Error Code Guide
Error Code Guide
Washer
A-Type • Affective Model
→ WA45H7*** / WA48H7*** / WA56H9***
- To enter the Diagnostic Code Check Mode, Press the designated Key of
Each Model during Service Mode.
B-Type • Affective Model
→ WA50F9*****
- To enter the Diagnostic Code Check Mode, Press the designated Key of
Each Model during Service Mode.
C-Type • Affective Model
→ WA400*** / WA422***
- To enter the Diagnostic Code Check Mode, Press the designated Key of
Each Model during Service Mode.
D-Type • Affective Model
→ WA456***
- To enter the Diagnostic Code Check Mode, Press the designated Key of
Each Model during Service Mode.
Diagnotic Code Diagnostic Item Trouble contents Image 1 Image 2
- The water level frequency is continuously over 30kHz or below
Pressure Hose
15kHz for 10sec
Clogged
① Water Level Sensor Fault
Pressure Level
1E Sensor
(Resistance Pin 1-2 : Open, 2-3 : Open, 1-3 : Short)
② Wire Harness connection problem
Wire Harness
③ The pressure hose is folded
Main PBA
④ Main PBA fault (DV 2~3V)
① Motor overloaded due to too much laundry (Non sensing)
or Coil Open (cut)
Motor (Stator)
② Check Resistance of motor (U-V-W)
3E Wire Harness
→ The Resistance : approximately 11Ω
Main PBA
③ Wire Connection of hall sensor terminal
④ Main PBA fault
Hall Sensor ① Defective Hall Sensor
3E1 Wire Harness ② The motor hall sensor terminal is not connected
Main PBA ③ Main PBA fault
Wire Harness ① The Motor wire connection on Main PBA
3E2 Main PBA ② Main PBA fault
- Water level does not increase more than 100Hz
Hose Water from previous water level on every 3min.
Installation - Water level does not reach set water level for 40 mins
Water Valve ① Hose Kinked
4E/nF Wire Harness ② Water Valve Defect (Check resistance approximately 1K~2KΩ)
Water Valve or filter blockage
(Filter Blockage) ③ Wire Harness connection problem
④ Main PBA (Check for AC 120V) / ⑤ Hose Pressure Hole
Drain Hose
- If it does not reach target water level after 15min draining
Installation
① Drain Hose Installation
Drain Pump
② Drain Pump defect (Check for resistance approximately 26.4Ω)
5E/n Drain Pump (Filter
or Filte Blockage
Blockage)
③ Wire Harness connection problem
Wire Harness
④ Main PBA (Check for AC 120V)
PBA
Mems Sensor
- The signal of tub location is out of normal range in Mems
(WA456**,45H7200**,
during spining (Unbalance status)
48H7400)
① Check for Mems Sensor
Wire Harness
(WA456**,45H7200**,48H7400 have Mems Sensor, For Other
Sub PBA
8E/8E1 (WA456**,45H7200**,
model Mems IC located on Main PBA)
② Wire Harness connection problem
48H7400)
③ Check for SUB PBA input voltage : DC
Main PBA
5V(WA456***,45H7200***,48H7400***)
(WA400**,422***,45H
④ Check for Main PBA (WA400**,422***,45H7000**)
7000**)
- When there is communication error between main PBA & sub
Wire Harness
PBA is for over 24sec
AE Sub PBA
① Check for Wire connection between Main PBA and Sub PBA
Main PBA
② Check IF the sub PBA is short-circuited because of moisture
Control Panel - Any button on control panel is continually pressed for over 30s
bE1/bE2 Sub PBA ① A button other than the Power button is continually pressed.
Main PBA ② Tact S/W on Main PCB relay fault
- Reed S/W in Door-Lock S/W does not detect door is close.
Door-Lock S/W ① Check Door is properly closed
dE/dS Wire Harness ② Check if there is a deformation of the door hook
Main PBA ③ Fault of Reed S/W which is detecting if door is open or close
④ Main PBA Fault
- In case that it fails to lock / unlock continuously door lock S/W
Door-Lock S/W seven times
fL/LO/dE1 Wire Harness ① Check the resistance of terminal 1-2 in door lock s/w
Main PBA (The Resistance : approximately 33 ~ 46Ω)
② Check Door-Lock S/W curcuit in Main PBA
- If water level frequency above 30kHz is detected for 5 sec
Drain Hose during wash / rinse cycle.
Installation ① Water leaks from diaphragm, pump drain, heater, tub
LE Detergent Usage or all hoses etc.
Main PBA ② Drain hose is inserted into drainage too deeply.
③ Water level sensor / hose defective
- If water level frequency below 21kHz is detected for 10 sec.
- This can be caused by continuous water supply.
