Case Study Worst Redo
Case Study Worst Redo
Case Study Worst Redo
Check Point
① Check if water leaks from between tub front and ① Replace Assy Diaphragm
diaphragm or underneath
- Check for water leaks in front of the tub
(Common issue regarding WF42H5*** Model)
- 1/12 -
Symptom Guide – [Front Load] Water Leakage
Check Point
- 2/12 -
Symptom Guide - [Front Load] Door is not locking/unlocking
Check Point
Step 1
Step 2
- Unlocking
. Check the voltage
at White wire of CN10 and
White wire of Power relay
Locking Position Unlocking Position
during door is unlocked.
Step 3
OK NG
- 3/12 -
Symptom Guide - [Front Load] 1E (Pressure Sensor Error)
Check Point
Step 1
Step 2
③② ① ③② ①
Normal : DC 1.7V~5V
Step 3
- 4/12 -
Symptom Guide - [Front Load] Detergent Drawer Issue
Check Point
<Before> <After>
<Before> <After>
Check Point
③ Check the signal from Mems Sensor to Sub PBA ③ Replace Mems Sensor
- Check the voltage at mems signal wires of CN6 If the signal of Sub PBA is ok.
after disconnecting connector. Otherwise, replace Sub PBA
(Normal Voltage : DC 1.7 ~ 5V)
But the color of mems wire may vary by model
as followings
- 6/12 -
Symptom Guide - [Dryer] Unit is not Heating
Check Point
L2 N L1 L2 N L1
L2 N L1
※ Abnormal Condition
< Heater > < Power and Motor>
Abnormal : O V Abnormal : O V
- 7/12 -
Symptom Guide - [Dryer] Unit is not Heating
Check Point
RY7 CN1
Standby : AC 1.5 ~ 3V
- 8/12 -
Symptom Guide - [Dryer] Unit is not Heating
Check Point
③ Replace thermostat 3
If there is no continuity
③ Check the thermostat 3
(Part Code DC47-00015A)
- Switch the meter to continuity mode to check
thermostat 3
If it sends out beeping sounds, Thermostat3 is ok.
- 9/12 -
Symptom Guide - [Dryer] Unit is weak heating
Check Point
60 ℃ 120℉
※ How to enter Temperature display Mode ※ How to enter Temp display mode
by Model.
- Press Adjust time△+ Adjust time▽ for 10 seconds - DV42H5**,45H6**, 56H91**,
during power is on until it sends beeping sounds, 56H9***
→ Adjust time△+ Adjust time▽
And then, press Temp key until Number 5 is display. - DV400,DV422**,456**, DV50F**,
(Number 5 is temperature data) DV45H7***,48H7*** :
→ Adjust ▽ + Wrinkle prevent
- Temp Key is common
39.6℃
- 10/12 -
Symptom Guide - [Dryer] Unit is not Spinning
Check Point
- 11/12 -
Symptom Guide - [Dryer] Unit is not Spinning
Check Point
① Check the Micro S/W on Assy Motor ① Replace the Micro S/W
If there is no continuity
- Check the Micro S/W by continuity mode
(Part Code : 3405-001077)
during idler is engaged
Idler is engaged
Idler is disgaged
Short Open
① If All steps were normal, it is highly likely that ① Replace Assy Motor
②⑥ ④ ③ ⑤ ①
②⑥ ④ ③ ⑤ ①
- 12/12 -