Rbsu User Guide
Rbsu User Guide
User Guide
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express
warranty statements accompanying such products and services. Nothing herein should be construed as constituting and additional warranty. HP
shall not be liable for technical or editorial errors or omissions contained herein.
Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212,
Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S.
Government under vendor's standard commercial license.
Microsoft, Windows, and Windows Server are U.S. registered trademarks of Microsoft Corporation.
Intel is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries.
Intended audience
This document is for the person who installs, administers, and troubleshoots servers and storage systems.
HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards
in products with hazardous energy levels.
Contents
Introduction .................................................................................................................................. 7
Overview ................................................................................................................................................. 7
Running RBSU........................................................................................................................................... 7
Contents 3
Advanced Options Menu (G6 servers) ....................................................................................................... 60
Advanced System ROM Options (G6 servers) ................................................................................... 61
Video Options (G6 servers) ............................................................................................................ 68
Thermal Configuration (G6 servers) ................................................................................................. 68
Service Options (G6 servers)........................................................................................................... 69
Advanced Performance Tuning Options (G6 servers).......................................................................... 71
Drive Write Cache (G6 servers) ...................................................................................................... 75
Asset Tag Protection (G6 servers)..................................................................................................... 76
System Default Options (G6 servers) .......................................................................................................... 77
Restore Default System Settings (G6 servers) ..................................................................................... 78
Restore Settings/Erase Boot Disk (G6 servers) ................................................................................... 79
User Default Options (G6 servers).................................................................................................... 80
Utility Language (G6 servers) .................................................................................................................... 81
RBSU menu (HP ProLiant G5 and earlier servers or server blades) .................................................... 82
RBSU menu overview ............................................................................................................................... 82
System Options ....................................................................................................................................... 83
Embedded Serial Port A ................................................................................................................. 84
Embedded Serial Port B.................................................................................................................. 84
Virtual Serial Port........................................................................................................................... 85
Optional LPT Port........................................................................................................................... 86
Optional LPT Mode Support ............................................................................................................ 86
Integrated Diskette Controller .......................................................................................................... 86
NUMLOCK Power-On State ............................................................................................................ 86
Embedded NICs............................................................................................................................ 87
Diskette Write Control .................................................................................................................... 87
Diskette Boot Control...................................................................................................................... 87
Advanced Memory Protection ......................................................................................................... 87
USB Control.................................................................................................................................. 88
USB 2.0 EHCI Controller ................................................................................................................ 89
Power Regulator for ProLiant ........................................................................................................... 89
USB External Port Capability ........................................................................................................... 90
Ultra Low Power State .................................................................................................................... 91
PCI Devices ............................................................................................................................................ 92
Standard Boot Order (IPL)......................................................................................................................... 93
Boot Controller Order .............................................................................................................................. 93
Date and Time ........................................................................................................................................ 94
Server Availability ................................................................................................................................... 94
ASR Status .................................................................................................................................... 95
ASR Timeout ................................................................................................................................. 95
Thermal Shutdown ......................................................................................................................... 95
Wake-On LAN .............................................................................................................................. 95
POST Speed Up ............................................................................................................................ 95
POST F1 Prompt ............................................................................................................................ 95
Power Button................................................................................................................................. 96
Automatic Power-On ...................................................................................................................... 96
Power-On Delay ............................................................................................................................ 96
Server Passwords .................................................................................................................................... 96
Set Power-On Password ................................................................................................................. 97
Set Admin Password ...................................................................................................................... 97
Trusted Platform Module ................................................................................................................. 97
Network Server Mode.................................................................................................................... 99
QuickLock .................................................................................................................................... 99
BIOS Serial Console/EMS Support ............................................................................................................ 99
Contents 4
BIOS Serial Console Port .............................................................................................................. 100
BIOS Serial Console Baud Rate ..................................................................................................... 101
EMS Console .............................................................................................................................. 101
BIOS Interface Mode ................................................................................................................... 102
Server Asset Text ................................................................................................................................... 102
Set Server Info Text ...................................................................................................................... 102
Set Administrator Info Text ............................................................................................................ 103
Set Service Contact Text ............................................................................................................... 104
Custom POST Message ................................................................................................................ 104
Advanced Options Menu ....................................................................................................................... 104
Multi-Processor Specification (MPS) Table Mode .............................................................................. 105
ROM Selection............................................................................................................................ 106
Restore Default System Settings...................................................................................................... 106
Restore Settings/Erase Boot Disk ................................................................................................... 106
User Default Options.................................................................................................................... 107
NMI Debug Button....................................................................................................................... 107
Virtual Install Disk ........................................................................................................................ 107
Secondary IDE Channel Support.................................................................................................... 107
BIOS Enhanced RAID ................................................................................................................... 108
Node Interleaving........................................................................................................................ 108
Serial Number ............................................................................................................................ 108
Product ID .................................................................................................................................. 108
Drive Write Cache ...................................................................................................................... 108
SATA Software RAID.................................................................................................................... 108
Optional PCI-X Riser Fan Monitoring .............................................................................................. 108
Processor Options ....................................................................................................................... 109
Power Supply Requirements Override............................................................................................. 110
Embedded VGA Control............................................................................................................... 110
Utility Language .................................................................................................................................... 111
Contents 5
Configuration Replication Utility .................................................................................................... 125
Array Configuration Replication Utility ........................................................................................... 127
Contents 6
Introduction
Overview
HP ProLiant Generation 2 and later servers have a configuration utility embedded in the system ROM. The
configuration utility, RBSU, starts when you press the F9 key from the startup sequence.
