MEDIUM VOLTAGE CONTROLLERS

CENTERLINE
®

MEDIUM VOLTAGE MOTOR CONTROL

Manufacturers share the challenge of efficiently controlling


motors to improve performance, reduce power consumption
and protect motor investment. Of all the motors in your
manufacturing process, medium voltage motors can have a
large impact on your continued success. Developing
medium voltage motor control and protection has been a
core discipline for Rockwell Automation® for more than
100 years. Medium Voltage products, from across-the-line
starters to soft starters and variable frequency AC drives,
deliver enhanced protection in applications ranging up to
several thousand horsepower. Bringing motors up to speed
in a controlled manner, limiting wear on the motor and
other mechanical components, and protecting your
investment are key benefits of Rockwell Automation medium
voltage systems.

O.E.M. frames and components provide OEMs and electrical


equipment companies with custom-engineered solutions and high
quality components. Both the medium voltage controller and SMC
product lines offer smaller, more flexible individual components to
reduce building and expansion costs. Open-frame style structures are
also available with most medium voltage components already
mounted within the frame. All OEM components are manufactured to
meet UL, CSA, CE and IEC standards.

Allen-Bradley® medium voltage motor controllers are available


in a wide range of control formats allowing the flexibility to select
the best match for the application. Medium voltage full-voltage
controllers, reduced voltage controllers, solid-state reduced-voltage
controllers, two-speed controllers, synchronous controllers and load
break switches provide integrated intelligence and the lowest cost
solution for starting motors.

2
A COMPLETE LINE OF INDUCTION
AND SYNCHRONOUS CONTROLLERS

Solid-state reduced voltage controllers apply reduced voltage to a medium voltage


AC motor to allow soft starting and stopping, limitation of the inrush current, and
reduction of the effects of water hammer in pumping systems. Allen-Bradley MV SMC
Flex™ controllers include motor protection, communication and diagnostic capabilities and
high flexibility, making it ideal for virtually any application.

IntelliCENTER™ provides MCC users with an integrated hardware, software and


communication solution. The IntelliCENTER features pre-configured software which shows
real-time data, trending, component history, wiring diagrams, user manuals and spare
parts. The IntelliCENTER reduces installation time with its plug-and-play set-up and
minimizes facility downtime by quickly providing intelligent diagnostic and predictive
failure information.

Arc resistant controllers Rockwell Automation has enhanced the safety of its world
recognized medium voltage control products to include an optional arc resistant class of
medium voltage control equipment. ArcShield™ controllers provide the additional arc
resistant safety features required by some industries. Most medium voltage control
products can be provided with the ArcShield enclosure design which meets the arc
resistant testing requirements of IEEE C37.20.7. ArcShield controllers use the same
standard reliable internal components that continue to serve industries world wide.

Variable frequency AC drives Allen-Bradley medium voltage drives provide a single


solution for all medium voltage speed control requirements. The PowerFlex® 7000 family
of drives exceeds customer expectations by delivering superior reliability, ease of use and
lower total cost of ownership. The advanced power semiconductor technology reduces
component count to the lowest of any medium voltage drive available, translating to
increased savings and reliability, less downtime and fewer spare parts.
INTELLICENTER
INTEGRATED INTELLIGENCE WITHIN AN MCC

Built-in DeviceNet
DeviceNet ports in horizontal wireway
• Simplifies installation
• Complex I/O interwiring is reduced to a single DeviceNet cable
• New 8 ampere, Class 1 DeviceNet cabling
• Tested for noise immunity

Power Monitor 3000


• Displays volts, amperes, hertz, watts, demand watts,
peak demand, kWH/kVARH, power factor
• Logs min/max values, snapshot values, harmonic waveforms
• Programmable outputs indicate over voltage, under voltage
and phase imbalance, loss or reversal
• Communicates via Ethernet, ControlNet, DeviceNet,
Remote I/O, RS-232 or RS-485

DeviceNet Starter Auxiliary (DSA)


Interface module fon non-intelligent devices
• Motor starter with eutectic alloy
• Feeders and mains 4 input points
• Ideal for monitoring contactor status, disconnect switch,
overload trip and Hand-Off-Auto switch

E3 Solid-State Overload Relay


DeviceNet on-board Protective functions
2 or 4 input points • Overload, underload
1 or 2 output points • Phase loss / imbalance
Information: • Stall and Jam
• Time-to-trip, time-to-reset • Ground fault (Plus version)
• % thermal capacity utilized Settings for protective functions
• Cause of last five trips • Trip level, Warning level
and warnings • Time delay
Phase and average current

825-P Modular Protection System


• DeviceNet communications (optional card)
• Three output relays
• Two configurable inputs
• Ground fault CT input
• Metering capability
• RTD scanner module with 12 inputs (optional)

4
IntelliCENTER Software
• Spare parts lists specific to each unit
• AutoCAD® elevation and one-line drawings
• User manuals specific to each unit
• Event logging, warnings, faults,
parameter edits

IntelliCENTER Software
• Features pre-configured screens for each unit
• Allows MCC monitoring from anywhere in the
user’s facility
• Contains Active X controls to allow easy
integration into RSView
MV SMC FLEX
UNMATCHED INTELLIGENT MOTOR CONTROL

Why use Smart Motor Controllers (SMCs)


SMCs provide many features to benefit your system:
• Minimize mechanical damage resulting from full
voltage starting of AC induction motors, enabling
longer system life
• Limit line disturbances from inrush currents, resulting
in reduced downtime
• Multiple Start/Stop modes increase functionality
• Diagnostic monitoring helps prevent problems before
they occur
• Satisfy electrical distribution restrictions by reducing
inrush currents

SMCs are ideal for applications where:


• Belts, gears, and chains can be damaged by across-
the-line starting
• Materials can be damaged by sudden starts and stops
• A step change in torque can damage equipment
• Power company line current restrictions are imposed

With SMC soft starters you benefit from:


• Advanced diagnostics, increasing system performance
• Greater product functionality for increased system
flexibility
• Decreased downtime due to advanced protection of
motor winding, equipment, and materials

The MV SMC Flex controller furnishes as


standard a full range of starting and stopping
methods for a variety of applications. Its unique
control options offer enhanced motor starting
and stopping capabilities to satisfy your most
demanding applications.

