Resumo PDF
Resumo PDF
Resumo PDF
Department of Civil Engineering, Architecture and Georesources, Instituto Superior Técnico, Technical
University of Lisbon
Av. Rovisco Pais, 1049-001 Lisbon, Portugal
November 2014
ABSTRACT
The structural design of hydropower plants depends on numerous factors. Due to the nature and size
of these structures, not only are these responsible for a high economic impact, but also a high social
and environmental impact.
Therefore, it is essential to define an accurate structural design in reinforced concrete, in order to
ensure the overall stability of the structure.
This dissertation aims to analyse and verify the global and internal stability of a structural block of a
hydroelectric power station. So, it was necessary to define the structural materials and determine the
reinforcement of several structural elements, taking into account the actions on the structure.
Throughout the paper, simplified models and general rules for the design of reinforced concrete
structures are used, as well as their applicability in larger-scale structures is discussed.
In addition, the results were compared with a structural analysis of a three-dimensional model in
SAP2000.
-1-
reinforcement of the elements (i) to (v) is
shown in reinforcement detail drawings.
Lastly, it is used the SAP2000 software to
compare the results.
1.2 BACKGROUND
According to the ASCE 1989 [1], there are two
types of hydropower plants: (i) surface and (ii)
underground power plants.
Figure 1: 3D model of the block no.3 of the
The powerhouse type selection depends on hydropower plant
factors, such as:
o The water conduit length and head 3. STRUCTURAL MATERIALS
developed: in order to make the most
economical solution possible, the distance The durability of a reinforced concrete
between the dam and the hydroelectric structure must be taken into account in its
power station should be the lowest design, in order to ensure that it operates
possible; adequately, without unforeseen maintenance/
o Geological constraints: plants must be repair costs during its working life.
always founded on rock to ensure the Since this is an important structure (working
stability of the structure; life of 100 years and structural class S6,
o Topographic constraints: the form of the according to EC2), it is used structural steel
land has a great impact on the location of S500. The concrete in each zone of the
the plant (eg. steep banks can lead to structure was chosen bearing in mind different
expensive excavations and stability needs (resistance, low heat of hydration, low
problems). permeability, among others).
o The tailwater level: a high level might rule
out indoor surface type power plants; According to the norm NP EN 206-1, the
o Other constraints related to concrete specifications are shown below ( table
environmental, social and economic 1).
aspects. Table 1: Concrete specification of each element
Element Concrete Specification
C25/30; XC3 (P); Cl
2. 3D MODELLING Floor Slabs and Beams
0.40; Dmax25; S3
Using AutoCAD software, it was built the three Upstream Wall
dimensional model of the block, shown in figure Columns and support
C30/37; XC4 (P); Cl
1. beams of the crane rail
0.40; Dmax25; S3
Buttresses
Draft Tube
( )
(9)
6.3 TOPPLING
where is the compressed length of the
Verification against failure by toppling is
foundation and is the vertical resultant of the
provided by (6):
forces.
∑
∑
(6)
destabilization. L
-7-
situations: (i) when it’s full (subjected to Note 2: The beams reinforcement varies in each floor, so it
won’t be presented (it is shown in detail drawings).
hydrostatic pressures); and (ii) when it’s empty
Table 23: Upstream wall longitudinal
(subjected to maximum vertical loads and uplift reinforcement
pressure).
pw1
Upstream Wall
P=qL P=qL
2
Section As1 [cm /m]
8. CONCRETE REINFORCEMENT
SOLUTIONS 9. SAP2000 MODELLING
In tables 22 to 25, it is shown a summary of the In order to assess the structure overall
amount of longitudinal reinforcement used in behavior, it was built a 3D model in SAP2000.
the analyzed elements, in order to verify ULS Thus, it was possible to compare the results
and ELS. obtained with simplified models previously
described.
Table 22: Slabs longitudinal reinforcement
Slabs of the Floors
As
Direction Face 2
[cm /m]
(+) # φ10//0.20 (3.9)
x
(-) # φ10//0.20 (3.9)
(+) # φ10//0.20 + φ8//0.20 (6.4)
y
(-) # φ10//0.20 + φ10//0.20 (7.9)
Note 1: This reinforcement corresponds to the last floor.
