SECTION 8006 Closed Centre Remote Control Valves
SECTION 8006 Closed Centre Remote Control Valves
SECTION 8006 Closed Centre Remote Control Valves
SECTION 8006
CONTENTS
Description Page
Special Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Tightening Torques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Fault Finding and Pressure Testing Mechanical Remote Valves . . . . . . . . . . . . . . . . . . . . . . 3
Fault Finding and Pressure Testing Electro–Hydraulic Remote Valves . . . . . . . . . . . . . . . . 4
Electro–Hydraulic Remote Valve Fault Code list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6 – 66000 – 06 – 2002
2 SECTION 8006 – HYDRAULIC SYSTEMS
SPECIAL TOOLS
Flowmeter 0–200 ltrs/min Procure Locally
Diagnostic Test Tool 380000488
SPECIFICATIONS
Remote Valve Output 90 ltrs/min. @ 100bar@2200erpm
Detent Regulating Valve Pressure Pre set non adjustable
TORQUES
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 3
2
3. Ensure load valve on flow meter is fully ‘Open’.
4. Set tractor engine speed to 1100 rev/min.
5. Set remote valve No 2 in ‘Float’ position and
remote valve No 1 in ‘Extend’ position.
TIA35086
3
6. Adjust load on flow meter to a of pressure of
100bar.
7. If a flow of 45 ltr/min is recorded output from the
remote valves is to specification.
NOTE: This test is performed at half maximum rated
speed and assumes that flow at rated speed is twice
that measured in the test. Performing the test at 2200
rev/min will give an output of 90 ltr/min.
8. Use same principal to check flow through other
remote valves.
Remote Control Valves Not Working – Mechanical Remote Valves
Is hydraulic lift NO Refer to fault finding chart
working? for hydraulic lift not working
YES
Operate all remote valve
Operate and hold control lever to levers simultaneously
Test maximum system pressure at Is the pressure at the Overhaul remote
each remote valve coupler. NO defective remote valve NO control valve(s) which
Are pressures at each valve now 200–207 bar fail pressure test
coupler below 200–207 bar (2900–3000 lbf/in 2)?
(2900–3000 lbf/in2)?
YES
YES
Examine load sensing valve
Examine flow/pressure between remote valve
compensating valve for sticking sections.
Fault cleared?
6 – 66000 – 06 – 2002
4 SECTION 8006 – HYDRAULIC SYSTEMS
Are all of the EHR YES Is the EHR isolator NO Press the switch to activate,
valves inoperative ? switch activated? do the EHR valves operate?
NO YES NO
Is an electronic Error
code R*** Displayed on
instrument cluster Check operation of the
NO YES switch using a suitable NO Replace the switch
multi–meter. Is the switch
okay?
YES
Refer to fault finding Check the EHR relay. Is the NO Replace the Relay
error code charts in relay operating?
Section 4009 YES
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 5
NOTES
6 – 66000 – 06 – 2002
6 SECTION 8006 – HYDRAULIC SYSTEMS
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 7
6 – 66000 – 06 – 2002
8 SECTION 8006 – HYDRAULIC SYSTEMS
9
Electronic Draft Control and Closed Centre Remote Control Valve Stack
1. Remote Control Valve No I 7. Manifold Block
2. Remote Control Valve No II 8. Return to Reservoir
3. Electronic Draft Control Valve 9. To Hydraulic Lift
4. Remote Control Valve No III 10. Load Sensing Line Connection
5. Remote Control Valve No IIII 11. End Cover
6. Inlet Port
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 9
10
Remote Control Valve and EDC Control Valve Interconnecting Galleries
Load Sensing
1. Parallel Supply Gallery 3. Return to Reservoir
2. Load sensing Gallery
‘O’ ring seals (1) and load sense check valves (2)
between each valve section ensure the highest
circuit load sense pressure is transmitted to control
11
output of the hydraulic pump. 8
6 – 66000 – 06 – 2002
10 SECTION 8006 – HYDRAULIC SYSTEMS
The principal hydraulic components within each in the circuit to flow backwards and the load to
remote control valve section are:– momentarily drop before pump system pressure has
risen to hold and then raise the load further. The load
hold check valve prevents this situation from
Flow Control Adjuster occurring.
