This document provides the design of footings for two interior columns. Key details include: - Footing 1 is a strap footing with dimensions of 2.5m x 2.66m. Reinforcement is designed for shear and moment capacities. - Footing 2 is a square footing with side length of 2.58m. Punching shear governs the design. - Shrinkage and temperature reinforcement is designed for Footing 1. - A strap beam is designed connecting the two footings to resist shear and moment demands. Reinforcement ratios and bar sizes are calculated and specified.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
169 views8 pages

Chapter 10 Final

This document provides the design of footings for two interior columns. Key details include: - Footing 1 is a strap footing with dimensions of 2.5m x 2.66m. Reinforcement is designed for shear and moment capacities. - Footing 2 is a square footing with side length of 2.58m. Punching shear governs the design. - Shrinkage and temperature reinforcement is designed for Footing 1. - A strap beam is designed connecting the two footings to resist shear and moment demands. Reinforcement ratios and bar sizes are calculated and specified.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 8

CHAPTER 10

DESIGN OF
FOOTINGS

138 | R e i n f o r c e d C o n c r e t e
Foundation Plan

INTERIOR –INTERIOR (strap footing)

139 | R e i n f o r c e d C o n c r e t e
GIVEN (ASSUME): A2= 6.66 m2
A1 = 9.06 m2
qa = 140 kPa f’c = 28 MPa
𝛾𝑐 = 23.6 kN/m3 𝛾𝑠 = 18 kN/m3 [A1 = L1 x B1]
Df = 2.3 m 6.66 = 2.5B1
B1 = 2.66 m
25 mm ∅ RSB (strap) fy = 414 MPa
25 mm ∅ RSB (main) fy = 414 MPa [A2 = L2 x B2]
16 mm ∅ RSB (temp.) fy = 276 MPa Using square footing, L2 = B2
6.66 = (L2)2
L2 = B2 = 2.58 m
Column 1 Column 2
400 mm x 400 mm 400 mm x 400 mm Design of Footing:
PDL = 520.38kN PDL = 643.27 kN P1 = 520.38 + 126.04 = 646.42 kN x1
PLL = 126.04 kN PLL = 126.5 kN = 0.2 m
P2 = 643.27 + 126.5 = 769.77 kN x2
SOLUTION: = 5.2 m

qe = 140 – 18(2.3) = 98.6 kPa Pu1 = 1.2 (520.38) + 1.6 (126.04 )= 826.12 kN
Pu2 = 1.2 (643.27) + 1.6 (126.5 ) = 974.32 kN
assume qe = 90 kPa
Pu = 826.12 + 974.32 = 1800.44 kN
P1 = 520.38 + 126.04 = 646.42 kN x1 = 0.2 m
P2 = 643.27 + 126.5 = 769.77 kN x2 = 5.2 m Afooting = A1 + A2
Afooting = 2.5(2.66) + (2.58)2 = 13.31 m2
P = P1 + P2
P = 646.42 + 769.77 = 1416.19 kN 𝑃𝑢
qu = 𝐴𝑓𝑜𝑜𝑡𝑖𝑛𝑔 =
1800.44
= 135.27 kPa = 0.13527
13.31
MPa
PXg = P1x1 + P2x2
1416.19 (Xg) = 646.42 (0.2) + 769.77 (5.2)
FOOTING 1:
Xg = 2.92 m

𝑃 1416.19 solving d from wide-beam shear


Area of footing = 𝑞𝑒 = 90
= 15.74 m2
Assume width of strap = 550 mm (larger
Area of footing = A1 + A2 = 15.74 m2 than column)
eq.1

Try L1 = 2.5 m

A(Xg) = A1(x1/2) +A2x2


15.74 (2.92) = A1 (2.5/2) + A2 (5.2)
A1 (2.5/2) = 15.74 (2.92) - A2 (5.2)
A1 = 36.77– 4.16 A2 eq.2

Substitute A1 in eq. 2 to eq. 1:

(36.77 – 4.16A2) + A2 = 15.74

140 | R e i n f o r c e d C o n c r e t e
Vu = qu x Ashaded [Vu = ∅Vc]
Vu = 0.13527 (2500) (1055 - d) 974.32 x103 - 0.13527 (400 + d)2
Vu = 338.18 (1055 - d) = 0.75 [7.20 (400d + d2)]
d = 257.81 mm “say” 260 mm
Vc = 0.17𝜆√𝑓′𝑐 bwd
Vc = 0.17 (1) √28 (2500) d check for actual qe:
Vc = 2248.89d
hc = 260 + 0.5(25) + 75
[Vu = ∅Vc] hc = 347.5 mm “say” 350 mm
338.18 (1055 - d) = 0.75 (2248.89d)
d = 176.2 “say” 180 mm hs = 2.5 – 0.35 = 2.15 m