SOFT START SOFT STOP CU


MV SMC Flex™ Smart Motor Controller offers:
Standard Control Module
• Soft start - with selectable kickstart
• Soft stop
• Current limit start - with selectable kickstart
• Linear speed acceleration * - with selectable kickstart
• Linear speed deceleration
• Full voltage
• Preset slow speed
* requires motor tachometer

Optional Control Module


• Pump control (eliminates water hammer)
- Separate start and stop profiles

Standard Features of SMC Flex Controller


• Electronic motor overload protection
• Metering
• Diagnostics
• Built-in DPI communications (other
communication options available)
• Two-line, 16-character backlit LCD display
keypad programming
• Three programmable auxiliary contacts

MV SMC Flex Power Module


• Current loop gate drive (patent pending)
• Efficient heat sink profile

Bulletin 1560E Bulletin 1562E

Retrofit Controller Combination Controller

CURRENT LIMIT PUMP CONTROL FULL VOLTAGE LINEAR SPEED


(Optional)

7
ARCSHIELD
®

ARC RESISTANT MEDIUM VOLTAGE CONTROLLERS

The Allen-Bradley Centerline® ArcShield arc resistant controller provides


rugged process control for applications requiring a higher level of personnel
protection. ArcShield products are compliant to the IEEE C37.20.7 standard,
and provide Type 2 protection. During an arc flash, the ArcShield controller
safely redirects the arc flash energy out the top of the unit and away from
personnel. This level of protection is also maintained when the low voltage
door is open for maintenance purposes.

Actual photographs of successful ArcShield tests

8
Offering a wide variety of Centerline ArcShield products:
The ArcShield products are available in a
number of different controller configurations.
Side view (common to all products)
Here are just a few of the products available:
• Bulletin 1591A Incoming units
• Bulletin 1512A/AT One high controller
• Bulletin 1512B/BT Two high controller
• Bulletin 1562E MV SMC Flex controller

Arc “Pressure Relief” Vent


• Safely vents arc gases and material away from
personnel during an arc flash
• Arc gases are vented out the top of the
enclosure through the plenum exhaust structure

Heavy Duty Enclosure Design


• Reinforced side sheets, doors, roof, and back
plates designed to contain arc flash energy
while vents open Front
• Added support plates secured with multiple
bolts provide increased rigidity and security

Robust Power Cell Door Design


• Multi-point latching mechanism,
reinforced cross bracing and gasket
sealing provide arc containment
• A viewing window in the power
cell door allows the operator to
view the status of the isolation
switch before opening the door
• Once the latching mechanism is
engaged, the power cell door is
bolted shut for added protection

9
BUILDING BLOCKS
At Rockwell Automation, we are committed to
providing the products and services that our
customers demand. Over the past eighty years,
Allen-Bradley medium voltage Centerline®
controllers have set the standard by which others
are measured. Our unmatched quality and
innovative designs have made us the leader in
medium voltage motor control products.

ADVANCED DIGITAL CONTROL


OF VACUUM CONTACTORS

The Allen-Bradley Bulletin 1503VC IntelliVAC


controller offers a superior and efficient means of
controlling vacuum contactors. IntelliVAC controllers
are a quantum leap beyond traditional
electromechanical control circuits. Here are just a few
of the beneficial characteristics:

• The performance and flexibility of digital control,


allowing the control of a wide array of contactor
types (400A, 800A electrically held, and
mechanical latch)

• Enhanced reliability as a result of embedded self


diagnostics and better coordination between unit
power fuses and the vacuum contactor drop-out time
• Increased productivity with features like power loss
ride through (TDUV) and contactor anti-kiss, which
were previously offered as optional features
• Motor and process protection with delayed restart
built-in
NON-LOAD BREAK ISOLATION SWITCH
• Electrical and mechanical interlocks prevent the switch from
opening when the contactor is energized
• Ensures normal operation only when the switch is fully closed
• Allows for separate source testing when in the “OFF” position
• Grounded in the “OFF” position
• When in the open position, a visible barrier isolates the power cell
from the power bus compartment
• Status of the isolation switch can be viewed through a window in
the power cell door

HANDLE AND INTERLOCK MECHANISM


• Simple direct drive mechanism improves reliability and ensures
operator safety
• Mechanical interlock mechanism remains part of the enclosure
to eliminate setup adjustment
• Power cell door is interlocked with the handle mechanism to
prevent the door from being opened when the cell is energized

LOW VOLTAGE COMPARTMENT


• Separate 120 volt source is required for “Test” position
control power
• Allows testing and troubleshooting of the power cell without
exposing personnel to medium voltage
• Prevents backfeeding medium voltage through the control
transformer, in “Test” mode
• All low voltage components are located in the low voltage panel
• Low voltage panel interior painted white for better visibility

POWER CELL COMPARTMENT


• Power cell, low voltage panel, and bus compartment are isolated
from each other for better fault containment
• Swing out low voltage panel for easy access to install load cables
• Isolated load cable compartments between top and bottom
power cell
• Easy access for cable installation and stress cones
• Bar type current transformers are supplied as standard for
overload protection and metering

POWER BUS COMPARTMENT


• Centerline bus designed as an integral part of the structure
• Dissipates heat more efficiently
• Edge-to-edge configuration maximizes resistance to magnetic
forces and minimizes moisture or dust collection
• Molded bus brace reduces maintenance and provides better
distribution of forces during a fault
• Accessible without a ladder, for installation and maintenance
• Allows for incoming line cables to enter through the top or
bottom of the compartment

11
INTELLIGENT
MOTOR CONTROL
MEETING TOMORROW’S MANUFACTURING NEEDS...TODAY

We understand that you need to control performance, reduce


downtime, improve safety, increase productivity, and perform
diagnostics. That’s why we’ve combined leading-edge motor control
and protection devices with the advanced networking and diagnostic
capabilities of Rockwell Automation’s Integrated Architecture to
provide you with Intelligent Motor Control.

PROTECTION
Thanks to integrated I/O and advanced diagnostic and protection
capabilities, all Intelligent Motor Control products constantly
monitor the motor operation to help you follow performance trends
and take remedial action before potential failures occur. Reduce
unwanted downtime by 75% while increasing overall production
efficiency by 10% or more.

12
COMMUNICATIONS
Because you have a wide range of
application needs, Intelligent
Motor Control offers a variety of
motor control technologies.

Simplified control technologies are


designed to suit your needs
• DeviceLogix™ component
technology increases the control
One-High MV SMC Flex IntelliCENTER PowerFlex 7000
possibilities with function block
Controller Controller Controller AC Drive
diagrams that operate at the
device level
• DriveLogix™ offers embedded Login control SCALABLE FUNCTIONALITY
for application programmability and control of
auxiliary functions in one package

Integrated Architecture enables you to reduce your total cost of


ownership by using a single control infrastructure for the entire range of
factory automation applications, large or small
• Reuse engineering designs and practices to reduce development time
and cost
• Quickly respond to customer or market demands
• Reduce maintenance costs and downtime
• Easily access plant and production data from business systems
or better management decision-making

COMMUNICATIONS
The key to intelligence in motor control...