The flow control adjuster is manually operated and
adjusts oil flow through the remote valve. Turning the Lock Valve
adjuster changes the size of the restriction in the path
of oil flowing through the flow control spool. The lock valve is located in the raise port of the
remote valve and is closed whenever the remote
valve is in neutral. The lock valve prevents leakdown
Flow Control Spool of an implement should there be any leakage across
the lands of the spool when in the neutral position.
The flow control valve spool senses pressure The lock valve is automatically opened whenever the
differential across the restriction set by the flow control spool is moved from the neutral position.
control adjuster and regulates flow through the
remote valve. Because each flow control spool
individually senses the pressure differential in the Control Valve Spool
remote valve being operated, two or more circuits
working at different pressures can be controlled The control valve spool is spring centred to a neutral
simultaneously. position and when moved directs oil flow to the raise
or lower ports of the control valve.
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 11
12
Closed Centre Remote Control Valve Components
1. Flow Control Adjuster 4. Control Valve Spool
2. Flow Control Spool 5. Load Holding Check Valve
3. Check Valve 6. Spool Centering Mechanism
–
6 – 66000 – 06 – 2002
12 SECTION 8006 – HYDRAULIC SYSTEMS
Figure 13
Single Remote Control Valve Operation–Neutral
1. Flow Control Adjuster 7. Lock Valve
2. Metering Land 8. Raise (Cylinder Extend) Port
3. Flow Control Spool 9. Lower (Cylinder Retract) Port
4. Load Hold Check Valve 10. Spool Centering and Detent Mechanism
5. Main Control Spool 11. Manually Adjusted Flow Control Restriction
6. Pin
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 13
Trapped Oil
6 – 66000 – 06 – 2002
14 SECTION 8006 – HYDRAULIC SYSTEMS
The flow from gallery ‘C’ is blocked by the load hold To maintain set flow through the remotes under all
check valve ball (4) until pressure in the gallery is conditions with varying pump inlet pressure in
sufficient to lift the ball of its seat against the back parallel gallery ‘A’ the flow control spool senses the
pressure in the lift port gallery ‘E’. differential pressure across the manually adjusted
flow control restriction (11) between galleries ‘A’ and
‘B’.
Oil can flow from:–
Gallery ‘C’ past the load hold check valve into The differential pressure sensed on each end of the
Gallery ‘E’. spool causes the spool to move to a new state of
equilibrium and continually regulates the flow across
Across the flat on the main control spool to the spool metering lands (2) to maintain a constant
Gallery ‘F’. flow through the manual flow control restriction (11)
Through the lock valve (7). irrespective of pressure in other hydraulic circuits.
Out through the raise port (8) of the remote valve.
The pressure in gallery ‘C’ is also transmitted down
Exhaust oil from the extending cylinder returns the load sensing gallery ‘D’ to the flow compensating
through the lowering port and gallery (H), around the valve of the variable flow piston pump where pump
land on the main control spool and back to reservoir output is regulated according to circuit demand.
via the common gallery ‘G’.
Figure 14
Single Remote Control Valve Operation–Raising (Cylinder Extend)
1. Flow Control Adjuster 7. Lock Valve
2. Metering Land 8. Raise (Cylinder Extend) Port
3. Flow Control Spool 9. Lower (Cylinder Retract) Port
4. Load Hold Check Valve 10. Spool Centering and Detent Mechanism
5. Main Control Spool 11. Manually Adjusted Flow Control Restriction
6. Pin
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 15
6 – 66000 – 06 – 2002
16 SECTION 8006 – HYDRAULIC SYSTEMS
Gallery ‘B’ is now open to gallery ‘C’ and gallery ‘E’ is Pump output and system pressure will continually
open to gallery ‘H’. react to the maximum demand of the tractor high
pressure hydraulic circuits as sensed through the
Oil from the parallel gallery ‘A’ flows past the flow load sensing lines.
control valve spool and restrictor (2) into gallery ‘C’
and the load sensing gallery ‘D’. Flow through the remotes is controlled in exactly the
same manner as described in the ‘Oil Flow In
The load hold check valve ball (4) remains closed Raising’ section by sensing differential pressure
until pump system pressure is sufficient to overcome across manually flow control restriction (11).
