Archictect Drawing 2
Archictect Drawing 2
Archictect Drawing 2
File: newport_TD_1_1.dwg
GENERAL:
ue Black slates, by Tegral or similar Slated roofs to be of Thrutone Blue Black slates, by Tegral or similar ALL FINISHES AND FITTINGS TO BE AGREED WITH CLIENT.
verges & permanent proprietary over approved, with dry-fixed ridge & verges & permanent proprietary over
oughout, on 50mm x 35mm treated facia & ridge level ventilation throughout, on 50mm x 35mm treated ALL HABITABLE ROOMS TO BE VENTILATED.
ble roofing underlay on Ex 200x50mm timber cross battens on breathable roofing underlay on Ex 200x50mm
s @ 400mm ctrs, on treated timber wall Grade C18 treated timber rafters @ 400mm ctrs, on treated timber wall PROVIDE FOR THE CONTAINMENT OF RADON GAS IN ACCORDANCE
d wall plate straps along verges & plates with proprietary galvanised wall plate straps along verges & WITH CURRENT BUILDING REGULATIONS.
1780x780mm VELUX "INTEGRA" manually operated
18 treated timber ceiling joists @ eaves & Ex 200x50mm Grade C18 treated timber ceiling joists @ GGL306021U Pine framed rooflighst with --60 Pane
proprietary slating edge trim. 400mm ctrs. All verges to have proprietary slating edge trim. ALL STRUCTURAL TIMBERS TO COMPLY WITH SR 11 TABLES.
glazing and BDX Insulation Collar. 2 Nr indicated to
serve as emergency escape windows
Emergency Escape Rooflight ALL WORK TO BE CARRIED OUT AND ALL MATERIALS USED TO
COMPLY WITH CURRENT BUILDING REGULATIONS.
Black uPVC Gutters & Downpipes Emergency Escape Rooflight DO NOT SCALE FROM THIS DRAWING.
F.F.L. 104.090m F.F.L. 104.090m
Eaves Level 103.890m Eaves Level 103.890m Eaves Level 103.890m BUILDER IS TO TAKE RESPONSIBILITY FOR ALL ASPECTS OF SAFETY
ON SITE IN ACCORDANCE WITH CURRENT SAFETY AND HEALTH
Black uPVC Gutters & Downpipes REGULATIONS.
External Render to be of light napp plaster
hs all around finish & smooth plastered plinths all around Frosted glass to all shower & COPYRIGHT TO ALL DRAWINGS REMAIN THE PROPERTY OF MARTIN
dressing room windows throughout SHINNORS ARCHITECT.
External windows & doors to be
uPVC, double glazed, as per schedule N.B. PLEASE REVIEW THE ENCLOSED DRAWINGS CAREFULLY
BEFORE WORK BEGINS ON SITE AND ANY DISCREPENCIES OR
F.F.L. 100.840m F.F.L. 100.840m F.F.L. 100.840m
F.G.L. 100.690m F.G.L. 100.690m F.G.L. 100.690m PROBLEMS RELATING TO THE DRAWINGS OR THE BUILDING WORKS
CONTAINED WITHIN THE DRAWINGS SHOULD BE BROUGHT TO THE
ATTENTION OF THE SUPERVISING ARCHITECT.
FOUNDATIONS
THE FOUNDATIONS MUST HAVE AT LEAST A MINIMUM WIDTH
EQUAL TO THREE TIMES THE THICKNESS OF THE WALL IT IS
SUPPORTING. THE MINIMUM DEPTH OF FOUNDATION EXCAVATION
BELOW FINISHED GROUND LEVEL TO BE 900mm
THE MINIMUM THICKNESS OF CONCRETE TO BE 350mm. ENSURE
THAT ALL BLOCKWORK WALLS ARE BUILT FROM A FOUNDATION.
