Bbe Product

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

▶▶ Innovative spectral

fluorometers with
integrated algal class
determination

▶▶ Wide selection of
measurement instru-
ments for continuous
toxicity monitoring

▶▶ bbe has been an


expert in the field
of fluorometry for
over 20 years

BIOMONITORs

Chlorophyll Fluorometers

www.bbe-moldaenke.de
TOXIcity
Chlorophyll Contents

TOXIcity
Chlorophyll 8 15

About us
7
4 Who we are and what we do

About Chlorophyll &


Toxicity
5 Some facts about algae detection

5 Some facts about toxicity


6

Chlorophyll
6 AlgaeTorch

14 7 BenthoTorch

8 FluoroProbe III

9 AlgaeLabAnalyser

13 10 AlgaeOnlineAnalyser
9
11 AlgaeGuard

12 IOcells
11

Toxicity
12 13 AlgaeToximeter II

14 DaphniaToximeter II

15 ToxProtect64

10

bbe moldaenke ©   |  Contents 3


About
Chlorophyll & Toxicity

Some facts about algae detection


Chlorophyll is a universal pigment in the process of photosynthesis. It is distri-
buted in all micro-phytoplankton and can be easily used for the estimation
of the amount of microalgae and cyanobacteria in sample water. Beside
About us microscopic analysis the extraction of pigments and the measurement of
chlorophyll absorption or fluorescence are widely used. Both methods


are laborious and are subjected to limitations in accuracy and sensi-


Water is the source of all life! tivity. Nevertheless, the microscopic picture allows a classification of
Good water quality is a pre-requisite for our future phytoplankton due to shape and appearance. Another approach with
and is a great challenge. To be involved in this, high sensitivity uses in vivo fluorescence. This rapid method can be
bbe has committed itself to water quality monitoring! applied in the field and enables a distinction of up to 4 algae classes
in one measurement. In vivo fluorometry is perfect for high-resolution
profiling in lakes, rivers and reservoirs. This method finds its application in the
uptake of water for the drinking water processing or in ecological monitoring.
Who we are and what we do
For more than 20 years bbe Moldaenke GmbH has been one of the leading manufacturers of out- You can find our bbe spectrofluorometers on site 6 to 12
standing environmental technology products. bbe develops and produces measuring instruments
and software for the monitoring of water quality. Our instruments are used e.g. in oceanography and
limnology, in the analysis of drinking and raw water, in the measurement of bathing water quality, in
the monitoring of aquaculture systems and diverse environmental assessments.
Some facts about toxicity
bbe Moldaenke GmbH is specialised in the construction and development of spectral fluorometers for Toxicity describes harmful effects caused by contact with hazardous com-
the measurement of the chlorophyll content of algal classes with different pigments. The company is pounds. A distinction can be made between acute and chronic toxicity.
also the market leader in the field of biological early warning systems, i.e. toximeters, for the detection Acute Toxicity comprises damaging effects which are visualised within
of environmentally hazardous substances and compounds. a short time after exposure, while chronic toxicity includes long-term
effects. bbe biomonitors focus on the assessment of acute toxicity in
The employees of bbe Moldaenke GmbH form a well-trained and highly motivated team of experts
water to recognise and manage sudden events such as contamina-
with diverse professional backgrounds such as e.g. environmental technology, process technology,
tion, spills. All bbe biomonitors serve as EARLY WARNING SYSTEMS.
electronics, information technology, biology and physics.
Suitable test organisms react immediately to contamination with
Future-oriented projects at bbe Moldaenke GmbH are supported by cooperation with scientific changes in their physiology. The main issue of effective biomo-
institutions. Over the years, knowledge from several research projects and industrial partners has nitors is the perfect interaction of hardware, test organism and
successfully fed into new product developments. bbe sees itself as a socially responsible company: advanced alarm-software. bbe develops these biomonitors on the
water quality monitoring is becoming increasingly significant due to an increasing population and basis of scientific knowledge about algae, daphnia and fish to span the
shrinking water reserves. This problem is being tackled internationally by the use of bbe know-how. broad variety of different compounds that may harm human being even
at low levels. This information cannot be provided by chemical analysis.
International cooperation requires a presence at many locations simultaneously outside Germany.
Establishing a network of representative and distributors in more than 37 countries has gone a long way
to meeting these requirements. You can find our bbe products on site 13 to 15