Figure 15
Single Remote Control Valve Operation–Lowering (Cylinder Retract)
1. Flow Control Adjuster 7. Lock Valve
2. Metering Land 8. Raise (Cylinder Extend) Port
3. Flow Control Spool 9. Lower (Cylinder Retract) Port
4. Load Hold Check Valve 10. Spool Centering and Detent Mechanism
5. Main Control Spool 11. Manually Adjusted Flow Control Restriction
6. Pin
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 17
6 – 66000 – 06 – 2002
18 SECTION 8006 – HYDRAULIC SYSTEMS
Figure 16
Single Remote Control Valve Operation–Float
1. Flow Control Adjuster 7. Lock Valve
2. Metering Land 8. Raise (Cylinder Extend) Port
3. Flow Control Spool 9. Lower (Cylinder Retract) Port
4. Load Hold Check Valve 10. Spool Centering and Detent Mechanism
5. Main Control Spool 11. Manually Adjusted Flow Control Restriction
6. Pin
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 19
6 – 66000 – 06 – 2002
20 SECTION 8006 – HYDRAULIC SYSTEMS
Figure 17
Operation of Detent Pressure Regulating Valve
1. Spool Centering and Detent Mechanism 5. Detent Piston
2. Radial Drillings 6. Spring Loaded Plunger
3. Main Control Spool 7. Detent Balls
4. Ball
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 21
6 – 66000 – 06 – 2002
22 SECTION 8006 – HYDRAULIC SYSTEMS
NOTES
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 23
6 – 66000 – 06 – 2002
24 SECTION 8006 – HYDRAULIC SYSTEMS
A. Remote Valve Operating At High Pressure B. Remote Valve Operating At Lower Pressure
1. Parallel Gallery 3. Manually Adjusted Flow Control Restriction
(Interconnecting Remote Valves Sections) 4. Spool Metering Lands
2. Load Sense Line 5. Flow Control Spool
(Interconnecting Remote Valves Sections) 6. Load Sense Line Check Valve
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 25
OPERATION
ELECTRO–HYDRAULIC TYPE REMOTES
Electro–Hydraulic type remote valves are optional on
the 175 and 190 model tractors.
Each remote valve has its own built in
micro–processor which controls the oil flow through
a solenoid activated valve, based on inputs received
from the operator controlled switches.
Each remote valve is connected into the electrical
CAN BUS system to the XCM processor, located
under the Electronic Draft Control panel in the right
hand console. Each remote valve can also detect
system faults and send a message to the XCM
processor which in turn sends a signal to allow a fault 20
code to be displayed on the instrument cluster.
A list of fault codes can be found at the beginning of
this Chapter. The fault finding flow charts can be
found in Section 4009, Electrical Systems.
Control Levers
21
3. Control lever III Brown
2
4. Control lever IIII Black
22
6 – 66000 – 06 – 2002
26 SECTION 8006 – HYDRAULIC SYSTEMS
23
Isolator Switch
The remote valves will not operate unless the system
is energised using the isolator switch (1). Press and
release the switch to activate the system, press
again to de–activate. Once energised, the remote
valves will operate whenever the tractor engine is
running.
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 27
WARNING
Electro–hydraulic valves use detented levers that do
not return to the neutral position when released.
Therefore it is not recommended these valves be
used to operate hydraulic cylinders or similar
equipment that require frequent changes in oil flow
direction.
