This document describes a compact programmable potentiometer transmitter. It has the following key features: - Field-rangeable with wide switchable input and output ranges. - High accuracy of 0.1% full scale. - Optional 3-way isolation between input, output, and power. - It can be programmed through function switches to set the input range, output mode, and other parameters. Detailed programming instructions and application examples are provided.

Uploaded by

Bowo AS
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
186 views2 pages

Potentiometer Transmitter PF-KCBP

This document describes a compact programmable potentiometer transmitter. It has the following key features: - Field-rangeable with wide switchable input and output ranges. - High accuracy of 0.1% full scale. - Optional 3-way isolation between input, output, and power. - It can be programmed through function switches to set the input range, output mode, and other parameters. Detailed programming instructions and application examples are provided.

Uploaded by

Bowo AS
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

COMPACT PROGRAMMABLE POTENTIOMETER TRANSMITTER

FEATURES
• Field-rangeable. Wide switchable input ranges 200 to 50KΩ, Wide switchable
output ranges over 20 standard process ranges.
• Accuracy 0.1%F.S.
• 3-way isolation, input/output/power (optional)
• Optical isolation with 2KVac/1 min for Input/Output (optional)

1. MODEL: PF-= =J= = =J= =J=


N Non-programmable
Blank Programmable
KCAP Non-Isolating (input/output)
KCBP Isolating (input/output)

NO Ranges RL~RH NO Output Voltages/Current NO Aux. Power


10 0 ~ 10 % A 0 ~ 0.5 V 1 AC 100V~240V ± 10 %
11 0 ~ 15 % B 0~1 V 2 DC 20V~70V ± 10 %
12 0 ~ 20 % C 0~2 V 3 DC 110V ± 10 %
13 0 ~ 25 % D 0~4 V 4 DC 220V ± 10 %
14 0 ~ 30 % E 0~5 V 5 DC/AC 24V ± 10 %
15 0 ~ 40 % F 1~5 V 9 SPECIFIED
16 0 ~ 50 % G 0~8 V
17 0 ~ 60 % H 0 ~ 10 V
18 0 ~ 70 % I 2 ~ 10 V
19 0 ~ 80 % J 0~1 mA
20 0 ~ 90 % K 0~2 mA
21 0 ~ 100 % L 0~5 mA
22 5 ~ 95 % M 1~5 mA
23 10 ~ 90 % N 0 ~ 10 mA
24 10 ~ 100 % O 0 ~ 16 mA
99 SPECIFIED P 0 ~ 20 mA
• Max. output current 100mA Q 4 ~ 20 mA
R SPECIFIED

• S3 =Input range span (GAIN) selection


2. Specification
• Accuracy : 0.1% F.S. (23±5°C)
• Output ripple (p-p) : <0.1% F.S. ON
• Temp. coefficient : 100ppm/°C (0-50°C) 1 2 3 4 5 6 7 8
• Exciting voltage : DC 2.5V (≤60mA)
• Power consumption : ≤4.7VA (AC power) OFF
• Dielectric strength : 1.5KVac/1 min. (power/input/output)
1600Vdc (input/output) N% 1 2 4 8 10 20 40 80
• Output drive capability : ≤20mA for voltage mode Status off = enable
≤14V for current mode All poles off ∑N = 165%
• Response time : ≤200ms (0~90%) All poles on ∑N = 0%
• Operating condition : 0~55°C humidity 20~95% RH
non-condensed
• S4 =Ouput mode Selection
• Storage condition : 0~70°C humidity 20~95% RH
non-condensed