4 About us  |  bbe moldaenke © bbe moldaenke ©  |  About Chlorophyll & Toxicity 5
Chlorophyll Chlorophyll
AlgaeTorch BenthoTorch

Features Features
▶▶ Simultaneous determination ▶▶ Simultaneous determination
of total chlorophyll and of benthic green and blue-
blue-green algae green algae, and diatoms
The user-friendly, handheld measuring instrument: ▶▶ Automatic turbidity In-situ measuring instrument for the rapid and simple ▶▶ No sample-taking or
correction for reliable preparation
switch on – dip in – read off! chlorophyll determination determination of the chlorophyll of benthic algae
▶▶ Easy to use
The bbe AlgaeTorch is a light handheld measuring instrument for the ▶▶ GPS for exact location of The bbe BenthoTorch is a reasonably priced instrument for the measure- ▶▶ Display for operation
simultaneous detection of the chlorophyll-a of blue-green algae (cyano- measuring site ment of benthic algae concentrations in real time. It enables the immediate and measurement results
bacteria) and the total chlorophyll-a content of all microalgae present in the ▶▶ No sample-taking or and reliable determination of algal growth for the estimation of primary ▶▶ Internal data storage
water. The measurement of chlorophyll-a fluorescence can replace labo- preparation necessary production and for the analysis of ecological status (in accordance with
▶▶ GPS sensor
ratory analysis. A complete measurement requires less than 15 seconds. ▶▶ Easy to use the EU Water Framework Directive). The portable field instrument mea-
Sample-taking and preparation are unnecessary. With capacitive keys on sures in vivo chlorophyll fluorescence in situ on different substrates such ▶▶ Automatic measurement
▶▶ Result display on the
correction depending on
the housing the AlgaeTorch is simple and easy to use. The instrument is instrument, internal as stones or sediments without any sample preparation. The BenthoTorch substrate
robust and waterproof and can be deployed down to depths of 10 m for data memory calculates biomass on the basis of the chlorophyll-a content and deter-
▶▶ Cable-free operation due
short periods (AlgaeTorch 10). Using a modified plug system, the Algae- ▶▶ Built-in pressure sensor mines the distribution of the different algal classes. An individual mea- to internal rechargeable
Torch 100 can be deployed for long periods down to depths of 100 m. The (AlgaeTorch 100) surement takes approximately 20 seconds. The calculation is performed in batteries
AlgaeTorch uses the in vivo fluorescence of the algal cells. The algal pig- ▶▶ Underwater cable of the instrument by using an optimised algorithm. The results are displayed ▶▶ USB-connection for data
ments are excited selectively by LEDs and emit red fluorescence light as a 10-30 m (AlgaeTorch 100) directly after the measurement on the display and stored internally. Data transfer to external PC
natural phenomenon. The intensity of the chlorophyll fluorescence is used transfer to a PC is performed via the USB interface using the data cab-
to determine the different algal classes, in this case blue-green algae or Applications le supplied. The bbe++ software for subsequent evaluation and graphic
Applications
the total chlorophyll of microalgae. representation of the data is supplied free of charge.
▶▶ Investigation according to the
▶▶ Estimation of primary
EU Water Framework Directive
production
Specifications and Bathing Water Directive
▶▶ Monitoring of water quality
Specifications ▶▶ Determination of
ecological status
DESCRIPTION Value in seas and rivers
DESCRIPTION Value ▶▶ Rehabilitation/sanitation
Total chlorophyll [µg chl-a/l], ▶▶ Detection of algal blooms
Measurands projects
blue-green algae [µg chl-a/l] and blue-green algae Measurands
Total chlorophyll [µg chl-a/cm²], blue-green algae
(cyanobacteria) [µg chl-a/cm²], diatoms [µg chl-a/cm²] ▶▶ Environmental monitoring
Measurement range 0 – 200 µg chl-a/l
Measuring range 0 – 15 µg chl-a/cm²
Resolution 0.1 µg chl-a/l ▶▶ Warning of possible toxins ▶▶ Limnological analysis
Resolution 0.1 µg chl-a/cm²
Weight 1.3 kg ▶▶ Management of reservoirs ▶▶ Research and teaching
and dams Weight 1.3 kg
Dimensions (H x Ø) 500 x 60 mm
Dimensions (H x Ø) 500 x 60 mm
Protection IP 68
Protection class IP 68
Voltage 230 V / 50 Hz; 110 V / 60 Hz; or 12 V DC
Voltage 230 V / 50 Hz; 110 V / 60 Hz; or 12 V DC
Power consumption 10 W
Power consumption 10 W
Temperature Sample: 0 to 35 °C / Environment: 0 to 40 °C
Temperature Sample: 0 to 35 °C / Environment: 0 to 40 °C
AlgaeTorch 10: 10 m
Measurement Depth
AlgaeTorch 100: 100 m Depth 10 m