Manual Operation
When operating hydraulic motors it is important to IMPORTANT: Care must be taken when operating in
always use the RETRACT position to activate the the manual mode with remote cylinders. When the
motor and the FLOAT position to stop the motor. cylinder has reached the end of its stroke the control
Using the float position to stop the motor allows the lever will not return to neutral and the hydraulic
motor to come to a gradual stop preventing possible system relief valve will be activated. This will
damage to the motor itself. overheat the oil and may lead to failure of the
hydraulic and driveline components.
IMPORTANT: Never use the neutral position from
the extend or retract position to stop a hydraulic
motor. Sudden hydraulic lock up of the system may
cause extensive damage to the motor.
6 – 66000 – 06 – 2002
28 SECTION 8006 – HYDRAULIC SYSTEMS
Programmable Operation
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 29
6 – 66000 – 06 – 2002
30 SECTION 8006 – HYDRAULIC SYSTEMS
QUICK COUPLERS
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 31
6 – 66000 – 06 – 2002
32 SECTION 8006 – HYDRAULIC SYSTEMS
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 33
6 – 66000 – 06 – 2002
34 SECTION 8006 – HYDRAULIC SYSTEMS
When the light goes out move the remote valve lever
to the float position. 36
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 35
DESCRIPTION
The remote valves (1) are a stack type design
clamped together with the hydraulic lift electronic
draft control valve (2). The stack assembly also
incorporates the low pressure regulating and priority
valve (3).
37
38
Electronic Draft Control and Closed Centre Remote Control Valve Stack
1. Low Pressure Regulating and Priority Valve 10. Pilot Line Joining Tube
2. Remote Control Valve No I 11. Return to Reservoir
3. Remote Control Valve No II 12. To Hydraulic Lift
4. Electronic Draft Control Valve 13. Suspended Front Axle Supply
5. Manifold Block 14. Regulated Low Pressure Output
6. Remote Control Valve No III 15. High Pressure Inlet
7. Remote Control Valve No IIII 16. Load Sensing Line Connection
8. Remote Control Valve No. V 17. End Plate
9. End Plate
6 – 66000 – 06 – 2002
36 SECTION 8006 – HYDRAULIC SYSTEMS
39
Remote Control Valve and EDC Control Valve Interconnecting Galleries
‘O’ ring seals (1) and load sense check valves (2)
40
between each valve section ensure the highest
circuit load sense pressure is transmitted to control
output of the hydraulic pump.
8
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 37
The principal hydraulic components within each When a cylinder is holding a heavy load and the
Electro–Hydraulic remote control valve section are:– control valve spool is moved from the neutral to raise
position, the pump system pressure may be less
than the back pressure in the remote valve circuit.
Solenoid Control Unit (Figure 40) When this occurs the back pressure would cause oil
in the circuit to flow backwards and the load to
A signal to operate a solenoid activated valve is momentarily drop before pump system pressure has
received from the operator control switches into the risen to hold and then raise the load further. The load
micro–processor of the control unit. The spool within hold check valve prevents this situation from
the solenoid valve moves according to the forces of occurring.
the solenoid which allows pilot oil pressure, regulated
to 21–24 bar, to act on the control valve spool. The
control unit is also able to accurately sense the Lock Valve (5)
position of the spool and can detect errors in the
system, which, via the CAN BUS electrics, can be The lock valve is located in the raise port of the
displayed as fault codes which have a ’R’ prefix. remote valve and is closed whenever the remote
valve is in neutral. The lock valve prevents leakdown
of an implement should there be any leakage across
Flow Control Spool (2) the lands of the spool when in the neutral position.
The lock valve is automatically opened whenever the
Ensures that if more than one remote valve is control spool is moved from the neutral position.
operated that the available oil flow is proportionally
distributed amongst the valves being operated
depending on demand. The flow control valve spool Control Valve Spool (4)
senses the differential pressure within the valve and
regulates the flow accordingly. Because each flow The control valve spool is spring centred to a neutral
control spool individually senses the pressure in the position and when moved by the regulated pilot
remote valve being operated, two or more circuits pressure, via the solenoid control unit, directs oil flow
working at different pressures can be controlled to the raise or lower ports of the control valve.
simultaneously.