Utilize open networked architecture to enhance


motor protection, share diagnostic information
and speed troubleshooting for a more productive,
“intelligent” process.

• From simple I/O to complex power monitoring


tasks, DeviceNet™ lets your cost effectively
integrate many low-level manufacturing functions
• NetLinx open network technology provides
seamless communications throughout your
enterprise (DeviceNet, ControlNet, and EtherNet/IP)
• Flexibility and commonality of communications
across the product offering makes Intelligent Motor
Control easy to use
O.E.M. PRODUCTS
QUALITY COMPONENTS FOR THE OEM MARKET
From the original oil-immersed contactor to air break and vacuum contactor, to solid-state controllers
such as Smart Motor Controllers and AC Variable Frequency Drives, Rockwell Automation has
developed and built a medium voltage product line that satisfies industries who are demanding more
safety, less maintenance, longer life and reliability in motor control equipment.

Added to those demands is the need for smaller, more flexible medium voltage products that are more
efficient and reduce building and expansion costs.

OEM Frames and components leverage the existing family of motor controllers built by Rockwell
Automation. They also incorporate some of the most fundamental, high volume components available
in our OEM product line for Original Equipment Manufacturers and electrical equipment companies.

Bulletin 1502 vacuum contactors are a comprehensive line of vacuum contactors used as isolating
contactors or as bypass contactors. Light weight and maintainability are but two of the features of this
fixed-mounted design.

Bulletin 1503F OEM components are a series of medium voltage frame-mounted components designed
to mount into new or existing structures or enclosures. These assemblies can also be used to retrofit
existing motor controllers. These products are available as a complete OEM frame or sold individually
as components.

Bulletin 1503E MV SMC Flex™ OEM kits are a series of solid-


state reduced voltage components designed to mount into
new or existing structures or enclosures. These assemblies
can also be used to retrofit existing motor controllers. These
products are available as an OEM frame and components.

Bulletin 1901 SyncPro™ is a field application and protection


system for squirrel-cage, brush-type synchronous motors.
General Features
Medium Voltage Motor Controllers

Description of Features • IntelliVAC™ control module for each vacuum contactor, mounted
in low voltage panel, with advanced features:
Designed for Safety, Convenience and Reliability – Universal input voltage (110-240V AC, 50/60 Hz or 100-250V DC)
– Selectable vacuum contactor drop-out time and consistent pick-
The Allen-Bradley medium voltage controller offers: up time
• Three isolated compartments: – Altitude compensation
- Power bus – Power loss ride-through (TDUV) – may require additional
- Low voltage hardware (external capacitor)
- Power cell – Anti-kiss and anti-plugging protection
• Large swing-out low voltage panel painted white for high visibility – Delayed motor re-start and temporary motor jog function
• Test circuit and plug for remote control power supply – One device is suitable for all contactors and control schemes
• External operating handle to operate the isolation switch
• Bolted power cell door(s)
Input Voltage
• Centerline® horizontal power bus with removable cover plates for
• 2400V, 3300V, 4200V, 6600V or 6900V AC (+5/-10%)
accessibility
• 3 phase 50/60 Hz (± 3%)
• 1/4” x 2” continuous copper ground bus
• Line, load and control wire conduit openings with removable cover
Ambient Temperature
plates at the top or bottom of the structure
• Base mounting sill channels with mounting holes and removable • 0°C to 40°C (32°F to 104°F) with relative humidity of
up to 95% (non-condensing)
lifting means
• Hybrid epoxy powder paint finish
Enclosure Types
• NEMA Type 1 – General purpose (IP10)
Controller Standard Features
• NEMA Type 1 w/g – General purpose with gasket (IP21)
• NEMA Class E2 design • NEMA Type 12 – Dust-tight and drip proof (IP52)
• Removable lifting angles or brackets • NEMA Type 3R – Non walk-in weatherproof (IP34)
• Non-removable sill channels • Arc Resistant (NEMA Type 12) – Accessibility Type 2
• Removable backplates – Tested per IEEE C37.20.7-2001
• Top or bottom plates to accommodate cable entry/exit
• Tin-plated copper horizontal power bus located in an isolated Standards
compartment • Canadian Standards Association (CSA),
• A ¼” x 2” continuous bare copper ground bus Industrial Control Equipment C22.2 No. 14 and TIL D-21
• A main non-load break isolation switch with visible blades • American Nation Standards Institute (ANSI),
and shutter mechanism, and operating handle Instrument Transformers C57.13
• Mechanical and electrical interlocks between isolation switch, • Institute of Electrical & Electronic Engineers (IEEE)
vacuum contactor and MV door • National Electrical Code (NEC)
• Vacuum contactor(s) • Occupational Safety & Health Act (OSHA)
• Three (3) current limiting power fuses for NEMA Class E2 operation • Guide for Harmonic Control and Reactive
• Three (3) current transformers Compensation of Static Power Converters (IEEE 519-1992)
• Control circuit transformer with primary and secondary fuses • National Electrical Manufacturers Association (NEMA),
• A low voltage control panel Medium Voltage Controllers Rated 1501 to 7200 V AC ICS 3-2
• Space for necessary auxiliary control and metering devices (formerly ICS 2-324)
• Polycarbonate viewing window in power cell door • Underwriters Laboratories, Inc. (UL),
High Voltage Industrial Control Equipment 347
• European Directives for EMC

Visit our Web site: www.ab.com.catalogs 15


General Features
Medium Voltage Motor Controllers

Description of Features (cont.)