RBSU performs a wide range of configuration activities that may include:
• Configuring system devices and installed options
• Displaying system information
• Selecting the primary boot controller
• Configuring online spare memory
IMPORTANT: Menu options may differ from those in this document, depending on specific
server options.
Based on the generation of the server blade, this user guide is divided into two sections:
• HP ProLiant G6 servers or server blades ("RBSU menu (HP ProLiant G6 servers or server blades)" on
page 9)
• HP ProLiant G5 and earlier servers or server blades (including the HP ProLiant servers and server
blades with AMD processors) ("RBSU menu (HP ProLiant G5 and earlier servers or server blades)" on
page 82)
Running RBSU
1. To run RBSU and modify configuration settings, press the F9 key when prompted during the startup
sequence.
2. Modify configuration settings as needed.
3. Exit RBSU by pressing Esc at the main menu. To confirm configuration setting changes, reboot the
system when exiting RBSU.
Introduction 7
A confirmation to exit displays on the screen, and the current boot controller also displays for
reference purposes.
Introduction 8
RBSU menu (HP ProLiant G6 servers or server
blades)
IMPORTANT: Menu options may differ from those in this document, depending on specific
server options.
On the right-hand side of the screen, a window displays basic server information, including the server
model, serial number, BIOS version, backup BIOS version, memory installed, and processors installed.
Pressing the F1 key when any sub-menu option is highlighted enables you to view a description of that
feature. While the menus are provided in various languages, the help text is provided in English only.
The CLI mode of RBSU ("CLI Mode Selection" on page 119) is a command-prompted interface that
provides equivalent functionality to the menu-based mode.
IMPORTANT: Menu options may differ from those in this document, depending on specific
server options.
For detailed information about iLO configurations, refer to the HP Integrated Lights-Out User Guide on the
Documentation CD or to the HP website (http://www.hp.com/servers/lights-out).
IMPORTANT: Menu options may differ from those in this document, depending on specific
server options.
The PCI Devices menu displays the configuration settings of the PCI devices installed in the server and
allows you to modify the IRQ. Multiple PCI devices can share an interrupt.
To disable a device, select the device and press the Enter key. A menu is displayed with options to
change the IRQ, as well as to disable the device.
NOTE: Only IRQs that are modified in RBSU retain the change during the next reboot. IRQs on
PCI devices that have not been modified are subject to change during reboot.
IMPORTANT: When the PCI Hot Plug driver is installed on servers with Microsoft® Windows®
2000 or Windows Server® 2003, disabling a single PCI controller also disables all controllers
on the same PCI bus. To avoid disabling other controllers on the bus, remove the single PCI
controller.
NOTE: If you enable or disable a device, restart the server. Changes do not take effect until
after reboot.
NOTE: Changes made to the Boot Controller Order in the ORCA Utility are reflected in this
menu.
IMPORTANT: The TPM menus appear only if the TPM kit is installed.
CAUTION: When a TPM is installed and enabled on the server, data access is locked (if the
TPM is being used by the OS) if you fail to follow the proper procedures for updating the
system or option firmware, replacing the system board, replacing a hard drive, or modifying
OS application TPM settings.
For information on installing and enabling the TPM module option, see the HP Trusted Platform Module
Option Installation Instructions that ships with the option.