3. Function switches (S2, S3, S4) ON


1 2 3 4 5 6 7 8
• S2 =Input range offset (ZERO) selection
ON OFF
1 2 3 4 5 6 7 8

Status on = 1, off = 0
OFF
N% 1 2 4 8 10 20 40 80
Status off = enable
All poles off ∑N = 165%
All poles on ∑N = 0%
64
COMPACT PROGRAMMABLE POTENTIOMETER TRANSMITTER
• S4 =Ouput mode Selection
6. Input switching table (S2, S3)
(Status–on =1, off = 0, don’t care = X)
ON
1 2 3 4 5 6 7 8 Input range S2 (ZERO) S3(SPAN)
1-2-3-4-5-6-7-8 1-2-3-4-5-6-7-8
0~10 % 1-1-1-1-1-1-1-1 1-1-1-1-1-0-1-0
OFF 0~15 % 1-1-1-1-1-1-1-1 *0-0-0-1-1-0-0-1
0~20 % 1-1-1-1-1-1-1-1 1-1-1-1-0-1-0-1
Status ON =1,OFF=0 0~25 % 1-1-1-1-1-1-1-1 1-1-1-1-1-1-0-1
0~30 % 1-1-1-1-1-1-1-1 *0-0-1-1-0-0-1-1
0~40 % 1-1-1-1-1-1-1-1 0-1-0-1-1-0-1-1
Output Range O/P Range O/P Mode 0~50 % 1-1-1-1-1-1-1-1 1-1-1-1-1-0-1-1
1-2-3-4-5-6 7-8 0~60 % 1-1-1-1-1-1-1-1 *0-0-0-1-0-1-1-1
0 ~ 0.5V 0-1-1-1-1-0 1-1 0~70 % 1-1-1-1-1-1-1-1 *1-1-0-1-0-1-1-1
0 ~ 1V 1-0-1-1-1-0 1-1 0~80 % 1-1-1-1-1-1-1-1 *0-0-1-1-0-1-1-1
0 ~ 2V 1-1-0-1-1-0 1-1 0~90 % 1-1-1-1-1-1-1-1 *0-1-1-1-0-1-1-1
0 ~ 4V 1-1-1-0-1-0 1-1 0~100% 1-1-1-1-1-1-1-1 1-1-1-1-0-1-1-1
0 ~ 5V 1-0-1-0-1-0 1-1 5~95 % 0-1-0-1-1-1-1-1 *0-1-1-1-0-1-1-1
1 ~ 5V 1-1-1-0-1-1 1-1 10~90% 1-1-1-1-0-1-1-1 *0-0-1-1-0-1-1-1
0 ~ 6V 1-1-0-0-1-0 1-1 10~100 % 1-1-1-1-0-1-1-1 0-1-1-1-0-1-1-1
0 ~ 8V 1-1-1-1-0-0 1-1
* Recalibration to obtain linear output
0 ~ 10V 1-1-0-1-0-0 1-1
2 ~ 10V 1-1-1-1-0-1 1-1
0 ~ 1mA 0-1-1-1-1-0 0-0
0 ~ 2mA 1-0-1-1-1-0 0-0 7. Application
0 ~ 5mA 0-1-0-1-1-0 0-0 Example: PF-KCBP-21Q-1
1 ~ 5mA 1-1-0-1-1-1 0-0
0 ~ 10mA 1-0-1-0-1-0 0-0
2 ~ 10mA 1-1-1-0-1-1 0-0 INPUT RANGE……RH=100%, RL=0%
0 ~ 16mA 1-1-1-1-0-0 0-0 OUTPUT……………DC 4 ~ 20 mA
0 ~ 20mA 1-1-0-1-0-0 0-0 POWER…………….AC 100 ~ 240V
4 ~ 20mA 1-1-1-1-0-1 0-0
S2…………………..All poles ON  ∑N=0%
S3…………………..P5-OFF & the rest ON  ∑N=10%
S4…………………..P5-P7-P8-OFF & the rest ON
4. Programming formula
RH/RL: percent input high/percent input low
• Span  X=[10/(RH-RL)] %
• Offset  Y=(100xRL) % 8. Dimension:

5. Terminal connection

99mm
50mm

22.5mm
112.6mm

65