Interface USB Interface USB


10 m rope, telescopic rod, nylon shoulder bag, 10 m rope, telescopic rod, nylon shoulder bag,
Options Options
SDI-12 using the bbe converter SDI-12 using the bbe converter The BenthoTorch used to measure algal classes
AlgaeTorch measurement on site and their concentration on a stone surface

6 AlgaeTorch  |  bbe moldaenke © bbe moldaenke ©  |  BenthoTorch 7


Chlorophyll Chlorophyll
FluoroProbe III AlgaeLabAnalyser

Features Features
▶▶ Measurement of green algae, ▶▶ Quick, simple chlorophyll
blue-green algae (cyanobacte- measurement with algal
ria), diatoms, dinoflagellates class differentiation
and cryptophyceae
Determination of chlorophyll concentrations, algal ▶▶ Maintenance-free
The depth-profiling instrument for the rapid ▶▶ Up to 4 additional algal
classes and photosynthetic activity for science and ▶▶ Simple operation
classes can be calibrated
analysis of chlorophyll content and algal classes routine analysis ▶▶ Direct measurement
▶▶ Up to 4 measurements
without sample preparation
The bbe FluoroProbe III is a highly sensitive measuring instrument for the in per second The bbe AlgaeLabAnalyser offers the simultaneous determination of by filtration or dissolution
vivo analysis of chlorophyll in real microalgae and blue-green algae (cyano- ▶▶ Yellow substances measure- chlorophyll concentrations, transmission, and – as an option – the photo- ▶▶ Laptop supplied
bacteria). Individual profiles for the different algal classes are created during ment and compensation of synthetic activity of microalgae in a 25 ml glass cuvette. The chlorophyll
the measurement. The algal content is determined by evaluating the chloro- disturbances via UV-LED ▶▶ Integrated stirrer
excitation content is excited by coloured LEDs and allocated to the different
phyll fluorescence in real time. Without the necessity of using a laboratory, it algal classes. The AlgaeLabAnalyser enables direct measurement without ▶▶ PC operation with bbe
is possible to completely analyse the occurrence and distribution of algae in ▶▶ Turbidity compensation software
sample preparation by filtration or solvent. The fluorescence signals
(optional)
different water bodies, if necessary at different depths. Interference from e.g. f0, f, fm are used to calculate the photosynthetic activity using the Genty ▶▶ Simple data export
humic substances is compensated using the integrated yellow substances ▶▶ Reduces the number of
parameter method. A yellow substances (CDOM) correction is also used to ▶▶ Optional transport case
microscopic laboratory
measurement. The optional, automatic turbidity correction is unique among correctly calculate the total chlorophyll content. The device is virtually main- ▶▶ Optional external
analyses
fluorometers and makes chlorophyll determination with the bbe FluoroProbe tenance-free and very simple to operate thus saving both time and money. rechargeable battery
▶▶ Internal rechargeable
even more reliable. for mobile deployment
batteries for independent
measurement
Specifications ▶▶ Internal data logger Specifications Applications
▶▶ PC software for data analysis ▶▶ Monitoring and assessment
DESCRIPTION Value DESCRIPTION Value
of water quality
Total chlorophyll [µg chl-a/l], green algae [µg chl-a/l], Total chlorophyll [µg chl-a/l], green algae [µg chl-