Disabling TPM Functionality disables the BIOS secure startup but still allows the TPM to be visible to the
operating system. The TPM can respond to most commands in this mode.
Selecting Disabled may prevent the server from booting to a TPM-aware operating system.
The BIOS Serial Console/EMS Support option configures the serial port to view POST error messages and
runs RBSU remotely through a serial connection to the server COM port or iLO 2 Virtual serial port. The
remote server does not require a keyboard or mouse.
For more information about BIOS Serial Console, see the BIOS Serial Console User Guide on the
Documentation CD or the HP website (http://www.hp.com/support/smartstart/documentation).
BIOS Serial Console design supports VT100+ emulation. For more information, see "Command Line
Interface Overview (on page 119)."
When viewed in BIOS Serial Console, the RBSU main menu looks slightly different from the local server
view.
The following menu options are available:
• BIOS Serial Console Port (G6 servers) (on page 53)
• BIOS Serial Console Baud Rate (G6 servers) (on page 54)
• EMS Console (G6 servers) (on page 55)
• Server Name defines a two-line name identifying the server. A maximum of 14 characters can be
entered on each line.
• Server Asset Tag defines a two-line asset tag to identify the server. A maximum of 16 characters can
be entered on each line.
• Server Primary OS defines a three-line description of the primary OS of the server. A maximum of 14
characters can be entered on each line.
• Other Text defines two lines of additional text describing the server. A maximum of 14 characters
can be entered on each line.
• Admin Name Text defines a two-line description for the server administrator name. A maximum of
14 characters can be entered on each line.
• Admin Phone Number Text defines two lines of text for the server administrator phone number. A
maximum of 14 characters can be entered on each line.
• Admin Pager Number Text defines two lines of text for the server administrator pager number. A
maximum of 14 characters can be entered on each line.
• Other Text defines two lines of additional text relating to the server administrator. A maximum of 14
characters can be entered on each line.
• Service Name Text defines a two-line description for the service contact name. A maximum of 14
characters can be entered on each line.
• Service Phone Number Text defines two lines of text for the service contact phone number. A
maximum of 14 characters can be entered on each line.
• Service Pager Number Text defines two lines of text for the service contact pager number. A
maximum of 14 characters can be entered on each line.
• Other Text defines two lines of additional text relating to the service contact. A maximum of 14
characters can be entered on each line.
IMPORTANT: Menu options may differ from those in this document, depending on specific
server options.
WARNING: When enabled, pressing the NMI Debug Button on the system board during
normal OS operation generates a Blue-Screen Trap, ABEND, or Panic, and halts the system.
IMPORTANT: Menu options may differ from those in this document, depending on specific
server options.
On the right-hand side of the screen, a window displays basic server information, including the server
model, serial number, BIOS version, backup BIOS version, memory installed, and processors installed.
NOTE: A service number is reported below the serial number on the HP ProLiant DL760 Server
only.
NOTE: Pressing the F1 key when any sub-menu option is highlighted allows you to view a
description of that feature. Please note that all menus are in English only.
The CLI mode of RBSU ("CLI Mode Selection" on page 119) is a command-prompted interface that
provides equivalent functionality to the menu-based mode.
System Options
The System Options menu enables basic I/O server configuration with the following options:
• Embedded Serial Port A (on page 84)
• Embedded Serial Port B (on page 84)
• Virtual Serial Port (on page 85)
• Optional LPT Port (on page 86)
• Optional LPT Mode Support (on page 86)
• Integrated Diskette Controller (on page 86)
• NUMLOCK Power-On State (on page 86)
• Embedded NICs (on page 87)
• Diskette Write Control (on page 87)
• Diskette Boot Control (on page 87)
• Advanced Memory Protection (on page 87)
• USB Control (on page 88)
• USB 2.0 EHCI Controller (on page 89)
• Power Regulator for ProLiant (on page 89)
• USB External Port Capability (on page 90)
• Ultra Low Power State (on page 91)
NOTE: Embedded Serial Port options may be named Embedded COM Port options,
depending on the server.
NOTE: Embedded Serial Port options may be named Embedded COM Port options,
depending on the server.
NOTE: The Virtual Serial Port option requires iLO Firmware version 1.55 or later.
When enabling PXE or iSCSI Boot support, the NIC does not display in the Standard Boot Order (IPL) until
the next reboot.