check for actual qe: qe = qa-𝛾chc -𝛾shs


qe = 140 - 23.6(0.35) - 18(2.15)
hc = 180 + 0.5(25) + 75 qe = 93.04 kPa > 90 kPa (OK!)
hc = 267.5 mm “say” 270 mm

hs = 2.5–0.27= 2.23 m Section Footin Footing Footing Footing


g 1 1 2 2
qe = qa -𝛾chc -𝛾shs (transv (longitu (transve (longitu
qe = 140 - 23.6(0.27) - 18(2.23) erse) dinal) rse) dinal)
qe = 93.49 kPa > 90 kPa (OK!) Mu, kN – 188.2 198.35 179.77 207.32
m
FOOTING 2: Ru, MPa 2.58 3.45 1.15 1.62
(since footing 2 is a square footing, thus, 𝜌 0.0066 0.00904 0.00285 0.00406
punching shear will govern) 1
Use 𝜌 0.0066 0.00904 0.0034 0.00406
1
As, mm2 2974.5 3727.2 2280.7 2461.6
N 6.06 7.59 4.65 5.01
Use N 7 8 5 6
Location Bottom Bottom Bottom Bottom

Moment:

Vu = Pu2 – qu x Ashaded
Vu = 974.32 x 103 -0.13527 (400 + d)2

Vc = 2 (0.17) 𝜆√𝑓′𝑐 bod


Vc = 2 (0.17) (1) √28 [4(400+d)](d)
Vc = 7.20 (400d + d2)

141 | R e i n f o r c e d C o n c r e t e
Footing 1 (transverse section): Spacing = 300 mm O.C

Mu = 135.27 (2.5) (1.0552/2) Development Length:


Mu = 188.2 kN – m
b = 2500 mm; d = 180 mm 1 𝑓𝑦 𝛹𝑡 𝛹𝑠 𝛹𝑒
Ld = ( 𝑐𝑏+𝐾𝑡𝑟 ) 𝑑𝑏
1.1 𝜆 √𝑓′ 𝑐( )
𝑑𝑏
Footing 1 (longitudinal section):
1 (414)(1)(1)(1)
Ld = ( ) (25) = 711.26 mm
Mu = 135.27 (2.66) (1.052/2) 1.1(1)√28(2.5)
Mu = 198.35 kN – m
b = 2660 mm; d = 180 - 25 = 155 mm
Minimun Ld furnished: 1015 + 550 - 75 =
Footing 2 (transverse section): 1665 mm> 711.26 mm (OK!)

Mu = 135.27 (2.58) (1.0152/2) Design of Strap:


Mu = 179.77 kN – m
b = 2580 mm; d =260 mm

Footing 2 (longitudinal section):

Mu = 135.27 (2.58) (1.092/2)


Mu = 207.32 kN – m
b = 2580 mm; d = 260 – 25 = 235 m

1.4 1.4
𝜌min = = = 0.0034
𝑓𝑦 414

𝜌max = 0.75𝜌b
0.85 (28)(0.85)(600)
𝜌max = 0.75 414 (414+600) = 0.0217

𝜋 (𝑑)2 𝜋
Ab = = (25)2 = 490.87 mm2
4 4 At section A-A:

Shrinkage and temperature bars for Mu = Ru1(1.25) – Pu1 (1.25)


Footing1: Mu = 135.27 (2.5) (2.66) (1.25) – 826.12
(h = 270 mm) (1.25)
Mu = 91.78 kN – m
Using 16 mm bars with fy = 276 Mpa
Vu = Ru1 – Pu1
For b = 1000 mm Vu = 135.27 (2.5) (2.66) – 826.12
Ast = 0.002bh Vu = 73.43 kN
Ast = 0.002 (1000) (270)
Ast = 540 mm2 Depth of beam based on beam shear:

𝜋
[Vu = ∅Vc]
(16)2 (N) = 540; N = 2.9
4
1000
Spacing = = 344.83 mm Vu = ∅(0.17)𝜆√𝑓 ′ 𝑐 bwd; bw = 550 mm
2.9

142 | R e i n f o r c e d C o n c r e t e
73.43 x103 = 0.75 (0.17) (1) √28 (550) d Use d = 200 mm
d = 197.89 mm “say”200 mm
𝑀𝑢 91.78 𝑥106
Ru = ∅𝑏𝑑2 = (0.9)(550)(200)2
Depth of beam based on moment:
Ru = 4.64 MPa
Use 𝜌 = 0.6𝜌b
0.85 (𝑓′𝑐) 2𝑅𝑢
0.85 (28)(0.85)(600) 𝜌= [1 − √1 − ]
𝜌= 0.6 414 (414+600)
= 0.0173 𝑓𝑦 0.85𝑓′𝑐

0.85 (28) 2(4.64)