6 – 66000 – 06 – 2002
38 SECTION 8006 – HYDRAULIC SYSTEMS
41
Closed Centre Remote Control Valve Components
1. Flow Control Spool 4. Control Valve Spool
2. Check Valve 5. Load Holding Check Valve
3. Spool Centering Spring
–
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 39
42
Control Unit Assembly
1. Solenoid Valve 4. Control Piston and Seal
2. Control Valve Spool 5. Position Sensor
3. Centering Spring 6. Control Micro Processor
–
6 – 66000 – 06 – 2002
40 SECTION 8006 – HYDRAULIC SYSTEMS
Figure 43
Single Remote Control Valve Operation–Neutral
1. Flow Control Spool 8. Micro Processor
2. Metering Land 9. Solenoid Valve
3. Load Hold Check Valve 10. Pin
4. Main Control Spool 11. Lock Valve
5. Spool Centering Spring 12. Raise (Cylinder Extend) Port
6. Control Spool Operating Piston 13. Lower (Cylinder Retract) Port
7. Position Sensor
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 41
1 2 3 4 5
7
A
C
B D E
F I
13 G
H
J
12 11 10 9 8
BSD2016A
Single Remote Control Valve Operation–Neutral 43
6 – 66000 – 06 – 2002
42 SECTION 8006 – HYDRAULIC SYSTEMS
Gallery ‘C’ past the load hold check valve into The differential pressure sensed on each end of the
Gallery ‘E’. spool causes the spool to move to a new state of
equilibrium and continually regulates the flow across
Across the flat on the main control spool to the spool metering lands (2) to maintain a constant
Gallery ‘F’. flow through the flow control restrictio,n irrespective
Through the lock valve (7). of pressure in other hydraulic circuits.
Out through the raise port (8) of the remote valve.
The pressure in gallery ‘C’ is also transmitted down
Exhaust oil from the extending cylinder returns the load sensing gallery ‘D’ to the flow compensating
through the lowering port and gallery (H), around the valve of the variable flow piston pump where pump
land on the main control spool and back to reservoir output is regulated according to circuit demand.
via the common gallery ‘G’.
Figure 44
Single Remote Control Valve Operation–Raising (Cylinder Extend)
1. Flow Control Spool 8. Micro Processor
2. Metering Land 9. Solenoid Valve
3. Load Hold Check Valve 10. Pin
4. Main Control Spool 11. Lock Valve
5. Spool Centering Spring 12. Raise (Cylinder Extend) Port
6. Control Spool Operating Piston 13. Lower (Cylinder Retract) Port
7. Position Sensor
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 43
1 2 3 4 5
7
A
C
B D E
F I
13 G
H
J
12 11 10 9 8
BSD2017A
6 – 66000 – 06 – 2002
44 SECTION 8006 – HYDRAULIC SYSTEMS
Gallery ‘B’ is now open to gallery ‘C’ and gallery ‘E’ is Pump output and system pressure will continually
open to gallery ‘H’. react to the maximum demand of the tractor high
pressure hydraulic circuits as sensed through the
Oil from the parallel gallery ‘A’ flows past the flow load sensing lines.
control valve spool and restrictor (2) into gallery ‘C’
and the load sensing gallery ‘D’. Flow through the remotes is controlled in exactly the
same manner as described in the ‘Oil Flow In
The load hold check valve ball (4) remains closed Raising’ section by sensing differential pressure
until pump system pressure is sufficient to overcome across the flow control spool.