Paint Finishes
• Description Hybrid epoxy power paint
• Color ANSI 49 – medium light grey (standard)
ANSI 61 – light grey (optional)
• Procedure Continuous paint line. All parts are painted
before assembly
• Preparation Alkaline wash/rinse/iron phosphate
rinse/iron-chrome sealer
rinse/recirculated de-ionized water
rinse and virgin de-ionized water rinse
• Painting Air-atomized electrostatic spray
Total paint thickness – 0.002”
(0.051 mm) minimum
• Baking Natural gas oven at 179°C (355°F) minimum

Power Bus (Optional)


• Located at the center rear of the structure
• Mounted on the edge to a molded bus support insulator
in a common vertical plane
• Centerline™ horizontal tin-plated copper bus
– optional silver-plated or insulated
• 1200/2000/3000 A
• Front/rear access

Ground Bus
• Continuous bare copper ground bus 6 x 52 mm (1/4 in x 2 in)
as standard
• #8 - #1/0 AWG or #6 – 250 MCM mechanical lug
supplied at the incoming end of the lineup

16 Visit our Web site: www.ab.com.catalogs


Bulletin 1500
Medium Voltage Controller Components

Description of Features Operating Handle and Interlock Mechanism


The Rockwell Automation Medium Voltage Controller, • Simple direct drive mechanism improves reliability and ensures
Bulletin 1500, is comprised of three core elements: operator safety
• Mechanical interlock mechanism remains part of the enclosure to
• Power cell compartment eliminate setup adjustment
• Low voltage compartments
• Power bus compartments • Power cell door is interlocked with the handle mechanism to
prevent the door from being opened when the cell is energized

Power Cell Compartment


Isolation Switch
• Electrical and mechanical interlocks prevent the switch from
opening when the contactor is energized
• Ensures normal operation only when the switch is fully closed
• Allows for separate source testing when in the “OFF” position
• Grounded in the “OFF” position

Current Transformers
• Three (3) current transformers are supplied as standard
for overload protection and metering
• Five (5) amp secondary output

Visible Isolation
• When in the open position, a visible barrier isolates the power cell
from the power bus compartment
• Status of the isolation switch can be viewed through a window in
the power cell door

Isolated Cable Ducts Control Power Transformers


• Easy access for cable installation • 110/120 or 220/240 V AC
• Ample room for stress cones • 500 VA as standard with 350 VA extra capacity
• Provides isolated load cable compartments between top and • Appropriately sized primary and secondary fuses
bottom power cells
• 1000 VA, 2000 VA, and 3000 VA CPTs (optional)

Vacuum Contactor
• Modular design for simplified maintenance and reliability
• Fixed mounted design eliminates hot spots and
reduces maintenance
• Visible contact wear indicator eliminates the need for special tools

Swing-out Low Voltage Panel (for 2-high structure)


• Allows for easy access to install load cables
• Maximizes low voltage panel space

Visit our Web site: www.ab.com.catalogs 17


Bulletin 1500
Medium Voltage Controller Components

Description of Features (cont.) Power Bus Compartment


Centerline Bus Design
• Designed as an integral part of the structure
Low Voltage Compartment
• Dissipates heat more efficiently
• Edge-to-edge configuration maximizes resistance to magnetic
forces and minimizes moisture or dust collection
• Molded bus brace reduces maintenance and provides better
distribution of forces during a fault
• Accessible without a ladder, for installation and maintenance
• Allows for incoming line cables to enter through the top or bottom of
the compartment

Low Voltage Compartment Control Panel


• Separate 120 volt source is required for “Test” position control
power
• Allows testing and troubleshooting of the power cell without
exposing personnel to medium voltage
• Prevents backfeeding medium voltage through the control power
transformer, in “Test” mode

Isolated Compartment
• All low voltage components are located in the low voltage panel
• Low voltage panel interior painted white for better visibility
• Power cell, low voltage panel, and bus compartment are isolated
from each other for better fault containment
• IntelliVAC control module

18 Visit our Web site: www.ab.com.catalogs


Bulletin 1500
Medium Voltage Controller Components – IntelliVAC™ Controller

IntelliVAC Control Module


• The IntelliVAC control module has a universal input voltage range
(110 - 240 VAC, 50/60 Hz or 110 - 250 VDC)
• Consistent vacuum contactor pick-up time, ensures optimal
synchronization
• Selectable and repeatable vacuum contactor drop-out times (50,
75, 100, 130, 150, 175, 200 or 240 msec) for tighter coordination
with power fuses
• Altitude compensation ( -1,000 to 5,000 meters) eliminates
mechanical hardware changes at high altitude (400 Amp vacuum
contactors)
• Power loss ride-through logic (TDUV) with selectable drop out time
(0.2, 0.5, 1.0 or 2.0 sec) requires only an external capacitor
• Anti-kiss and anti-plugging protection
• Status indication (LEDs and relay outputs) allows integration in
control system and aids troubleshooting
• Temporary motor jog function (separate input) to allow process
set-up
Description of Features • Delayed motor re-start prevents rapid cycling of vacuum contactor,
protecting the connected motor
The Allen-Bradley IntelliVAC™ controller offers a superior and
efficient means of controlling vacuum contactors.
IntelliVAC controllers are a quantum leap beyond traditional
electromechanical control circuits. Here are just a few of the
beneficial characteristics:
• The performance and flexibility of digital control, allowing the
control of a wide array of contactor types (400 A, 800 A, Electrically
Held and Mechanical Latch)
• Enhanced reliability as a result of embedded self diagnostics and
better coordination between unit power fuses and the vacuum
contactor drop-out time
• Increased productivity with features like power loss ride through
(TDUV) and contactor anti-kiss, which were previously offered as
optional features
• Motor and process protection with delayed restart built in

IntelliVAC controllers are designed to perform with Bulletin 1502


vacuum contactors. These industry-proven contactors are available
in 400 A and 800 A ratings up to 7,200 volts.

Visit our Web site: www.ab.com.catalogs 19


Bulletin 1500
Medium Voltage Controller Components – IntelliVAC™ Controller

Specifications

Typical Control Schematic – 400A Electrically Held Vacuum Contactor


CONTROL POWER

CONTROL M-INTELLIVAC
POWER
FUSE 7 + - 8
OPEN

9 + - 10
CLOSE
OVERLOAD START
STOP
16 CONTACTOR
STATUS
15

MODULE 14
STATUS
13
CAPACITOR
(OPTIONAL)
1 - 4
EC TCO
2 + 3
MOV
M
11 6 M
AUX CCO
12 5

CONFIGURATION
DIP SWITCHES

INPUT POWER
L1 G L2/N

20 Visit our Web site: www.ab.com.catalogs


Bulletin 1500
Medium Voltage Controller Components – Vacuum Contactors

Applications
Medium Voltage (1,000 to 7,200 V) vacuum switching for:
• Motor Starters (asynchronous, synchronous)
– Full voltage
– Reduced voltage
– Variable frequency drives
• Transformer feeder units
• Capacitors

Product Approvals
• UL347
• CSA 22.2 No. 14 and TIL D-21
• IEC 60470
• CE Mark

Modular Construction
• Designed to be interchangeable with other contactors of the same
Description of Features rating
The Allen-Bradley vacuum contactors are designed as fixed • Horsepower rated devices are located elsewhere in the power cell,
mounted devices for heavy-duty industrial performance. This design not on the contactor
eliminates the worries typically associated with drawout contactors. • Easily removed for maintenance and repair