• The Advanced ECC Support (maximum memory) setting disables additional resiliency and provides
the largest memory capacity to the OS.
• The Online Spare with Advanced ECC Support setting requires a single group of spare modules and
provides automatic failover of degraded modules in the system while it is running.
• The Mirrored Memory with Advanced ECC Support option provides protection against uncorrectable
memory errors that would otherwise result in system failure. DIMM banks A and B are mirrored by
DIMM banks C and D on the same memory board. The failed memory can be replaced while the
system is running.
Mirrored DIMM pairs must be the same size to allow selection of single-board mirrored memory or
dual-board mirrored memory. Pairing different size DIMMs results in the following caution:
Current memory configuration does not support Online Spare.
USB Control
The USB Control menu determines how USB ports and embedded devices operate at startup:
• When USB Enabled is selected, all USB ports and embedded devices are enabled.
• When USB Disabled is selected, all USB ports and embedded devices are disabled.
• When Legacy USB Disabled is selected, all USB ports are enabled under a USB-aware OS, but USB
is not supported during POST or RBSU. Legacy USB Disabled also disables iLO 2 virtual devices.
NOTE: Running external USB ports at USB 2.0 with Microsoft® Windows Server® 2003 or
Microsoft® Windows Server® 2003 x64 causes delays during installations.
Ultra Low Power State is supported only on HP ProLiant servers with AMD processors.
NOTE: Only IRQs that are modified in RBSU retain the change during the next reboot. IRQs on
PCI devices that have not been modified are subject to change during reboot.
IMPORTANT: When the PCI Hot Plug driver is installed on servers with Microsoft® Windows®
2000 or Windows Server® 2003, disabling a single PCI controller also disables all controllers
on the same PCI bus. To avoid disabling other controllers on the bus, remove the single PCI
controller.
NOTE: If you enable or disable a device, restart the server. Changes do not take effect until
after reboot.
NOTE: Changes made to the Boot Controller Order in the ORCA Utility are reflected in this
menu.
Server Availability
The Server Availability menu includes options that configure the ASR features:
• ASR Status (on page 95)
• ASR Timeout (on page 95)
• Thermal Shutdown (on page 95)
• Wake-On LAN (on page 95)
• POST Speed Up (on page 95)
• POST F1 Prompt (on page 95)
• Power Button (on page 96)
• Automatic Power-On (on page 96)
• Power-On Delay (on page 96)
ASR Timeout
The ASR Timeout option sets a timeout limit for resetting a server that is not responding. When the server
has not responded in the selected amount of time, the server automatically resets. The available time
increments are:
• 10 minutes
• 15 minutes
• 20 minutes
• 30 minutes
• 5 minutes
Thermal Shutdown
The Thermal Shutdown option is a toggle setting that determines when the server automatically powers
down due to dangerous temperatures. When the setting is enabled (default), the Advanced System
Management Driver initiates a system shutdown when the temperature reaches within 5 degrees of critical
level. When the setting is disabled, the Advanced System Management Driver shuts down the system at
critical level.
Wake-On LAN
The Wake-On LAN option is a toggle setting that enables or disables the Wake-On LAN feature. When
set to Enabled, the server can be powered up remotely using a network controller. When changing to
Enabled, the following caution displays:
When enabling Wake-on LAN, remove all power cords before adding or
removing any adapters. Some adapters can cause the system to power on
when added or removed.
POST Speed Up
The POST Speed Up option is a toggle setting that enables or disables the extended power-up memory
test. When POST Speed Up is set to Enabled, the extended power-up memory test is not executed, and
the server powers up more quickly.
POST F1 Prompt
The POST F1 Prompt option is a toggle setting that configures the server so the F1 key must be pressed to
proceed when an error is encountered during the power-up sequence. A series of system tests executes
during POST before continuing with the following:
• If failures occur that allow the system to continue operating, the system continues to boot but posts a
message.
NOTE: The POST F1 Prompt setting is enabled by default in ProLiant ML and DL servers and is
disabled by default in BL servers.
Power Button
Disabling the Power Button feature causes the momentary power button to stop functioning under any OS.
The Power Button feature does not override the 4-second hold-down of the server power button.
Automatic Power-On
The Automatic Power-On feature enables the server to automatically power on when auxiliary power is
applied to the server.
Power-On Delay
The Power-On Delay feature delays the server from powering on for a specified time to prevent power
usage spikes when multiple servers power up after a power loss. Wake-on LAN, RTC wake-up, and iLO 2
Virtual Power Button events override the delay and immediately power on the server.
