1. GENERAL .............................................................................................................................. 9
1.1. Precautions............................................................................................................ 9
1.2. Introductions ....................................................................................................... 11
1.3. Specifications...................................................................................................... 12
1.4. Name and Functions .......................................................................................... 15
1.5. Basic Set - Up ..................................................................................................... 26
1.6. Symbols............................................................................................................... 23
1.7. Key Functions..................................................................................................... 28
1.8. Installation of the Label Roll............................................................................. 31
2. PROGRAMMING ............................................................................................................ 34
2.1. PLU Programming ............................................................................................ 40
2.1.1. Create By-Weight PLU (Menu code 1120) ................................................. 42
2.1.2. Create By-Count PLU (Menu code 1120) .................................................. 46
2.1.3. Create By-PCS PLU (Menu code 1120) ..................................................... 47
2.1.4. Editing PLU (Menu code 1120) ................................................................. 48
2.1.5. Management(Menu code 1140) ................................................................. 48
2.1.5.1. Copying PLU (Menu code 1141) ...................................................................... 48
2.1.5.2. Deleting PLU (Menu code 1142) ...................................................................... 49
2.1.5.3. Moving PLU (Menu code 1143) ....................................................................... 49
2.1.5.4. Selecting PLU field Items (Menu code 1144)................................................. 50
2.1.5.5. PLU Sale Count (Menu code 1145)..................................................................50
2.1.6. Listing PLU (Menu code 1150).................................................................. 51
2.1.7. Sample Printing (Menu code 1170) ............................................................ 51
2.2. Programming PLU Data Table I ...................................................................... 52
2.2.1. Department (Menu code 1210)................................................................... 52
2.2.1.1. New/Edit Department (Menu code 1211) .............................................. 53
2.2.1.2. List Department (Menu code 1212) ....................................................... 53
2.2.1.3. Delete Department (Menu code 1213). .................................................. 54
2.2.2. Group (Menu code 1220)........................................................................... 54
2.2.2.1. New/Edit Group (Menu code 1221) ...................................................... 54
2.2.2.2. List Group (Menu code 1222) ............................................................... 55
2.2.2.3. Delete Group (Menu code 1223) ........................................................... 55
2.2.3. Tax Rate (Menu code 1230) ....................................................................... 56
2.2.3.1. New/Edit Tax Rate (Menu code 1231)................................................... 56
2.2.3.2. List Tax Rate (Menu code 1232)............................................................ 57
2.2.3.3. Delete Tax Rate (Menu code 1233)........................................................ 57
2.2.4. Sales Message (Menu code 1240) .............................................................. 57
3
2.2.4.1. New/Edit Sales Message (Menu code 1241) .......................................... 58
2.2.4.2. List Sales Message (Menu code 1242)................................................... 58
2.2.4.3. Delete Sales Message (Menu code 1243) ............................................... 59
2.2.5. Origin (Menu code 1250) ........................................................................... 59
2.2.5.1. New/Edit Origin (Menu code 1251)....................................................... 59
2.2.5.2. List Origin (Menu code 1252)................................................................ 60
2.2.5.3. Delete Origin (Menu code 1253) ........................................................... 60
2.2.6. Barcode (Menu code 1260) ........................................................................ 60
2.2.6.1. New/Edit Barcode (Menu code 1261).................................................... 60
2.2.6.2. List Barcode (Menu code 1262)............................................................. 63
2.2.6.3. Delete Barcode (Menu code 1263)......................................................... 63
2.2.7. Tare (Menu code 1270) .............................................................................. 63
2.2.7.1. New/Edit Tare (Menu code 1271) .......................................................... 64
2.2.7.2. List Tare (Menu code 1272)................................................................... 65
2.2.7.3. Delete Tare (Menu code 1273)............................................................... 65
2.2.7.4. Tare Key (Menu code 1274) .................................................................. 66
2.2.8. Unit Symbol (Menu code 1280) ................................................................. 66
2.2.8.1. New/Edit Unit Symbol (Menu code 1281) ............................................. 66
2.2.8.2. List Unit Symbol (Menu code 1282)...................................................... 67
2.2.8.3. Delete Unit Symbol (Menu code 1283).................................................. 67
2.3. Programming PLU Data Table II ......................................................................68
2.3.1. Ingredient (Menu code 1310)...................................................................... 68
2.3.1.1. New/Edit Ingredient (Menu code 1311) ................................................. 68
2.3.1.2. List Ingredient (Menu code 1312) .......................................................... 69
2.3.1.3. Delete Ingredient (Menu code 1313)...................................................... 69
2.3.2. Nutrition Facts (Menu code 1320) .............................................................. 70
2.3.2.1. New/Edit Nutrition Facts (Menu code 1321) .......................................... 70
2.3.2.2 List Nutrition Facts (Menu code 1322).................................................... 74
2.3.2.3. Delete Nutrition Facts (Menu code 1323)............................................... 74
2.4. Discount Programming.......................................................................................75
2.4.1. Discount (Menu code 1130) ....................................................................... 75
2.4.1.1. New/Edit Discount (Menu code 1131)................................................... 75
2.4.1.2. List Discount (Menu code 1132)............................................................ 78
2.4.1.3. Delete Discount (Menu code 1133) ....................................................... 79
2.5. Gloabal Discount Program .................................................................................81
2.5.1. Global Discount (Menu code 1530) ............................................................ 81
2.5.1.1. Priority Setting (Menu code 1531) ......................................................... 81
2.5.1.2. Weight/Count/PCS Discount (Menu code 1532/1533/1534)................... 82
2.6. Speed Key Setting(Menu code 1160) ................................................................. 83
2.7. Traceability .............................................................................................................84
2.7.1. Traceability (Menu code 1330) ................................................................... 84
2.7.1.1. New/Edit Traceability (Menu code 1331)............................................... 84
4
2.7.1.2. List Traceability (Menu code 1332) ....................................................... 85
5
2.11.6.4. Scanner Config (Menu code 1464) .......................................................... 105
2.11.7. Label Format Key Table (Menu code 1470) ................................................ 106
2.12. Programming Global Setting ........................................................................107
2.12.1. Global Label Format (Menu code 1510) .................................................107
2.12.2. Barcode Format (Menu code 1520) ........................................................109
2.12.3. Tax (Menu code 1540) ......................................................................... 111
2.12.3.1. Set Global Tax (Menu code 1541) ................................................... 111
2.12.3.2. Global Tax Number (Menu code 1542) ............................................ 111
2.13. Printing Programming (Menu code 1700).................................................. 112
2.13.1. Print label item (Menu code 1710) .......................................................... 112
2.13.2. Markdown (Menu code 1720) ................................................................ 114
2.13.3. Printer Hardware (Menu code 1730)....................................................... 115
2.13.3.1. Print Mode (Menu code 1731)........................................................... 116
2.13.3.2. Label Size/Ticket Size (Menu code 1732) .......................................... 116
2.13.3.3. Sensor Calibration (Menu code 1733) ................................................ 116
2.13.3.4. Sensor & Motor (Menu code 1734) ................................................... 117
2.13.3.5. Print Intensity (Menu code 1735) ....................................................... 117
2.13.3.6. Adjust Feed Length (Menu code 1736) .............................................. 117
2.13.3.7. Label Preprint (Menu code 1737)....................................................... 118
2.13.4. Serial Number Format (Menu code 1740)............................................... 118
2.13.5. Add-Up Total (Menu code 1750) ............................................................ 119
2.13.6. Ticket (Menu code 1760)........................................................................120
2.13.6.1. Select Ticket Item (Menu code 1761).................................................120
2.13.6.2. Select List Item (Menu code 1762).....................................................121
2.13.6.3 Select Ticket Font Size (Menu code 1763) ..........................................122
2.14. Programming Scale Configuration (Menu code 1800) .............................123
2.14.1. Sale Mode (Menu code 1810).................................................................123
2.14.2. Operation Mode (Menu code 1820)........................................................125
2.14.3. Department (Menu code 1830) ...............................................................126
2.14.4. Date & Time (Menu code 1840) .............................................................126
2.14.5. User/ Security Configuration (Menu code 1850) .....................................127
2.14.5.1. New/Edit User(Menu code 1851) ......................................................127
2.14.5.2. Change Password (Menu code 1852) ................................................128
2.14.5.3. List User (Menu code 1853) ..............................................................129
2.14.5.4. Delete User (Menu code 1854) ..........................................................129
2.14.5.5. Config Permission (Menu code 1855)................................................129
2.14.5.6. Clerk Key ( Menu code 1856)............................................................132
2.14.6. Test (Menu code 1860) ...........................................................................132
2.14.6.1. Display Test (Menu code 1861)..........................................................133
2.14.6.2. A/D Test (Menu code 1862)...............................................................133
2.14.6.3. Keyboard Test (Menu code 1863) ......................................................133
2.14.6.4. Chess Printer Test (Menu code 1864) .................................................133
6
2.14.6.5. Printer Sensor Test (Menu code 1865)................................................ 134
7
3.7.2 % Unit Price Discount - By Weight PLU ...................................................170
3.7.3 Unit Price Discount - By PCS PLU ...........................................................172
3.8. Add-Up Transaction .........................................................................................173
3.9. Clerk Operation ................................................................................................175
3.9.1 Standard Clerk Operation ..........................................................................176
3.9.2 Floating Clerk Operations..........................................................................177
3.10. Void ..................................................................................................................179
3.11. Payment & Chance ........................................................................................180
3.12. Return ..............................................................................................................182
3.13. Prepack Key....................................................................................................183
3.14. X Key...............................................................................................................185
3.14.1 By-Weight PLU ......................................................................................185
3.14.2 Non-Weighed PLU .................................................................................186
3.15. How to Change Sell By Date/Time .............................................................187
3.16. How to Change Origin ..................................................................................188
3.17. How to Change PLU Type............................................................................189
3.18. Direct Discount...............................................................................................190
3.18.1. Fixed Price Key......................................................................................190
3.18.2. % Discount Price Key ............................................................................191
3.19. PLU Connection.............................................................................................192
3.19.1. Referenced PLU Function ......................................................................192
3.19.2. Coupled PLU Function...........................................................................192
3.19.3. Link PLU Function ................................................................................192
3.20. Sales Operation Control Parameters ............................................................192
3.20.1. Fixed Weight..........................................................................................192
3.20.2. Prepack Without Report..........................................................................192
APPENDIX ..............................................................................................................................193
1. Label Format ........................................................................................................193
1.1. Fixed Label Format Sample..........................................................................194
1.2. Label Format’s field Sample .........................................................................201
2. ASCII Code Table................................................................................................202
3. Window Character Set Information ..................................................................203
8
1.GENERAL
1.1 PRECAUTIONS
9
• CE Mark Warning
This is a Class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate measures.
