Questions and Answers - Photovoltaic Training Session 3
Questions and Answers - Photovoltaic Training Session 3
Questions and Answers - Photovoltaic Training Session 3
MAINTENANCE
Q&A SESSION 3
2
calibration, once every 3 years (maximum)
Martin Gieler: In case of larger If the plant has a large size, it is desirable to
facilities: is there any need to have staff for maintenance and / or security.
have staff onsite? For facilities over 2 Mw you can consider at
least one person, who could solve simple
electrical problems or substitute certain
elements of the facility.
Raj: can i use different Yes, usually the inverter manufacturers use
inverters and different standard communication buses, such us
combiner box for RS485 or Ethernet, so they are usually
communication? compatible with different converter brands.
By the other side, it is important to choose a
software which is compatible with the
inverters we are choosing, and it might be
difficult finding a commercial solution that
supports several brands of inverters for a
good price.
Jonny Huck: In the equation for The length, d, measured on the horizontal
the distance you should leave plane, between 2 rows of modules, of height
between panels (d=h/k), what h, that could produce shades on the facility
did the parameter 'k' refer to? will have to guarantee a minimum of 4 hours
of the Sun concerning the midday of the
winter solstice (summer in southern
hemisphere). This d will be superior to the
value obtained by the formula: d = h/tangent
(61 °-latitude) where 1/tangent (61 °-latitude)
is a coefficient dimensionless called k.
frigitar: Are monitoring systems Normally the monitoring systems are
continuously manned by designed to be automatic, so that they do not
personnel or are there need personnel to be operated. This is the
algorithms that can reason why they usually need calibrated cells
automatically detect if e.g. and weather stations, in order to have a
power loss is due to decrease reference. A good monitoring system should
3
in irradiance... etc. consider all these parameters and give us all
the information, just sending an alarm if the
plant is really producing with a low
performance.
Amr: For 40deg and above, is 40 º is a maximum value for many inverters.
electronic inverters safe to use If the inverters is placed in a closed room, it is
necessary to design a system of ventilation to
reduce this temperature
Thomas Witt: What would be Minimal size does not exist in the
the smallest recommendable photovoltaic technology. This is concretely
plant size? one of its important advantages.
Nevertheless, the plants must have minimal
profitability. For the minimal profitability it is
necessary to contemplate on the one hand
the incomes and on the other hand the
expenses including amortization and financial
costs. It is possible that the part of the
installation necessary for the evacuation of
energy (connection to the electrical grid) has
a cost that forces us to a bigger size of the
plant if we want to reach the desirable
profitability