The Power-On Delay options are:
• Disabled
• 15-second delay
• 30-second delay
• 45-second delay
• 60-second delay
• Random delay
Server Passwords
The Server Passwords menu includes options that configure the password environment of the server:
• Set Power-On Password (on page 97)
• Set Admin Password (on page 97)
• Trusted Platform Module (on page 97)
• Network Server Mode (on page 99)
• QuickLock (on page 99)
TPM Functionality
Enabling TPM Functionality enables the TPM and BIOS secure startup. The TPM is fully functional in this
mode.
CAUTION: When a TPM is installed and enabled on the server, data access is locked if you
fail to follow the proper procedures for updating the system or option firmware, replacing the
system board, replacing a hard drive, or modifying OS application TPM settings.
For information on installing and enabling the TPM module option, see the HP Trusted Platform Module
Option Installation Instructions that ships with the option.
Disabling TPM Functionality disables the BIOS secure startup but still allows the TPM to be visible to the
operating system. The TPM can respond to most commands in this mode.
Selecting Disabled may prevent the server from booting to a TPM-aware operating system.
TPM Visibility
The TPM Visibility option provides the ability to hide the TPM from the operating system. When the TPM is
hidden, BIOS secure startup is disabled, and the TPM does not respond to any commands from any
software.
Hiding the TPM may prevent the server from booting to a TPM-aware operating system.
TPM Clear
The TPM Clear option allows the user to reset the TPM to factory settings, clearing any assigned
passwords, keys, or ownership.
Clearing the TPM may prevent the server from booting to a TPM-aware operating system.
IMPORTANT: Network server mode cannot be enabled until the power-on password has been
established.
QuickLock
The QuickLock option is a toggle setting that either enables or disables the QuickLock feature. When set
to Enabled, the keyboard is locked by pressing the Ctrl+Alt+L keys. The keyboard remains locked until the
power-on password is typed.
NOTE: If the power-on password is disabled at the power-on key prompt, the QuickLock
feature remains inactive until the password is changed in RBSU.
The BIOS Serial Console/EMS Support option configures the serial port to view POST error messages and
run RBSU remotely through a serial connection to the server COM port. The remote server does not
require a keyboard or mouse.
For more information about BIOS Serial Console, see the BIOS Serial Console User Guide on the
Documentation CD or the HP website (http://www.hp.com/support/smartstart/documentation).
Selecting the Enable Remote option without the supported RILOE II or iLO firmware will result in an error:
The setting Enable Remote requires RILOE-II or iLO with firmware version
1.20 or greater (1.41 or greater with iLO firmware recommended). Do not
use the Enable Remote setting if iLO is Disabled and RILOE-II is not
installed.
RBSU menu (HP ProLiant G5 and earlier servers or server blades) 100
BIOS Serial Console Baud Rate
The BIOS Serial Console Baud Rate option enables baud rate changes.
EMS Console
The EMS Console option is a Microsoft® Windows Server® 2003 feature that allows for emergency
management console to be redirected through the serial port. When using iLO, select the value (COM 1
or COM 2) assigned to the Virtual Serial Port (on page 85). When redirecting EMS through a physical
serial port, select the value assigned to the Embedded Serial Port ("Embedded Serial Port A" on page
84). The EMS Console feature is disabled by default.
RBSU menu (HP ProLiant G5 and earlier servers or server blades) 101
BIOS Interface Mode
When Auto mode is selected, CLI mode is automatically selected for this POST if the keyboard buffer is
receiving characters from the serial port instead of the keyboard. When Command-Line mode is selected,
CLI mode is automatically enabled.
• Server Name defines a two-line name identifying the server. A maximum of 14 characters can be
entered on each line.
• Server Asset Tag defines a two-line asset tag to identify the server. A maximum of 16 characters can
be entered on each line.
• Server Primary OS defines a three-line description of the primary OS of the server. A maximum of 14
characters can be entered on each line.
• Other Text defines two lines of additional text describing the server. A maximum of 14 characters
can be entered on each line.
RBSU menu (HP ProLiant G5 and earlier servers or server blades) 102
Set Administrator Info Text
The Set Administrator Info Text option defines reference information for the server administrator.
• Admin Name Text defines a two-line description for the server administrator name. A maximum of
14 characters can be entered on each line.