10
1.2 INTRODUCTIONS
Thank you for purchasing the CAS CL5000 series price computing electronic printing
scale. We have designed this equipment with many advanced features, high quality
construction, and user-friendly menu driven programming. We are confident that you
will find the CAS CL5000 series scale will meet all of your most demanding needs.
Remember, for proper installation and maintenance please have your Authorized CAS
Dealer do the primary installation, programming, and demonstration. Your CAS
Authorized Dealer also has a wide variety of supplies, accessories, and expansion
options for whatever your new and increasing demands may require. Authorized CAS
dealers are trained to help you with every aspect of the CL5000 series and should you
need servicing, they are expertly trained by CAS to assist you with virtually
any problem.
11
1.3 SPECIFICATIONS
12
Printer Speed 100 mm/sec.
Printing Resolution 202 dpi
Width: 40mm~60 mm
Label Size
Length: 30mm~120 mm
13
Number Range
PLU
(Price Look Up, 3000 1~99999
Item Index Number)
Ingredient 510 character 999 1~999
User Defined Barcode Format 99 1~99
Department 99 1~99
Tax Type 9 1~9
Group 99 1~99
Clerk 95 1~95
Discount 99 1~99
Origin 499 1~499
Traceability 99 1~99
Slaughter House 99 1~99
Programmable Data Cutting Hall 99 1~99
Traceability Country 99 1~99
45 Fixed
Label Format
20 Free Format
Bitmap Image 14 1~99
Customer 99 1~99
Quanty symbol 8 1~8
Scroll Message 9 1~9
X1,X2,Z1,Z2 Report
Pay Type 9
Sales Message 99 1~99
Nutrifact 99 1~99
Tare Table 99 1~99
Sales Period Dual totals for daily/monthly or user selectable reporting period.
Sales Report Mode Read : X1/X2 Mode, Read & Reset: Z1/Z2 Mode
14
1.4 NAME AND FUNCTIONS
OVERALL VIEW
15
16
17
18
CL7200
19
OVERALL VIEW
TYPE-I : 5/8/9
TYPE-II : 4/5/6/6
■ CL5000
■ CL5500
TYPE-III : CL5000-G
TYPE-Ⅳ : CL5500-D
20
TYPE-Ⅴ :
■ CL5200-P
■ CL5200-B
21
KEYBOARD
Pole type
Standard
22
H-Type (hanging type)
23
D-Type (Double body type)
24
CL5200-B(Standard)
25
CL7200 Sale mode(Operator View)
26
CL7200 Input Mode
27
1.5 Basic set - up
28
D-type
PUSH
1.6 SYMBOLS
SYMBOLS DESCRIPTION
B, P, R, H
G - TYPE D - TYPE CL7200
- TYPE
ST ST STABLE ST Stable weight indicator
▶0◀ ZR ▶0◀ ▶0◀ Zero weight indicator
NET NET NET NET Net weight indicator
AUTO AT AUTO Print Mode indicator
SAVE SV SAVE SAVE Auto clearing status indicator
PREPACK PRK PREPACK PACK Auto clearing status and Print mode indicator
D/C DC D/C DISC Discount status indicator
SHIFT SH SH SHIFT Speed key shift status indicator
TR TR NET Data transmission status indicator
M Master status indicator
S Slave status indicator
LAN / WLAN LAN type indicator (Wired or Wireless)
KEY Editing speed key mode indicator
29
SERVER Connection status indicator
LN Ethernet Link Status indicator
30
1.7 KEY FUNCTIONS
KEY DESCRIPTION
Date & Time key. Toggles the display between time, date, scale
number and department number.
Up arrow key: Used to go to previous line in program mode.
MENU key. This key toggles from program menu to sale mode.
Page up key: Used to go to previous page in program mode.
For key. Use this key for by- count or by pcs pricing: 3 @ 3 FOR
$1.00. It toggles between the QTY, PIECE, and PRICE fields.
When you type a PLU number and press this key, it calls-up that PLU.
Down arrow key: Used to go to next line in program mode.
31
KEY DESCRIPTION
ADD-Up key. This key when used in conjunction with ST/TTL key allows
you print a customer-total label as well as individual transaction labels.
Page down key: Used to go to next page in program mode.
Multi-Label key. Use this key to print multiple sales of the same
transaction. Escape key. It is used to exit in program mode.
Subtotal / Total key. Used with the ADD key in order to print customer
totals.
Feed key. Use this key to feed labels or paper through printer
32
KEY DESCRIPTION
Used to type $
Space bar.
Note: X key is only used in sale mode and ESC key is only used in program mode.
33
1.8 Installation of the Label Roll
• Label Specifications
Outer diameter of roll : 100mm
Inner diameter of roll : 40mm
Width of receipt roll : 40, 50, 60mm
Width of label roll : 60mm(MAX)
• Print Area
Width of label : 60mm(MAX)
Printable width : 56mm(MAX)
Length of label : 120mm(MAX)
34
To install the label roll at ANY time you must follow the directions
in this section:
⑨ Press the FEED key. Scale prints twice for auto Label adjustment
35
Double Body Type (D-Type)
36
2. PROGRAMMING
Program Mode Menu Tree (Menu code : 1000)
37
1272 List Tare
1273 Delete Tare
38
CODE Menu CODE Sub Menu CODE Sub Menu
1281 New/Edit Unit Symbol
PLU Data Unit
1200 1280 1282 List Unit Symbol
Table I Symbol
1283 Delete Unit Symbol
1311 New/Edit Ingredient
1310 Ingredient 1312 List Ingredient
1313 Delete Ingredient
PLU Data 1320 Nutrition Facts
1300
Table II 1330 Traceability
1340 Country
1350 Slaughter House
1360 Cutting Hall
1411 New/Edit Store
1410 Store 1412 List Store
1413 Delete Store
1420 Customer
PLU Data
1400 1430 Scroll Message
Table III
1440 Currency
1450 Job Batch Schedule
1460 Scanner
1470 Label Format Key Table
1510 Label Format
1520 Barcode
1531 Priority Setting
Global 1532 Weight Discount
1500 1530 Discount
Setting 1533 Count Discount
1534 PCS Discount
1541 Set Global Tax
1540 Tax
1542 Global Tax Number
1611 Scale
1612 PLU
1613 Misc. PLU
1610 X1 Report 1614 Group
1615 Department
1616 Hourly
1617 Clerk
1600 Report 1620 Z1 Report
1631 Scale
1632 PLU
1633 Misc. PLU
1630 X2 Report 1634 Group
1635 Department
1636 Hourly
1637 Clerk
39
CODE Menu CODE Sub Menu CODE Sub Menu
1640 Z2 Report
1600 Report 1650 Clear All
1660 Non-sending Report
Print Label
1710
Item
1720 Markdown
1731 Print Mode
1732 Label/Ticket Size
1733 Sensor Calibration
Print
1730 1734 Sensor & Motor
Hardware
1700 Print 1735 Print Intensity
1736 Adjust Feed Length
1737 Label Preprint
1740 Serial Number Format
1750 Add-Up Total
1761 Select Ticket Item
1760 Ticket 1762 Select List Item
1763 Select Ticket Font Size
1810 Sale Mode
1820 Operation Mode
1830 Department & Store ID
1840 Date/Time
1851 New/Edit User
User/ 1852 Change Password
Security 1853 List User
1850
Configurati 1854 Delete User
on 1855 Config Permission
1856 Clerk Key
1861 Display
Scale 1862 A/D
1800
Config 1863 Keyboard
1864 Chess Printer
1860 Test
1865 Printer Sensor
1866 Memory Information
1867 Firmware Version
1868 Communication
1871 Display
1872 Printing
Scale
1870 1873 Sale setup
Parameter
1874 Clerk Logout
1875 System Restore
1880 Function Key Define
40
CODE Menu CODE Sub Menu CODE Sub Menu
1911 Service Type
1912 DHCP
1913 IP
Network
1910 1914 Remote IP
Setting
1915 RS232C
Communi 1916 WLAN setting
1900
cation 1917 WLAN Config
1920 Application
1930 Scale Lock/Unlock
1940 Check Scale
1950 Backup to Scale
1960 Slave Scale
You can see the Program Menu screen by pressing the MENU key.
