2 paragraphs will be provided, as applicable.
Establish the design conditions and gasket reaction diameter, (VIII-2, paragraph 4.16.6).
E 4.16.1
Bolted flanges ASME BPVC VIII DIVISION 1 APP. 2, 2015 Edition
Integral Type Flange
Design data
Design pressure PD 135 psi = pD 135 psi
Hydrostatic head DP 0 psi = Dp 0 psi
Calculation pressure P0 135 psi = p0 135 psi
Calculation temperature T0 650 °F
Flange
Material K03504-SA-105--Class:-Size:
Allowable operating stress Sfb 17811 psi
Allowable installation stress Sfa 20015 psi
Corrosion allowance c2 0 in
Modulus of elasticity at operation ET 2.591e+7 psi
Modulus of elasticity at test (20°C) E20 2.915e+7 psi
Gasket
Gasket diameter G 29.5 in
Effective gasket width [Table:2.5.2] b 0.2031 in
Gasket factor [Table:2.5.1] m 3.75
Gasket seating load [Table:2.5.1] y 7600 psi
Bolts
Number n 44
Root diameter dK 0.62 in
Nominal diameter a 0.75 in
Material G41400-SA-193-B7-Class:-Size:<=64
Allowable operating stress Sb 24946 psi
Allowable installation stress Sa 24946 psi
Consider bolt factor BSC 2-6(7)? (N=No) Y (Y/N)
Remark
Auxiliary values
(Fig. 2-7.1)
(Fig. 2-7.1)
(Fig. 2-7.1)
(Fig. 2-7.1)
(Fig. 2-7.2)
(Fig. 2-7.3)
(Fig. 2-7.6)
Eq.(1)
Eq.(2)
Bolt pitch
(3)
For
(7)
Determine if the stresses in the ASME B16.5, Class 300, NPS 20 Slip-on Flange are with acceptable
limits, considering the following design conditions. The flange is of a loose type with hub and is
attached to a cylindrical shell with Category C fillet welds, see Vlll-1 Appendix 2, Figure 2-4 Sketch 3.
General Data
Cylinder Material = SA-516, Grade 70
Design Conditions = 450 psig@650°F
Allowable Stress at Design Temperature = 18800 psi
Allowable Stress at Ambient Temperature = 20000 psi
Corrosion Allowance = 0.0 in
Flange Data:
Material = SA-105
Allowable Stress at Design Temperature = 17800 psi
Allowable Stress at Ambient Temperature = 20000 psi
Modulus of Elasticity at Design Temperature = 26.0E + 06 psi
Modulus of Elasticity at Ambient Temperature = 29.4E +06 psi
Bolt Data:
Material = SA -193, Grade B7
Allowable Stress at Design Temperature = 25000 psi
Allowable Stress at Ambient Temperature = 25000 psi
Diameter = 1.25 in
Number of Bolts = 24
Root area = 0.929 in2
Gasket Data
Material = Kammprofile
Gasket Factor = 2.0
Seating Stress = 2500 psi
Inside Diameter = 20.875 in
Outside Diameter = 22.875 in
Design rules for bolted flange connections with ring type gaskets are provided in Vlll-1 Mandatory
Appendix 2. The rules in this paragraph are the same as those provided in Vlll-2, paragraph 4.16.
However, there are differences to be noted, including; a step-by-step design procedure, nomenclature
with regard to operating and gasket seating bolt loads, the inclusion of a flange moment due to
externally applied axial forces and bending moment, and minor differences in bolt spacing criteria.
Therefore, while the example problem will be presented for use with Vlll-1, Appendix 2, references to
Vlll-2 paragraphs will be provided, as applicable.