The reinforcement of the remaining floors is shown in
detail drawings. Figure 7: 3D SAP2000 model of the block no.3
-8-
In general, the adopted solution described Nonetheless, proper adjustments and
previously was suitable for the forces obtained verifications must be carried out.
using SAP2000.
There were minor differences that most likely 11. REFERENCES
are due to the difference between the support
[1] ASCE (1989), Civil Engineering Guidelines for
conditions assumed in both methods. While Planning and Designing Hydroelectric
SAP2000 is able to calculate the stiffness of Developments, Volume 3: Powerhouses and
each structural element, in simplified models Related Topics, New York;
approximations were considered. [2] Ramos, H.M. (2010), Fundamentos e
Orientações no Projecto de Aproveitamentos
However, it is important to bear in mind that it
Hidroeléctricos, Texto de apoio à disciplina de
is possible to consider limited redistribution Estruturas e Aproveitamentos Hidráulicos, IST;
and for that reason no change in [3] Camelo, A. (2011), Durabilidade e Vida Útil das
reinforcements is needed. Estruturas Hidráulicas de Betão e de Betão
s
Armado, 1ª Jornadas de Materiais na
Construção;
10. CONCLUSION [4] Eletrobrás (2003), Critérios de Projeto Civil de
The design of complex structures, such as Usinas Hidroelétricas;
[5] Quintela, A.C. (1988), Hidraúlica Aplicada II, IST;
hydropower plants must be carefully done, in
[6] Eurocode 2 – Design of concrete structures, Part
order to enable structural safety and proper
1-1: General rules and rules for buildings, EN
operation. Not only is conception important, 1992-1-1:2004;
but also the material selection, execution, [7] ACI 350-01 – Code requirements for
quality control and inspections are important environmental engineering concrete structures;
steps to take into account when designing and [8] Isnard,V., Grekow,A., Mrozowicz,P., Formulario
building a structure. del Ingeniero: Metodos practicos de calculo de
obras de ingeniería, Urmo S.A. Ediciones;
Regarding the structure overall stability, we [9] Appleton, J. (2013), Estruturas de Betão, Volume
can conclude that uplift is the scenario that 1, Edições Orion;
leads to the lowest safety coefficients. This is [10] Gomes, A., Vinagre, J. (1997), Estruturas de
why an accurate calculation of concrete Betão I – Tabelas de Cálculo, Volume III, IST;
volumes is essential. [11] SIA 261/1 (2003) - Actions sur les structures
porteuses – Spécifications complémentaires,
Regarding the structure internal stability, we SIA Zurich;
can conclude that, in many cases, the SLS [12] Camara, J. (2012), Folhas de Apoio às Aulas –
verification (crack control) is determinant while Estruturas de Betão I, Instituto Superior Técnico;
using EC2. A higher thickness of concrete [13] Branco, F., Correia, A. (1990), Modelação de
cover results in higher amounts of Fundações na Analise Estrutural, Relatório
reinforcement, which sometimes seems CMEST Dt 02/90;
[14] Eurocode – Basis of structural design, EN
excessive, when comparing to other countries
1990:2002;
regulations. However, a higher thickness might
[15] Eurocode 2 – Design of concrete structures,
prevent a more hazardous consequence Part 3: Liquid retaining and containment
(water erosion). structures, EN 1992-3:2006;
[16] Eurocode 8 - Design of structures for
All in all, the adoption of simplified models
earthquake resistance, Part 1: General rules,
represent an acceptable method for designing
seismic actions and rules for buildings, EN 1998-
concrete reinforcements, as the results 1:2004;
obtained with the three dimensional model in [17] Almeida, J. (2012), Modelos de Campos de
SAP2000 were similar. Nevertheless, SAP Tensões para Betão Estrutural – dos
results viability depends on the finite element. Fundamentos à Aplicação em Projecto - lição de
The existing differences between the results síntese apresentada no âmbito de provas de
are linked to the support conditions assumed agregação, IST;
in simplified models. [18] APEB (2008), Guia para a utilização da norma
NP EN 206-1: A especificação do betão;
To sum up, general rules and principles for [19] Appleton, J., Marchão, C. (2012), Folhas de
common structures, studied throughout this Apoio às Aulas – Estruturas de Betão II, IST;
master’s degree, can be applied to more [20] DECivil, Tabelas de cálculo da disciplina de
complex structures as a first approach. Dimensionamento de Estruturas, IST.
-9-