Measurands
blue-green algae [µg chl-a/l], diatoms [µg chl-a/l], crypto- Applications a/l], blue-green algae [µg chl-a/l], diatoms [µg chl- ▶▶ Environmental monitoring
phyceae [µg chl-a/l], yellow substances correction, water Measurands a/l], cryptophyceae [µg chl-a/l], yellow substances
temperature (optional), transmission (optional), depth correction, transmission (at 5 wavelengths), ▶▶ Intake monitoring
▶▶ Research in limnology photosynthetic activity (Genty) – optional
Measuring range 0 – 200 µg chl-a/l and oceanography ▶▶ Chemical monitoring
Measuring range 0 – 200 µg chl-a/l
Resolution 0.01 µg chl-a/l ▶▶ Reservoir monitoring ▶▶ Toxicity tests
Resolution 0.01 µg chl-a/l
Transmission 0 – 100 % ▶▶ General environmental ▶▶ Analysis of contaminated
Transmission 0 – 100 %
assessment sites
Weight 6.4 kg (7.2 kg incl. light screen, 4.2 kg in water)
Weight 7.5 kg
▶▶ Monitoring of bathing ▶▶ Monitoring of dams
Dimensions (H x Ø) 490 x 140 mm
water for blue-green algae Dimensions (H x B x T) 220 x 370 x 400 mm
▶▶ Limnological work
Protection class IP 68
▶▶ Monitoring of blue-green Protection class IP 54
Voltage 12 V
▶▶ Research and teaching
algae in drinking water Voltage 230 V / 50 Hz; 110 V / 60 Hz
Battery capacity 3900 mAh ▶▶ Oceanography
▶▶ Aqua culture monitoring Power consumption 10 W
Operating time continually < 10 hrs; interval < 30 days ▶▶ Laboratory tests
Temperature Sample: 0 to 35 °C / Environment: 0 to 40 °C
Temperature Sample: -2 to 40 °C / Environment: -2 to 40 °C
Sample volume 25 ml (cuvette)
Interface RS485 and USB
Interface RS232
Bluetooth set
0 – 100 m (standard), 0 – 300 m (extended range) with handheld
Maximum depth Software bbe++ database software
0 – 1000 m (FluoroProbe “Metal Shell”) device (e.g. Measurement is
smartphone) performed in a
Cuvette holder (Workstation 25), 2-100 m measuring for data Genty, battery pack, SDI-12 with bbe converter, 25ml glass cuvette
Options Options
cables, Hydro-Wiper, Bluetooth-Set display and 12V adapter, transport case and takes approx.
control 1 minute

8 FluoroProbe III  |  bbe moldaenke © bbe moldaenke ©  |  AlgaeLabAnalyser 9


Chlorophyll Chlorophyll
AlgaeOnlineAnalyser AlgaeGuard

Features Features
▶▶ Quick, simple chlorophyll ▶▶ Quick, simple chlorophyll
determination with algal measurement with algal
class differentiation class differentiation
Online determination of chlorophyll concentra- ▶▶ Monitoring of algae ▶▶ Direct measurement
tions, algal classes and photosynthetic activity around the clock Simple and rapid determination of chlorophyll in without sample preparation
▶▶ Determination of photo- flow-through mode ▶▶ Simple operation with
The bbe AlgaeOnlineAnalyser is deployed in measuring stations and synthetic activity (option) little maintenance
laboratories in which online measurement of water quality is required for ▶▶ Little maintenance The bbe AlgaeGuard is conceived as a “plug & play” device: measurements ▶▶ Many communication