THE SPECIFICATIONS FOR THE ABOVE ARE BASED ON NORMAL
A B GROUND CONDITIONS
ACO-Drain
floor (to 3-4mm tolerance), on 150mm rigid board
insulation, to minimum thermal conductivity 0.018 W/m.K. External Doors: FIRE SAFETY AND PREVENTION
Minimum 25mm thick rigid board insulation to floor slab W22 All external doors, except glazed uPVC double S3
WC Internal Door Schedule Ref EVERY BEDROOM SHOULD HAVE A WINDOW WHICH CAN BE USED
ACO-Drain
perimeter with 1200 gauge DPM on 50mm blinding on Min doors to main entrance lobby, are to be of solid AS AN ALTERNATIVE MEANS OF ESCAPE. AN ESCAPE WINDOW
225mm well compacted 50mm down hardcore. S11 hardwood, with matching frames, with secure NEEDS TO PROVIDE A CLEAR OPENABLE AREA OF 0.33sq/m WHICH
W9 S10 Steel Post Legend:
locking mechanism & TG&V vertical boarding to SHOULD INCLUDE A MINIMUM WIDTH OR HEIGHT OF 450mm. THE
panels & double glazed night light panels overhead Painted SHS corner post, anchored via BOTTOM OF THE WINDOW OPENING MUST BE NOT MORE THAN
C1
Internal Walls:
baseplate to foundation all to Engineer's details 1100mm AND NOT LESS THAN 800mm (600mm IN THE CASE OF
Internal walls to be unrendered, fair-faced blockwork,
Floor of Storage area to receive 2 coats of ROOFLIGHTS) ABOVE FLOOR LEVEL. A MAINS OPERATED FIRE
with pointed mortar joints, clear of snots, sealed &
floor paint, walls to be dust sealed & ceiling DETECTION AND ALARM SYSTEM MUST BE PROVIDED. BATTERY
painted to selected colour. Internal ceilings to receive Painted UB Column, anchored via baseplate OPERATED SYSTEMS ARE NOT ACCEPTABLE.
C2
to receive 2 coats of paint to selected colour.
ACO-Drain
3mm thick skim plaster finish on 12.5mm plasterboard, to foundation all to Engineer's details
painted to selected colour. S13 DISABLED ACCESS
W8 Seating S12 Seating Painted steel beam
Beam WHEELCAHIR ACCESS TO BE PROVIDED IN ACCORDANCE WITH
All abled-bodied WC's are to receive vandal-proof wash Disabled to Engineer's details
PART M OF THE TECHNICAL GUIDANCE DOCUMENTS 2010.
handbasin, wc pan & cistern, as well as 1 nr electric hand
dryers. All wash hand basins & wc cisterns are to be wall WC
mounted. Disable WC is to receive a full DOC M
sanitaryware pack including all related handrails etc, as
C2
well as 1 nr electric hand dryer C Hallway Wall with inner lobby doors to
have timber stud partition with S15 C
S5
S4 F.F.L. 100.840m skimmed plasterboard to each face S14
W7 W6 W5
Internal Stairs:
1:12 gradient concrete Internal staircase to be of cast in-situ or precast
ramp to threshold concrete, with non-slip finish to threads, to
architect's approval, with toe inserts. Landings,
balusters, handrails, and step rise and going must
W27
C1
W4
External Paths: Up Document Part K for stairs.
C1
C1
ACO-Drain
C2
C2
C2
C2
External Blockwork Piers: Automatically Operated Vent
Piers to consist of painted, rendered 100mm thick (A.O.V.) rooflight over
blockwork wrapped around structural steel columns to stairwell, with 1.5m2 openable
Engineer's details
W1 area & connected to Fire
Emergency Escape Rooflight Alarm System for smoke
ventilation in the case of fire
A
Black uPVC Gutters & Downpipes
1:12 gradient concrete Eaves Level 103.890m
ramp to threshold
B External Render to be of light
napp plaster finish & smooth
Main Entrance, Disabled WC & plastered plinths all around
Store Room to have level access
provided, with a 1:12 gradient External windows & doors
concrete ramp to threshold to be uPVC, double glazed,
as per schedule
F.G.L. 100.690m
File: newport_TD_1_1.dwg
Slated roofs to be of Thrutone Blue Black slates, by PROVIDE FOR THE CONTAINMENT OF RADON GAS IN ACCORDANCE
Tegral or similar approved, with dry-fixed ridge & WITH CURRENT BUILDING REGULATIONS.
verges & permanent proprietary over facia & ridge
level ventilation throughout, on 50mm x 35mm LEGEND: ALL STRUCTURAL TIMBERS TO COMPLY WITH SR 11 TABLES.
treated timber cross battens on breathable roofing
underlay on Ex 200x50mm Grade C18 treated timber ALL WORK TO BE CARRIED OUT AND ALL MATERIALS USED TO
Solid Blockwork Walls COMPLY WITH CURRENT BUILDING REGULATIONS.
rafters @ 400mm ctrs, on treated timber wall plates
with proprietary galvanised wall plate straps along
verges & eaves & Ex 200x50mm Grade C18 treated DO NOT SCALE FROM THIS DRAWING.
