0% found this document useful (0 votes)
1K views3 pages

Basic Seismic Force Resisting System

The document describes various structural systems for concrete and steel buildings and provides limitations on building height based on the seismic zone. For concrete systems, bearing wall, frame, moment frame, dual, and cantilevered column systems are outlined. Height limits range from 10 to no limit (NL) depending on the system and zone. For steel systems, bearing wall, braced frame, moment frame, and dual systems are described. Height limits range from 20 to no limit depending on the specifics of the structural system and seismic zone (2 or 4).

Uploaded by

lakr lama
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views3 pages

Basic Seismic Force Resisting System

The document describes various structural systems for concrete and steel buildings and provides limitations on building height based on the seismic zone. For concrete systems, bearing wall, frame, moment frame, dual, and cantilevered column systems are outlined. Height limits range from 10 to no limit (NL) depending on the system and zone. For steel systems, bearing wall, braced frame, moment frame, and dual systems are described. Height limits range from 20 to no limit depending on the specifics of the structural system and seismic zone (2 or 4).

Uploaded by

lakr lama
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3

TABLE 208-11A EARTHQUAKE FORCE RESISTING STRUCTURAL SYSTEMS OF CONCRETE

SYSTEM LIMITATION AND BUILDING


BASIC SEISMIC FORCE RESISTING HEIGHT LIMITATION BY SEISMIC ZONE, m
r Ω
SYSTEM
zone 2 zone 4
A. BEARING WALL SYSTEMS
SPECIAL REINFORCED CONCRETE SHEAR
NL 50
WALLS 4.5 2.8
ORDINARY REINFORCED CONCRETE SHEAR
4.5 NL NP
WALLS 2.8
B. BUILDING FRAME SYSTEM
SPECIAL REINFORCED CONCRETE SHEAR
WALLS OR BRACED FRAMES 5 2.8 NL 75

ORDINARY REINFORCED CONCRETE SHEAR


WALLS OR BRACED FRAMES 5.6 NL NP
2.2
INTERMEDIATE PRECAST SHEAR WALLS OR
5 2.8 NL
BRACED FRAME
C. MOMENT RESISTING FRAME SYSTEMS
SPECIAL REINFORCED CONCRETE MOMENT
8.5 NL NL
FRAMES 2.8
INTERMEDIATE REINFORCED CONCRETE
5.5 NL NP
MOMENT FRAMES 2.8
ORDINARY REINFORCED CONCRETE FRAMES 3.5 2.8 NL NP
D. DUAL SYSTEMS
SPECIAL REINFORCED CONCRETE SHEAR 8.5
NL
WALLS 2.8
ORDINARY REINFORCED CONCRETE SHEAR 6.5
NL NP
WALLS 2.8
E. DUAL SYSTEMS WITH INTERMEDIATE
MOMENT FRAMES
SPECIAL REINFORCED CONCRETE SHEAR 6.5
NL 50
WALLS 2.8
ORDINARY REINFORCED CONCRETE SHEAR 5.5
NL 50
WALLS 2.8
SHEAR WALL FRAME WITH INTERACTIVE 2.8
SYSTEM WITH ORDINARY REINFORCED
4.2 NP NP
MOMENT FRAMES AND REINFORCED
CONCRETE SHEAR WALLS
F. CANTILEVERED COLUMN BUILDING
SYSTEMS
CANTILEVERED COLUMN ELEMENTS 2.2 2 NL 10
G. SHEAR WALL FRAME INTERACTION
5.5 NL 50
SYSTEM 2.8
TABLE 208-11B EARTHQUAKE FORCE RESISTING STRUCTURAL SYSTEMS OF STEEL

SYSTEM LIMITATION AND BUILDING HEIGHT


BASIC SEISMIC FORCE RESISTING LIMITATION BY SEISMIC ZONE, m
r Ω
SYSTEM
zone 2 zone 4
A. BEARING WALL SYSTEM

LIGHT STEEL FRAMED BEARING WALLS WITH TENSION


2.8 2.2 NL 20
ONLY BRACING

BRACED FRAMES WHERE BRACING CARRIES GRAVITY


4.4 2.2 NL 50
LOAD

LIGHT FRAMED WALS SHEATHED WITH WOOD


STRUCTURAL PANELS RATED FOR SHEAR RESISTANCE 5.5 2.8 NL 20
OR STEEL SHEETS

LIGHT-FRAMED WALL S WITH SHEAR PANELS OF ALL


4.5 2.8 NL 20
OTHER LIGHT MATERIALS

LIGHT FRAMED WALL SYSTEMS USING FLAT STRAP


2.8 2.2 NL NP
BRACING

B. BUILDING FRAME SYSTEMS


STEEL ECCENTRICALLY BRACED FRAMES (EBF)
MOMENT-RESISTING CONNECTIONS AT COLUMNS 8 2.8 NL 30
AWAY FROM LINKS
STEEL ECCENTRICALLY BRACED FRAMES (EBF) NON
MOMENT-RESISTING CONNECTIONS AT COLUMNS 6 2.2 NL 30
AWAY FROM LINKS
SPECIAL CONCETRICALLY BRACED FRAMES (SCBF) 6 2.2 NL 30
ORDINARY CONCETRICALLY BRACED FRAMES (OCBF) 3.2 2.2 NL NP

LIGHT FRAMED WALS SHEATHED WITH WOOD


6.5 2.8 NL 20
STRUCTURAL PANELS/ SHEET STEEL PANELS

LIGHT-FRAMED WALL S WITH SHEAR PANELS OF ALL


2.5 2.8 NL NP
OTHER LIGHT MATERIALS

BUCKLING RESTRAINED BRACED FRAMES (BRBD) NON


7 2.8 NL 30
MOMENT RESISTING BEAM COLUMN CONNECTION

BUCKLING RESTRAINED BRACED FRAMES (BRBD)


8 2.8 NL 30
MOMENT RESISTING BEAM COLUMN CONNECTION

SPECIAL STEEL PLATE SHEAR WALLS ( SPSW) 7 2.8 NL 30


C. MOMENT RESISTING FRAME SYSTEM
SPECIAL MOMENT RESISTING FRAME (SMRF) 8 3 NL NL

INTERMEDIATE STEEL MOMENT FRAME (IMF) 4.5 3 NL NP

ORDINARY MOMENT FRAMES (OMF) 3.5 3 NL NP

SPECIAL TRUSS MOMENT FRAMES (STMF) 6.5 3 NL NP

SPECIAL COMPOSITE STEEL AND CONCRETE MOMENT 8 3 NL NL


FRAMES
INTERMEDIATE COMPOSITE MOMENT FRAME 5 3 NL NP

COMPOSITE PARTIALLY RESTRAINED MOMENT FRAMES 6 3 50 NP

ORDINARY COMPOSITE MOMENT FRAMES 3 3 NP NP

D. DUAL SYSTEMS WITH SPECIAL MOMENT FRAMES


STEEL ECCENTRICALLY BRACED FRAMES 8 2.8 NL NL

SPECIAL STEEL CONCENTRICALLY BRACED FRAMES 7 2.8 NL NL

COMPOSITE STEEL AND CONCRETE ECCENTRICALLY


8 2.8 NL NL
BRACED FRAME