MasterSeal® 550

Acrylic reinforced cementitious, flexible waterproof coating

DESCRIPTION ADVANTAGES
MasterSeal 550 is a two component acrylic  Waterproof
modified cementitious coating that requires only  Excellent adhesion. Bonds to porous and non-
on site mixing to form the ideal product to porous surfaces.
waterproof and resurface concrete, masonry, and  Flexible.
most other construction materials.  Non toxic suitable for contact with potable
Simply applied by stiff brush, roller, or trowel, it water.
forms a waterproof, flexible coating.  Suitable for light pedestrian traffic.
MasterSeal 550 provides an effective barrier to  Breathable - whilst repelling water, allows
waterborne salts and atmospheric gases. substrate to breathe.
Fluid applied, MasterSeal 550 provides a hard  High resistance to chloride ion diffusion.
wearing, seamless, waterproof membrane for
 Unlike conventional coatings which require a
roofs and foundation protection.
7-28 day cure of concrete, MasterSeal 550 can
be applied to 24 hour-old concrete thereby
TYPICAL APPLICATIONS giving immediate protection.
 To reface and even out variations in concrete
surfaces. COMPOSITION
 As a waterproof lining for water retaining MasterSeal 550 is composed of specially selected
structures. cements, silica sand and reactive fillers supplied in
 For coating seawater channels. powder form together with a liquid component of
 Sealing and coating tie bar holes to ensure blended acrylic copolymers and wetting agents.
watertightness.
 For waterproofing and protection against TYPICAL PROPERTIES*
brackish water.
 To provide foundation protection. Density 1826kg/m³
 As a waterproof coating for roofs. Toxicity BS 6920 Non toxic - Suitable for
 As a backing to marble and granite to prevent use in contact with
water ingress and thus alleviate surface potable water
Chloride ion diffusivity Not measurable after
staining. 24 months of testing
 To provide protection to concrete surfaces from Depth of water penetration under Nil
carbonation and chloride attack. pressure BS EN 12390 Part 8 : 2009
<0.1 kg/(m²xh 0.5)
 For use on pedestrian walkways in marine Liquid water permeability
BS EN 1062-3 : 2008
areas. Carbon dioxide permeability BS EN >50m
1062-6 : 2002 Method A
PACKAGING Equivalent air layer thickness (SD)

MasterSeal 550 is available in 20kg double pack.


STANDARDS
MasterSeal 550 is available in three standard BS 6920 : Part 1 2000 - Suitable for use in contact
colours: J-Light Grey, K-White and H-Dark Grey. with potable water.
MasterSeal® 550

CHLORIDE ION DIFFUSIVITY MIXING


MasterSeal 550 provides an effective barrier to MasterSeal 550 is supplied in premeasured units
waterborne salts such as chlorides and sulphates. and should be mixed on site utilising clean
*lndependent assessment has shown that even containers. Slowly add the powder to the liquid
after 12 months constant immersion the chloride and mix, using a slow speed drill fitted with a
ion diffusion co-efficient could not be measured for suitable paddle. MIX AND USE. Do not mix more
MasterSeal 550. material than can be used in one hour.

CHEMICAL RESISTANCE NOTE: Although MasterSeal 550 is supplied in


MasterSeal 550 has outstanding wear and premeasured packs, part packs can be used by
weather resistance and good resistance to sodium mixing 2 volumes of powder to 1 volume of liquid.
hydroxide, calcium chloride, de-icing salts. Mix thoroughly and keep mixed during application.
MasterSeal 550 coated surfaces exhibit good DO NOT RE-TEMPER WITH WATER.
resistance to mild acids.
APPLICATION
ANTI CARBONATION COATING Do not apply to dry concrete
MasterSeal 550 is an extremely effective barrier Saturate concrete surfaces with clean water whilst
to atmospheric acidic gases which cause still visibly damp, but free of standing water, apply,
carbonation in concrete structures. MasterSeal using a short, stiff bristle brush or roller. Trowel
application can be undertaken as necessary. For
550 at an applied rate of 1.8 kg/m² gives an
heavy 6-10mm depressions, honeycombs etc. use
equivalent air layer thickness for carbon dioxide
less gauging liquid and mix to the desired
diffusion (R) of 92 metres. The accepted minimum
consistency. Where more than one coat is found
value for R is 50m. Testing to confirm this was
necessary to achieve the desired thickness, apply
carried out independently by Taywood
the second or subsequent coats after the previous
Engineering 2005. A report is available on
coat has dried.
request.
It is recommended, for general resurfacing, that
APPLICATION PROCEDURE each coat should be a minimum of 1mm thick.
Surface preparation: Spray application is recommended for large areas,
As with all coating systems, surface preparation is details of suitable equipment can be provided by
of prime importance. Remove all grease, oil, dust, BASF’s Technical Service Dept.
residual curing compound, mould release agent or
other contaminant that could impair adhesion. COVERAGE
Laitance should preferably be removed by light
1.8 kg / m² at 1 mm thickness.
sweep blasting or hydro-jetting. Mechanical wire
brushing may be appropriate for small areas.
Spalled concrete should be cut back to sound
concrete and made good with a suitable
cementitious repair mortar such as
MasterEmaco S 488. Conventional concrete
curing compounds should be removed before
application. The exception to this is when
MasterKure 181 has been used. Roofing tiles
should be firmly bedded and grouted before
application.
MasterSeal® 550

NOTES QUALITY AND CARE


Where subsequent tiling works are to be carried All products originating from BASF’s Dubai, UAE
out on vertical surfaces, contact the local BASF facility are manufactured under a management
representative for advice. system independently certified to conform to the
requirements of the quality, environmental and
SAFETY PRECAUTIONS occupational health & safety standards ISO 9001,
As with all chemical products, care should be ISO 14001 and OHSAS 18001.
taken during use and storage to avoid contact with
eyes, mouth, skin and foodstuffs. Treat splashes * Properties listed are based on laboratory controlled tests.
to eyes and skin immediately. If accidentally
ingested, seek immediate medical attention. ® = Registered trademark of the BASF-Group in many countries.

STORAGE
Store out of direct sunlight, clear of the ground on
pallets protected from rainfall. Avoid excessive
compaction.

Failure to comply with the recommended storage


conditions may result in premature deterioration of
the product or packaging. For specific storage
advice consult BASF's Technical Services
Department.

NOTE
Field service, where provided, does not constitute
supervisory responsibility. For additional
information contact your local BASF
representative.

BASF reserves the right to have the true cause of


any difficulty determined by accepted test
methods.

BASF_CC-UAE/Sl_550_12_94/v6/07_17
The technical information and application advice given in this BASF publication are based on the present state of
STATEMENT OF our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be
RESPONSIBILITY made as to a product's suitability for a particular use or application and no warranty as to its accuracy, reliability or
completeness either expressed or implied is given other than those required by law. The user is responsible for
checking the suitability of products for their intended use.

Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either
NOTE orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not
BASF, are responsible for carrying out procedures appropriate to a specific application.

BASF Construction Chemicals UAE LLC


Disclaimer: the LRQA mark relates
P.O. Box 37127, Dubai, UAE to certified management system and
Tel: +971 4 8090800, Fax: +971 4 8851002 not to the product mentioned on this
www.master-builders-solutions.basf.ae datasheet