rivers, reservoirs, dams and lakes as well as in drinking water production. are automatically started using pre-defined parameters (auto-start func- options also in industrial
▶▶ Simple operation
The instrument impresses due to its rapid analysis of chlorophyll concen- tion) or by pressing the start button on the touchscreen display. In vivo applications
▶▶ Direct measurement chlorophyll fluorescence measurement is comparable to wet chemical
trations. The chlorophyll concentration, the transmission and optionally ▶▶ Integrated cleaning unit
without sample preparation
the photosynthetic activity are determined simultaneously. The detection chlorophyll analysis. The algal classes are determined simultaneously for measuring chamber
by filtration or solvents
of different algal classes by excitation with coloured LEDs distinguishes and recorded as green algae, blue-green algae, brown algae (diatoms and prevents biofilm formation
▶▶ Communication possibilities
this measuring instrument from its competitors. Part of the analysis is a dinoflagellates) and cryptophyceae. To improve the chlorophyll measure- ▶▶ Touchscreen display
in industrial fields
yellow substances (CDOM) measurement to adjust the calculation of the ment the humic substances content is determined and automatically used ▶▶ PC operation with
▶▶ RS232, LAN, USB
total chlorophyll content. The integrated cleaning unit protects against for the correction. The current measurement data are shown on the dis- bbe software
▶▶ Integrated cleaning unit play. A comprehensive analysis and evaluation of the data measured can
growth problems during long-term measurement.
for measuring chamber
be carried out by using the supplied bbe++ software and an external PC. Applications
Specifications Applications ▶▶ Cooling and production
water monitoring
▶▶ Online water quality
DESCRIPTION Value ▶▶ Monitoring of raw water in
assessment Specifications drinking water production
Total chlorophyll [µg chl-a/l], green algae [µg chl-
▶▶ Environmental monitoring
a/l], blue-green algae [µg chl-a/l], diatoms [µg chl- ▶▶ Industrial plants
Measurands a/l], cryptophyceae [µg chl-a/l], yellow substances ▶▶ Intake monitoring DESCRIPTION Value
correction, transmission (at 5 wavelengths), ▶▶ Lake and river monitoring
photosynthetic activity (Genty) – optional ▶▶ Chemical assessment Total chlorophyll [µg chl-a/l], green algae [µg chl-a/l]
Measurands blue-green algae [µg chl-a/l], diatoms [µg chl-a/l] cryp- ▶▶ Chlorophyll measurements
Measuring range 0 – 200 µg chl-a/l ▶▶ Reservoir monitoring tophyceae [µg chl-a/l], yellow substances correction in oceanography
Resolution 0.01 µg chl-a/l Measuring range 0 – 200 µg chl-a/l
▶▶ Cooling and production ▶▶ Environmental monitoring
Transmission 0 – 100 % water monitoring Resolution 0.05 µg chl-a/l
▶▶ Research and teaching
Weight 19 kg ▶▶ Limnological work Weight 16 kg