① Check the frequency value of water level sensor under the
Water Valve condition no load
Water Level Sensor → If the value is normal, replace the water level sensor
OE Main PBA (Normal : approximately 24.6~25.6kHz)
Detergent Usage → How to Check water level
(with no power, press spin + soil level + power at the same time
and then, turn Knob dial 3 turns to CCW direction)
② Check for detegent that customer use if it is HE
Unit Installation
- If washer detects unbalance 3 times
(Leveling)
① Check Unit is properly leveled
Load Size
C/UE (Overloaded)
② Check customer wash right type of laundry or too sall size
or overloaded
Load Type
③ Check for Damper tension
Damper
Thermistor - If washer detects that water temperature is lower than – 3℃
(Temperature during heater on
Sensor) ① Check for wire connection
tE/tE1 Wire Harness ② Check for resistance of thermistor
Connection ※ Normal resistance : Approximately 60~61 ㏀ (20℃)
Main PBA ③ Check for Main PBA (DC5V)
- If the position detection signal is not received 15sec after the
clutch motor starts, the spin drum is shaken left and right and
Wire Harness then the motor is restarted
PE Clutch Motor ① Check for wire connection of clutch motor
Coupler ② Check for resistance between clutch motor’s terminals(1 and 3)
※ Normal Resistance : 2.18kΩ±7% (20℃)
③ Check If Coupler on Clutch is broken then replace
- The hall sensor location detection fails 15 times after running the
clutch-motor and aligning the motor left and right.
Wire Harness
① Check the connection of clutch motor’s housing
PE1 Clutch Motor Hall
② Check the resistance on the main PCB motor
Sensor
(Between pins 2 and 4, 3 and 4 of the four (4) pins)
→ Normal Resistance: Approx. 2 to 4 MΩ
- This occurs when too much foaming is detected
sud Customer Usage ① Check what kind of and how much detergent is used.
If customers use non HE or too much detergent
E-Type • Affective Model
→ WF42H5*** / WF45H6*** / WF56H9***
- To enter the Diagnostic Code Check Mode, Press the designated Key of
Each Model during Service Mode.
F-Type • Affective Model
→ WF393*** / WF405*** / WF433*** / WF455***
- To enter the Diagnostic Code Check Mode, Press the designated Key of
Each Model during Service Mode.
G-Type • Affective Model
→ WF457***
- To enter the Diagnostic Code Check Mode, Press the designated Key of
Each Model during Service Mode.
Diagnotic Code Diagnostic Item Trouble contents Image 1 Image 2
- The water level frequency is continuously over 30kHz or
Pressure Hose below 15kHz for 10sec
Clogged ① Water Level Sensor Fault
1E Pressure Level Sensor (Resistance Pin 1-2 : Open, 2-3 : Open, 1-3 : Short)
Wire Harness ② Wire Harness connection problem
Main PBA ③ The pressure hose is folded
④ Main PBA fault (DV 2~3V)
① Motor overloaded due to too much laundry (Non sensing)
or Coil Open (cut)
Motor (Stator)
② Check Resistance of motor (U-V-W)
3E Wire Harness
→ The Resistance : approximately 11Ω
Main PBA
③ Wire Connection of hall sensor terminal
④ Main PBA fault
Hall Sensor ① Defective Hall Sensor
3E1 Wire Harness ② The motor hall sensor terminal is not connected
Main PBA ③ Main PBA fault
Wire Harness ① The Motor wire connection on Main PBA
3E2 Main PBA ② Main PBA fault
- Water level does not increase more than 100Hz from
Hose Water
previous water level on every 3minute
Installation
① Check If Hose is Kinked or filter on water valve is blocked
Water Valve
4E/nF Wire Harness
② Check Water Valve resistance (approximately 1K~2KΩ)
③ Wire Harness connection problem
Water Valve
④ Main PBA (Check for AC 120V)
(Filter Blockage)
⑤ Hose Pressure Hole
Drain Hose
- If it does not reach target water level after 15min draining
Installation
① Drain Hose Installation
Drain Pump
② Drain Pump defect
5E/n Drain Pump
(Check for resistance approximately 26.4Ω) or Filte Blockage
(Filter Blockage)
③ Wire Harness connection problem
Wire Harness
④ Main PBA (Check for AC 120V)
PBA
Mems fault (Front) - The signal of tub location is out of normal range in Mems during
8E/8E1 Wire Harness spining (Unbalance status)
Sub PBA - Tub location data sent from Mems is not matched with normal
range in Mems for 2 sec
Mems fault (Rear)
① Check for Mems Sensor
8E2 Wire Harness
② Wire Harness connection problem
Sub PBA
③ Check for SUB PBA input voltage : DC 5V
- When there is communication error between main PBA & sub PBA
Wire Harness
is for over 24sec
AE/AE6 Sub PBA
① Check for Wire connection between Main PBA and Sub PBA
Main PBA
② Check if the sub PBA is short-circuited because of moisture
Control Panel - Any button on control panel is continually pressed for over 30 sec.
bE1/bE2 Sub PBA ① A button is continually pressed.
Main PBA ② Tact S/W on Main PCB relay fault
because of moisture
Sensor Plate
- If sensor bar is short in "tSt" or "SPn" Test mode.
tUH (Sensor Bar)
① Check If sensor bar is short when a drum is empty
Main PBA