Temperature Loggers
Temperature Loggers
Temperature Loggers
data recorder
up to 8 inputs 0/4 - 20 mA or Pt100/Pt500/Pt1000
2 electronic relay outputs (optoMOS)
USB Host port for flash data storage
RS-485 / Modbus RTU
free configuration and recording software
The MultiLog SRD-99 device is designed to record and An example of what the display looks like
display current values as well as to present technological
parameters in the form of graphs. The device is equipped
with eight temperature (Pt100/500/1000) or current (in the
0/4-20 mA standard) inputs, one pulse (digital) input for
controlling the recording process and one USB Host port
for flash data storage. Internal memory has 2 MB capacity
(0.5 million data recordings altogether) or 8 MB in version
with USB port (2 milions data recordings). However
The history of the process in time The current value of the measurement signal
when a USB flash drive is plugged permanently, it can Height of the digits: 18 mm
significantly extend the recording time without a need of
data transfering from SRD-99 to a PC. For example: 1GB
flash drive allows continuous data recording for over 1 year
(8 channels recorded every 1 sec., approx 250 millions data
recordings)! Individual alphanumeric description (text) of
each of the recorded channels is possible. The multi-
language menu assisted with full text descriptions makes
the unit configuration process quite easy. However, due to a 8-channel view displayed at the same time Logging parameters
significant number of configured parameters it is advised to
use the attached configuration software for PCs.
New in SRD-99 are 2 outputs - electronic relays with max.
load 24V AC (35V DC) 200 mA. Main function of outputs is
a signalisation of critical situations, but thanks to expanded
menu it is possible to use it in numerous control and
regulation applications. Both outputs can be driven by
Device information Main menu of the unit
single measurement channel or by group of channels (from
1 to 8 channels) with individually adjustable thresholds for
every measurement channel. Signalisation of output state is
made as two fields described R1 and R2 in left upper corner Technical data
of LCD screen.
Power supply: 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC, all separated
Power consumption: typical 7 VA; max. 12 VA
- USB Host port for flash data storage and configuration Display: graphic LCD, 128 x 64 points, with backlight
transfer (option), Measuring inputs: 1, 4 or 8; Pt100; Pt500; Pt1000 (2 and 3-conductor connection)
or 0/4-20 mA inputs; common ground
- a legible graphic display 128x64 points, with a backlight, Measuring range: ± 9999 + decimal point (current inputs); -100°C ÷ +600°C (RTD
- current graph of trends for each channel separately, inputs) with resolution 0,1°C
Digital input: 1 input 24V DC, optocoupled
- free configuration and recording software, Outputs: 2 electronic relays (ER1, ER2) with max. load 24V AC (35V DC) / 200 mA
- insulated communication interface RS-485. Sensors supply (only current version): 24 V DC ± 5%, max. 200 mA, not separated
from measuring inputs
Communication interface: RS-485 (Modbus RTU) or USB Host port, galvanically
separated
Ordering Transmission speed: 1200 - 115200 bit/sec.
Internal memory capacity: 2 MB (0.5 million data recordings) in version without USB,
SRD-99-XX28-1-X-XX1 8 MB (above 2 millions data recordings) in version with USB Host port
options: Type of protection:
00 : no options version without USB: IP 65 (front), available options: additional frame IP 65
number 01 : IP 65 frame for panel cut-out sealing, transparent door STD-99, see: accessories
of inputs: version with USB: a) IP 40, b) IP 54 (when fitted with STD-99 transparent
(version without USB)
1 door, see: accessories)
0B : USB Host port provided Working temperature: 0°C ÷ +50°C
4 with a protective cap Storage temperature: -10°C ÷ +70°C
8 0J : portable case P130 Case: board
(front USB Host, Case material: NORYL - GFN2S E1
type of no alarm connectors) Case dimensions: 96 x 96 x 100 mm
inputs: power supply: Panel cut-out dimensions: 90,5 x 90,5 mm
1 : current 0/4-20 mA Installation depth: min. 102 mm
3 : 24V AC/DC
3 : RTD (Pt100, Board thickness: max. 5 mm
4 : 85V - 260V AC/DC
Pt500, Pt1000)
For detailed technical information and manuals for this
product, please contact us at [email protected].
2.1.1.
Software attached with data recorder Extended network applications
1. Loggy Soft We have extended our offer by ethernet applications and just there is no need to place
PC with RS-485/USB converter near the installation. Now it can be installed on any
location where internet is available. Additionally, we have expanded network
functionality of SimCorder application. Now, it allows to upgrade your acquisition
system of network functions based on TCP/IP protocol. This version consists of server,
which collects measurement data from network and records them to database and
clients which communicate to the server and allow watching stored data.
SimCorder
router
converter Server
The Loggy Soft program enables the visualization, Serial/Internet
SimCorder
archiving and printing of measurements (e.g. temperature,
humidity, pressure) stored in SRD-99-type device memory.
Work with SRD-99-type devices takes place through
Client
an RS-485 serial interface or flash-disk devices plugged
into USB port. Connecting a network of units to a serial
port (RS-232) or USB port of a PC is possible thanks Examplary pin assignment
to a converter (RS-485 to RS-232 or RS-485 to USB)
produced by SIMEX.
1 2 4 5 6 7 9 10 11 12 13 14 1 2 4 5 6 7 9 10 11 12 13 14
L N n.c. DATA+ L N n.c. DATA+
DIN- DIN+ DIN- DIN+
2. S-Toolkit 85-260V
ER1 ER2
DATA-
GND-RS
85-260V
ER1 ER2
DATA-
GND-RS
AC digital AC digital
50/60Hz input RS-485 50/60Hz input RS-485
12VA Warning! 12VA
Terminals GND and AGND are not separated. 15 16 17 18 19 20 21 22 23 24 25 26
GND
connecting terminals (closed)
27 28 29 30 31 32 33 34 35 36 37 38 27 28 29 30 31 32 33 34 35 36 37 38
Content of package
SRS-2/4-Z45
- data recorder SRD-99, converter RS-232/RS-485
- assembly brackets - 2 pieces,
- user’s manual for SRD-99 unit and for softwares: Loggy STD-99
Soft and S-Toolkit, Transparent door with moulded frame acc. to DIN 43700,
100 mm
- CD-ROM with the aforesaid manuals in PDF format and lockable with security key.
installations of Loggy Soft and S-Toolkit software Door and frame are made by injection moulding thus
(available optional with extra charge). assuring an exact fit, an optimal choice of a material
which is very strong and with no risk of corrosion; perfect
98 mm
R
Mini USB stick
SIMEX
31,3 mm
Hasło opcji zaawansowanych Loggy Soft: srd system
2.1.2.