en Chapter Vegaflex
en Chapter Vegaflex
en Chapter Vegaflex
Area of application
The GWR sensors of the VEGAFLEX series are suitable for level m
easurement
in liquids and bulk solids. In liquids, they can also detect the interface
between two products. They measure liquids reliably, even under high
pressure and extreme temperatures. They can be used in simple as well as
in aggressive liquids and are suitable for applications with stringent hygiene
requirements. The sensors can also be used to measure light and heavy bulk
solids with absolute reliability, even in the presence of dust and noise, and
without being affected by buildup or condensation.
Measuring principle
High-frequency radar pulses are coupled onto a cable (bulk solids) or rod
(liquids) and guided along the probe. The pulse is reflected by the product
surface. The instrument calculates the level from the running time of the radar
pulses and the entered tank height.
Advantages
GWR sensors operate independently of noise, pressure or temperature
fluctuations and are also completely unaffected by changes in density,
foaming, steam or dust. Buildup on the probe or on the container wall does
not affect the measurement either. This allows simple, straightforward system
design and engineering. The menu-driven adjustment routines enable simple,
time-saving and confident setup.
14
VEGAFLEX 81 VEGAFLEX 82
Application All kind of liquids, applications with steam, Light-weight and heavy-weight bulk solids
buildup, foam generation, condensation as of all kind, applications with strong
well as ammonia dust generation, condensation or buildup
Measuring range Cable probe up to 75 m of 316 Cable probe up to 75 m of 316 or
Rod probe up to 6 m of 316L or Alloy C22 316 PA coated
Coax probe up to 6 m of 316L or Rod probe up to 6 m of 316L
Alloy C22
Signal output 4 ... 20 mA/HART, Profibus PA, 4 ... 20 mA/HART, Profibus PA,
Foundation Fieldbus Foundation Fieldbus
Approvals ATEX, IEC, FM, CSA, EAC (GOST), UKR Sepro, ATEX, IEC, FM, CSA, EAC (GOST), UKR Sepro,
Overfill protection, Ship, SIL2, FDA Overfill protection, Ship, SIL2
15
Level l Guided Wave Radar
VEGAFLEX 83 VEGAFLEX 86
Application Aggressive liquids or liquid media with stringent Virtually all liquids under extreme pressure
hygienic requirements, applications with steam, and temperature conditions, applications with
buildup, foam generation or condensation buildup, foam generation or condensation
Measuring range Cable probe up to 32 m of PFA Cable probe up to 75 m of 316 or Alloy C22
Rod probe up to 4 m of PFA or Rod probe up to 6 m of 316L or Alloy C22
1.4435 (BN) Coax probe up to 6 m of 316L or Alloy C22
Process fitting Flanges from DN 25, 1", hygienic fittings, Thread from G¾, ¾ NPT,
clamp, slotted nut flanges from DN 25, 1"
Signal output 4 ... 20 mA/HART, Profibus PA, 4 ... 20 mA/HART, Profibus PA,
Foundation Fieldbus Foundation Fieldbus
Approvals ATEX, IEC, FM, CSA, EAC (GOST), UKR Sepro, ATEX, IEC, FM, CSA, EAC (GOST), UKR Sepro,
Overfill protection, Ship, SIL2, EHEDG/3A, FDA steam boiler, Overfill protection, Ship, SIL2
Benefit ▪▪ Gap-free hygienic design ensures good ▪▪ Comprehensive diagnostic options guarantee
cleanability with simple methods low-maintenance operation and thus high
▪▪ Maintenance-free operation increases plant availability
profitability of the plant ▪▪ Shortenable probes enable simple
standardization and maximum flexibility
in planning
16
VEGAPASS 81
17