Rockassist (EN ISO 12241) Online Thermal Calculation Tool: License Holder
Rockassist (EN ISO 12241) Online Thermal Calculation Tool: License Holder
LICENSE HOLDER
Company Name INCA S.A.
Contact Brian Stevenson
Mobile
E-Mail [email protected]
Date 1/21/2019 12:25:21 PM
Page 1/3
PROJECT / CUSTOMER NOTES
Project Name Planta de Yodo
Contact INCA S.A.
Tel. +56228995400
E-Mail [email protected]
DESIGN CONDITIONS
TYPE OF CALCULATION ACCORDING TO EN ISO 12241 AMBIENT CONDITIONS
Quick Check: heat loss (q), T and CO2 savings Ambient Temperature
- Personal protection 25.0 °C
OBJECT - Heat loss, freezing, cooling -10.0 °C
Object type Pipe Windspeed
Orientation Horizontal - Personal protection 0.00 m/s
Diameter DN 80 - NPS 3 - Heat loss, freezing, cooling 10.00 m/s
Outer pipe diameter 88.9 mm
Pipe length 1,000 m INSULATION SYSTEM
Wall Thickness 3.2 mm Cladding Aluminium bright-rolled
Operating temperature 225.0 °C Emissivity of cladding 0.05 -
Support Constructions Without support
ECONOMIC DESIGN CONDITIONS
constructions
Energy Costs 0.10 €/kWh
Delta lambda per support construction 0.000 W/mK
Annual operation time 8,760 h/a
Insulation fixings None
Lifetime of insulation 1 a
Delta lambda per pin 0 W/mK
Plant related thermal bridges No
ECOLOGIC DESIGN CONDITIONS
Fuel type Black coal -
CO2-Factor 94.5 kgCO2/GJ
RESULTS (FOR CHOSEN THICKNESS ONLY - MORE RESULTS ON THE NEXT PAGE)
Surface temp. at 25 °C Heat loss at -10.0 °C ambient
Insulation Annual savings compared to
ambient temp. and 0.00 m/s temperature and 10.00 m/s
thickness uninsulated situation
windspeed windspeed
mm °C W/m W/m² t_CO2/a Heat loss costs
€/a
50 52.1 91.8 154.7 19,136 5,624,872
s - Insulation thickness, Lambda – Opertional thermal conductivity, theta_si – Operating temperature, theta_sa – Boundary layer temperature, F_comp – Compression of
insulation, F_conv – Effect of convection, F_j – Effect of gaps (between the insulation), F_a – Ageing of insulation, F_d – Effect of radiation, F – sum of all factors
Rockassist is an expert calculation tool of ROCKWOOL Technical Insulation
www.rockwool-rti.com
Rockassist (EN ISO 12241)
Online Thermal Calculation Tool
LICENSE HOLDER
Company Name INCA S.A.
Contact Brian Stevenson
Mobile
E-Mail [email protected]
Date 1/21/2019 12:25:21 PM
Page 2/3
PROJECT / CUSTOMER NOTES
Project Name Planta de Yodo
Contact INCA S.A.
Tel. +56228995400
E-Mail [email protected]
Surface Temperature
Heat loss
Rockassist is an expert calculation tool of ROCKWOOL Technical Insulation
www.rockwool-rti.com
Rockassist (EN ISO 12241)
Online Thermal Calculation Tool
LICENSE HOLDER
Company Name INCA S.A.
Contact Brian Stevenson
Mobile
E-Mail [email protected]
Date 1/21/2019 12:25:21 PM
Page 3/3
PROJECT / CUSTOMER NOTES
Project Name Planta de Yodo
Contact INCA S.A.
Tel. +56228995400
E-Mail [email protected]
Insulation Surface
Heat loss (q) Heat loss Convection
thickness Temperature
mm W/m² W/m °C -
0 23,319.7 6,512.9 225.0 laminar
25 353.2 154.1 71.4 laminar
30 285.7 133.6 65.5 laminar
40 202.9 107.7 57.4 laminar
50 154.7 91.8 52.1 laminar
60 123.6 81.1 48.3 laminar
70 101.9 73.3 45.4 laminar
80 86.2 67.4 43.2 laminar
90 74.2 62.7 41.5 laminar
100 64.9 58.9 40.0 laminar
110 57.4 55.7 38.8 laminar
120 51.4 53.1 37.8 laminar
130 46.3 50.8 37.0 laminar
140 42.1 48.8 36.2 laminar
150 38.5 47.1 35.5 laminar
160 35.4 45.5 35.0 laminar
170 32.8 44.2 34.4 laminar
180 30.4 42.9 34.0 laminar
190 28.4 41.8 33.6 laminar
200 26.5 40.8 33.2 laminar
210 24.9 39.8 32.8 laminar
220 23.5 39.0 32.5 laminar
230 22.1 38.2 32.2 laminar
240 21.0 37.4 31.9 laminar
250 19.9 36.8 31.7 laminar
260 18.9 36.1 31.5 laminar
270 18.0 35.5 31.3 laminar
280 17.2 35.0 31.1 laminar
290 16.4 34.4 30.9 laminar
300 15.7 34.0 30.7 laminar
310 15.0 33.5 30.5 laminar
320 14.4 33.0 30.4 laminar
330 13.9 32.6 30.2 laminar
340 13.3 32.2 30.1 laminar
350 12.9 31.8 30.0 laminar
360 12.4 31.5 29.8 laminar
370 12.0 31.1 29.7 laminar
380 11.6 30.8 29.6 laminar
390 11.2 30.5 29.5 laminar
400 10.8 30.2 29.4 laminar
The convection type (laminar, turbulent or transitional) in the last column of the table is an indication for the wind situation near the surface of the cladding. It can be
possible that increasing the thickness of insulation can cause a change from laminar to turbulent convection. This can be a reason for increasing surface temperature
even if the insulation thickness is bigger than in the step before.
DISCLAIMER
Rockassist has been assembled with the greatest possible care by ROCKWOOL Technical Insulation. All calculations are carried out in conformance with Guideline EN
ISO 12241, dated 2008, and the latest ROCKWOOL product specifications. The user of this program accepts the following conditions. The user is exclusively responsible
for the correctness of the input of data into this calculation program. The user is aware that theoretical values can deviate from those occurring in practice. Especially
surface temperatures are very susceptible for external influences such as wind, draught, etc. ROCKWOOL Technical Insulation does not warrant the correctness of (the
outcome of) any calculation and shall not be liable for any direct, indirect or consequential damages or any other damages whatsoever incurred by the user or third party
resulting from the use of this calculation program or loss of data. ROCKWOOL Technical Insulation reserves all rights (including copyright and other intellectual property
rights) in respect of all information offered through this calculation program, including the software, the product name Rockassist and specifications.
Rockassist is an expert calculation tool of ROCKWOOL Technical Insulation
www.rockwool-rti.com