Unity Pro V 8.

What’s
new
Due to possible changes in standards and equipment, the features described in this
document in the form of text and images are subject to confirmation by Schneider Electric.
© Copyright Schneider Electric 2014. All rights reserved.
Publication & Design: Schneider Electric
New features at a glance
Unity Pro
V8.1
● Support M580 evolutions
● BMENOC
● Weighing module Premium ISPY101
● Device Integration improvements
● DTM improvements for devices on HART & PRM
● Altivar Process ATV600 integration
● References
● Access a variable from it’s location adresss
(compliance with IEC1131-3)
● Implicit Conversion
● Make design more simple
● Cybersecurity on M340 & Premium
● Application password & FTP/HTTP control
● Concept ProWORKS converter
● Improvements and bug fixes
● Registration : Unity V8.1 is an update of V8
● Supported OS
● Windows 7, Windows 8.1, Windows Server 2008
Schneider Electric - Industry – Plant Solution Control - Sept 29th 2014
● Documentation updates
4
Modicon M580 platform
Unity Pro
V8.1
● M580 : support new BME NOC 0301 (Generic) & BME NOC 0311 (Factory
Cast)
● Support Weighing module Premium ISPY101

Schneider Electric - Industry – Plant Solution Control - Sept 29th 2014 5


Device Integration
Unity Pro
V8.1
● DTM improvement for devices on HART and PRM : a simplified user interface to
set the Ethernet parameters (IP@, DHCP…).

(yet available on V8.0 :


HotFix UnityPro_V80_HF_DTM)

● Altivar Process ATV6xx integration


ATV6xx Drives can be easily configured and
managed in Unity Pro V8.1

(yet available on V8.0 )


ATV Process DFB and DTM are available on SE.com

Schneider Electric - Industry – Plant Solution Control - Sept 29th 2014 6


Mapped element in DDT : References
Unity Pro
V8.1
• DDT (structures) can now support variables coming from
different data areas…
- Mapped data (on %MW, %I, %Q…)
- unlocated data (existing variables in the application)

• …thanks to REFERENCES (as defined in IEC1131-3 3rd ed)


- Eg : REF (MyVariable) = the address of MyVariable
MyMotor <Struct>
|_ Start REF_TO EBOOL
|_ FeedBack REF_TO EBOOL
|_ Speed REF_TO INT

Instances : value
MyMotor1
|_ Start REF_TO EBOOL REF(%Q1.1.1)
1 |_ FeedBack REF_TO EBOOL REF(%I1.2.1)
|_ Speed REF_TO INT REF(%MW100) or
REF(MyVar)

Syntax :
(MyMotor1.start)^ %Q1.1.1

Schneider Electric - Industry – Plant Solution Control - Sept 29th 2014 7


References : how it works
Create DDT type Unity Pro
V8.1
Create instances (of DDT)
& set an initial value

Or create variable (EDT) & set an


initial value

In animation table or program


editor, REF^ allows to access
the referenced variable

Schneider Electric - Industry – Plant Solution Control - Sept 29th 2014 8


Implicit Type conversion (1/2)
Unity Pro
Make your design more simple V8.1

• Unity Pro implements


• As proposed by IEC1131-3 3rd : Source Data REA
Target Data Type
UDIN DWOR WOR BYT BOO
• 11 implicit conversions Type L DINT INT T UINT D D E L

real
i (5 mathematic calculation REAL
# i i i i e e e -
(IEC)
& 6 conversions on bits) i # i i i i i i -

integer
DINT
i i
INT (IEC) (IEC)
# i i i i i -

• And go further : Convert


unsigned

UDINT i i i # i i i i -
i i i
automatically after calculation when UINT (IEC) (IEC) i (IEC)
# i i i -

range fit the new type. DWOR


e i i i i # i i -
D
i Rise a default if conversion e i i i i
i
# i -
WORD (IEC)
bit

issue, range not matching e i i i i


i i
# -
BYTE (IEC) (IEC)
i i i
BOOL
e i i i i (IEC) (IEC) (IEC)
#

Schneider Electric - Industry – Plant Solution Control - Sept 29th 2014 9


Implicit Type conversion (2/2)
Unity Pro
V8.1

Target Data Type


Source Data REA UDIN DWOR WOR BYT BOO
Type L DINT INT T UINT D D E L
real

REAL
# i i i i e e e -

i # i i i i i i -
integer

DINT
i i
INT (IEC) (IEC)
# i i i i i -
unsigned

UDINT i i i # i i i i -
i i i
UINT (IEC) (IEC) i (IEC)
# i i i -
DWO
RD
e i i i i # i i -
WOR i
D
e i i i i (IEC)
# i -
bit

i i
BYTE
e i i i i (IEC) (IEC)
# -
i i i
BOOL
e i i i i (IEC) (IEC) (IEC)
#

Schneider Electric - Industry – Plant Solution Control - Sept 29th 2014 10


Cybersecurity on M340 & Premium
Unity Pro
V8.1
• Application running in the PLC is now better protected by
password

• Improved Access controls :


Easy and more secure setting of
FTP & HTTP access controls

Schneider Electric - Industry – Plant Solution Control - Sept 29th 2014 11


Concept & ProWORKS converter
Unity Pro
V8.1
• Concept and ProWORKS converter has been enhanced to fix
several issues reported in the field and implements some
enhancements (useless 6X registers no more created, …)

Schneider Electric - Industry – Plant Solution Control - Sept 29th 2014 12


Registration policy
Unity Pro
V8.1
● Unity Pro V8.1 is proposed as an update of Unity Pro V8.0
● 3 new part numbers are created
UNYSPUUPDSCD81 Update Unity Pro S V8.1
UNYSPUUPDLCD81 Update Unity Pro L V8.1
UNYSPUUPDECD81 Update Unity Pro XL V8.1

● It is mandatory to have a valid Unity Pro V8.0 license

● Use case 1 : Customer has yet Unity Pro V8.0 version


●Purchase UNYSPUUPDyCD81 (same size S,L,XL as registered version)
●Install UNYSPUUPDyCD81
● Use case 2 : New customer
●Purchase Unity Pro v8.0
●Purchase Unity Pro v8.1 (same size S,L,XL as v8.0)
●Install Unity Pro v8.1 and register using PN/SN of the CD80 product

Schneider Electric - Industry – Plant Solution Control - Sept 29th 2014 13


Supported Operating Systems
Unity Pro
V8.1
Unity Pro supports:
- Windows Seven 32 & 64 bits
- Windows 8.1 32 & 64 bits (in Windows 7 compatibility mode).
- Windows Server 2008 for a flexible server architecture

Note :
•Windows XP is no more supported
• Windows 8.0 is no more supported (replaced by
8.1)

Schneider Electric - Industry – Plant Solution Control - Sept 29th 2014 14


Unity Companions & documentation
Unity Pro
V8.1

● Unity Loader V8.1


Available through download only (on schneider-electric.com)
● EFB Toolkit 8.0 Service Pack 1
available to download on schneider-electric.com
Service Pack 1 is an update EFB Toolkit V8.0 version.
No registration is required for this update.
● Unity DIF V8.0
(no evolution)

● Unity Pro documentation (pdf format) is no more available as DVD in


Unity Pro package.
●Download from Schneider-Electric.com

Schneider Electric - Industry – Plant Solution Control - Sept 29th 2014 15