Heat Shrink Terminations For Use On XLPE and Paper Cables 1.9/3.6kV

This document provides information on heat shrink terminations for cables. It lists various part numbers for single core and 3 core heat shrink terminations for XLPE and PILC cables rated for 1.9/3.6kV and 0.6/1kV. Red anti-track materials are recommended for use in high humidity, chemical, and dust conditions. Tables show the part numbers, applicable cable ranges, and tail lengths for indoor and outdoor applications. Notes provide additional details on earthing components and part numbering.

Uploaded by

hkaruvathil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
64 views1 page

Heat Shrink Terminations For Use On XLPE and Paper Cables 1.9/3.6kV

This document provides information on heat shrink terminations for cables. It lists various part numbers for single core and 3 core heat shrink terminations for XLPE and PILC cables rated for 1.9/3.6kV and 0.6/1kV. Red anti-track materials are recommended for use in high humidity, chemical, and dust conditions. Tables show the part numbers, applicable cable ranges, and tail lengths for indoor and outdoor applications. Notes provide additional details on earthing components and part numbering.

Uploaded by

hkaruvathil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Unit E3, Crown Way, Crown Park Industrial Estate, Rushden, Northants, UK, NN10 6FD

Tel: +44 (0)1933 356758 Fax: +44 (0)1933 413821 Email: [email protected]
Skype: shrinkpolymersystems www.shrinkpolymersystems.co.uk

Heat Shrink Terminations for use on XLPE and Paper


Cables 1.9/3.6kV
In conditions of high humidity, chemical and dust contamination, it is recommended that red anti-track materials
are used for extra reliability and long term service.

Single Core PILC / XLPE Indoor / Outdoor Type


Part Number Cable Range Tail Length
1TIS-3.6A 25-70mm² 300mm
1TIS-3.6B 95-300mm² 300mm
1TIS-3.6C 400-630mm² 300mm

3 Core PILC / XLPE Indoor / Outdoor Type


Part Number Cable Range Tail Length
3TIS-3.6A 25-70mm² 600mm
3TIS-3.6B 95-185mm² 600mm
3TIS-3.6C 240-400mm² 600mm

Heat Shrink Terminations for LV


PILC Cables 0.6/1kV
3/4 Core PILC Termination Lug
Seals
Part Number Cable Range Tail Length
SPS 4-35-600-3 4-35mm² 600mm
Core
SPS 4-35-1000-3 4-35mm² 1000mm Tubes
SPS 50-150-600-3 50-150mm² 600mm
SPS 50-150-1000-3 50-150mm² 1000mm
SPS 185-300-600-3 185-300mm² 600mm
SPS 185-300-1000-3 185-300mm² 1000mm Cable
Breakout

Table above lists part number for 3 core kits, if 4 core, last digit Option of
should read - 4 Earth Kit for
Lead/Armours
Example: SPS 50-150-600-4 on Outdoor
Applications

Note: Picture shows outdoor earthing components. If indoor


type, the gland kit selected normally takes care of the Shrink
Tube
earthing requirements.