• Admin Phone Number Text defines two lines of text for the server administrator phone number. A
maximum of 14 characters can be entered on each line.
• Admin Pager Number Text defines two lines of text for the server administrator pager number. A
maximum of 14 characters can be entered on each line.
• Other Text defines two lines of additional text relating to the server administrator. A maximum of 14
characters can be entered on each line.
RBSU menu (HP ProLiant G5 and earlier servers or server blades) 103
Set Service Contact Text
The Set Service Contact Text option defines reference information for the service contact of the server.
• Service Name Text defines a two-line description for the service contact name. A maximum of 14
characters can be entered on each line.
• Service Phone Number Text defines two lines of text for the service contact phone number. A
maximum of 14 characters can be entered on each line.
• Service Pager Number Text defines two lines of text for the service contact pager number. A
maximum of 14 characters can be entered on each line.
• Other Text defines two lines of additional text relating to the service contact. A maximum of 14
characters can be entered on each line.
RBSU menu (HP ProLiant G5 and earlier servers or server blades) 104
• Virtual Install Disk (on page 107)
• Secondary IDE Channel Support (on page 107)
• BIOS Enhanced RAID (on page 108)
• Node Interleaving (on page 108)
• Serial Number (on page 108)
• Product ID (on page 108)
• Drive Write Cache (on page 108)
• SATA Software RAID (on page 108)
• Optional PCI-X Riser Fan Monitoring (on page 108)
• Processor Options (on page 109)
• Power Supply Requirements Override (on page 110)
• Embedded VGA Control (on page 110)
IMPORTANT: Menu options may differ from those in this document, depending on specific
server options.
IMPORTANT: This setting is pre-selected. You can override the default setting at this menu, but
successful OS operation is dependent upon the correct (default) setting.
RBSU menu (HP ProLiant G5 and earlier servers or server blades) 105
ROM Selection
The ROM Selection option toggles the server ROM between the current ROM and the backup ROM. All
servers with redundant ROMs allow you to switch to the backup ROM.
RBSU menu (HP ProLiant G5 and earlier servers or server blades) 106
User Default Options
User Default Options enable definition of default configuration settings. When the system is configured
with default settings and saved, the new default settings override factory defaults.
WARNING: When enabled, pressing the NMI Debug Button on the system board during
normal OS operation generates a Blue-Screen Trap, ABEND, or Panic, and halts the system.
RBSU menu (HP ProLiant G5 and earlier servers or server blades) 107
BIOS Enhanced RAID
The BIOS Enhanced RAID feature is a toggle setting that, when enabled, analyzes the Linux data on
installed hard drives for failure information. Based on the analysis, the system ROM automatically chooses
which hard drive to boot.
Node Interleaving
The Node Interleaving feature requires all nodes to have equal memory sizes when enabled. Enabling
Node Interleaving may affect OS performance.
Serial Number
The Serial Number option allows you to change the serial number. HP recommends that you do not
change this number, unless you are replacing a system board. When the Serial Number option is chosen,
a warning displays:
The serial number should ONLY be modified by qualified service
personnel. This value should always match the serial number located on
the chassis.
Product ID
The Product ID option sets the system product ID, which is found on the product ID sticker on the chassis.
When the Product ID option is chosen, a warning displays:
The Product ID should ONLY be modified by qualified service personnel.
This value should always match the Product ID located on the chassis.
RBSU menu (HP ProLiant G5 and earlier servers or server blades) 108
Processor Options
The Processor Options menu includes submenu options for processor settings:
• Processor Hyper-Threading (on page 109)
• HW Prefetcher (on page 109)
• Adjacent Sector Prefetch (on page 109)
• No-Execute Memory Protection (on page 109)
• Intel® Virtualization Technology (on page 109)
• Expansion Card Caching Optimization (on page 109)
Processor Hyper-Threading
The Processor Hyper-Threading option is a toggle setting that allows Intel® Hyper-Threading Technology
to be enabled or disabled, though it is enabled by default. Processor Hyper-Threading delivers two logical
processors that can execute multiple tasks simultaneously using shared hardware resources of a single
processor. The option is supported through the system BIOS. For more information on Processor Hyper-
Threading, refer to the HP website (http://h18004.www1.hp.com/products/servers/technology/hyper-
threading.html).
HW Prefetcher
The HW Prefetcher option allows processor prefetch features to be disabled. In most cases, the option
should remain enabled. The option should be disabled only after performing application benchmarking to
verify improved performance in a particular environment.
