The standard specifies requirements for mortar used for laying fireclay refractories. It describes different grades of fireclay mortar and their physical properties and test methods.

The standard covers requirements for mortar used for laying fireclay refractories. It specifies two grades of fireclay mortar and test methods to check properties like fineness, refractoriness, shrinkage etc.

The standard specifies two grades of fireclay mortar - Grade 1 and Grade 2. Grade 1 has higher Al2O3 and lower Fe2O3 content compared to Grade 2.

Indian Standard

FIRECLAY MORTAR FOR


LAYING FIRECLAY REFRACTORY
BRICKS -SPECIFICATION
( Third Revision )

First Reprint OCTOBER1998

UDC 666’767 : 666 ‘76216 - 43 1

Q BIS 1991

BUREAU OF INDIAN STANDARDS


MANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARG
NEW DELHI 110002

Arrglrst 199 1 Price Group 1


Refractories Sectional Committee, MTD 15

FOREWORD

This Indian Standard ( Third Revision ) was adopted by the Bureau of Indian Standards, after the
draft finalised by the Refractories Sectional Committee had been approved by the Metallurgical
Engineering Division Council.

Fireclay mortar is mainly a suitable mixture of plastic fireclay and fireclay grog ( calcined fireclay
or broken fireclay refractories ). Fireclay mortar specified in this standard is used for laying
fireclay refractory bricks conforming to :

IS 6 : 1983 Moderate heat duty fireclay refractories, Group A (fourth revision )


IS 7 : 1980 Moderate heat duty fireclay refractories, Group B (jourrh revision )
IS 8 : 1983 High heat duty fireclay refractories (fourrh revision )
IS 483 : 1972 Fireclay refractories for oil-fired boiler furnaces on naval ships (fjrsf revision )
IS 2043 : 1984 Siliceous fireclay refractories (firs? revision )

For determining fineness of fireclay mortar the aperture sizes are based on IS 460 ( Part 2 ) : 1985
‘Test sieves: Part 2 Perforated plate test sieves ( third revision )‘. Where these sieves are not available
other equivalent standard sieves may be used.

In the preparation of this standard, the Sectional Committee, kept in view the manufacturing and
trade practices followed in the country in this field.

Wherever a reference to any Indian Standard appears in this specification, it shall be taken as a
reference to the latest version of the standard.

For the purpose of deciding whether a particular requirement of this standard is complied with, the
i
final value, observed or calculated, expressing the result of a test or analysis, shall be rounded off in
accordance with IS 2 : 1960 ‘Kules for rounding off numerical values ( revised)‘. The number of
significant places retained in the rounded off value should be the same as that of the specified value
in this standard.
IS 195 : 1991

Indian Standard
FIRECLAY MORTAR FOR
LAYING FIRECLAY REFRACTORY
BRICKS - SPECIFICATION
( Third Revision )
1 SCOPE 4 SAMPLING
This standard covers the requirments for mortar 4.1 Representative samples shall be drawn
used for laying fireclay refractories. according to the scheme of sampling given in
IS 1528 ( Part 7 ) : 1974.
2 REFERENCES
5 CHEMICAL COMPOSITION
The following Indian -Standards are necessary
adjuncts to this standard: The chemical composition of different grades of
fireclay mortar with respect to Al303 and Fez03
IS No. Title
content when tested in accordance with the
6 : 1983 Moderate heat duty fireclay method given in IS 1527 : 1972, shall be as given
refractories, group A (fourth in Table 1.
revision ) 6 PHYSICAL REQUIREMENTS
7 : 1980 Moderate heat duty fireclay 6.1 Drying and Firing Shrinkage
refractories, group B (fourth
revision ) The drying and firing shrinkage of different types
of fireclay mortar shall be as given in Table 1.
8 : 1983 High heat duty fireclay refrac-
tories (fourth revision ) 6.1.1 Drying and firing shrinkage shall be
measured on hand moulded briquettes made after
460 Test sieves : Part 2 Perforated thorough mixing of mortar with LO-20 percent of
(Part2): 1985 plate test seives ( third revision ) water. Samples to be prepared by casting.
483 : 1972 Fireclay refractories for oilfired 6.1.2 The size of the briquettes should be 160
boiler furnaces of naval ships mm x 40 mm X 40 mm. The other size of
(jirst revision 1 briquettes may also be used. The same briquettes
1387 : 1967 General requirements for the as for firing test, may be used subsequently.
supply of metallurgical materials
6.2 Fineness
1527 : 1972 Methods for chemical analysis
6.2.1 The fineness of difierent grades of fireclay
of high silica refractory materials
mortar shall be as given in Table 1.
1528 Method of sampling and physi-
6.2.2 No particle of fireclay mortar shall be so
(Part 1): 1980 cal test for refractory materials: large as to be retained on IS-sieve 1’6 mm.
Part 1 Determination of pyro-
metric cone equivalent ( PCE ) 6.3 Refractoriness
or softening point ( second
revisiun ) 6.3.1 Fireclay mortar when tested in ascordance
with the method given in IS 1528 ( Part 1 ) : 1980.
I528 Method of sampling and physi- for pyrohletric cone equivalent shall conform to
(Part7): 1974 cal test fol: refractory materials: the values given in Table 1.
Part 7 Methods of sampling and
criteria for conformity (first 7 PACKING
revision ) 7.1 Unless otherwise specified, the material shall
be supplied in gunny bags each containing 50 kg
3 SUPPLY OF MATERIAL fire clay mortar.
3.1 General requirements relating to the supply 8 MARKING
of fireclay mortar shall be as laid down in
8.1 The containers shall be clearly marked with
IS 1387 : 1967. manufacturer’s name or trade-mark, and grade
and type of the material.
3.2 The material shall be ground evenly and shall
be of such quality and plasticity as would enable 8.2 Standard Marking
it to be spread satisfactorily. with a trowel when
tempered with an adequate amount of water. Product may also be marked with Standard Mark.