The compact design of the contactor eliminates the need for it to be Vacuum Bottles
removed from the power cell. Also there are no drawout stab and
finger assemblies, which require routine maintenance. • Designed to industry specifications
• Arcing confined inside vacuum bottle for ionized gas protection
The Series E contactors are designed for operation with Rockwell • Mounted on the front of the contactor for visible inspection
Automation’s IntelliVAC control module. • Contact wear indicators located on the bottle eliminates the need
for special tools
• Excellent dielectric recovery provides high switching frequency
Advantages
• Lightweight, compact design Long Electrical and Mechanical Life
• High interrupting capability • 1,000,000 electrical operations (400 A)
• Low chop current • 2,500,000 mechanical operations (400 A)
• Visual contact wear indicator (no measurement tools required)
• Provisions for mechanical interlocking (to isolation switch)
• Excellent dielectric recovery allowing for high switching frequency
• Single coil/core magnet assembly (800 A only)
• Control power transformer primary fuse holders (400 A only)
• Minimal maintenance required
• All major components are easily accessed from the front
• Mechanical latch design (optional)
• Easily integrated into control circuit with quick connector and wire
harness (optional)
• Designed to complement the advanced features of the IntelliVAC
contactor control module

Visit our Web site: www.ab.com.catalogs 21


Bulletin 1500
Medium Voltage Controller Components – Vacuum Contactors

Specifications

22 Visit our Web site: www.ab.com.catalogs


Bulletin 825-P
Key Rockwell Automation Options – Modular Protection System

Description of Features System Overview


Basic Unit
• 0.5 to 5000A Current Range
• Suitable for Low- and Medium-Voltage Applications
• Built-in Keypad and Backlit 2-Line LCD
• Test / Reset Button
• Status LEDs
• Front accessible RS 232 port
• Wide Supply Voltage Range (110...240V AC/DC)
• Three Output Relays
• Two Configurable Inputs
• PTC thermistor Input
• Core Balance Current Transformer Input
• Fiber Optic Port for Remote RTD Scanner
• Three option card slots
• NEMA 12 (IP65) Housing
The Bulletin 825-P Modular Protection System for motors offers
a compact, modular design that uniquely allows an installer to
configure a device’s functional capabilities to match the application
requirements.

Flexibility is also afforded by accommodating future expansion of the


system as the application requirements grow. Ease of installation is
provided through pluggable options and accessories.

Finally, this next generation design offers greater capabilities with


the option of full metering for line voltage and power monitoring in
addition to expanded RTD monitoring.

The 825-P Modular Protection System is a key component to Bulletin


1500 medium voltage controllers.

Converter Modules
• Compact Three-Phase current transformer modules
• Provides electrical isolation
• Six current ranges
• 0.5 to 2.5 A
• 2.5 to 20 A
• 20 to 180 A
• 160 to 630 A
• Compatibility with MCS PLUS Bulletin 100-D contactors

Visit our Web site: www.ab.com.catalogs 23


Bulletin 825-P
Key Rockwell Automation Options – Modular Protection System

System Overview (cont.)

Core Balance Current Transformer Option Cards


• Sensitive, low level ground fault detection Voltage Input
• 100:1 ratio • Input terminations for VA, VB, VC and VN
• 110 mm window opening • Enables voltage and power measurement and related protection
Note: The 825-P is compatible with core balance current transformer functions
ratios of 1:1 to 2000:1. • Accommodates potential transformers for levels exceeding 250V AC
DeviceNet™or Modbus™ Communications
• Direct network access for control and monitoring
• DeviceNet communications card features DeviceLogix™
component technology for enhanced control capability
• DeviceNet communication card provides compatibility with the
IntelliCENTER software
Expansion I/O
• Three Configurable Inputs
• Four Auxiliary Relay Outputs
• 4 to 20mA Isolated Analog Output

RTD Scanner Module


• 12-channel inputs
• Compatible with 100½ Platinum, 100½ Nickel, 120½ Nickel,
and 10½ Copper type RTDs
• Can be remote mounted near the motor, simplifying wiring
• Class 1, Division 2, Group T4A rated
• Noise immune fiber optic connection to the Basic Unit
• Channels are individually configurable for RTD type and location
(winding, bearing, ambient, or other).

24 Visit our Web site: www.ab.com.catalogs


ArcShield

The ArcShield products have a robust enclosure design which contain


the arc flash energy and exhaust materials until vents on top of the
enclosure open. Once opened, the vents provide a path for materials
to exit the enclosure. An overhead plenum is used to direct the
materials to a safe location, away from personnel near the equipment.
The low voltage panel is reinforced and sealed, to prevent arc flash
exhaust materials from entering this compartment.

As standard, a plenum exhaust section is provided with each new


ArcShield order. The plenum exhaust section can be mounted on
either the left or right end of the line-up, and it extends 40 inches (or
1016 mm) past the end of the line-up.

As the ArcShield may have an impact on horsepower ratings, please


contact your Rockwell Automation office to confirm.

Engineered Features
• Reinforced cabinet and power cell door closure mechanism
• Multi-point latching mechanism, reinforced cross bracing and
Description of Features gasket sealing
• Reinforced back plates – added support plates secured with mul-
The Allen-Bradley Centerline ArcShield arc resistant controller provides tiple bolts provide increased rigidity and security
rugged process control for applications requiring a higher level of • Reinforced low voltage panel to withstand arc flash energy and
personnel protection. ArcShield products are compliant to the IEEE shield maintenance personnel while working in the isolated low
C37.20.7 standard, and provide Type 2 protection during an arc flash. voltage compartment
• Arc “Pressure Relief” vent to safely vent arc gases and material
The ArcShield controller safely redirects the arc flash energy out the
away from personnel during an arc flash
top of the unit and away from personnel. This level of protection is
also maintained when the low voltage door is open for maintenance • Available with removable arc exhaust plenum
purposes.