E 4.16.2
Bolted flanges ASME BPVC VIII DIVISION 1 APP. 2, 2015 Edition
Loose Type Flange With Full Neck
Design data
Design pressure PD 450 psi = pD 450 psi
Hydrostatic head DP 0 psi = Dp 0 psi
Calculation pressure P0 450 psi = p0 450 psi
Calculation temperature T0 650 °F
Flange
Material K03504-SA-105--Class:-Size:
Allowable operating stress Sfb 17811 psi
Allowable installation stress Sfa 20015 psi
Corrosion allowance c2 0 in
Modulus of elasticity at operation ET 2.591e+7 psi
Modulus of elasticity at test (20°C) E20 2.915e+7 psi
Gasket
Gasket diameter G 22.17 in
Effective gasket width [Table:2.5.2] b 0.3536 in
Gasket factor [Table:2.5.1] m 2
Gasket seating load [Table:2.5.1] y 2500 psi
Bolts
Number n 24
Root diameter dK 1.08 in
Nominal diameter a 1.25 in
Material G41400-SA-193-B7-Class:-Size:<=64
Allowable operating stress Sb 24946 psi
Allowable installation stress Sa 24946 psi
Consider bolt factor BSC 2-6(7)? (N=No) Y (Y/N)
Remark
Auxiliary values
(Fig. 2-7.1)
(Fig. 2-7.1)
(Fig. 2-7.1)
(Fig. 2-7.1)
(Fig. 2-7.4)
(Fig. 2-7.5)
Eq.(1)
Eq.(2)
Bolt pitch
(3)
For
(7)
Material specification:
Diam./·········|Tensile str.···|···············|ReH············|Rupture········|Rupture········
Thick.·········|Rm min·········|Rm max·········|···············|elong.·········|elong··········
<= mm··········|MPa············|MPa············|MPa············|längs %········|quer %·········
---------------+---------------+---------------+---------------+---------------+---------------
···············|···············|···············|···············|···············|···············
Diam./···|·········|·········|·········|·········|·········|·········|·········|·········
Thickn.··|50°C·····|100°C····|150°C····|200°C····|250°C····|300°C····|350°C····|400°C····
<= mm····|MPa······|MPa······|MPa······|MPa······|MPa······|MPa······|MPa······|MPa······
---------+---------+---------+---------+---------+---------+---------+---------+---------
·········|·········|138······|138······|138······|136······|129······|122······|101······
Diam./·····|···········|···········|···········|···········|···········|···········|···········
Thickn.····|450°C······|500°C······|550°C······|600°C······|650°C······|700°C······|800°C······
<= mm······|MPa········|MPa········|MPa········|MPa········|MPa········|MPa········|MPa········
-----------+-----------+-----------+-----------+-----------+-----------+-----------+-----------
···········|67.0·······|33.6·······|12.9·······|···········|···········|···········|···········
-75··|-200·|-125·|25···|100··|150··|200··|250··|300··|350··|400··|450··|500··|550··|600··
-----+-----+-----+-----+-----+-----+-----+-----+-----+-----+-----+-----+-----+-----+-----
207··|215··|211··|201··|197··|194··|191··|188··|183··|178··|170··|161··|149··|136··|121··
Density|100°C··|200°C··|300°C··|400°C··|500°C··|600°C··|700°C··|800°C··|Heat···|Heat···
(20 °C)|·······|·······|·······|·······|·······|·······|·······|·······|cond.··|capac.·
kg/dm³·|10E-6/K|10E-6/K|10E-6/K|10E-6/K|10E-6/K|10E-6/K|10E-6/K|10E-6/K|W/Km···|J/kgK··
-------+-------+-------+-------+-------+-------+-------+-------+-------+-------+-------
7,85···|12,1···|12,7···|13,3···|13,8···|14,4···|-······|-······|-······|·······|·······
—
Section 2: Schraube/AFL
Section 3: Schraube/AFL
Material specification:
Diam./·········|Tensile str.···|···············|ReH············|Rupture········|Rupture········
Thick.·········|Rm min·········|Rm max·········|···············|elong.·········|elong··········
<= mm··········|MPa············|MPa············|MPa············|längs %········|quer %·········
---------------+---------------+---------------+---------------+---------------+---------------
···············|···············|···············|···············|···············|···············
Diam./···|·········|·········|·········|·········|·········|·········|·········|·········
Thickn.··|50°C·····|100°C····|150°C····|200°C····|250°C····|300°C····|350°C····|400°C····
<= mm····|MPa······|MPa······|MPa······|MPa······|MPa······|MPa······|MPa······|MPa······
---------+---------+---------+---------+---------+---------+---------+---------+---------
·········|·········|172······|172······|172······|172······|172······|172······|162······
Diam./·····|···········|···········|···········|···········|···········|···········|···········
Thickn.····|450°C······|500°C······|550°C······|600°C······|650°C······|700°C······|800°C······
<= mm······|MPa········|MPa········|MPa········|MPa········|MPa········|MPa········|MPa········
-----------+-----------+-----------+-----------+-----------+-----------+-----------+-----------
···········|118········|68.8·······|18.9·······|···········|···········|···········|···········
650··|-75··|-200·|-125·|25···|100··|150··|200··|250··|300··|350··|400··|450··|500··|550··
-----+-----+-----+-----+-----+-----+-----+-----+-----+-----+-----+-----+-----+-----+-----
150··|210··|218··|213··|204··|200··|197··|193··|190··|186··|183··|179··|174··|169··|164··
600···············|700···············|··················|··················|··················
------------------+------------------+------------------+------------------+------------------
157···············|142···············|··················|··················|··················
—
Density|100°C··|200°C··|300°C··|400°C··|500°C··|600°C··|700°C··|800°C··|Heat···|Heat···
(20 °C)|·······|·······|·······|·······|·······|·······|·······|·······|cond.··|capac.·
kg/dm³·|10E-6/K|10E-6/K|10E-6/K|10E-6/K|10E-6/K|10E-6/K|10E-6/K|10E-6/K|W/Km···|J/kgK··
-------+-------+-------+-------+-------+-------+-------+-------+-------+-------+-------
Lauterbach Verfahrenstechnik GmbH 14 12.10.2015
ASME BPVC VIII-1 2015
7,85···|12,1···|12,7···|13,3···|13,8···|14,4···|-······|-······|-······|·······|·······