Emergency Emergency
Escape Escape timber ceiling joists @ 400mm ctrs. All verges to External Door/Window Schedule Ref W23
Roof Roof have proprietary slating edge trim. BUILDER IS TO TAKE RESPONSIBILITY FOR ALL ASPECTS OF SAFETY
Rooflight Rooflight
Light Light ON SITE IN ACCORDANCE WITH CURRENT SAFETY AND HEALTH
REGULATIONS.
Internal Door Schedule Ref S3
COPYRIGHT TO ALL DRAWINGS REMAIN THE PROPERTY OF MARTIN
SHINNORS ARCHITECT.
Steel Post Legend:
Painted SHS corner post, anchored via N.B. PLEASE REVIEW THE ENCLOSED DRAWINGS CAREFULLY
C1
baseplate to foundation all to Engineer's details BEFORE WORK BEGINS ON SITE AND ANY DISCREPENCIES OR
Internal Wall & Ceiling Finishes: PROBLEMS RELATING TO THE DRAWINGS OR THE BUILDING WORKS
All internal walls & ceilings to be cleaned down, CONTAINED WITHIN THE DRAWINGS SHOULD BE BROUGHT TO THE
Painted UB Column, anchored via baseplate ATTENTION OF THE SUPERVISING ARCHITECT.
C2
prepped, sealed & painted with washable internal
to foundation all to Engineer's details
grade, durable paint to selected colour. All
FOUNDATIONS
internal joinery to be undercoated & then receive Painted steel beam
Beam THE FOUNDATIONS MUST HAVE AT LEAST A MINIMUM WIDTH
two coats of white satinwood paint to Engineer's details EQUAL TO THREE TIMES THE THICKNESS OF THE WALL IT IS
SUPPORTING. THE MINIMUM DEPTH OF FOUNDATION EXCAVATION
C1
C1
C1
Internal Doors: BELOW FINISHED GROUND LEVEL TO BE 900mm
All internal doors are to be oak veneered THE MINIMUM THICKNESS OF CONCRETE TO BE 350mm. ENSURE
Entire First Floor deck to consist of 100mm thick with solid oak veneer panels, to matching THAT ALL BLOCKWORK WALLS ARE BUILT FROM A FOUNDATION.
100x100mm SHS structural steel columns to Engineer's
precast concrete "wideslab" units, with 125mm thick timber frames with NO saddle to floor THE SPECIFICATIONS FOR THE ABOVE ARE BASED ON NORMAL
details, supporting Treated timber purlins under rafters.
cast in-situ concrete, reinforced concrete screed thresholds. GROUND CONDITIONS
Columns to be fixed to 8mm thick base plates, fixed to
concrete screed with anchor bolts (sized to Engineer's over & skimmed 12.5mm thick plasterboarding to
details), in a 40mm deep, sunken pocket in the screed. sofft, on Ex 38x38mm treated timber battens, GROUND FLOOR SLAB
Exposed pocket is to be filled with non-shrink grout shot-fixed into soffit of precast units. S13 S14 External windows & doors to be uPVC, USE GOOD QUALITY HARDCORE EG. CLEAN, WELL GRADED BROKEN
W25 double glazed, as per schedule STONE, 100mm MAX SIZE. COMPACTED IN LAYERS NOT EXCEEDING
upon completion of the works
225mm IN DEPTH. & BLINDED WITH A 50mm COVERING OF SAND.
Ridge Line Overhead Dn A DAMP PROOF MEMBEANE OF AT LEAST 1200 GAUGE MATERIAL TO
BE LAID, WITH JOINTS LAPPED AND SEALED. 100mm HIGH DENSITY
External Render to be of light napp plaster RIGID INSLUATION TO BE PLACED ON TOP OF DAMP PROOF
finish & smooth plastered plinths all around MEMBRANE WITH 25mm HIGH DENSITY INSULATION TO BE PLACED
ALONG EDGE OF FLOOR SLAB.