RBSU menu (HP ProLiant G5 and earlier servers or server blades) 109
Power Supply Requirements Override
The Power Supply Requirements Override setting enables the system to boot and operate when installed
power supplies do not meet system requirements.
CAUTION: When Power Supply Requirements Override is enabled, some configurations may
not operate properly. Before enabling this option, verify and understand the system power
requirements.
IMPORTANT: The Embedded VGA Control option does not work with all video adapters.
The Embedded VGA Control option, set to Auto Detect by default, disables the embedded video
controller when an optional video controller is installed on the server.
When Always Enabled is selected, the system ROM enables the embedded video controller as the
primary video controller. This option provides dual-head support from both the embedded and optional
video controllers.
RBSU menu (HP ProLiant G5 and earlier servers or server blades) 110
For more information on feature support and how to enable functionality, see the operating system and
video driver documentation.
Utility Language
The Utility Language menu enables you to set the display language for RBSU.
RBSU menu (HP ProLiant G5 and earlier servers or server blades) 111
ROM-based enhancements
The System Maintenance menu is a new utility that replaces the legacy system-partition functionality
supported on some ProLiant servers. This utility is embedded in the system ROM and provides access to
server diagnostics, RBSU, and the Inspect Utility.
To access the System Maintenance menu, press the F10 key when prompted from the boot option ("Boot
options" on page 117) screen.
From the System Maintenance menu, you can select from the following utilities that are embedded in the
system ROM:
Setup Utility
Select Setup Utility from the System Maintenance menu to run the Setup Utility. Running Setup Utility exits
the System Maintenance menu and runs RBSU.
Diagnostics Utility
The Diagnostics Utility is embedded in the system ROM, and provides a pre-boot method for quickly
checking the validity of the three major subsystems of the server needed to boot an operating system. A
complete server diagnostics is available on the SmartStart CD.
All three of these tests should pass if a bootable operating system is installed on the server.
If any test fails, there may be a problem booting the server. To run the Diagnostics Utility, select
Diagnostics Utility from the System Maintenance menu.
• Quick MEMBIST Test — Choosing this option causes the system to reboot and run the preconfigured
hardware-based memory test. Upon reboot, Memory Diagnostics displays the test results. A normal
system reboot is required after performing a MEMBIST test.
• User-defined MEMBIST Test — Choosing this option enables a user-defined configuration of the
Quick MEMBIST test. Increasing the MEMBIST test time results in a blank screen for the duration of
the test. Upon test completion and reboot, Memory Diagnostics displays the test results. A normal
system reboot is required after performing a MEMBIST test.
NOTE: To cancel either MEMBIST test, press and hold the Power On/Standby button to initiate
a forced shut-down. Upon reboot, no record of an incomplete test exists.
For all servers other than a Generation 5 server with an Intel® processor, the Software Memory Test
automatically runs when Memory Test is selected from the Diagnostic Utility Menu.
Auto-Configuration Process
The auto-configuration process automatically runs when you boot the server for the first time. During the
power-up sequence, in many cases the system ROM automatically configures the entire system without
needing any intervention. During this process, the ORCA Utility, in most cases, automatically configures
the array with a default setting based on the number of drives connected to the server.
NOTE: If the boot drive contains logical volumes, or if more than six drives are installed on the
system, ORCA does not automatically configure the array. If this occurs, you must run ORCA to
configure the array settings.
By default, the auto-configuration process configures the system for a default operating system. To change
any default settings in the auto-configuration process, such as the settings for language, operating system,
and primary boot controller, execute RBSU by pressing the F9 key after system POST. After the settings
are selected according to your preference, exit RBSU and reboot the server.
Boot options
Near the end of the boot process, the boot options screen is displayed. This screen is visible for several
seconds before the system attempts to boot from a supported boot device. During this time, you can do
the following:
• Access RBSU by pressing the F9 key.
• Access the System Maintenance Menu (which enables you to launch ROM-based Diagnostics or
Inspect) by pressing the F10 key.
• Force a PXE Network boot by pressing the F12 key.
NOTE: Manual Path Flow is not necessary for servers with Embedded Server Setup.