Dimensions (H x B x T) 420 x 600 x 200 mm ▶▶ Research and teaching Dimensions (H x B x T) 420 x 500 x 200 mm

Protection class IP 54 Protection class IP 54

Voltage 230 V / 50 Hz; 110 V / 60 Hz Voltage 230 V / 50 Hz; 110 V / 60 Hz

Power consumption 100 W Power consumption 30 W

Temperature Sample: 0 to 35 °C / Environment: 0 to 40 °C Temperatur Sample: 0 to 35 °C / Environment: 0 to 40 °C

Sample volume 30 ml Sample volume 30 ml

Maintenance > 7 days Maintenance interval > 14 days

PC PC with touchscreen, Windows Software bbe++ database software


Genty, modem, up to 16 4-20 mA and 16 digital Screenshot of the included and preinstalled RS232, MODBUS, up to 16 4-20 mA and 16 digital
Options Options
outputs, SDI-12 with bbe converter, valve switch bbe software for the analysis and display of the outputs, SDI-12 with bbe converter Screenshot of bbe++ software on
measured data external PC

10 AlgaeOnlineAnalyser  |  bbe moldaenke © bbe moldaenke ©  |  AlgaeGuard 11


Chlorophyll Toxicity
IOcells AlgaeToximeter II

Features Features
▶▶ Field instrument with ▶▶ Highest sensitivity in the
the highest sensitivity detection of herbicides
on the market and their by-products
▶▶ Detection range of one ▶▶ Evaluation of photosyn-
Simple, quick and highly sensitive – the first choice living algal cell/ml The online instrument for the detection of toxic thetic activity of standard
for ballast water assessment! ▶▶ No use of chemicals substances and herbicides in water algae
▶▶ Sensitive to a wide range
▶▶ Measuring time of less The bbe AlgaeToximeter II continually monitors water for toxic substances
With the bbe 10cells device we have used our manufacturing experience of toxic compounds
than one minute
of more than 2 decades of chlorophyll instrument production to venture and determines the algal classes present. Standardised algae are mixed ▶▶ Controlled independent
▶▶ Robust with the sample water and their photosynthetic activity is determined fluo-
into new measurement dimensions – the detection of single living algal algae breeding
cells. Microalgae are an ideal indicator in many applications since they ▶▶ Simple operation rometrically. Damage to the algae – e.g. by herbicides – causes a reduction ▶▶ Antifouling system due
make up the largest part of the biomass of small organisms. The I0cells ▶▶ 10“ Display in photosynthesis and triggers an alarm above a user-defined threshold. to automatic cleaning
is thus always the right choice when the smallest possible algal concen- Optionally, the sensitivity can be tested using a reference toxin. The results of chamber
▶▶ Data logger function
tration has to be detected. The determination of the amount of algae is are comparable with the algae production test; they are however obtained ▶▶ Auto-start after
▶▶ Portable operation using
an ideal parameter for ballast water quality assessment. Using a modified within a significantly shorter time due to the measurement technology. power failure
batteries
PAM procedure (patent) the 10cells achieves a very low detection rate The bbe AlgaeToximeter II works with a double sample loop for sample ▶▶ Automatic turbidity
of only one living cell per ml. Thus, it is 10 times more sensitive than the incubation and allows a short measuring cycle. The recorded data are correction
Applications synchronised and evaluated with an external PC.
limit required by the IMO (International Maritime Organization) and up to ▶▶ Software settings
100 times more sensitive than any other commercially available ballast according to
Harbour Authorities: customer’s needs
water analysis instrument. Other typical applications are process control
▶▶ Quick tests
for drinking water production in waterworks or cooling water production
Specifications
in industrial plants. In daily use, the 10cells supports the controlled and ▶▶ Conceived for portable use Applications
efficient dosing of flocculants or biocides. DESCRIPTION Value
BWT Plant Production: ▶▶ Drinking water supply
Photosynthetic activity and inhibition, total chlo- ▶▶ Reservoirs and intake
▶▶ Helps to achieve correct Measurands rophyll, chlorophyll of 4 algal classes [µg chl-a/l],
dosing of Cl2, ClO2, O3 and UV yellow substances, transmission monitoring
Specifications radiation
Chlorophyll 0 – 200 µg chl-a/l ▶▶ Waterways monitoring
▶▶ Improves the efficiency of and assessment
Transmission 0 – 100 %
DESCRIPTION Value treatment plants ▶▶ Chemical and wastewater
Chamber cleaning Automatic cleaning piston
Measurands Living algae cells
assessment
Ship Owners: Weight 105 kg
Measuring range 1 – 20,000 cells per ml
▶▶ Research and teaching
▶▶ Cost reduction due to detec- Dimensions (H x B x T) 1100 x 600 x 680 mm
Detection limit 1 cell per ml (depending on filtrated volume) tion of IMO-conform ballast Protection class IP54
Weight 4.9 kg water treatment
Voltage || Power 110/240 V; 50/60 Hz || 600 W
Dimensions (H x B x T) 30 x 34 x 15 cm
Temperature Sample: 0 to 30 °C / Environment: 0 to 28 °C
IP54 with closed case
Protection class Sample volume min. 100 ml
IP22 with open case
Voltage 100 – 240 V / 50 – 60 Hz Maintenance interval > 7 days

Filter 8 µm standard (min. 0.2 µm) Sample inlet free inlet / tube pump

Sample: 5 to 35 °C / Environment: 5 to 40 °C IOcells PC (operating system) Windows


Temperatur
(short-term) built into
a robust Modem, LAN, 2x analogue outputs 4 – 20 mA,
Software bbe I0cells-Software case for
Outputs Sample water is mixed with the algae test
2x relay outputs, RS232
mobile use solution and then analysed