Specifications

Visit our Web site: www.ab.com.catalogs 25


Bulletin 1506
Medium Voltage Controller – Full Voltage Reversing Starter

Description of Features
• Fixed mounted vacuum contactors (FORWARD and REVERSE)
• Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
• A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
• Three (3) R-rated current-limiting power fuses
• Three (3) current transformers
• Control power transformer with primary and secondary fuses
• Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
• IntelliVAC™ control module for each vacuum contactor, mounted
in low voltage panel, with advanced features:
• Additional low voltage control panel accessories including:
– “NORMAL-OFF-TEST” circuit
– receptacle for external test power supply
400 amp
– set of control circuit terminal blocks
• Available for motor loads
• Plugging or anti-plugging duty
• Mechanically and electrically interlocked contactors

Specifications

Power Circuit Schematic – 1506

26 Visit our Web site: www.ab.com.catalogs


Bulletin 1512A
Medium Voltage Controller – Full Voltage Non-Reversing (One-High) Starter

Description of Features
• Fixed mounted vacuum contactor
• Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
• A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
• Three (3) R-rated current-limiting power fuses
(R-rated power fuses used for 450 A, 600 A and 800 A starters)
• Three (3) current transformers
• Control power transformer with primary and secondary fuses
• Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
• IntelliVAC™ control module for each vacuum contactor, mounted
in low voltage panel, with advanced features:
• Additional low voltage control panel accessories including:
400 Amp – “NORMAL-OFF-TEST” circuit
– receptacle for external test power supply
– set of control circuit terminal blocks
• 1-high structure design for one complete motor controller
• Available in optional ArcShield enclosure
• Also available as “Prepared Space” (Bulletin 1512AP, 200A and
400A only) or Starter Kits (Bulletin 1512AS)

Specifications

Power Circuit Schematic – 1512A

Visit our Web site: www.ab.com.catalogs 27


Bulletin 1512AT
Medium Voltage Controller – Full Voltage Transformer Feeder Unit Starter

Description of Features
• Fixed mounted vacuum contactor
• Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
• A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
• Three (3) E-rated current-limiting power fuses
(R-rated power fuses used for 450 A, 600 A and 800 A starters,
and for 400 A 6600V/6900V starters)
• Three (3) current transformers
• Control power transformer with primary and secondary fuses
• Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
• IntelliVAC™ control module for each vacuum contactor, mounted
in low voltage panel, with advanced features:
400 Amp • Additional low voltage control panel accessories including:
– “NORMAL-OFF-TEST” circuit
– receptacle for external test power supply
– set of control circuit terminal blocks
• 1-high structure design for one complete transformer controller
• Available in optional ArcShield enclosure
• Also available as “Prepared Space” (Bulletin 1512AP, 200 A and
400 A only) or Feeder Kits (Bulletin 1512AU)

Specifications

Power Circuit Schematic – 1512AT

28 Visit our Web site: www.ab.com.catalogs


Bulletin 1512B
Medium Voltage Controller – Full Voltage Non-Reversing (Two-High) Starter

Description of Features
• Fixed mounted vacuum contactor
• Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
• A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
• Three (3) R-rated current-limiting power fuses
• Three (3) current transformers
• Control power transformer with primary and secondary fuses
• Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
• IntelliVAC™ control module for each vacuum contactor, mounted
in low voltage panel, with advanced features:
• Additional low voltage control panel accessories including:
– “NORMAL-OFF-TEST” circuit
– receptacle for external test power supply
400 Amp – set of control circuit terminal blocks
• 2-high structure design for two complete motor controllers
• Available in optional ArcShield enclosure
• Also available as “Prepared Space” (Bulletin 1512BP) and Starter
Kits (Bulletin 1512BS)

Specifications

Power Circuit Schematic – 1512B

Visit our Web site: www.ab.com.catalogs 29


Bulletin 1512BT
Medium Voltage Controller – Full Voltage Transformer Feeder Unit
(Two-High) Starter
Description of Features
• Fixed mounted vacuum contactor
• Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
• A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
• Three (3) E-rated current-limiting power fuses
• Three (3) current transformers
• Control power transformer with primary and secondary fuses
• Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
• IntelliVAC™ control module for each vacuum contactor, mounted
in low voltage panel, with advanced features:
• Additional low voltage control panel accessories including:
– “NORMAL-OFF-TEST” circuit
– receptacle for external test power supply
400 Amp – set of control circuit terminal blocks
• 2-high structure design for two complete transformer controllers
• Available in optional ArcShield enclosure
• Also available as “Prepared Space” (Bulletin 1512BP) or Starter Kit
(Bulletin 1512BU)

Specifications

Power Circuit Schematic – 1512BT

30 Visit our Web site: www.ab.com.catalogs


Bulletin 1522E/F/G
Medium Voltage Controller – Two-Speed Non-Reversing Starter

Description of Features
• Fixed mounted vacuum contactor
• HIGH and LOW speed settings for two-speed separate winding,
Bulletin 1522E starter
• HIGH/LOW speeds and HIGH SPEED SHORTING settings for
two-speed consequent pole, Bulletin 1522F/G starter
• Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
• A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
• Three (3) R-rated current-limiting power fuses
• Six (6) current transformers
• Control power transformer with primary and secondary fuses
• Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
400 A • IntelliVAC™ control module for each vacuum contactor, mounted
in low voltage panel, with advanced features:
• Additional low voltage control panel accessories including:
– “NORMAL-OFF-TEST” circuit
– receptacle for external test power supply
– set of control circuit terminal blocks
• Constant or variable torque, and constant horsepower applications

Specifications

Power Circuit Schematic – 1522E

Power Circuit Schematic – 1522F

Visit our Web site: www.ab.com.catalogs 31


Bulletin 1560E / 1562E
Medium Voltage Controller – SMC Flex™ Smart Motor Control Starter

Metering
• Access locally using the controller’s built-in LCD display, or
remotely through the communication port
• Three-phase voltage
• Three-phase current
• Three-phase power (MW, MWh, power factor)
• Elapsed time
• Motor thermal capacity usage
• Motor speed (with optional use of tachometer input)