Figure 45
Single Remote Control Valve Operation–Lowering (Cylinder Retract)
1. Flow Control Spool 8. Micro Processor
2. Metering Land 9. Solenoid Valve
3. Load Hold Check Valve 10. Pin
4. Main Control Spool 11. Lock Valve
5. Spool Centering Spring 12. Raise (Cylinder Extend) Port
6. Control Spool Operating Piston 13. Lower (Cylinder Retract) Port
7. Position Sensor
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 45
1 2 3 4 5
7
A
C
B D E
F I
13 G
H
J
12 11 10 9 8
BSD2018A
6 – 66000 – 06 – 2002
46 SECTION 8006 – HYDRAULIC SYSTEMS
When the remote valve operator control switch is Should a void occur in the circuit oil will be drawn by
moved to the float position the control spool is moved suction from one side of the cylinder to the other.
fully to the right via pilot line oil from the solenoid
control unit, supplied from gallery ’I’.
Oil flow from the gallery (B) to the raise and lower
ports is blocked by the land of the spool end.
Figure 46
Single Remote Control Valve Operation–Float
1. Flow Control Spool 8. Micro Processor
2. Metering Land 9. Solenoid Valve
3. Load Hold Check Valve 10. Pin
4. Main Control Spool 11. Lock Valve
5. Spool Centering Spring 12. Raise (Cylinder Extend) Port
6. Control Spool Operating Piston 13. Lower (Cylinder Retract) Port
7. Position Sensor
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 47
1 2 3 4 5
7
A
C
B D E
F I
13 G
H
J
12 11 10 9 8
BSD2019A
6 – 66000 – 06 – 2002
48 SECTION 8006 – HYDRAULIC SYSTEMS
NOTES
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 49
6 – 66000 – 06 – 2002
50 SECTION 8006 – HYDRAULIC SYSTEMS
A. Remote Valve Operating At High Pressure B. Remote Valve Operating At Lower Pressure
1. Parallel Gallery 3. Spool Metering Lands
(Interconnecting Remote Valves Sections)
4. Flow Control Spool
2. Load Sense Line
(Interconnecting Remote Valves Sections) 5. Load Sense Line Check Valve
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 51
OVERHAUL
MECHANICALLY CONTROLLED REMOTE
VALVES
50
4. To aid re–assembly draw a diagonal line across
the valve stack.
51
5. Remove a clamping bolt and install guide pin
made in step 1.
NOTE: The valve stack is very heavy DO NOT
attempt to remove valves without the use of guide
pins.
6. Repeat procedure for remaining two clamp bolts.
52
6 – 66000 – 06 – 2002
52 SECTION 8006 – HYDRAULIC SYSTEMS
Installation
1. Install using removal procedure in reverse.
53
Remote valves 3 and 4
Removal
1. Install guide pins using same procedure as for
remote valves 1 and 2.
NOTE: Small shims (1) are positioned between the
manifold (2) and remote valve number 3 (3). Take
care when installing guide pins not to damage the
shims.
2. Remove end plate and valve assemblies.
54
Installation
1. Apply petroleum jelly to the shims (1) and
position on each guide pin.
55
2. Install remote valves and end cap
56
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 53
57
4. Tighten clamp bolts to 30Nm in sequence 1,2,3.
58
Removal and Installation–
Complete Valve Stack
1. Steam clean remote control valve assembly prior
to removal.
2. Lower hydraulic links.
3. Remove covers on remote valve couplers.
59
4. Remove trailer socket (1) and disconnect
electrical connections to each electronic draft
control solenoid (2).
60
6 – 66000 – 06 – 2002
54 SECTION 8006 – HYDRAULIC SYSTEMS
61
6. Remove load sense line (2) and disconnect
hydraulic pipes (1) at rear of remote valve stack.
62
7. Using suitable lifting equipment support remote
valve assembly, remove base securing bolts and
lift valve stack from tractor.
8. Retrieve ‘O’ ring (1)
63
9. Installation follows removal procedure in
reverse. Tighten retaining bolts to torque of
43Nm.