12 IOcells  |  bbe moldaenke © bbe moldaenke ©  |  AlgaeToximeter II 13


Toxicity Toxicity
DaphniaToximeter II ToxProtect64

Features Features
▶▶ 1- or 2-chamber system ▶▶ Sensitive to a high
number of toxins
▶▶ Simple operation
▶▶ Reliable
▶▶ Easy maintenance of
Biological early warning system with daphnia and daphnia, genetically ▶▶ Easy to operate
Rapid and reliable detection of toxins
computer-controlled video evaluation defined daphnia stem
in the water supply ▶▶ Low maintenance
▶▶ Integrated, automatic
The bbe DaphniaToximeter II observes daphnia (also known as water fleas ▶▶ Low acquisition and
feeding device The bbe ToxProtect64 is a fully automatic monitoring system to protect drin-
– Daphnia magna) under the influence of a continuous flow of sample operation costs
▶▶ Touchscreen PC with king water supplies from unintentional or intentional contamination by to-
water and evaluates the occurrence of toxic substances using a sensitive ▶▶ Alarms possible via SMS
graphic display of xins. The characteristics of such threats are suddenly occurring, high concen-
alarm analysis. A CCD-camera records the behaviour of the daphnia, which or e-mail
measuring values,
live images and intuitive trations of hazardous substances. Changes in water quality must be detected ▶▶ Threshold for alarm
are kept in a chamber fed with sample water (0.5-2 l/h). The live images
user accounts quickly and safely. One of the best organisms for this purpose is fish, which trigger individually
are evaluated by the internal PC and investigated for changes in the swim-
are kept in the flow-through aquarium of the ToxProtect64. The aquarium of adjustable
ming behaviour. Statistically significant changes in swimming behaviour ▶▶ Simple maintenance
with easily accessible the ToxProtect64 is equipped with light barriers to measure the activity of the ▶▶ Type of fish determined
trigger an alarm in the instrument. The control and monitoring of the in-
instrument module fish, thus determining their swimming behaviour by calculating the number by the user
strument can also be carried out remotely.
▶▶ Sample preparation of times they swim between the light sensors. This information is used to ana- ▶▶ Cyanide alarm within
via ultrasonic filter lyse their health status and therefore the water quality. If the behaviour of the 10 min at 1 ppm
▶▶ Separate compartments fish changes due to contamination of the water, the instruments triggers an ▶▶ Internal sensors indicate
for flow-through chamber alarm. Error alarms in the ToxProtect64 are reduced to an absolute minimum. possible error functions
Specifications and electronics This improves the confidence of operators and avoids unnecessary tasks.

DESCRIPTION Value
▶▶ Remote access (optional) Applications
Specifications ▶▶ Waterworks
Mean swimming speed, speed distribution,
swim height, average distance, fractal dimension Applications
Measurands of the swim paths, swim paths, number of ▶▶ Reservoir monitoring
daphnia, distribution in the chamber, size of ▶▶ Drinking water production DESCRIPTION Value
the daphnia ▶▶ Surveillance of the drinking
▶▶ Process water surveillance Measurands Activity, position and length of stay at location water distribution network
Chamber cleaning Automatic cleaning piston
64 light barriers to detect fish movements,
▶▶ Reservoir and intake Sensors
30 light barriers to detect immobilised fish
▶▶ Intake surveillance
Camera CCD-camera
monitoring
Weight 50 kg ▶▶ Chemical assessment
Weight 60 kg
▶▶ Waterways monitoring
Dimensions (H x B x T) 800 x 790 x 444 mm
Dimensions (H x B x T) 800 x 800 x 500 mm and assessment
Protection class IP54 Protection class IP54
▶▶ Chemical assessment
Voltage || Power 110/240 V; 50/60 Hz || 600 W Voltage || Power 110/240 V; 50/60 Hz || 200 W
▶▶ Research and teaching
Temperature Sample: 0 to 30 °C / Environment: 0 to 35 °C Temperature Sample: 5 to 26 °C dep. on fish / Environment: 0 to 35 °C

Sample volume 30 ml, 0.5 – 2 l/h, for filtration/ultrasonic 200l/h Sample volume 9l

Maintenance interval > 7 days Maintenance interval > 7 days

Sample inlet Free inlet / tube pump Fish feed Automatic feeding unit

Integrated touchscreen PC, ultrasonic cleaning Numbers of fish 15 – 20 (4 – 6 cm length)


Features
unit, algae feed syringe The daphnia Sample inlet Pressured tube 1 bar
behaviour in
Modem, LAN, 2x analogue outputs 4 – 20 mA, 2x sample water
Outputs Design Embedded PC, 17” touchscreen display, Windows
relay outputs, RS232 is observed in The ToxProtect64 monitors the
the measuring swimming activity of fish in an
Options 2-chamber system, remote access chamber by a Outputs GSM, LAN aquarium fed with drinking or
CCD camera mains water

14 DaphniaToximeter II  |  bbe moldaenke © bbe moldaenke ©  |  ToxProtect64  15


bbe Moldaenke GmbH
Preetzer Chaussee 177
24222 Schwentinental
Germany

Tel.: +49 (0) 431 - 380 40-0


Fax: +49 (0) 431 - 380 40-10
Your local distributor
[email protected]
www.bbe-moldaenke.de

You might also like