Diagnostics
• Line Fault • Undervoltage
• Power Loss • Jam
• Voltage Unbalance • Overtemperature
• Current Unbalance • Stall
• Ground Fault • Open Gate
• Communication Fault • Overload
• Phase Reversal • Underload
• Extensive Starts per hour
Bulletin 1562E
Combination Controller Communication (optional)
• DeviceNet™
• ControlNet™
• EtherNet/IP
Description of Features • Profibus DP
• Remote I/O
• RS485-DF1
Optimized Performance, Safety, Convenience
and Reliability Programming
The Rockwell Automation MV SMC Flex Smart Motor Controller • Three-level menu structure (using standard languages)
offers: • Built-in LCD display and keypad
• Multiple languages: English, French, German, Italian, Mandarin,
Portuguese, Spanish
Standard Control Module
• Optional Human Interface Modules (DPI-based)
• Soft Start – with Selectable Kickstart • Configurable with DriveTools™ programming software
• Soft Stop
• Current Limit Start – with Selectable Kickstart
• Linear Speed Acceleration* – with Selectable Kickstart Vacuum Contactor
• Linear Speed Deceleration* • Fixed mounted vacuum contactor is standard
• Dual Ramp – with Selectable Kickstart • Main contactor for unit isolation (1562E)
• Full Voltage • Bypass contactor removes SCR Power Stack from circuit, once at
• Preset Slow Speed full voltage
* requires motor tachometer – Eliminates heat generated by SCRs - improves efficiency
– Protects SCRs from voltage and current transients
• Contactor can be provided with IntelliVAC™ solid-state control
Optional Control Module
• Pump Control (eliminates water hammer) Complete Package
– separate start and stop profiles • Quick shipment of several standard configurations
– Bulletin 1560E retrofit controller (does not include isolation
Motor Protection switch, main contactor, power fuses and control transformer)
– Bulletin 1562E combination controller
• Electronic motor overload protection Class 10, 15, 20 and 30 or
• Available with optional equipment
OFF
• Ready for immediate installation
• Complete installation documentation
• Built to Rockwell Automation quality standards and ISO9001:2000
• Fully load tested with a three-phase MV motor

32 Visit our Web site: www.ab.com.catalogs


Bulletin 1560E / 1562E
Medium Voltage Controller – SMC Flex™ Smart Motor Control Starter

Specifications

Visit our Web site: www.ab.com.catalogs 33


Bulletin 1560E / 1562E
Medium Voltage Controller – SMC Flex™ Smart Motor Control

Power Circuit Schematic – 1560E

Power Circuit Schematic – 1562E

34 Visit our Web site: www.ab.com.catalogs


Bulletin 1572/1576
Medium Voltage Controller – Reduced Voltage Autotransformer Starter

Description of Features
• Fixed mounted vacuum contactor
• (1S, FORWARD, REVERSE and RUN) settings, with closed
transition operation, Bulletin 1576 Reversing starter
• (1S, 2S and RUN) settings, with closed transition operation,
Bulletin 1572 Non-reversing starter
• Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
• A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
• Three (3) R-rated current-limiting power fuses
• Three (3) current transformers
• Control power transformer with primary and secondary fuses
• Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
400 Amp
• IntelliVAC™ control module for each vacuum contactor, mounted
in low voltage panel, with advanced features:
• Additional low voltage control panel accessories including:
– “NORMAL-OFF-TEST” circuit
– receptacle for external test power supply
– set of control circuit terminal blocks
• NEMA medium duty, dry type, three (3) winding autotransformer
with 50, 65 and 80% taps. The 65% tap shall be used unless
otherwise specified.

Specifications

Visit our Web site: www.ab.com.catalogs 35


Bulletin 1572/1576
Medium Voltage Controller – Reduced Voltage Autotransformer Starter

Power Circuit Schematic – 1572

Power Circuit Schematic – 1576

36 Visit our Web site: www.ab.com.catalogs


Bulletin 1582
Medium Voltage Controller – Reduced Voltage Reactor, Non-reversing Starter

Description of Features
• Fixed mounted vacuum contactors (START and RUN) with closed
transition operation
• Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
• A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
• Three (3) R-rated current-limiting power fuses
• Three (3) current transformers
• Control power transformer with primary and secondary fuses
• Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
• IntelliVAC™ control module for each vacuum contactor, mounted
in low voltage panel, with advanced features:
• Additional low voltage control panel accessories including:
– “NORMAL-OFF-TEST” circuit
– receptacle for external test power supply
– set of control circuit terminal blocks
• NEMA medium duty, dry type, three (3) winding reactor with 50,
65 and 80% taps. The 65% tap shall be used unless otherwise
specified.

Specifications

Power Circuit Schematic – 1582

Visit our Web site: www.ab.com.catalogs 37


Bulletin 1591A/B
Medium Voltage Incoming Line Units

1591A

Description of Features (1591A) Description of Features (1591B)


• Incoming bus arrangement for top or bottom cables • Incoming bus arrangement for top or bottom incoming cables
• Provision for low voltage panel and door • Provisions for the low voltage panel and door
• Lug pad with provision for incoming cable lug terminations • Lug pad with provision for incoming cable lug terminations
• Comes as a 2-high structure

Specifications

Note: A 44-inch incomer is only available when a 3000A power bus is used.

Power Circuit Schematic – 1591A/1591B

38 Visit our Web site: www.ab.com.catalogs


Bulletin 1592BF/M, 1594F/M
Medium Voltage Feeders – Fused and Non-Fused Load-Break Switch

Description of Features
• Main load break switch for switching primary power source
• Feeder load break switch for switching other loads
• Isolation between upper and lower power cells
• The operating handle is fully interlocked with the power cell door
• Provisions on the operating handle for key interlocking
• A polycarbonate viewing window in the power cell door to view the
position of the isolation handle
• Protective guard over the line terminals, inside the power cell, to
barrier off medium voltage when the power door is open
• Feeders for 2-high structures
• Bulletin 1592BF – fused load break switch, designed as a feeder
for 2-high structures
• Bulletin 1592F/M – fused load break switch, designed for feeder
and mains
• Bulletin 1594F/M – non-fused load break switch, designed for
feeder and mains

Specifications – 1592BF

Specifications – 1592F/M / 1594F/M

Visit our Web site: www.ab.com.catalogs 39


Bulletin 1592BF/F/M, 1594F/M
Medium Voltage Feeders – Fused and Non-fused Load-break Switch

Power Circuit Schematic – 1592BF/F

Power Circuit Schematic – 1592M

Power Circuit Schematic – 1594F

Power Circuit Schematic – 1594M

40 Visit our Web site: www.ab.com.catalogs


Bulletin 1906B/1912B
Medium Voltage Controller – Brush-Type Synchronous Starter

Description of Features
• Fixed mounted vacuum contactor for Non-reversing Bulletin 1912B
• Fixed mounted vacuum contactors (FORWARD and REVERSE)
for reversing Bulletin 1906B
• For constant speed applications
• Available with or without static exciter
• Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
• A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
• Three (3) R-rated current-limiting power fuses
• Three (3) current transformers
• Control power transformer with primary and secondary fuses
• Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
• IntelliVAC™ control module for each vacuum contactor, mounted
in low voltage panel, with advanced features:
• Additional low voltage control panel accessories including:
– control circuit fusing
– “NORMAL-OFF-TEST” circuit
– receptacle for external test power supply
– set of control circuit terminal blocks
• Synchronous control package:
– Field application and protection relay (SyncPro standard)
– Field application control pilot relays
– Field excitation switch (2-pole contactor standard, when optional
Exciter is not provided as part of the unit)
– Field discharge resistor bank