Internal Floor Finishes:
Storage & Committee Meetings Room F.F.L. 104.090m Upstairs Area to have industrial grade RADON PROTECTION
A SUMP MUST BE PROVIDED WITH CONNECTING PIPEWORK
carpeting, on underlay, to selected colour
TERMINATIONG AND CAPPED AT SUITABLE POINTS OUTSIDE THE
EXTERNAL WALLS OF THE DWELLING. IN SITUATIONS WHERE THE
Internal Stairs:
RADON LEVEL IS UNACCEPTABLY HIGH, AN APPROVED RADON
Internal staircase to be of cast in-situ or precast
BARRIER OF LOW PERMEABILITY SHOULD ALSO BE USED.
concrete, with non-slip finish to threads, to
architect's approval, with toe inserts. Landings, CAVITY WALLS
balusters, handrails, and step rise and going must CAVITY BLOCKWORK CONSTRUCTION TO CONSIST OF 100mm
comply with the current Technical Guidance
C1
C1
C1
INNER BLOCKWORK LEAF, 150mm CAVITY AND 100mm OUTER
Document Part K for stairs. BLOCKWORK LEAF. 100mm THERMAWALL TW100 HIGH DENSITY
INSULATION TO BE PLACED FIRMLY AGAINST OUTER FACE OF INNER
LEAF AND HELD IN POSITION WITH STAINLESS STEEL WALL TIES
A.O.V.:
FITTED WITH INSULATION RETAINERS. ENSURE THAT CAVITY IS
Stairway to have 1.5m smoke vent at KEPT CLEAR FOR BETWEEN 150mm AND 225mm BELOW DPC LEVEL.
ceiling level extracting smoke to outside air ALL WINDOW OPES TO HAVE A FULL DPC "WRAP" PLACED AT
through roof covering . ventilation to HEADS, JAMBS AND CILLS.
comply with bs 5588-9:1999
ROOF
ADEQUATE TRIANGULATION OF THE ROOF SHOULD BE ACHIEVED
AT ALL TIMES. 100 x 75mm WALLPLATE TO BE FIXED TO TOP OF
SUPPORTING WALL WITH GALVANISED STRAPS AT 1.8m CENTRES.
ALL ROOF TIMBERS TO BE TREATED, WITH RAFTERS & CEILING
JOISTS SET AT 400mm CENTRES. TIMBER PURLINS SHOULD BE
PROPPED AT REGULAR INTERVALS. COLLARS TO BE PLACED AT
1600mm CENTRES. VENTILATION TO ROOF SPACE SHOULD BE
ACHIEVED BY PROVIDING THE EQUIVALANT OF 10mm CONTINUOUS
STRIP AT EAVES LEVEL.
DISABLED ACCESS
WHEELCAHIR ACCESS TO BE PROVIDED IN ACCORDANCE WITH
PART M OF THE TECHNICAL GUIDANCE DOCUMENTS 2010.
Storage T T T T
Changing Changing
S Room 2 Room 3
T
T
T
Storage
Storage
T
T
T
Changing T
WC Room 1 Changing S
S S Room 4 Storage & Committee Meetings Room S
T
S S
T
T
T
S S
T
Disabled
T
Seating Seating
T F.F.L. 104.090m
WC All Dressing Room light fittings to
T
be vapour resistant & vandal proof
S S
A.O.V.:
E Hallway
Stairway to have 1.5m smoke vent at E
All Dressing Room radiators are to ceiling level extracting smoke to outside
F.F.L. 100.840m
be low level under-seat mounted T
air through roof covering . ventilation to
comply with bs 5588-9:1999
Up T T T
All external light fittings wall mounted at 1.8m above ffl on wall panels, 2.3m above ffl over door opes
All permanent ventilation is to be provided by means of a proprietary system of grilles & ducts. The use of wavin
pipework off-cuts through external is not permitted.
Entrance
Lobby The Electrical Sub-Contractor is to provide all necessary to complete the electrical installation in accordance with all
current regulations & guidance documents.
The Mechanical Sub-Contractors are to provide all necessary to complete the mechanical installations, in
accordance with all current regulations & guidance documents.