The 2 numbers at top right (1/3) indicate the number of pages or screens. The
number to the left of the slash is the current page or screen number and the number to
the right of the slash indicates the total number of pages or screens. You can use the
PG UP and PG DOWN keys to navigate from page to page, or you can use the Arrow
keys to go through each page.
If you press “PG DOWN” key, you can see other menu screens as below.
41
The Screen capture of CL5000-G is as seen bellow
42
The Screen capture of CL5200 is as seen bellow
Screen Page
43
2.1 PLU Programming
You can set 47 items for a PLU as below table and if you do not want to use
some items, you can prohibit those items in menu code:1144.
No Item Description
1 Department Department No.
2 PLU No PLU No.
3 PLU Type Select PLU type among By Weight, By Count or By-PCS
4 Name Enter name 1 of item. Maximum 40 characters.
5 Name 2 Enter name 2 of item. Maximum 40 characters.
6 Name 3 Enter name 3 of item. Maximum 40 characters.
7 Group No. Select group number. This value can be from 0 to 99.
13 digits of EAN-13 barcode is used to output them
8 Ext.Barcode
as they are
(0~99) (0=Do not use Label No.), Label Formats “1~30”.
9 Label No.
If Global Setting is YES, it is not shown.
(0~99) (0=Do not use Label No.), Label Formats “1~30”.
10 Aux. Label No. This function prints aux. label as saved number of label
number
11 Origin No. (0~500) 0=Do not use origin.
15 Use Fixed Price Type You can set whether use Fixed Price or not
16 ☆Pieces (0-999) Set the number for By-PCS PLU
17 ☆Quantity Unit No. (0~8) Set symbol of PCS or Count
18 (Unit) Price This value can be from 0 to 999999.
19 Special Price It can be unit price by using Special key.
20 Tax No. Enter tax number. This value can be from 0 to9
You can enter tare weight manually or enter No. of tare
21 *Tare / Tare No.
data. (By-weight PLU)
44
No Item Description
0~99.99 You can enter tare weight as percentage of item. If
22 *% Tare
you set it to 20%, 20% of item is tare weight.
0~99.99 You can enter tare limit.
23 *Tare % Limit %tare < = % limit -> Gross weight is printed
%tare > % limit -> Net weight is printed
This value can be from 0 to 99, If Global Setting is YES, it is
24 Barcode No.
not shown.
45
No Item Description
43 ★Link PLU1 Dept. (0~99) Enter PLU1 department No.
* These items are shown on the display when you select By Weight PLU.
☆These items are shown on the display when you select By Count or By PCS PLU.
★These items are shown on the display when you input # of Link PLU.
◆ You can press the SAVE key at anytime to save the current PLU data and
if you want to exit without saving, press the ESC key.
Note: You may experience different item menus. You can modify menu items at menu (1144)
1. By Weight
2. By Count
3. By PCS
46
3. Enter PLU Name 1
EX) “BEEF”
4. Select Group
• You can use Group depending on the
Menu code 1220.
• If there is no group for this PLU, enter 0.
EX) 1. Meat
5. Select Origin
• You can use Origin depending on the
Menu code 1250.
• If there is no origin for this PLU, enter 0.
6. Enter Prefix
• If you do not want to use prefix, enter 0.
7. Item Code
• If you do not want to use item code, enter 0.
8. Price
47
9. Tax No.
• Maybe changed using Menu Code 1231.
If the Global Tax Settings (Menu Code 1541) is
not used.
• If you do not want to use, enter 0.
10. Tare
• You can use Tare Table, depending on the
setting of Parameter 584
You can set Tare Table(Menu code 1270)
EX) 0 : No print
1 : Print Date – 1 day
2 : Print Date – 2 days
EX) 0 : Today
1 : Today + 1 day
2 : Today + 2 days
EX) 1 : Today
2 : Packed date + 1
48
15. Sell By Time
49
2.1.2 Create By-Count PLU (Menu code 1120)
( MENU → 1. PLU → 2. New/Edit )
EX) PEAR
5. Price
50
2.1.3 Create By-PCS PLU (Menu code 1120)
EX) CAKE
4. Pieces
• If you enter 0 , it is regarded as 1.
EX) 10 piece
51
2.1.4 Editing PLU (Menu code 1120)
( MENU → 1. PLU → 2. New/Edit )
1. Select Source
• Enter the Department No. and PLU No.
that you wish to copy
2. Select Destination
• Enter the Department number where the
New PLU(s) will be located
• Enter the PLU number that you wish to
copy the Source PLU into
52
2.1.5.2 Deleting PLU (Menu code 1142)
• If There are three ways to delete PLU. Simply enter the number that you wish to delete.
• All the PLU information will move with commend (discount, Tax, barcode type, etc)
1. Select Source
• Enter the Department No. and PLU No.
which you wish to move
2. Select Destination
• Enter the Department number where the
PLU(s) will be located
• Enter the PLU number that you wish to
move the Source PLU into
53
2.1.5.4 Selecting PLU field Items (Menu code 1144)
( MENU → 1. PLU→ 4. Management → 4. Select PLU items
• If you enter N, you cannot use that item when you create PLU.
Note: You can use the PG UP and PG DOWN keys to navigate from page to page,
or you can use the Arrow keys to go through each page 1 line at a time.
A list of all available PLU Field Items can be found at the beginning of Section 2.1.
You can count each PLU sale and also you can clear this count.
54
2.1.6 Listing PLU (Menu code 1150)
EX) If set to Yes, when editing an existing PLU or creating a new one, depressing
the SAVE key will result in a label being printed with that PLU's information on it.
55
2.2 Programming PLU Data Table I
In the CL5000 series, PLU's are organized by Departments and sometimes Groups as
shown in the figure below. It is important to understand this structure to take advantage
of the CL5000 series sophisticated features regarding Label formats, X and Z reports,
etc.
Note: Groups can cross-over the hierarchy of the department structure. You can
organize PLU's by manufacturer, sales promotions, price range, etc.
Note: The CL5000 series has a sophisticated discount price programming function.
The discount price function can be programmed in great detail. Programming may be
done very easily using the PC software program CL-Works.
The CL5000 series can be programmed to have up to 99 different departments with like
PLU numbers in each department. The Scale ID setting (Menu 1830) determines which
PLU's an operator will be able to access on that scale. The operator will only be able to
call up PLU's assigned to the Department Number programmed in the Scale ID setting.
The Department number can be changed to access the different departments
programmed in the scale. Each Department also has a specific Speed Key Set assigned
to it in Menu 1830.
56
2.2.1.1 New/Edit Department (Menu code 1211)
◆ You can press the SAVE key at anytime to save the current data and if
you want to exit without saving, press the ESC key.
1. Department Number
• Department number is available 1 to 99.
2. Department Description
EX) Department 1 to 10
57
2.2.1.3 Delete Department (Menu code 1213)
( MENU → 2. PLU Data Table I → 1. Department → 3. Delete )
The Group menu is used to allow PLU's to be grouped regardless of their Department
assignments. A PLU must be assigned to a Department but does not have to be
assigned to a Group. The User may assign PLU's to a Group for the purpose of tracking
sales promotions, manufacturer's information, price ranges, etc.
You Can press the SAVE key at anytime to save the current data and if you want to
exit without saving, press the ESC Key.