64
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 55
65
Closed Centre Remote Control Valve Components
1. Flow Control Adjuster 4. Control Valve Spool
2. Flow Control Spool 5. Load Holding Check Valve
3. Check Valve 6. Spool Centring Mechanism
–
66
6 – 66000 – 06 – 2002
56 SECTION 8006 – HYDRAULIC SYSTEMS
67
Remote Valve and Coupler Housing
1. Valve Section 4. Coupler Housing
2. ‘O’ Ring 5. Seat
3. Coupler 6. ‘O’ Ring
5. Remove spool.
NOTE: Prior to removing spool ensure flats(1) on
end of spool are in vertical position as shown. If it is
necessary to rotate spool Do not use force otherwise
damage to spool and load check valve pin will occur.
68
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 57
69
70
Load Check Valve
1. Plunger 5. Washer
2. Load Holding Valve 6. Spring
3. Ball 7. Spring Seat
4. Spring 8. Keeper
6 – 66000 – 06 – 2002
58 SECTION 8006 – HYDRAULIC SYSTEMS
71
72
Flow Control Spool and Check Valve
1. Flow Control Spool 7. Retainer
2. Retainer 8. Plug
3. Spring 9. Back–up Ring
4. Spring Guide 10. ‘O’ Ring
5. Plug and ‘O’ Ring 11. Spring
6. Plastic Cap 12. Check Valve Ball
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 59
73
Control Valve Spool
1. End Cap 8. Spacer
2. ‘O’ Ring 9. Back–Up Ring
3. Shims 10. Detent Release Orifice
4. Spool Centring Mechanism 11. Ball
5. Spool 12. Plunger
6. ‘O’ Ring 13. Spring
7. ‘O’ Ring 14. Spring Seat
8. Remove control valve spool by unscrewing the 9. Housed within the centre of the spool is the
spool centring mechanism. It is not detent release orifice. This is factory preset and
recommended that the mechanism is servicing should be restricted to washing in an
disassembled. approved degreasing agent without removing
the orifice from within the spool.
6 – 66000 – 06 – 2002
60 SECTION 8006 – HYDRAULIC SYSTEMS
Re–Assembly
1. Re–assembly follows the disassembly
procedure in reverse. Install the load holding
valve prior to installing control valve spool.
2. Prior to inserting control valve spool in housing
ensure flats (1) on end of spool are in vertical
position as shown. Do Not rotate spool once
inserted into bore otherwise damage to spool
and load holding valve plunger will occur.
74
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 61
OVERHAUL
ELECTRO HYDRAULIC REMOTE VALVES
75
Electronically Controlled Remote Valve Installation
1. End Cap 6. Remote Valve No 2
2. Remote Valve No 5 (Hydraulic Levelling) 7. Remote Valve No 1
3. Remote Valve No 4 8. Low Pressure Priority Valve
4. Remote Valve No 3 9. End Cap
5. EDC Valve 10. Manifold
6 – 66000 – 06 – 2002
62 SECTION 8006 – HYDRAULIC SYSTEMS
76
1. With all the remote valves connected to the har-
ness, install diagnostic test switch, tool No.
380000488. Turn the Key Start switch ON and
select H–menu Mode HL.
77
2. Operate the No.1 EHR Valve timer switch 3 times
in quick succession to activate the procedure.
3. The number 3 will be displayed followed by 2, 1
and then END. This will have erased the memory
from each valve assembly.
78
5. Disconnect the connectors from each remote
valve.
79
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 63
80
8. When the last valve has been recognised pulse
the No.1 EHR Valve timer switch 3 times in quick
succession.
9. The number 3 will be displayed followed by 2, 1
and then END. This will signify the end of the pro-
cedure.
81
10. Turn the key start switch OFF to store the pro-
gramming.
NOTE: After the installation of a new or repaired
valve it will be necessary to recalibrate the control
lever. Refer to ’recalibrating the control levers’
detailed earlier in this Chapter.
82
6 – 66000 – 06 – 2002
64 SECTION 8006 – HYDRAULIC SYSTEMS
Valve Removal
NOTE: Individual remote valve assemblies can be
removed from the tractor without the need to remove
the complete valve stack.
1. Lower hydraulic links and thoroughly clean
remote valve stack.
2. To aid re–assembly draw a diagonal line across
the valve stack.