File: newport_TD_1_1.dwg
Roof Finishes:
Slated roofs to be of Thrutone Blue Black slates, by Tegral or similar
approved, with dry-fixed ridge & verges & permanent proprietary over Ground Floor Slab:
facia & ridge level ventilation throughout, on 50mm x 35mm treated 150mm thick, mesh reinforced, power floated concrete
timber cross battens on breathable roofing underlay on Ex 200x50mm floor (to 3-4mm tolerance), on 150mm rigid board
Grade C18 treated timber rafters @ 400mm ctrs, on treated timber insulation, to minimum thermal conductivity 0.018 W/m.K.
wall plates with proprietary galvanised wall plate straps along verges Minimum 25mm thick rigid board insulation to floor slab
& eaves & Ex 200x50mm Grade C18 treated timber ceiling joists @ perimeter with 1200 gauge DPM on 50mm blinding on Min
400mm ctrs. All verges to have proprietary slating edge trim. Attic 225mm well compacted 50mm down hardcore. Attic
External Paths:
Pathway areas to be of 100mm thick mesh reinforced concrete, on 75mm sand
& cement lean mix blinding, except where noted otherwise. All grassed areas to
be soil-prepared, seeded & ready for lawns.
Ridge 109.535m
Roof Finishes:
Slated roofs to be of Thrutone Blue Black slates, by
Tegral or similar approved, with dry-fixed ridge &
verges & permanent proprietary over facia & ridge
level ventilation throughout, on 50mm x 35mm
treated timber cross battens on breathable roofing
underlay on Ex 200x50mm Grade C18 treated timber
rafters @ 400mm ctrs, on treated timber wall plates
with proprietary galvanised wall plate straps along
verges & eaves & Ex 200x50mm Grade C18 treated
timber ceiling joists @ 400mm ctrs. All verges to
External Walls: have proprietary slating edge trim.
All external cavity blockwork walls to be 350mm wide
typically, with 100mm thick solid blockwork rendered outer
leaf, painted to selected colour, 150mm wide cavity, A.O.V.:
including 100mm thick high density Kingspan "ThermaWall Stairway to have 1.5m smoke vent at ceiling
TW50" partial cavity fill insulation board or similar approved, level extracting smoke to outside air through
with 100mm thick solid blockwork fair-faced inner leaf. roof covering . ventilation to comply with bs
External wall cavities MUST be kept clear for between 5588-9:1999
150mm & 225mm below DPC level.
Internal Stairs:
Emergency Roof Roof Emergency Internal staircase to be of cast in-situ or precast
Internal Walls: Escape Light Light Escape concrete, with non-slip finish to threads, to
Internal walls to be unrendered, fair-faced blockwork, Rooflight Rooflight architect's approval, with toe inserts. Landings,
with pointed mortar joints, clear of snots, sealed & Storage & Committee Stairwell balusters, handrails, and step rise and going must
painted to selected colour. Internal ceilings to receive Meetings Room comply with the current Technical Guidance
3mm thick skim plaster finish on 12.5mm plasterboard, Document Part K for stairs.
painted to selected colour.
File: newport_TD_1_2.dwg
GENERAL:
1 ALL FINISHES AND FITTINGS TO BE AGREED WITH CLIENT.
C2
ALL STRUCTURAL TIMBERS TO COMPLY WITH SR 11 TABLES.
C1
Steel Post Legend: FOUNDATIONS
baseplate to foundation all to Engineer's details
THE FOUNDATIONS MUST HAVE AT LEAST A MINIMUM WIDTH
Painted SHS corner post, anchored via
C1
EQUAL TO THREE TIMES THE THICKNESS OF THE WALL IT IS
baseplate to foundation all to Engineer's details
Painted UB Column, anchored via baseplate SUPPORTING. THE MINIMUM DEPTH OF FOUNDATION EXCAVATION
2 2
C2
C2
C2
Painted steel beam to foundation all to Engineer's details THAT ALL BLOCKWORK WALLS ARE BUILT FROM A FOUNDATION.
Beam
to Engineer's details THE SPECIFICATIONS FOR THE ABOVE ARE BASED ON NORMAL
Painted steel beam GROUND CONDITIONS
Beam
to Engineer's details
GROUND FLOOR SLAB
USE GOOD QUALITY HARDCORE EG. CLEAN, WELL GRADED BROKEN
1 1 1 STONE, 100mm MAX SIZE. COMPACTED IN LAYERS NOT EXCEEDING
225mm IN DEPTH. & BLINDED WITH A 50mm COVERING OF SAND.
A DAMP PROOF MEMBEANE OF AT LEAST 1200 GAUGE MATERIAL TO
BE LAID, WITH JOINTS LAPPED AND SEALED. 100mm HIGH DENSITY
RIGID INSLUATION TO BE PLACED ON TOP OF DAMP PROOF
MEMBRANE WITH 25mm HIGH DENSITY INSULATION TO BE PLACED
ALONG EDGE OF FLOOR SLAB.