EX) Group No = 1
58
2.2.2.2 List Group (Menu code 1222)
59
2.2.3 Tax Rate (Menu code 1230)
( MENU → 2. PLU Data Table I → 3. TAXRate )
Note: Tax Rate programming requires that a Level 3 Password be entered. See Section
2.14.6 User/Security Configuration.
4. Exit Menu
• If you want to exit, press ESC key.
60
2.2.3.2 List Tax Rate (Menu code 1232)
EX) 1~9
Sales message can be printed on PLU labels so long as the format that you
use contains a Sales Message field. This is a great tool for advertising and
cross-marketing products.
61
2.2.4.1 New/Edit Sales Message (Menu code 1241)
( MENU → 2. PLU Data Table I → 4. Sales Message → 1. New/Edit )
You can press the SAVE key at anytime to save the current data and if
you want to exit without saving, press the ESC key.
2. Enter Message
EX) Message = THANK YOU
3. Exit Menu
• If you want to exit, press ESC key.
EX) 1~10
62
2.2.4.3 Delete Sales Message (Menu code 1243)
To print the Country of Origin on a Label, the Label Format being used must contain
an Origin Field. You can also print the Country of Origin in one of the Commodity
Name Lines by using Menu Code 1872. Again, your Label Format must have an area
available to print the Origin.
※ You can press the SAVE key at anytime to save the current data and
if you want to exit without saving, press the ESC key.
2. Enter Origin
3. Exit Menu
• If you want to exit, press ESC key.
63
2.2.5.2 List Origin (Menu code 1252)
( MENU → 2. PLU Data Table I → 5. Origin → 2. List )
Up to 99 different Bar Code Formats can be programmed in the CL5000 series. Different
BarCode Formats can be assigned to individual PLU's or one Bar Code Format can be
used for all PLU's by enabling the Global Barcode Format Setting (Menu 1520).
EX) Barcode No = 1
64
2. Barcode Description.
3. Barcode Type
• Reference following table.
▶ type of Barcode
65
▶ The following defines the format characters for Barcode Formats : Example EAN13 )
▶ The following defines the format characters for Barcode Formats: (Example)
*% : It is used to enter characters therefore you can ‘t use this to enter numbers.
5. Exit Menu
• If you want to exit, press ESC key.
66
2.2.6.2 List Barcode (Menu code 1262)
( MENU → 2. PLU Data Table I → 6. Barcode → 1. List )
The CL5000 series can be programmed to use a Tare No. instead of a numeric
value.(System Parameter 584) If you are using Tare Numbers they should be
programmed prior to programming any PLU's that use a Tare weight.
Note: Tare weights for use in Tare No.'s can be programmed using the known numeric
67
value or by placing the actual container on the scale.
2. Tare Description
3. Tare Type
• There are 2 types of Tare Weights that can
be entered.
▶ Type of Tare
68
4. Enter Tare Value
5. Exit Menu
• If you want to exit, press ESC key.
69
deleting a Tare No. Pressing the PRINT key
will cause the Tare No. entered to be deleted.
This menu allows you to assign the Tare No.'s (Menu 1271) to Tare Keys. Tare Keys
must be programmed using Menu 1880 Function Key Define. There is a maximum of 9
Tare Function Keys available.
Note: When Special Function Keys are programmed they take the place of PLU
Speed Keys, reducing the number of Speed Keys accordingly.
EX) Tare No = 1
This menu allows you to program or change the Unit Symbol that will print on the
label for Non Weight or By Count PLU’s.
You can press the SAVE key at anytime to save the current data and if
70
you want to exit without saving, press the ESC key.
3. Exit menu
• If you want to exit, press ESC key.
71
Note: There is no confirmation request when
deleting a Unit Symbol No. Pressing the
PRINT key will cause the Unit Symbol No.
entered to be deleted.
72
2.3 Programming PLU Data Table II
◆ You can press the SAVE key at anytime to save the current data and if
you want to exit without saving, press the ESC key.
2. Enter ingredient
EX) Ingredient Line1 = SALT
EX) To print “SUGAR” on next line, enter
“ ” after SALT.
3. Exit menu
• If you want to exit, press ESC key.
73
2.3.1.2 List Ingredient (Menu code 1312)
( MENU → 3. PLU Data Table II → 1. Ingredient → 2. List )
74
2.3.2 Nutrition Facts (Menu code 1320)
Using this menu you can program Nutrition Facts information that can be linked to
individual PLU’s.
Note: The printing size of the Nutrition Facts may vary depending on the label format
selected.
◆ You can press the SAVE key at anytime to save the current data and if
you want to exit without saving, press the ESC key.
◆ You can use the PG UP and PG DOWN keys to navigate from page to page,
or you can use the Arrow keys to go through each page 1 line at a time.
75
1. Nutrition Fact No
• This value can be from 1 to 500.
2. Enter description
5. Calories
76
6. Calories from fat
7. Total Fat(g)
8. Saturated fat(g)
9. Trans Fat(g)
10. Cholesterol(mg)
EX) Cholesterol = 40 mg
11. Sodium(mg)
77
13. Dietary Fibers(g)
14. Sugars(g)
EX) Sugars = 3 g
15. Protein(g)
EX) Protein = 11 g
17. Calcium(%)
EX) Calcium = 2%
EX) Vitamin C = 0 %
78
19. Iron(%)
EX) Iron = 6 %
79
2.4 Discount Programming
◆ You can use the PG UP and PG DOWN keys to navigate from page to page,
or you can use the Arrow keys to go through each page 1 line at a time.
80
▶ Discount Type
# Type Description
9 % Total Price by Total Price - Set a discount % of total price for current total price
11 Extra by Total Price - Set a discount number of item for current total price
※ Please refer to “Parameter” when user wants to also see the unit price discounted
on “Unit Price” segment together with total price discounted in display
81
3. Enter discount value
• Refer to below table.
4. Discount Condition 1:
(Set the day of week )
1 -> Discount
0 -> Do not discount
EX) Discount on Thursday, Friday and
Saturday
82
5. Discount Condition 2
(Set date and time)
6. Exit menu
• If you want to exit, press the ESC key.
EX) Department No 1.
83
on the screen, pressing the TEST key will
print the Discount type of PLU No.'s.
◆ There are three ways to delete Discount. Simply enter the number that
you wish to delete.
84
2) Delete by Dept. No. (DC) (Menu code 1138)
85
2.5 Global Discount Programming
This menu is used to select what type of Discount is applied to a PLU. You can
select to use a Global Discount for all PLU's, apply Discounts based on individual
PLU's or use no Discount at all. Refer to the chart below for all options.
This menu is used to determine which Discount will have priority. Refer to the chart
below.
Note: Discount information can be seen on the display using Menu code 1871.
(See chapter 2.14.7) Discount information is also printed on the label.
No Type Description
0 No Discount No discount applied
1 PLU Discount PLU discount only applied
2 Global Discount Global discount only applied
86
2.5.1.2 Weight/Count/PCS Discount (Menu code 1532/1533/1534)
If you want to use the Global Discount method and apply the same discount
regardless of PLU, you can set the Discount information in Menu code 1532, 1533
and 1534. You can use the same procedures shown in chapter 2.4.2.
87
2.6 Speed Key Setting (Menu code 1160)
( MENU → 1. PLU → 6. Speed Key )
This menu is used to program Speed keys. Speed keys are short-cut keys used to allow
quick access to the most frequently used PLU's in a department. There is also a SHIFT
function that allows you to set a second level of Speed keys that will double the number
of Speed keys available in a department.
You can program up to 5 different Speed Key Sets but only one set can be used in a
department at a time. The Speed Key Set that is used in a department is determined by
Menu code 1211 (chapter 2.2.1.1)
Note: Function keys can be programmed using Menu code 1880 (chapter 2.14.8) and
are assigned to Speed Key locations. If you program Function keys on the CL5000
series you will decrease the total number of Speed Keys available.
3. PLU No.
• Enter PLU no. to assign speed key
• PLU should be belong to scale department.
88
2.7 Traceability
This Menu is used to program the history of a PLU. You must follow local Traceability
regulations when using this menu.
Note: You should program the Country Code (Menu 1340), Slaughter House
(Menu 1350) and Cutting Hall (Menu 1360) before programming the Traceability.
▶You can press the SAVE key at anytime to save the current data and if
you want to exit without saving, press the ESC key.
2. Enter description
89
4. Bred in country number
7. Exit menu
90
2.7.1.3 Delete Traceability (Menu code 1333)
( MENU → 3. PLU Date Table II → 3. Traceability→ 3. Delete )
91
2.8 Country Programming
2.8.1 Country (Menu code 1340)
( MENU → 3. PLU Date Table II → 4. Country )
▶You can press the SAVE key at anytime to save the current data and if
you want to exit without saving, press the ESC key.
3. Exit menu
• If you want to exit, press ESC key.
