INTECONT® PLUS For Measuring Systems: % Compact Weighing Electronics For
INTECONT® PLUS For Measuring Systems: % Compact Weighing Electronics For
INTECONT® PLUS For Measuring Systems: % Compact Weighing Electronics For
Application Equipment
The INTECONT® PLUS weighing The system is supplied as front panel % Galvanically isolated outputs
electronics is specially designed for mounting unit or with wall-mounting
% Totalizing counter pulses
weighing in continuous production housing for local installation. Operation
processes. It is the right solution is via ergonomically styled keyboard % Fail-safe data memory (EEPROM)
whenever material flows have to be organised into operating and service
functions. A luminescent, anti-glare % Integrated diagnostics and self-
measured and acquired with high
two-line display ensures easy reading testing functions (SPC)
accuracy with the use of
of results. % Default settings for simple and quick
% Belt weighers (MULTIBELT®) Equipped with appropriate commissioning
% Solids flow meters (MULTISTREAM®) communication module, INTECONT®
PLUS optimally fits into any automated % Auto calibration (automatic
% Coriolis mass flow meters environment. calibration programs, self-starting
taring)
(MULTICOR®)
Operating Principle % Calibration intervals with signal
This also covers special applications, output (selectable at will)
e.g. legal-for-trade weighing or use in Although the INTECONT® PLUS
the hazardous area. functions vary with every scale type, the % Dialog available in German, English,
The INTECONT® PLUS weighing basic equipment is always the same. Italian, Spanish and French
electronics is primarily designed for % System accuracy for weighing tasks % Status, event, calibration and
applications with a need for convenient better than 0.05% quantity reports
and elaborate display, control and
monitoring, in addition to basic measuring % Manual and/or automatic zero setting % Simulation mode for testing and
functions. The weighing electronics learning
% Full feed/dribble feed control for
ensures repeatability and transparency
accurate batching
of the production process.
% High electromagnetic compatibility
BV-D2184GB
Weighing functions Dimensions (mm)
As a function of mechanical system
used, the actual feed rate is acquired
INTECONT® PLUS for Front Panel Mounting
using:
% Belt load and belt speed
(belt weighers)
Panel cut-out
% Reactive force (solids flow 282 + 0,5 x 88 + 0,5
meters)
% Direct mass flow measurement
on the Coriolis principle (mass
flow meters)
In addition to the comprehensive
basic equipment, the following
weighing functions are available:
% Belt weighers
- Accurate belt speed
measurement
- Belt influence compensation
(BIC)
- Belt run monitoring
- Shifting of weighing to point
of discharge
- Legal-for-trade variant
(upon request)
% Solids Flow Meters
- Adaption to varying INTECONT® PLUS Wall Housing INTECONT® PLUS Wall Housing
measuring chute Belt Weighers, Solids Flow Meters Coriolis Mass Flow Meters
characteristics
% Coriolis Mass Flow Meters
- Accurate speed and torque
acquisition
Bottom View
Technical Data
I / 0 Expansion (Option)
BV-D2184GB 0903 All information is given without obligation. All specifications are subject to change. © by Schenck Process GmbH, 2009
Analog display
Event printer
Application
Designed for feeding duties in continuous The measuring, control, and supervisory % System accuracy for weighing tasks
processes, the INTECONT® PLUS electronics is specially economical if the better than 0.05%
measuring, control, and supervisory feed system is controlled locally in % Precise speed acquisition
electronics is specially suited for single normal mode or from the display and % Optimal feed control for accurate
feeders and small gangs controlled by a control panel in a central control room. batching via an adaptive control
host system. The system is the right circuit
choice whenever bulk solids have to be Equipment % High electromagnetic compatibility
fed with high accuracy with the use of % Galvanically isolated outputs
The electronics is supplied as front-of- % Fail-safe data memory (EEPROM)
% belt weighers (MULTIBELT® or panel mounting unit or with an optional % Integrated diagnostics and self-
weigh belts with controlled prefeeders wall-mounting housing for installation at testing
site. The system is operated via an % functions (SPC)
% weighfeeders (MULTIDOS®)
ergonomically styled keyboard organised % Preset with default values for easy
% Coriolis mass flow feeders into operating and service functions. A and quick commissioning
(MULTICOR®) luminescent, anti-glare two-line display
% AUTO calibration (automatic
ensures easy reading of results.
% loss-in-weight feeders (discharge and calibration programs), theoretical
Equipped with appropriate
fill weighing with MECHATRON® / communication module,
span calibration without auxiliaries
AccuRate) Totalising pulse (level and pulse
INTECONT® PLUS optimally fits into any %
without expensive control of the feeder automated environment. width set by parameter)
environment. The system can also be % Simulation mode for testing and
used in special applications, i.e. in the Operating Principle learning
hazardous area. % Status, event, calibration and
Although the INTECONT® PLUS quantity reports
functions vary with every scale type, the Dialog in German, English, Italian,
basic equipment is always the same. Spanish and French.
BV-D2185GB
Weighing Functions Dimensions (mm)
The difference of set and actual feed
rates, determined by comparison,
forms the control output to the feeder INTECONT® PLUS
control circuits. As a function of for Front-of-Panel Mounting
feeder type, a corresponding control
signal is transferred to the speed- Panel cut-out
controlled weigh belt, the controllable 282 + 0.5 x 88 + 0.5
discharge unit of the loss-in-weight
feeder or the controllable feed unit of
the Coriolis mass flow feeder.
The control circuit exactly controls
the actual feed rate for setpoint.
The actual feed rate is acquired
using:
% Measured variables, i.e. belt
speed and belt load with
weighfeeders
% Loss in weight in the hopper per
unit time with loss-in-weight
feeders
% Direct mass flow measurement
on the Coriolis principle (mass
flow feeders)
In addition to the comprehensive
basic equipment, the following
weighing functions are available:
% Weighfeeders
- Control for point of discharge
- Automatic belt run monitoring Wall-mounting
(belt slip, belt skew) Housing
X = 0 : No I/0 expansion Control cubicles or racks with/without power supply for max.
= 1 : With I/0 expansion 2 INTECONT® PLUS
Y = 0 : No communication module Wall-mounting housing with drive units up to 3 kW and
Y = 1 : Communication module Modbus, 3964 R power supply
Y = 2 : Communication module Profibus DP
Y = 3 : Communication module Device Net Power supply: desk-top, panel-mounting units
BV-D2185GB 0809.1 All information is given without obligation. All specifications are subject to change. © by Schenck Process GmbH, 2008
Y = 4 : Communication module Ethernet MODBUS/TCP
Y = 5 : Communication module Ethernet/IP Local control unit
Analog display
Event printer
DC isolator