CT Calc Tool V1.2

This document provides specifications for various current transformers (CTs) including their accuracy class, internal diameter or maximum space for different types of cables or bars, as well as any part numbers and power consumption ratings. It notes that for the given cable length and section, the total power consumption including safety coefficient would be 0.84 VA. The CT ratio provided is 2. No CTs are available for the given NSX breakers or with a maximum size of 2.5 mm2.

Uploaded by

Khay Saad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
151 views3 pages

CT Calc Tool V1.2

This document provides specifications for various current transformers (CTs) including their accuracy class, internal diameter or maximum space for different types of cables or bars, as well as any part numbers and power consumption ratings. It notes that for the given cable length and section, the total power consumption including safety coefficient would be 0.84 VA. The CT ratio provided is 2. No CTs are available for the given NSX breakers or with a maximum size of 2.5 mm2.

Uploaded by

Khay Saad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 3

Type of meter 9

Cable lenght /2 [m] 1.00


Cable section [mm2] 3
Cable consumption per meter [VA] 0.41
Total cable consumption 0.41
Meter consuption [VA] 0.15

Total consumption [VA] 0.56


Safety coeff 50%
Total consumption [VA] + 50% 0.84

CT ratio 2

Smallest CT available for CABLES CT internal Diameter [mm]


Acc class 0.5 0
Acc class 1 21
Acc class 3 21

Smallest CT available for BARS Max. space for bar [mm]

Acc class 0.5 0


Acc class 1 0
Acc class 3 0

CT block for NSX breakers Part number


Acc class 3 NO CT AVAILABLE

CT block with voltage output block for NSX breakers Part number
Acc class 0.5 NO CT AVAILABLE
Acc class 1 NO CT AVAILABLE

Split-core CT Part number


Acc class 1 NO CT AVAILABLE
Max size [mm2] 2.5

Part number [VA]


NO CT AVAILABLE 0
METSECT5CC005 1.25
METSECT5CC005 1.5

Part number [VA]

NO CT AVAILABLE 0
NO CT AVAILABLE 0
NO CT AVAILABLE 0

Part number [VA]


NO CT AVAILABLE 0

Part number [VA]


NO CT AVAILABLE 0
NO CT AVAILABLE 0

Part number [VA]


NO CT AVAILABLE 0