92
2.8.1.2 List Country (Menu code 1342)
( MENU → 3. PLU Date Table II → 4. Country → 2. List )
93
2.9 Programming Slaughter House
2.9.1 Slaughter House (Menu code 1350)
( MENU → 3. PLU Date Table II → 5. Slaughter House )
▶You can press the SAVE key at anytime to save the current data and if
you want to exit without saving, press the ESC key.
4. Exit menu
• If you want to exit without making any
changes, press ESC key.
94
2.9.1.2 List Slaughter House (Menu code 1352)
( MENU → 3. PLU Date Table II → 5. Slaughter House → 2. List )
95
2.10 Programming Cutting Hall
2.10.1 Cutting Hall (Menu code 1360)
( MENU → 3. PLU Date Table II → 6. Cutting Hall )
This menu is used to program Cutting Hall information. Cutting Hall information is
used when programming Traceability Numbers. Therefore Cutting Hall information
programming should be completed prior to programming Traceability.(Menu 1330)
▶You can press the SAVE key at anytime to save the current data and if
you want to exit without saving, press the ESC key.
4. Exit menu
• If you want to exit, press ESC key.
96
2.10.1.2. List Cutting Hall (Menu code 1362)
(MENU → 3. PLU Date Table II → 6. Cutting Hall → 2. List )
97
2.11 Programming Store Data
This chapter explains how to access and program Store Data, Customer Information,
Scrolling Messages and Currency Data.
EX) #1
EX) TEL.#=2019339002,
TEXT=NJ CAS office
98
2.11.1.2 List Store (Menu code 1412)
1. Store delete
EX) Store. 1
99
2.11.2 Customer (Menu code 1420)
( MENU → 4. Store Data Table → 2. Customer )
EX) NAME=TOM
ADDRESS 1=99 Murry hill.
ADDRESS 2=East ford
100
2.11.2.2 List Customer (Menu code 1422)
This Menu allows you to list the Customer No.'s on the screen or print them out for
your records.
101
2.11.3 Scroll Message (Menu code 1430)
( MENU → 4. Store Data Table → 3. Scroll Message )
This Menu is used to program the Scrolling Message function in the CL5000 series.
The Scrolling Message can be used for advertisements, sales promotions, sales
messages, etc.
The configuration function allows you to program the wait time and the actual
scrolling speed of the message.
1. Configuration
• User may set the wait time from 1 to 6000
seconds. Setting wait-time as 0 means NO
use “Scroll Message”.
- Wait-time
This value can be from 1 to 6000 seconds.
Ex.) 5 seconds
This Menu allows you to program the actual information that will be in the Scrolling
Message. You may input up to 9 messages and use two different scrolling effects.
102
4. Set Speed
• Speed means the scrolling/blinking
speed.=> for the text speed is representing the moving speed of the text, and when it is
blinking speed, it represents the speed of the blinking. User may set it from 1 to 99..
(unit = 0.1m/s)
• Enter Date
Ex.) Start Date = 00-00-00
End Date = 00:00:00
Note: If you enter 00-00-00 for a Start and
End Date. This means that the message will
be shown starting today and will be shown
everyday until December 31, 2099.
• Enter Time
Ex.)Start Time = 00:00:00
End Time = 00:00:00
Note: Start time should be lower than the End time. If 00:00:00 is entered for both
times then the message will be displayed for the entire day.
103
2.11.3.3 List Scroll Message (Menu Code 1433)
( MENU → 4. Store Data Table → 3. Scroll Message → 3. List )
1. Numbering Currency
• You can save up to 4 different currencies
by numbering 1~4.
104
3. Currency Rate.
• Enter comparative rate of currency to
default currency set.
EX) Default currency = $1.00
Comparative currency rate to default
Currency
= ¤ 1.2800.
4. Primary Sign
• Enter the first currency sign to be
changed.
5. Last Symbol
• Enter the last currency symbol to be
changed.
105
7 $100.00c, $0.12c
When total amount is less than 1, only
8 $100.00c, 12c(Greek)
Last currency symbol shows up.
106
2.11.4.2 List Currency (Menu Code 1442)
107
2.11.5 Job Batch Schedule (Menu code 1450)
( MENU → 4. Store Data Table → 5. Job Batch Schedule )
This function is used to print the label in large number for the pieced products or to
sell several pieced products that have been packaged into a set.
.
2. Department No.
• Enter the umber of Department to call.
3. PLU No.
• Enter the number of PLU to call.
108
2.11.5.2 List Job Batch Schedule (Menu code 1452)
This menu is used to make barcode scanning sale available or just to call up PLU.
These are operable functions and setting methods when using by connecting the barcode scanner to
CL5000 series.
This is Mapping Table between each scanned bar code and each PLU number.
109
3. Setting up department No
Enter the Department number of the PLU to be mapped.
4. Setting up PLU No
Enter the PLU number to be mapped.
EX)
The value to be compared with Department and PLU no. to be
Index
data from a bar code mapped
Code No Mapping Code Department No PLU No
1 2855551 1 1
2 2855552 1 5
~ ~ ~ ~
110
2.11.6.4 Scanner Config (Menu code 1464)
-“X” character : It must be the number of same digit length as “Mapping Code”, that you entered
above, has.
-“W” character : It represents weight date.
111
2.11.7 Label Format Key Table (Menu code 1470)
( MENU → 4. Store Data Table → 7. Label Format Key Table )
There is a function to change label format and Barcode by using function key. This menu is used to
set this function. You can use this function, after assigning empty key to that Function
Key(83-90).
2. Label #.
112
2.12 Programming Global Setting
The Global Setting function is used to program functions of the CL5000 series like Label
Format, Barcode Format, Discount and Tax settings that will be used on every PLU or
transaction. These settings, when selected override any settings that are programmed
in the PLU. This function can be very convenient and time saving when used properly.
This Menu is used to select whether you use a Global Label Format for all PLU's or if
the Label Format will be programmed in the PLU data structure.
Note: Label Formats 1~45 are Fixed Label Formats and can not be modified. Formats
51~99 are Free Formats that may be created using the CL-Works PC Program and
downloaded to the CL5000 series.
◆ You can press the SAVE key at anytime to save the current data and if
you want to exit without saving, press the ESC key.
1. Global Label
• If you use Global Label, enter 1. If not,
enter 0.
113
4. Set total label number
• Set label format of total label for Add-Up
sales.
7. Input Label #2
If you do not wish to use the label #2, simply input ‘0’. It operates in the same manner as the
Aux.Label of the PLU input items. If the Aux.Label No. of PLU has already been registered,
print with the corresponding label number, and if not, output the inputted Label #2
8. Exit menu
• If you want to exit, press ESC key.
114
2.12.2 Barcode Format (Menu code 1520)
◆ You can press the SAVE key at anytime to save the current data and if
you want to exit without saving, press the ESC key.
115
6. Set barcode number for Misc. weight
item
116
12. Exit menu
• If you want to exit, press ESC key.
It sets up the kind of tax to apply to Misc by Weight, Misc by count, Misc by PCS.
- 0 : Do not Use Misc tax
- 1 ~ 9 : Select registered tax
(Selection among tax at registered menu 1230, 9 options)
117
2.13 Printing Programming(Menu code 1700)
( MENU → 7. Print )
▶ PRINT Submenu
No Submenus Description
1 Print Label Item Select item(s) which is(are) not printed on label.
Select “Yes” or “No” to print both of original and
2 Markdown
discount information on the label.
3 Print Hardware Set the label type and sensor of printer
Set the format of serial number to print label or
4 Serial Number Format
ticket
5 ADD-UP Total Select add-up total label whether is printed or not
6 Ticket Set printing item for ticket
If you set any of the items to N, they will not be printed on any labels
regardless of the label format.
You can use the PG UP and PG DOWN keys to navigate from page to
page, or you can use the Arrow keys to go through each page 1 line at a
time.
◆ You can press the SAVE key at anytime to save the current data and if
you want to exit without saving, press the ESC key.
118
1. If you do not want to print, enter 0(N),
Origin
Barcodes
8 Ingredient 16
Image
Sales Message
119
2.13.2 Markdown (Menu code 1720)
( MENU → 7. Print → 2. Mark down )
The Markdown Menu is used to determine if both the original and discounted unit
price, total price, weight or quantity information is printed on the label. There are 4 sub-
menus available.
▶ Markdown Sub-menu
No Sub-menu Description
Select “Yes” to display both of original total price and the
1 Total Price Markdown
discounted total price if any. Otherwise, select No .
Select “Yes” to display both of original unit price and the
2 Unit Price Markdown
discounted unit price if any. Otherwise, select No .
Select “Yes” to display both of original weight and the
3 Weight Markdown
discounted weight if any. Otherwise, select No .
Select “Yes” to display both of original quantity and the
4 Quantity Markdown
discounted quantity if any. Otherwise, select No .
