Crosby Bolt Type Shackles: Testing The Limits

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Crosby® Bolt Type Shackles

• Capacities 2 to 17 metric tons.


• Meets or exceeds all requirements of Grade 8 shackles.
• Working Load Limit permanently shown on every shackle.
• Forged Alloy Steel – Quenched and Tempered, with bow and bolt.
• Hot Dip galvanized.

Shackles
• Shackles can be RFID EQUIPPED.
• Meets or exceeds all requirements of ASME B30.26 including identification,
ductility, design factor, proof load and temperature requirements.
Importantly, G-2130A meet other critical performance requirements
including impact properties and material traceability, not addressed by
G-2130A ASME B30.26.
Bolt Type Anchor shackles with thin
head bolt – nut with cotter pin. Meets • Shackles can be furnished proof tested with certificates to designated
the performance requirements of standards, such as ABS, DNV, Lloyds, or other certification when requested
Federal Specification RR-C-271F
Type IVA, Grade B, Class 3, except at time of order.
for those provisions required of the • Type Approval and certification in accordance with DNV 2.7-1 Offshore
contractor. For additional information,
see page 452. Containers.
• Shackles are Quenched and Tempered and meet DNV impact requirements
of 42 joules (31 ft.-Ibs.) at -40 degrees C (-40 degrees F).

®
SEE APPLICATION INFORMATION
On Page 92 of the General Catalog
Para Español: www.thecrosbygroup.com

G-2130A Alloy Bolt Bolt Type Shackles Grade 8


Working Dimensions Tolerance
Nominal Load Weight (in) +/-
Size Limit G-2130A Each
(in.) (t)* Stock No. (lbs.) A B C D E F H L M N C A
1/2 2 1219472 .79 .81 .63 1.88 0.50 1.31 1.19 3.29 2.30 2.80 0.50 0.13 0.06
5/8 3-1/4 1219491 1.37 1.06 .75 2.38 0.63 1.69 1.50 4.18 2.94 3.56 0.69 0.25 0.06
3/4 4-3/4 1219516 2.71 1.25 .88 2.82 0.75 2.01 1.81 4.96 3.51 4.15 0.81 0.25 0.06
7/8 6-1/2 1219534 3.95 1.44 1.00 3.31 0.88 2.29 2.09 5.83 4.02 4.82 0.97 0.25 0.06
1 8-1/2 1219552 5.03 1.69 1.10 3.76 1.00 2.70 2.38 6.58 4.69 5.39 1.06 0.25 0.06
1-1/8 9-1/2 1219578 8.27 1.81 1.25 4.26 1.13 2.92 2.70 7.49 5.16 5.90 1.25 0.25 0.06
1-1/4 12 1219598 11.7 2.03 1.38 4.69 1.25 3.25 2.99 8.27 5.75 6.69 1.38 0.25 0.06
1-3/8 13-1/2 1219614 15.8 2.25 1.50 5.24 1.38 3.62 3.31 9.18 6.38 7.21 1.50 0.25 0.13
1-1/2 17 1219632 19.0 2.38 1.63 5.75 1.50 3.88 3.62 10.0 6.90 7.73 1.62 0.25 0.13
* NOTE: Maximum Proof Load is 2.0 times the Working Load Limit. Minimum Ultimate Strength is 8 times the Working Load Limit. For Working Load Limit
reduction due to side loading applications, see page 94.

Testing the Limits


In 2013, Sir Ranulph Fiennes and five colleagues
set out to test the limits of human endurance and
achieve the feat of becoming the first individuals
to cross the continent of Antarctica in winter. As
a proud partner in this endeavor, Crosby provided
its full range of COLD TUFF® products, which
are specifically manufactured to function in
extreme environments such as those encountered
throughout the expedition—including temperatures
as low as -90° C.

Copyright © 2017 The Crosby Group LLC All Rights Reserved 81