NEMA3 - IP Rating PDF

The document provides information on NEMA and IP enclosure ratings: 1) It describes the NEMA rating system used in North America to rate enclosures and associates each NEMA rating with an equivalent IP rating, with NEMA standards meeting or exceeding the IP level. 2) It includes a table listing the NEMA ratings from 1 to 6P, their intended indoor or outdoor uses, the degree of protection provided, and equivalent IP ratings from 20 to 68. 3) It also briefly describes the IP rating system used worldwide to rate enclosures, with ratings written as IP-XY based on levels of contact/foreign body and water protection.

Uploaded by

abhi boyz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
114 views1 page

NEMA3 - IP Rating PDF

The document provides information on NEMA and IP enclosure ratings: 1) It describes the NEMA rating system used in North America to rate enclosures and associates each NEMA rating with an equivalent IP rating, with NEMA standards meeting or exceeding the IP level. 2) It includes a table listing the NEMA ratings from 1 to 6P, their intended indoor or outdoor uses, the degree of protection provided, and equivalent IP ratings from 20 to 68. 3) It also briefly describes the IP rating system used worldwide to rate enclosures, with ratings written as IP-XY based on levels of contact/foreign body and water protection.

Uploaded by

abhi boyz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

To print, right click or press ctrl + P

NEMA & IP TYPE ENCLOSURES


TheNEMAratingsystemispredominantlyusedintheUSandotherpartsofNorthAmericaforratingenclosures.
ThetablebelowdescribeseachoftheNEMAratingsandassociatesthemwiththeequivalentIPrating.NEMA
standardseithermeetorexceedtheIPratinglisted,butthereversecannotbeassumed.
ThefollowingtableisbasedonNEMA250-2003,IEC60529andtheNEMAStandardPublication"ABriefCompari-
sonofNEMA250-EnclosuresforElectricalEquipment(1000VoltsMaximum)andIEC60529--DegreesofProtection
ProvidedbyEnclosures(IPCode).

NEMA Equiv IP
Number Intended use and description Rating

1 Indooruseprimarilytoprovideadegreeofprotectionagainstcontactwiththeenclosed IP 20
equipmentandagainstalimitedamountoffallingdirt.
2 Indoorusetoprovideadegreeofprotectionagainstlimitedamountsoffallingwateranddirt. IP 22
3 Outdoorusetoprovideadegreeofprotectionagainstfallingdirt,windblowndust,rain,and IP 55
sleet;undamagedbytheformationoficeontheenclosure.
3R Outdoorusetoprovideadegreeofprotectionagainstfallingdirt,rainandsleet;undamaged IP 24
bytheformationoficeontheenclosure.
3S Outdoorusetoprovideadegreeofprotectionagainstfallingdirt,windblowndust,rain,and IP 55
sleet;externalmechanismsremainoperablewhileiceladen.
4 Indoororoutdoorusetoprovideadegreeofprotectionagainstsplashingwater,windblown IP 66
dustandrain,andhose-directedwater;undamagedbytheformationoficeontheenclosure.
4X Indoororoutdoorusetoprovideadegreeofprotectionagainstsplashingwater,windblown IP 66
dustandrain,andhose-directedwater;undamagedbytheformationoficeontheenclosure;
resistscorrosion.
6 Indoor or outdoor use to provide a degree of protection against the entry of water IP 67
duringtemporarysubmersionatalimiteddepth;undamagedbytheformationoficeonthe
enclosure.
6P Indoororoutdoorusetoprovideadegreeofprotectionagainsttheentryofwaterduringpro- IP 68
longedsubmersionatalimiteddepth.
12,12K Indoorusetoprovideadegreeofprotectionagainstingressoffallingdirt,circulatingdust, IP 54
lint,fibersandflyingsandharmfuleffectsonequipmentduetodrippingandlightsplashing
ofwater.(12withoutknockouts/12Kwithknockouts).
13 Indoorusetoprovideadegreeofprotectionagainstingressoffallingdirt,circulatingdust, IP 54
lint,fibersandflyings,spraying,splashingandseepageofoilandnon-corrosivecoolants,
andprovideadegreepfprotectionwithrespecttoharmfuleffectsonequipmentduetodrip-
pingandlightsplashingofwater..

TheIPRatingsystem(orInternationalProtectionCode)isaworldwidestandardforratingenclosures.Theratingis
writtenasIP-"XY"whereXandYarereplacedbythefirstandseconddigitsaslistedinthetablesbelow.

Degree of protection from contact or Degree of water protection


foreign body
1st Digit Brief Description 2nd Digit Brief Description

0,1,2 Nospecialprotection.Generallynot 0 Nospecialprotection.Generallynotusedfor


used for pressure or temperature pressureortemperatureinstruments
instruments. 1 Protectedagainstdrippingwater
3 Protectedagainstsolidobjects 2 Protectionagainstdroppingwaterwhencaseistiltedupto15°
≥2.5mmindiameter
3 Protectedagainstsprayingwater
4 Protectedagainstsolidobjects
4 Protectedagainstsplashingwater
≥1.0mmindiameter
5 Protectedagainstawaterjet
5 Dustprotected
6 Protectedagainstheavyjetspray
6 Dusttight
7 Protectedagainstlimitedsubmersion
8 Protectedagainstcontinuoussubmersion