120
2.13.3 Printer Hardware (Menu code 1730)
4 Sensor & Motor Set Peel-off sensor, Rewind Motor and Label Paper type
121
2.13.3.1 Print Mode (Menu code 1731)
( MENU → 7. Print → 3. Printer Hardware → 1. Print Mode )
Select “0” for Label Mode, “1” for Ticket Mode or “2” for Continuous Label
Mode.
Enter values for “Width”, “Height”, “Gap Length”, ”Feed” and “End Margin”. If you
press “TEST” key, height and gap length of current label is measured.
122
2.13.3.4 Sensor & Motor (Menu code 1734)
• 1pixel = 0.125mm
123
2.13.3.7 Label Preprint (Menu code 1737)
( MENU → 7. Print → 3. Printer Hardware → 7. Label Preprint )
124
Meaning
• I : Item Code
• N : PLU Number
• P : Price
• U : Unit Price
• W : Weight
• Q : Quantity
• D : Department
• G : group
• A : Ticket Counter (Ticket Mode)
• B : Scale Transaction Counter
• F : PLU Prefix Character
• T : Text Character
• R : Transaction Counter of Each PLU
• L : Clerk Number
• % : Print Fixed Character in the Next Space.
• K : Country Code (For Future)
This section shows how to set printing environments of total label and
item label when you use ADD-UP sales.
125
② Press “0” for “No” or “1” for “Yes” in [ ].
▶ Add-up setting
126
2.13.6.2 Select List Item (Menu code 1762)
Before setting list item, you have to set “Print List” to “Y” in menu 1761.
① Press “2” to get into SELECT LIST
ITEM menu.
Select “Yes” or “No” for “Print Store
Name”, “Print Clerk Name”, “Print Item
Barcode”, “Tax Information”, and “Print
Traceability”.
Ticket Format
Description
Setting
It outputs product list (Detailed item can be set in the
following menu, 1762)
Prt. List (Y/N) ■ Printing the list of each sales item(s).
* In case of “Yes” selected user can go to “List
Item” setting.
It outputs the TTL barcode set at the global barcode
Prt. Total Barcode
■ Printing total barcode on ticket.
It outputs the Total label set at the global label format.
Ticket Prt. Total Label
■ Printing total amount on ticket.
Item
All ticket sections with exclusion of the product list are
Prt. duplicate ticket outputted once more.
■ Printing duplication of ticket
Same ticket including the product list is issued twice
(Print Duplicate Ticket must be set at ‘Y’ for it to be usable)
Prt. List (D. ticket) ■ Printing List of items on duplicated ticket
Note : N=Printing amount of only total price for
duplicate ticket
Prt. Store Name ■ Printing store name on ticket.
Prt. Clerk Name ■ Printing clerk name on ticket.
Prt. Item Barcode ■ Printing every item s barcode on ticket.
List Prt. Tax Information ■ Printing tax information on ticket.
Item
Prt. Traceability ■ Printing traceability information on ticket
Ticket Head Form No. ■ Printing label format No. for ticket head.
Ticket Tail Form No. ■ Printing label format No. for ticket tail.
※ You have to download label format for Ticket Head Form No. and Ticket Tail
Form No. from PC.
127
2.13.6.3 Select Ticket Font Size (Menu code 1763)
( MENU → 7. Print → 6. Ticket → 3. Select Ticket Font Size)
It can designate the size of the letters of the item that is printed in the ticket.
※Size of Subtotal, Tax information, Payment and Print Label cannot be adjusted
128
2.14 Programming Scale Configuration
(Menu code 1800)
( MENU → 8. Scale Config )
This chapter explains how to configure the scale. The main menu of
Scale Configuration is shown as below.
This section is to select sale mode, which have seven different modes in the
following table.
▶ Sale Modes
129
▶ Selecting one of following sale modes, user may select an one-stop setting
for Clerk, Operation, Print, and Prepack mode.
Usually user has to set each option you wish to for clerk, operation, print or prepack
mode. However, user may select simply one-stop sales mode for 7 different
modes-Clerk, Operation, Print, and Prepack mode. User may also set options
for Clerk/Operation mode in MENU 1820 and Print/Prepack mode in MENU 1731.
130
2.14.2 Operation Mode (Menu code 1820)
This section is to select a clerk and operation mode. There are three
different operation modes, REGISTRATION, RE-PACK, MANAGER and
three different clerk modes, NO CLERK, STANDARD CLERK, and
FLOATING CLERK.
▶ Clerk Modes
▶ Operation Modes
131
2.14.3 Department (Menu code 1830)
( MENU → 8. Scale Config → 3. Department )
This section shows how to select current department where scale is being used.
User can use (call up) PLUs only for current department selected in sales mode.
For example, if current department selected is GROCERY user can call up items
registered only in GROCERY department. If user would like to use PLUs registered
in other department than current department he/she should change scale s
department setting. Store No. represents Store Name (or branch number) on
label/ticket printed.
☞ Please refer to “ASCII Code Table” (chapter 4.4) to input special characters in Date
or Time separator.
132
4. Press “PRINT” key to save it and go
Password: When you enter the password, you have to type clerk number(2digit) and
password(4 digit). For example, if your clerk number is 20 and password is 1234, you
133
have to type 201234. Minimum password is 3 digit and maximum password is 6 digit.
If there is no level 3 clerk, you can use default value. (Clerk No:1, password:1, Level:3)
Therefore default password is 011.
• You have to set a level 3 clerk. If there is no level 3 clerk, you can use default
password(011) and if any, you cannot use it.
Clerk level: This value can be from 0 to 3. This level is related to menu
1855(Config permission). If clerk 2 is set to level 2, this clerk can use the
function which is set to level 1, 2 in menu 1855 and cannot use the function
which is set to level 3.
1. Enter password.
• Clerk No. (2 digit) + password (4 digit)
2. New Password
• Enter new password
134
2.14.5.3 List User (Menu code 1853)
EX) 1~10
Permission level is related to clerk level and if the clerk level is lower
than permission level, this clerk cannot access that function. Refer to
clerk level on chapter 2.14.5.1
※ If permission level is “0”, all clerks can access this function.
EX) If you set permission level to 2 for price change key and clerk 1 is set to level
1 and clerk 2 is set to level 2, clerk 1 can not use this key but clerk 2 can use
this key
135
▶ Setting Configuration Permission
136
You can use the PG UP and PG DOWN keys to navigate from page to page,
or you can use the Arrow keys to go through each page 1 line at a time.
137
2.14.5.6 Clerk Key ( Menu code 1856 )
( MENU → 8. SCALE CONFIG → 5. User/Security Con. → 6. Clerk Key )
You can assign Clerk key to clerk. There are 64 Clerk keys and you have
to set these keys in menu 1880 (Key define). See chapter 2.14.8.
For example if you set “A” key to clerk 2 in menu 1880 (Key define), and call
up a PLU and press “A” key in floating sale mode, it is recognized that clerk
no. 2 (LEE) sold this item.
138
2.14.6.1 Display Test (Menu code 1861)
To test the display, press “1” on Test menu screen. It automatically tests
it. You can exit from testing, by pressing “X/ESC” key.
139
2.14.6.5 Printer Sensor Test (Menu code 1865)
( MENU → 8. SCALE CONFIG → 6. Test → 5. Printer Sensor )
140
You can set scale’s environment as below.
▶ Scale Parameter
Menu Sub-menu Setting Value Description
The scale shows discount
Display Discount Info Y/N
information.
Show Clerk Nickname Y/N The scale shows clerk’s nickname
0: Left alignment
1. Display
PLU Name Align 1: Center alignment Set the alignment position of PLU
(Menu
2: Right alignment
code:1871)
Setting whether scroll message is
Enable Scroll msg with PLU Y/N showed up or not when PLU is
called
Touch Calibration Y/N Calibrate the touch screen
Do not use rewind function when
Label prt w.o rewind(x Key) Y/N
you use “X” key
0:Print automatically
1:Need to confirm to
print report and do
not confirm any
more until power
Set confirm method when you print
Confirm prt report on label off
report in label mode
2:Need to confirm to
print report and do
not confirm any
more until you exit
program mode
0:Do not print
1:print in Name1
Print origin for comm. Line Print origin in commodity line
2. Printing 2:print in Name2
(Menu 3:print in Name3
code:1872) Print unit symbol in qty area Y/N Print Qty Symbol in qty area
Print pieces in U. Price area Y/N Print Pieces in unit price area
Print all report within range Y/N Print all report
0:Not use Selection the way and whether
Swedish auto barcode 1:price Auto Code using Swedish automatic barcode
2:Weight Auto Code function
0:Not use
1:alphabet Setting up the type when packing
Print pack type
2:day(Moon, Tue,…) date is printed
3:day,year
0:Do not print
Print Item when return Print return list when it returns
1:Print
Y:Print default label
Print Label when Label #0 form
N:Do not print
Print Total label continuously Y/N Set multiple total label
Save unit price change Y/N Save unit price change
Save Type change Y/N Save type change in PLU
Save mode is active when you turn
Start save mode(start up) Y/N
on the scale
3. Sale Setup
PLU is cleared after printing even
(Menu
code:1873) PLU clr Aft sale(WT.On Tray) Y/N though there is an item on the
platter
If you enter count, it is considered
Print count w.o misc. key Y/N that misc. count condition when
there is no misc. key
141
If there is an item on the platter, it is
considered that misc. weight
Print weight w.o misc. key Y/N
condition when there is no misc.