1
IS 19s : 1991

Table 1 Fhysical Test Requirements


(Clauses 5, 6.1,6.2.1 and6.3.1)

SI No. Characteristics Requirements Test Method


y----A------ 7 ( ReftoB 1528)
Grade 1 Grade 2
(1) ( 2) (3) (4) (5)

9 AllOII percent, MB 37 30
ii) Fe,O, percent, MUX 3 2’5

iii) Pyrometric cone equivalent ( ASTM ), 31 29 Part 1


Standard Cone No.. Min
iv) Dryi:; shrinkage at 1 lO”C, percent, 2 2 -

v) Firing shrinkage at temperature,percent, 0’5 3.0


Max ( at I4OO”C ( at I 35O’C
for 2 hours ) for 2 hours )
vi) 95 percent passing through 1S sieve, 150 842 -
micron, Milt

2
Bureau of Indian Standards

BIS is a statutory institution established under the Bureau of Indian Standards Act, 1986 to promote
harmonious development of the activities of standardization, marking and quality certification of goods and
attending to connected matters in the country.

Copyright

BIS has the copyright of aI’1its publications. No part of these publications may be reproduced in any form
without the prior permission in writing of BIS. This does not preclude the free use, in the course of
implementing the standard, of necessary details, such as symbols and sizes, type or grade designations.
Enquiries relating to copyright be addressed to the Director (Publication), BIS.

Review of Indian Standards

Amendments are issued to standards as the need arises on the basis of comments. Standards are also reviewed
periodically; a standard along with amendments is reaffirmed when such review indicates that no changes are
needed; if the review indicates that changes are needed, it is taken up for revision. Users of Indian Standards
should ascertain that they are in possession of the latest amendments or edition by referring to the latest issue
of ‘BIS Handbook’ and ‘Standards Monthly Additions’.
This Indian Standard has been developed from Dot: No. MTD I5 ( 3693 1

Amendments Issued Since Publication

Amend No. Date of Issue Text Affected

BUREAU OF INDIAN STANDARDS


Headquarters:
Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 110002 Telegrams: Manaksanstha
Telephones: 323 01 31,323 33 75,323 94 02 (Common to all offices)

Regional Offices: Telephone

Central : Manak Bhavan, 9 Bahadur Shah Zafar Marg 32376 17,3233841


NEW DELHI 110002

Eastern : l/14 C.I.T. Scheme VII M, V.I.P. Road, Maniktola 337 84 99,337 85 61
CALCUTTA 700054 337 86 26,337 91 20

Northern : SC0 335336, Sector 34-A, CHANDIGARH 160022 60 38 43


{ 60 20 25

Southern : C.I.T. Campus, IV Cross Road, CHENNAI 600113 235 02 16,235 04 42


{ 2351519,2352315

Western : Manakalaya,E9 MIDC, Marol, Andheri (East) 832 92 95,832 78 58


MUMBAI 400093 { 832 78 91,832 78 92

Branches : AHMADABAD. BANGALORE. BHOPAL. BHUBANESHWAR.


COIMBATORE. FARIDABAD. GHAZIABAD. GUWAHATI.
HYDERABAD. JAIPUR. KANPUR. LUCKNOW. NAGPUR.
PATNA. PUNE. THIRUVANANTHAPURAM.
Printed by Reprography Unit, BIS. New Delhi