RADON PROTECTION
A SUMP MUST BE PROVIDED WITH CONNECTING PIPEWORK
TERMINATIONG AND CAPPED AT SUITABLE POINTS OUTSIDE THE
EXTERNAL WALLS OF THE DWELLING. IN SITUATIONS WHERE THE
RADON LEVEL IS UNACCEPTABLY HIGH, AN APPROVED RADON
BARRIER OF LOW PERMEABILITY SHOULD ALSO BE USED.
CAVITY WALLS
C2
C1
350mm deep, C28/35 cast in-situ concrete ROOF
strip footing, to a minimum depth of 900mm ADEQUATE TRIANGULATION OF THE ROOF SHOULD BE ACHIEVED
below Finished Ground Level with 12mm AT ALL TIMES. 100 x 75mm WALLPLATE TO BE FIXED TO TOP OF
diameter reinforcing mesh to base of footing SUPPORTING WALL WITH GALVANISED STRAPS AT 1.8m CENTRES.
with 50mm cover under and minimum ALL ROOF TIMBERS TO BE TREATED, WITH RAFTERS & CEILING
C1
600mm laps. External wall cavity MUST be JOISTS SET AT 400mm CENTRES. TIMBER PURLINS SHOULD BE
C1
C1
kept clear for between 150mm & 225mm PROPPED AT REGULAR INTERVALS. COLLARS TO BE PLACED AT
below DPC level. Width varies depending on 1600mm CENTRES. VENTILATION TO ROOF SPACE SHOULD BE
width of rising wall - Refer to Sections ACHIEVED BY PROVIDING THE EQUIVALANT OF 10mm CONTINUOUS
STRIP AT EAVES LEVEL.
C2
C2
C2
NEEDS TO PROVIDE A CLEAR OPENABLE AREA OF 0.33sq/m WHICH
SHOULD INCLUDE A MINIMUM WIDTH OR HEIGHT OF 450mm. THE
BOTTOM OF THE WINDOW OPENING MUST BE NOT MORE THAN
1100mm AND NOT LESS THAN 800mm (600mm IN THE CASE OF
ROOFLIGHTS) ABOVE FLOOR LEVEL. A MAINS OPERATED FIRE
DETECTION AND ALARM SYSTEM MUST BE PROVIDED. BATTERY
OPERATED SYSTEMS ARE NOT ACCEPTABLE.
DISABLED ACCESS
1780x780mm VELUX "INTEGRA" manually WHEELCAHIR ACCESS TO BE PROVIDED IN ACCORDANCE WITH
operated GGL306021U Pine framed rooflighst with PART M OF THE TECHNICAL GUIDANCE DOCUMENTS 2010.
A B --60 Pane glazing and BDX Insulation Collar. 2 Nr
indicated to serve as emergency escape windows
350mm wide external cavity wall. Slated roofs to be of Thrutone Blue Black slates,
Cavity MUST be kept clear for between by Tegral or similar approved, with dry-fixed
100mm wide internal solid block on edge wall 215mm wide internal solid block on flat wall
150mm & 225mm below DPC level. ridge & verges & permanent proprietary over
facia & ridge level ventilation throughout
150mm thick, mesh reinforced,
150mm thick, mesh reinforced, 150mm thick, mesh reinforced, cast in-situ concrete floor slab
cast in-situ concrete floor slab cast in-situ concrete floor slab
F.F.L. F.F.L. F.F.L.
F.G.L.
C C
350mm deep x 1050mm wide, c28/35 cast 350mm deep x 800mm wide, c28/35 350mm deep x 915mm wide, c28/35
in-situ concrete strip footing, to a minimum cast in-situ concrete strip footing, to a cast in-situ concrete strip footing, to
depth of 900mm below Finished Ground Level minimum depth of 900mm below a minimum depth of 900mm below A.O.V.:
with 12mm diameter reinforcing mesh to base Finished Ground Level with 12mm Finished Ground Level with 12mm Stairway to have 1.5m smoke vent at
of footing with 50mm cover under and diameter reinforcing mesh to base of diameter reinforcing mesh to base of ceiling level extracting smoke to outside air
minimum 600mm laps. External wall cavity footing with 50mm cover under and footing with 50mm cover under and through roof covering . ventilation to comply
MUST be kept clear for between 150mm & minimum 600mm laps. minimum 600mm laps. with bs 5588-9:1999
225mm below DPC level.