key
T.price = price + Tax Y/N Tax is included in total price
Shift key instead return Key Y/N Use shift key instead of return key
Use double speed key Y/N Use double speed key
If you double-click, command
Use Double DATE/TIME key Y/N
window will be appear
Setting up to print discounted
Multi-print on discount sale Y/N
product label repeatedly
Setting up to select whether it start
Start auto mode(start up) Y/N
with Auto Mode when it boots
Once you press the number key,
Enable Quick PLU Y/N
PLU is called immediately
Show plu number on key Y/N
Show Number key on sale Y/N
4. Clerk Logout After printing label, automatically
Logoff after transaction Y/N
(Menu clerk log off
code:1874) Clerk log out time(0.1s) 1~99 Set clerk log out time
5. System
Restore
1~20 Select a restore point
(Menu
code:1875)
You can use the PG UP and PG DOWN keys to navigate from page to page,
or you can use the Arrow keys to go through each page 1 line at a time.
142
2.14.8 Function Key Define (Menu code 1880)
You can define function keys to Speed keys. It is recommended that you
define function key to higher number Speed key because you can not
use that PLU key.
143
▶ Function Key.
144
24 [LAST VOID] Void Last Sale
145
Key
146
0 or 9999 PLU Key
147
2.15 Report
2.15.1 Introduction
X mode is used to read (i.e. print and display) sales data. There are variety
of reports that you can generate from X mode. Each of these reports is kept in
two separate counters or “books” called X1 and X2. The X1 and X2 reports
allow you to print reports at any time for either of the reporting periods.
You can use X1 reports to see current daily totals and X2 reports to see
current weekly totals. The time period combination you chose is completely
dependent upon how you use Z1 and Z2.
Remember that you can generate as many X reports as you would like
because X mode does NOT clear any sales data.
148
2.15.3 X1/X2 Report (Menu code 1610/1630)
No Submenus Description
1 Scale Print and display scale sales report
2 PLU Print and display PLU sales report
3 Misc. PLU Print and display Misc. PLU sales report
4 Group Print and display group sales report
5 Department Print and display department sales report
6 Hourly Print and display hourly sales report
7 Clerk Print and display clerk sales report
149
shows “Do you want to print on label?”.
If your label has gap, press 1. if you want to.
print report on ticket, press 0 and change the
setting to Ticket in menu 1731 then change
your label to ticket.
150
2.15.5 X1/X2 PLU Report (Menu code 1612/1632)
151
* “Do you want to print on label?” message
is displayed depending on the setting of
menu 1872
* Confirm Print Report on Label
152
2.15.6 X1/X2 Miscellaneous PLU Report (Menu code 1613/1633)
153
* “Do you want to print on label?” message
is displayed depending on the setting of
menu 1872
* Confirm Print Report on Label
154
2.15.7 X1/X2 Group Report (Menu code 1614/1644)
Note: Because of auto gap sensor printer will not print on where the gap is.??
155
To exit this menu, press “ESC” key.
Note: Misc. If the setting of MENU 1872, “Print All Report within Range” is “No”, the
group with no sales is not printed. But if “Yes”, all group sales data within the range
is printed.
156
Enter department range to check.
Note: If the setting of MENU 1872, “Print All Report within Range” is “No”, the
department with no sales is not printed. But if ”Yes”, all department sales data
within the range is printed.
157
▶ Sample - Department Report
158
You can see hourly sales data by pressing
“PRINT” key.
Note: If the setting of MENU 1872, “Print All Report within Range” is No , the hour
with no sales is not printed. But if “Yes”, all hour sales data within the range is
printed.
159
▶ Sample - hourly Report
160
You can see hourly sales data by pressing
“PRINT” key.
Note: If the setting of MENU 1872, “Print All Report within Range” is No , the hour
with no sales is not printed. But if “Yes”, all hour sales data within the range is
printed.
161
▶ Sample - Clerk Report
162
2.15.11 Z1/Z2 Report (Menu code 1620/1640)
Note1: If the setting of Parameter 598, “Print when Z Report clear” is “No”, you cannot print Z Report.
Note2: If the setting of Parameter 595 “Individual clear(Z report)” is “Yes”, you can clear Scale,
PLU, Misc. PLU, Group, Department, Hourly, Clerk data is cleared separately.
But if you use this function, each report is not same with scale report.
163
2.15.12 Clear All Report (Menu code 1650)
( MENU → 6. Report → 5. Clear All )
164
3. SALES OPERATION
3.1 Basic Operation
This chapter explains basic operation of scale, such as how to set zero,
tare, call up a PLU and override unit price in CL5000 series.
■ Turn ON the scale. The first screen will be seen as below for CL5000-B,P,R and
H type.
165
166
3.2 Zero
You can use the ZERO key to correct for a deviation from zero as long as
there are no PLUs or MISC PLUs called-up. The weight can sometimes drift
from zero due to debris on the platter, leaving objects on the platter for
excessive periods of time, or other environmental factors. To correct this,
remove everything from the platter and press the ZERO key when the stable
indicator “▼” is on. Below is a possible zero drifted state that should be
corrected by simply pressing the ZERO key.
167
3.3 Tare
You can enter tare weights as long as there are no PLUs or MISC PLUscalled-up.
If you need to temporarily override a PLU s tare weight, you must enter the tare
weight first and then call-up that PLU. )There are two ways to enter a tare weight
and both ways will only work if there is no PLU or MISC PLU called-up.
168
3.3.3 How to Clear Tare
169
② Enter the weight of container using
numeric keys.
EX) 200 g
③ Press “TARE key after removing item and container from the platter.
170
3.4 Calling Up a PLU
There are two ways to call up a PLU by using numeric key and preset key(speed key).
Note: Even though you do not press PLU key after entering a PLU number,
PLU will be displayed depending on the setting time. It takes time to call up a
PLU depending on the setting of parameter, 586 “Indirect PLU Call Time”.
171
3.5 Override (FOR key)
The OVERRIDE key is used to temporarily change the pricing of priced PLUs.
If you set program menu 1873(Save unit price change), changed priced is
saved after printing a label.
172
3.5.2 By-Count PLU
173
3.5.3 By-PCS PLU
- PLU# 3.Eggs ( PLU Type : By PCS, Pieces : 3, Unit Price : 30.00$).
Note: - If you set program menu 1873(Save unit price change), changed priced is
saved after printing a label.
- If you set parameter 501(Ride Second Position), you can change unit price
of by-count PLU and pcs of by-pcs PLU directly.
- Discount function is not available when you use OVERRIDE key.
174
3.6 Sales Operation
3.6.1 Weighed Item Operation
EXAMPLE:
- PLU No : 29, PLU Name: ONION, PLU type : by weight, Unit Price : 1.50$,
- Sales Weight =1.0kg
User may call up a PLU by pressing speed key or numeric key. Please refer
to chapter 3.4 for details.
175
④ Remove the item(s) from the platter.
Note: - In “SAVE” & “Prepack” mode the PLU is not automatically cleared
when you remove the item from the platter.
- If you set “PLU clr Aft sale(WT.OnTray)” to “Y” in Menu 1873, PLU is
cleared even though you do not remove the item from the platter.
(See chapter 2.14.7.3 for menu 1873)
l User may call up a PLU by pressing speed key or numeric key. Please refer
to chapter 3.4 for details.
176
③ Press “PRINT” key to print a label and
Note: - In “SAVE” & “Prepack” mode, the PLU called up is not automatically
cleared when you remove the item from the platter.
l User may call up a PLU by pressing speed key or numeric key. Please refer
to page 143 for details.
Note: - In “SAVE” & “Prepack” mode the PLU is not automatically cleared
when you remove the item from the platter.
177
3.7 Discount
Before using discount function, you have to set discount data in menu 1130
of program mode. Discount is different depending on PLU type. (For details,
see chapter 2.4.1)
• 1st Target of Discount: “Discount amount from unit price”=0.50 for weight 0.500.
• 2nd Target of Discount: “Discount amount from unit price”=1.00 for weight 1.000.
① Call up a PLU.