𝜌 𝑓𝑦 0.0173 (414) 𝜌= [1 − √1 − 0.85(28)] = 0.01259
𝜔= 𝑓′𝑐
= 28
= 0.256 414

As = 𝜌bd
As = 0.01259(550) (200)
Mu = ∅ f’c 𝜔 bd2 (1-0.59 𝜔)
As = 1384.9 mm2
91.78 x106 = 0.9 (28) (0.256) (550) (d)2 (1-
0.59(0.256)) 1384.9
d =174.55 mm “say” 180 mm N= 𝜋 (25)2
= 2.82 “say” 4 bars
4

SQUARE FOOTING

GIVEN: qe = 92.48 kPa

Column 1 Dimension of the footing:


400 × 400mm P 321.29 + 102.11
𝐴𝑓𝑜𝑜𝑡𝑖𝑛𝑔 = = = 4.58 m2
PDL = 321.29 kN 𝑞𝑒 92.48
PLL = 102.11 kN 4.58 mm2 = L × L

qa = 140 kPa 𝛾𝑐 = 23.6 kN/m3 L = 2.14 m


hfooting = 2.5 m 𝛾𝑠 = 18 kN/m3
f’c = 28 MPa fy = 414 MPa Footing dimension= 2.14m x 2.14m

(use 25 mm diameter for main bars)

Initial estimate of footing depth:


(321.29+102.11 )
𝐴𝑓𝑜𝑜𝑡𝑖𝑛𝑔 = L2 =
140
L= 1.74 m ≈ 1740 mm
Depth= 20% (1740) + 75 = 423 mm say
450 mm

Effective soil bearing capacity:


qe = qa –𝛶chc - 𝛶Shs
=140 – 23.6 (0.45) – 18(2.5 – 0.45)

143 | R e i n f o r c e d C o n c r e t e
Based on two-way or punching shear:
Vu = quAshaded
= (0.11986) [(2140)2 -(400+d)2]
= (0.11986)(21402 –160000 - 800d - d2)
Vu = 0.11986 (4419600 - 800d - d2) N

𝑉𝑐 = 2(0.17𝜆√𝑓 ′𝑐𝑏𝑜 𝑑)
Depth of footing: 𝑏𝑜 = 4(400 + 𝑑)
Factored Load = 2(0.17)(1)√28[4(400 + 𝑑)] 𝑑
𝑞𝑢 =
Area of footing 𝑉𝑐 = 7.2 (400𝑑 + 𝑑2 )
1.2(321.29) + 1.6(102.11)
=
2.14(2.14) Vu = ϕ VC
𝑞𝑢 =119.86 kPa = 0.11986 MPa 0.11986 (4419600 - 800d - d2) = 0.75
[7.2 (400𝑑 + 𝑑2 )]
d = 170.72 mm “say” 180 mm

Total depth of footing= 180– 75 – 1.5(25)


Total depth = 67.5 mm< 500 mm (OK!)
Based on wide beam shear:
Vu = quAshaded
Required Steel Area:
= (0.11986) [2140(870– d)]
d = 180 mm
= 256.5(870 – d) N
Mu = (119.86) (.85) (2.14) (1/2)
𝑉𝑐 = 0.17𝜆√𝑓 ′ 𝑐𝑏𝑊 𝑑 = 109.01kN•m
= (0.17)(1)√28(2140)(d)
Mu = ϕ Ru bd2
𝑉𝑐 = 1925.95 𝑑 N
109.01 ˣ 106 = 0.90Ru (2140) (180)2
Ru = 1.75 MPa
[Vu = ϕ VC]
256.5( (870-d) = 0.75 (1925.95𝑑)
d = 131.32 mm

144 | R e i n f o r c e d C o n c r e t e
0.85𝑓′ 𝑐 2𝑅
𝜌= fy
[1 − √1 − 0.85𝑓𝑢 ′𝑐]
0.85(28) 2(1.75)
= [1 − √1 − 0.85(28)]
414
ρ = 0.0044

1.4 1.4
𝜌min = 𝑓𝑦
= 414 = 0.0034

Use ρ = 0.0044
As = ρbd
= (0.0044) (2140) (180)
As = 1694.88 mm2

Number of 25 mm bars:
𝜋
(25)2 (N) = 1694.88 mm2
4
N = 3.45 “say” 4 bars

Development Length:

1 𝑓𝑦 𝛹𝑡 𝛹𝑠 𝛹𝑒
Ld = ( 𝑐𝑏+𝐾𝑡𝑟 ) 𝑑𝑏
1.1 𝜆 √𝑓′ 𝑐( )
𝑑𝑏

1 (414)(1)(1)(1)
Ld = ( 1.1(1) ) (25) = 711.26 mm
√28(2.5)

Minimun Ld furnished: 870 + 400 – 75 = 1195 mm (OK!)