Specifications – 1906B

Specifications – 1912B

Visit our Web site: www.ab.com.catalogs 41


Bulletin 1906B/1912B
Medium Voltage Controller – Brush-Type Synchronous Starter

Power Control Schematic – 1906B

Power Control Schematic – 1912B

42 Visit our Web site: www.ab.com.catalogs


Bulletin 1906L/1912L
Medium Voltage Controller – Brushless Synchronous Starter

Description of Features
• Fixed mounted vacuum contactor for Non-reversing Bulletin 1912L
• Fixed mounted vacuum contactors (FORWARD and REVERSE)
for reversing Bulletin 1906L
• For constant speed applications
• Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
• A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
• Three (3) R-rated current-limiting power fuses
• Three (3) current transformers
• Control power transformer with primary and secondary fuses
• Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
• IntelliVAC™ control module for each vacuum contactor, mounted
in low voltage panel, with advanced features:
• Additional low voltage control panel accessories including:
– control circuit fusing
– “NORMAL-OFF-TEST” circuit
– receptacle for external test power supply
– set of control circuit terminal blocks
• Provisions for optional factory or customer supplied field exciter
(contact Cambridge to ensure low voltage panel space is available
for customer supplied field exciter.)

Specifications – 1906L

Specifications – 1912L

Visit our Web site: www.ab.com.catalogs 43


Bulletin 1906L/1912L
Medium Voltage Controller – Brushless Synchronous Starter

Power Control Schematic – 1912L

Power Control Schematic – 1906L

44 Visit our Web site: www.ab.com.catalogs


Bulletin 1901
Synchronous Control Package – SyncPro™

Protection/Control
• Squirrel-cage winding protection
• Field winding application control
• Incomplete sequence
• Field voltage failure
• Auto load
• Stall protection
• Pull-out protection (power factor)
• Restart lockout

Display/Metering
• Detected fault conditions
• Slip frequency and starting time during start-up
• Power factor
• Enter/view setpoints through the DTAM

Description of Features

The Bulletin 1901 SyncPro™ is a programmable field application and


protection system for squirrel-cage, brush-type synchronous motors.

The SyncPro system is designed to provide supervisory protection


and field control to a brush-type synchronous motor controller,
proper field application timing, squirrel-cage protection against
long acceleration and stall conditions, as well as running pull-out
protection by monitoring motor power factor. When combined with
a suitable induction motor overload protection relay, the SyncPro
provides the necessary protection for the brush-type synchronous
motor.

Designed for Safety, Convenience and Reliability


• Programmable motor parameters and setpoints
• Wide range of settings for greater user flexibility
• Monitors field contactor coil condition
• Stores data from last 10 trips
• Digital user interface with a high visibility two-line back-lit display
• Displays trip and alarm conditions
• Terminal block assembly for simple interwiring
• Modular concept
• Ideal for retrofit applications
• Suitable for low voltage and medium voltage slip ring synchronous
motor applications
• Self diagnostics

Visit our Web site: www.ab.com.catalogs 45


Bulletin 1901
Synchronous Control Package – SyncPro™

Specifications
Approximate Dimensions
(1901-AND, Open Type)

18.02 [458]
.38 [10]
16.75 [425]

20.00 18.95
[508] [481]

13.29
[338]

6.12
.63 [16] 13.75
13.75 [349]
[349] .36 [9] dia. [155]
(4) Mounting Holes

Front View Side View

Note: Dimensions are in inches [millimeters].

DTAM Dimensions 5.5 (139.7)


2.5
(63.2)

I O B PRE LEN 6.0 (152.4)


7 8 9 NEXT INC

T C R ACC POS
4 5 6 DEC
PREV

N M . I
1 2 3 ± F( )

ESC
:
0 SHIFT ENTER

Front View Side View

Note: A ten-foot cable is provided.

46 Visit our Web site: www.ab.com.catalogs


825-P MODULAR PROTECTION SYSTEM

The Bulletin 825-P Modular Protection System for


motors offers a compact, modular design that
uniquely allows an installer to configure a
device’s functional capabilities to match the Basic
application requirements. Flexibility is also Unit
afforded by accommodating future expansion of
the system as the application requirements grow.
Ease of installation is provide through pluggable
options and accessories. Finally, this next
generation design offers greater capabilities with
the option of full metering for line voltage and
power monitoring in addition to expanded
RTD monitoring. Converter
Modules

Option
Cards

RTD Scanner
Module

Core Balance
Current
Transformer

47
SUPPORT AND MAINTAIN YOUR INVESTMENT
You can maximize the life of your investment by aligning your Medium Voltage solutions with a strategic
approach to maintenance. By including the right combination of predictive, preventive and reactive methods
and Rockwell Automation® Services & Support, you can get the most out of your automation assets.

Protect Your Condition Monitoring


System Control maintenance needs by leveraging technology and predictive expertise

Remote Monitoring & Diagnostics


Communicate and access information locally or through remote support center
Improve
Efficiency
Asset Management
Products and services which maximize the efficiency of your storeroom

Start-U
Up & Commissioning
Decrease Installation and continuous support for your motor control applications
Time To Install

Training
Instructors and self paced materials for troubleshooting and programming

Ease
Troubleshooting Network Validation
DeviceNet™ configuration and diagnostics for networked products

Technical Support
For stand alone products and integrated systems
Reduce Costs

Repair & Renewal Parts


Remanufacturing, exchange services and renewal parts

For More Information


For more information about Rockwell Automation® Services and Support go to
www.rockwellautomation.com/services. To learn which other Rockwell Automation Services
and Support will be most beneficial to your maintenance strategy, contact your local
authorized Allen-Bradley distributor or Rockwell Automation sales office.

Allen-Bradley, ArmorStart, Compact I/O, DeviceLogix, DriveLogix, FORCE Technology, IntelliCENTER, PowerFlex, Rockwell Automation, SMC-Flex, SynchLink and XM
are trademarks of Rockwell Automation. Trademarks not belonging to Rockwell Automation are proerty of their respective companies.

Medium Voltage Products, 135 Dundas Street, Cambridge, ON, N1R 5X1 Canada, Tel: (1) 519.740.4100, Fax: (1) 519.623.8930, www.ab.com/mvb

Publication 1500-SG001A-EN-P - September 2006 Copyright © 2006 Rockwell Automation, Inc. All rights reserved. Printed in Canada

You might also like