83
84
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 65
85
Electronic Draft Control and Closed Centre Remote Control Valve Stack
1. Low Pressure Regulating and Priority Valve 10. Pilot Line Joining Tube
2. Remote Control Valve No I 11. Return to Reservoir
3. Remote Control Valve No II 12. To Hydraulic Lift
4. Electronic Draft Control Valve 13. Suspended Front Axle Supply
5. Manifold Block 14. Regulated Low Pressure Output
6. Remote Control Valve No III 15. High Pressure Inlet
7. Remote Control Valve No IIII 16. Load Sensing Line Connection
8. Remote Control Valve No. V 17. End Plate
9. End Plate
6 – 66000 – 06 – 2002
66 SECTION 8006 – HYDRAULIC SYSTEMS
86
6. Remove end cap.
87
7. Remove low pressure priority valve.
88
8. Remove remote valves 1 and 2.
89
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 67
90
10. Repeat procedure to remote valves on opposite
side of manifold. Note that a spacer (1) is fitted
between remote valves 4 and 5.
91
11. When removing remote valve No 3 be careful not
to loose the spring (2) which sits in the load sense
check valve (1) located in the manifold. The
check valve is held in position by ‘O’ ring (3).
92
Installation
installation follows removal procedure in reverse.
12. Install end caps and tighten bolts to specified
torque in sequence 1,2,3.
93
6 – 66000 – 06 – 2002
68 SECTION 8006 – HYDRAULIC SYSTEMS
94
95
Remote Valve and Coupler Housing
1. Spool Control Unit 5. Coupler Housing
2. Remote Valve Body 6. ‘O’ Ring
3. Cap 7. Seat
4. ‘O’ Ring
2. The couplers are serviced as an assembly and NOTE: DO NOT attempt to remove the spool until
should not be disassembled. the load holding valve (5) Figure 96 has been
removed, otherwise damage to the spool will occur.
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 69
96
Electro–Hydraulic Controlled Closed Centre Remote Control Valve Components
1. Spool Control Unit 4. Check Valve
2. Load Holding Check Valve 5. Flow Control Spool
3. Control Valve Spool
–
6 – 66000 – 06 – 2002
70 SECTION 8006 – HYDRAULIC SYSTEMS
97
98
Load Check Valve
1. Plunger 5. Washer
2. Load Holding Valve 6. Spring
3. Ball 7. Spring Seat
4. Spring 8. Keeper
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 71
99
100
Flow Control Spool and Check Valve
1. Flow Control Spool 7. Plug
2. Spring 8. Back–up Ring
3. Spring Guide 9. ‘O’ Ring
4. Plug and ‘O’ Ring 10. Spring
5. Plastic Cap 11. Check Valve Ball
6. Retainer
6 – 66000 – 06 – 2002
72 SECTION 8006 – HYDRAULIC SYSTEMS
101
Re–Assembly
1. Re–assembly follows the disassembly
procedure in reverse.
2. Prior to inserting control valve spool in housing
ensure flats (1) on end of spool are in vertical
position as shown, then install the load holding
valve, Figure 98. Do Not rotate spool after
installing load holding valve otherwise damage to
spool and load holding valve plunger will occur.
102
Removal and Installation–
Complete Valve Stack new pic
103
4. Disconnect connections to electronic draft
control valve solenoid (1).
104
6 – 66000 – 06 – 2002
SECTION 8006 – HYDRAULIC SYSTEMS 73
105
6. Disconnect hydraulic pipes at rear of remote
valve stack. Refer to Figure 85 for further
details.
106
7. Using suitable lifting equipment support remote
valve assembly, remove base securing bolts and
lift valve stack from tractor.
8. Retrieve ‘O’ ring (1)
107
9. Installation follows removal procedure in
reverse. Tighten retaining bolts to torque of
43Nm.
108
6 – 66000 – 06 – 2002
74 SECTION 8006 – HYDRAULIC SYSTEMS
NOTES
6 – 66000 – 06 – 2002