RBSU can be used to configure an HP server without the use of SmartStart. When the server is powered
up in an unconfigured state, RBSU executes when the F9 key is pressed, allowing the server to be
configured. After the server has been configured using RBSU:
1. Restart or power up the server.
2. Press the F8 key to execute ORCA.
3. After the primary array controller has been configured with ORCA, restart the server.
4. Install the operating system ("Operating System Installation" on page 117). Install any necessary
applications as well.
ACR
Array Configuration Replication Utility
ASR
Automatic Server Recovery
BIOS
Basic Input/Output System
CLI
Command Line Interface
CONREP
Configuration Replication utility
ECC
error checking and correcting
ECP
Extended Capabilities Port Mode
EMS
Emergency Management Services
EPP
Enhanced Parallel Port Mode
IDE
integrated device electronics
iLO
Integrated Lights-Out
iLO 2
Integrated Lights-Out 2
IPL
initial program load
IRQ
interrupt request
LPT
Local port
MEMBIST
Memory Built-in Self Test
MPS
multi-processor specification
NIC
network interface controller
NMI
non-maskable interrupt
NUMA
Non-Uniform Memory Architecture
NVRAM
non-volatile memory
ORCA
Option ROM Configuration for Arrays
PCI
peripheral component interface
PCI-X
peripheral component interconnect extended
PCIe
peripheral component interconnect express
PXE
Preboot Execution Environment
RAID
redundant array of inexpensive (or independent) disks
RBSU
ROM-Based Setup Utility
RTC
real-time clock
SPP
Standard Parallel Port Mode
TPM
trusted platform module
VGA
video graphics array
VSP
virtual serial port
Index 131
N removable flash media boot sequence 17
Restore Default System Settings 78, 106
Network Server Mode option 99 Restore Settings/Erase Boot Disk 79, 106
NMI Debug Button option 63, 107 ROM Selection option 63, 106
Node Interleaving 108 ROM-based enhancements 112
No-Execute Memory Protection 17, 109
NUMLOCK Power-On State option 24, 86
S
O SATA software RAID 108
Scripted Installation Flow 125
operating system installation 117 Secondary IDE channel support 107
Option ROM Loading Sequence 61 Secondary IDE Channel Support option 107
Optional LPT Mode Support 86 Serial Number option 69, 108
Optional LPT Port 86 serial port 1 11
OS Installation 117 Serial port options 10
Server Asset Text 56, 102
P Server Asset Text menu 60, 104
PCI (peripheral component interface) 129 Server Availability 38, 94
PCI Bus Padding Options 65 Server Passwords menu 96
PCI Device Enable/Disable 34 server security 46
PCI Devices option 34, 92 Service Options 69
PCI Express Generation 2.0 Support 32 Set Admin Password option 48, 97
PCI IRQ Settings 34 Set Administrator Info Text option 58, 103
PCI-express Generation 2.0 32 Set Power-On Password option 47, 97
PCI-X riser fan monitoring 108 Set Server Info Text option 57, 102
peripheral component interface (PCI) 129 Set Service Contact Text option 59, 104
POST F1 prompt 42, 95 Setup Utility 113
POST speed up 95 Standard Boot Order (IPL) option 36, 93
power button 44, 96 System Default Options 77
power button option 44 System Maintenance CLI Commands 123
Power Management Option menu 24 System Options menu 10, 83
power regulator 89
Power Supply Requirements Override 110 T
Power-On Delay 45, 96 Thermal Configuration 68
Power-On Logo 67 Thermal Shutdown option 41, 95
Processor Hyper-Threading 20, 109 TPM (Trusted Platform Module) 48, 97
Processor Options 17, 109 TPM Clear 48, 51, 99
Product ID 70, 108 TPM Expansion ROM Measuring 48, 51, 99
TPM Functionality 48, 49, 98
Q TPM Visibility 48, 49, 98
QuickLock option 99 Trusted Platform Module (TPM) 97
Turbo Mode 21
R
U
RBSU CLI Commands 120
RBSU Configuration Flow 124 Ultra Low Power State 91
RBSU Erase Option 113 USB 2.0 EHCI Controller 16, 89
RBSU menu 9, 82 USB Control 14, 88
RBSU overview 7 USB External Port Capability 90
RBSU, running 7 USB Options 14
Redundant Power Supply Mode 27 User Default Options 80, 107
Index 132
Utility Language 81, 111
V
Video Options 68
Virtual Install Disk 64, 107, 113
virtual serial port 12, 85
W
Wake-On LAN (WOL) 41, 95
Wake-on LAN option 41, 95
Index 133