Typical 350mm Wide External Wall Typical 100mm Wide Internal Wall Typical 215mm Wide Internal Wall
A B
AJ
AJ AJ AJ
SVP
Beam
C2
BIGT
Boiler Showers WC Showers WC WC Showers WC Showers Boiler Showers WC Showers WC WC Showers WC Showers
Beam
LEGEND: AJ Storage Storage
Foul AJ & Sewer Line
AJ
Storm Water AJ & Storm Line
Changing Changing Changing Changing
C2
Storage Changing Changing Storage Storage Changing Changing Storage
Room 1 Room 2 Room 1 Room 2
New Precast Concrete ACO-Drain
ACO-Drain
Room 3 Room 4 Room 3 Room 4
LEGEND:
ACO-Drain
Aco-Drainage Channel
SVP AJ WC WC
Beam
Soil Vent Pipe
Solid Blockwork Walls
Back Inlet Gully Trap & Downpipe
BIGT
ACO-Drain
Steel Post Legend:
AJ Disabled Disabled Painted SHS corner post, anchored via
C1
WC WC baseplate to foundation all to Engineer's details
C2
Hallway Painted UB Column, anchored via baseplate
C2
to foundation all to Engineer's details
C1
1
Painted steel beam
Beam
Beam
Beam BeamC
Beam
Beam
Up Lintels between steel posts, Up to Engineer's details
supporting glazed screens, to be
of primed & painted structural Beam Beam
steel angle sections, or similar,
Beam
C1
For First Floor Level Structural
C1
Steel beams to
C1
to Engineers details
Covered Area Engineer's details Layout, Refer to First Floor
BIGT Entrance
Layout Plan on Drg T-03
Lobby Beam Beam Beam Beam Beam
C2
AJ AJ ACO-Drain
C2
C2
C2
C2
C2
A B
REF TYPE RATING LEAF OPE SIZE OPENING SWING HUNG
Vision
S1 Panelled
FD30s Single 2100x950mm Inward Right Hand Side
Vision
S2 Panelled
FD30s Single 2100x950mm Inward Left Hand Side
Vision
S3 Panelled
FD30s Single 2100x950mm Inward Right Hand Side
Vision
C C1 D S4 Panelled
FD30s Single 2100x950mm Inward Left Hand Side
Vision
S5 Panelled
FD30s Single 2100x950mm Inward Left Hand Side
ALL Internal Doors to be Solid Oak Veneered & Framed, FULL VENEER PANELLED, with
No Saddle, Pull & Push Handles, Kicker-Plates, Cubcle Locks, Hinges, Door Closers etc
E, F G, I
E1 G1,
G2
TYPE REF REF Nr. WIDTH (W) HEIGHT (H) DESCRIPTION NOTES
W13, W15, Double Top Hung Single Toughened FROSTED
A W18,W20
1866mm 600mm
Casement Glass
Double Top Hung Single Toughened FROSTED
A W6 1750mm 600mm
Casement Glass
W5, W7, W12, W14, W16, Single Top Hung Toughened FROSTED
B W17, W18, W19
600mm 600mm
Single Casement Glass
Double Fixed Panes c/w
Toughened CLEAR
C W3 2300mm 2100mm Colour-Matched, Insulated Cladding to
Glass
Internal Corner Post on RHS
Double Fixed Panes c/w
Toughened CLEAR
C1 W23 2300mm 2100mm Colour-Matched, Insulated Cladding
Glass
to Internal Corner Post on LHS
Triple Locking, Double Leaf, Toughened CLEAR Glass, Level
D W1, W27 1800mm 2100mm Outward Opening, Glass Access Threshold & Door
Panelled Main Entrance Doors Closers
Toughened CLEAR
E W2, W24 1350mm 2100mm Single Fixed Pane
Glass
Toughened CLEAR
E1 W28, W28 750mm 2100mm Single Fixed Pane
Glass
Colour to Client's Selection. All Frames to be UPVC Double Glazed Throughout. Toughened Glass to all
glazing below 800mm of FFL. MINIMUM CLEAR OPENING WIDTH TO EXTERNAL DOORS => 775MM
Project: Drawn By: K Coleman