178
④ Place items on the platter. In this case, discount is
Note: - You can set four markdown information in menu 1720 of program
mode.(See chapter 2.13.3)
- If you set “display discount info.” to “Y” in menu 1871 of program
mode, you can see total price and discount information on the display.
(See chapter 2.14.21)
• 1st Target of Discount: “10 % off from unit price” for sales weight 0.500 kg.
• 2nd Target of Discount: “20 % off from unit price” for sales weight 1.000 kg.
① Call up a PLU.
* User may call up a PLU by pressing speed key or numeric key. Please refer
to chapter 3.4 for details.
179
② Place an item on the platter. In this case, discount
is not available because the weight of this item
(0.489 kg) is lower than 1st target(0.500 kg).
180
3.7.3 Unit Price Discount - By PCS PLU
EXAMPLE 2:
- PLU# 30=PREMIUM MANGO, 3 pieces FOR 6.00
• 1st Target of Discount: “Discount amount from unit price”=0.20 for sales
5 pieces.
• 2nd Target of Discount: “Discount amount from unit price”=0.50 for sales
10 pieces.
① Call up a PLU.
Note: - You can set four markdown information in menu 1720 of program
mode.(See chapter 2.13.3)
181
3.8 Add-Up Transaction
If you press the ADD key instead of the PRINT key, you will initiate the
ADD-UP process. You can ADD-UP 399 items maximum.
EXAMPLE 2:
- PLU# 32=SIRLOIN, PLU Type = By-Weight, Unit Price=20.00,
- PLU# 35=T-bone Steak, PLU Type = By-PCS, Pieces=3, Unit Price=6.00
182
④ Press ADD key. PLU is cleared automatically.
Note: - You can press the VOID key to undo the transaction. (See chapter 3.10).
- If you set “Print Item Label” to “Y” in menu 1750 of program mode,
label will be printed whenever you press the ADD key. (See chapter 2.13.3)
- Even though you turn off the scale before printing a grand total label,
add-up data is not cleared.
183
3.9 Clerk Operation
There are three clerk modes as below.
▶ Clerk Modes
☞ To register clerk, refer to menu code 1850 of program mode. (See chapter 2.14.5)
Assumption
* If you want to see total price before completing transaction, press the
ST/TTL key. To print, press the PRINT key.
* Even though you turn off the scale before printing, sales data is not cleared.
If you want to print ticket when you log out, press V1~V64 to log on and press
the PRINT key. You can also check total price by pressing ST/TTL key after log
on.
184
Note: - You have to set Clerk log out time in menu 1874 of program mode.
(See chapter 2.14.7) If you do not call a PLU and do not operate the
scale, time is computed. To set 30 seconds for logout time, enter 300.
If you do not want to log out, enter 0.
- When there is no PLU, you can print ticket again by pressing X key (It
depends on the setting of parameter 599, Print last ticket)
EXAMPLE 2:
Clerk No: 2, Clerk Name: Christine, Clerk Key: V1
PLU#1=Apple, Unit Price 10.00, Weight, 1.2 kg
PLU#2=Orange, Unit Price 20.00, Weight, 1.2 kg
① Call up a PLU.
③ Call up a PLU.
185
④ Place an item and press V1 key. You will
get a label automatically.
Note: - If you are in ADD-UP mode, you can have label for grand total price
by pressing PRINT key. When you turn on the scale, this function is
not active so you have to press ADD key.
EXAMPLE :
Clerk No: 2, Clerk Name: Christine, Clerk Key: V1
PLU#1=Apple, Unit Price 10.00.
PLU#2=Orange, Unit Price 20.00 10 pieces.
① Call up a PLU.
186
② Place an item on the platter and press the V1 key.
Note: - Print mode of floating clerk operation is ticket type as default. If you
want to use label type, you have to change setting in menu 1731 of
program mode. (See chapter 2.13.3)
- You can set ticket item in menu 1761 of program mode. (See chapter
2.13.6)
187
3.10 Void
You can press the VOID key to undo transaction in add-up process or
floating clerk operation.
Assumption)
You sold several items
* You can use the PG UP and PG DOWN keys or the Arrow keys to navigate
up and down the list.
* If price is not same, void list screen is shown on the display automatically.
188
3.11 Payment & Change
▶Payment
You can use PAY key in the add-up process or floating clerk operation.
③ Enter 6.00
189
⑥ Enter 10.00.
Note: - You can set print item in menu 1760 of program mode. (See chapter 2.13.6)
- If there is credit sales, a receipt is printed additionally.
190
3.12 Return
The RETURN key is used to delete erroneous sale transactions. You can
use the RETURN key to undo erroneous sales transactions like pressing the
PRINT key inadvertently, selecting and printing the wrong PLU, an inadvertent
Auto-Print in Pre-Pack mode, or perhaps adjusting the sales totals for a
damaged or ruined package. Whatever the reason, the RETURN function will
decrement returned PLU s transaction counter and sales totals by the
specified amount.
You need to call-up the PLU that you wish to return by either pressing its
corresponding speed key or typing its number.
0) By weight PLU : You need to enter the total price and weight that was printed
on the return PLU s label
1) By count PLU: You need to enter the total price and quantity that was printed on
the return PLU s label
Note: - If you set Shift key instead return key to “Y” in menu 1873 of program
mode, you cannot use return function. (See chapter 2.14.21)
- If parameter 596 X/Z Report is not set, this function will not operated.
191
3.13 Prepack Key
Pre-Pack mode, it prints labels automatically. When it is in MANUAL mode,
you must press the PRINT key (or ADD key) to get a label. In Pre-Pack mode,
you can not select AUTO mode. Pre-Pack works like AUTO and SAVE mode
except that the weight does not need to return to zero for every auto-print.
192
① Press PREPACK key and call up a PLU
* User may call up a PLU by pressing speed key or numeric key. Please refer
to Menu code 1160.
Note: - If the scale is in Prepack mode then it will always auto-print if the Total
price is greater than 0.00 and:
193
3.14 X Key
The X key is used to print multiple transactions for the same PLU. The X
key operation is called the Multi-Label function.
EXAMPLE:
Speed key #1= “Onion” preset key, Unit price=1.50, Sales Weight=1.0kg,
① Call up a PLU
* You can call up a PLU by pressing speed key key or numeric key. Please
refer to chapter 3.4 for details.
194
④ Remove the item(s) from the platter.
Note: - If you set “Label Prt. w.o Rewind (X Key)” to “Y” in menu 1872 of
program mode, the scale does not check peel-off, so you have to
press FEED key after printing is done. (See chapter 2.14.21)
195
3.15 How to Change Sell By Date/Time
① Call up a PLU
Note: - To use EDIT SELL key, you have to set this key in menu 1880 of
program mode. (See chapter 2.14.8)
196
3.16 How to Change Origin
① Call up a PLU
Note: - To use ORIGIN key, you have to set this key in menu 1880 of program
mode. (See chapter 2.14.8)
197
3.17 How to Change PLU Type
Note: If you set “Save Type change” to “Y” in menu 1873 of program mode,
changed PLU type is saved. (See chapter 2.14.7)
☞ If you change by-Weight PLU to by-count PLU, quantity is set 1 and unit
price is same.
☞ If there is discount information on PLU, you can not change PLU type.
198
3.18 Direct Discount
If there is no discount information in PLU, you can use this function.
Note: - To use Fixed Price Key, you have to set this key in menu 1880 of
program mode. (See chapter 2.14.8)
199
3.18.2 % Discount Price Key
Note: - To use % DISCOUNT key, you have to set this key in menu 1880 of
program mode. (See chapter 2.14.8)
200
3.19 PLU Connection
3.19.1 Referenced PLU Function
If you press REFERENCE key(Functinos key#:9) after calling up a PLU which
has reference information, reference will be shown on the display.
◆ To use this function, you have to set reference department and reference
PLU when you create PLU.
◆ To use this function, you have to set reference department and reference
PLU when you create PLU.
◆ To use this function, you have to set Linked department and Linked
PLU when you create PLU.
201
- You have to set Parameter 597(Prepack report) to use this function. Also,
Parameter 596 should be set to Y
APPENDIX
1. Label Format
There are fixed label format and user label format
202
1.1 Label Format Sample
1 2
3 4
5 6
203
7 8
9 10
11 12
13 14
204
15 16
17 18
19 20
205
21 22
23 24
206
25 26
27 28
29 30
207
31 32
33 34
35 36
37 38
208
39 40
41 42
43 44
45
209
1.2 Label Format’s field Sample
210
2. ASCII Code Table
▶ Microsoft Window Codepage 1252
Note: To enter A , first you have to read 40 in a row and 01 in a column and type 41.
211
3. Window Character Set Information
212
MEMO
213
MEMO
214
MEMO
215
MEMO
216
MEMO
217
MEMO
218
MEMO
219
MEMO
220
221
뒷표지
222