Features Description
Double helical coil design The TLR series sample cooler is the most efficient
Minimize cooling water needs and cost effective sample cooler available. Optimal
service for flows below 1800 cc/min for single phase
Wide variety of exotic alloys for corrosion and below 1000 cc/min for condensing heat transfer.
resistance Standard tube side materials are 316/316L SS and
Retained shellside gasket reduces Alloy (Inconel®) 625. Optimized for steam condensing
re-assembly time service.
Formed shell allows more flexibility in shell
materials
incremento de
Mounting bracket cantemperatura
be installed without
na perda de carga da
removing flange bolts
amostra em amostra
relação a
Performance Curve -da
tempertura Water Performance Curve - Steam
água
Model de
TLR-4225 Model TLR-4225
2 2 Surface Area 2.4 Ft.2 [0.22 m2]
Surface Area 2.4 Ft. [0.22 m ]
7 GPM [26.5 L/min] Cooling Water at 95oF [35oC]
resfriamento
5 GPM [18.9 L/min] Cooling Water at 95 F [35 C] o o
)]
9.5 PSI [0.66 Bar] Pressure Drop
bar(a
5 PSI [0.35 Bar] Pressure Drop
[34.5 SIA
50 0
P
500
30
Due to two-phase flow variability, please consult factory for pressure drop.
25
re
15
ssu
Sa 10
m
40
t Pr e
pl
e
Pr
es
)]
Inle
su
r(a
Approach Temperature (oC)
Approach Temperature (oF)
20 re
ba
am
Approach Temperature (oC)
Approach Temperature (oF)
Dr
op 20
Pressure Drop (PSI)
.9
d Ste
[68
(P 20
SI
1 PSI = 0.069 Bar
30 )
SI A
]
rate
( a)
10
C)
ar
P
15
1o
Satu
4b
00
)]
37
10
r(a
.
30
03
F(
ba
[1
0o
]
a)
72 7.9
A
r(
70
)]
P S PS P S I
ba
r(a
)
[1 [13
C
16 o
20 ba
.4
00 00 00
IA IA
.7
(3
10
15
13
F
0o
40 [2
60
IA
2 5 20
10 PS
5 00
o C) 31
0
10 (2 6 o )
5 o F C
50
0 04
50 o F (2 o C)
0
40 o F (149
300 o
(93 C)
o
200 F o o C)
Inlet Tem p. 150 F (66
0 60
0
400 600 800 1000 1200 1400 1600 1800 2000
CCM 400 600 800 1000 1200
CCM
0.1 0.2 0.3 0.4 0.5
GPM 0.1 0.2 0.3
GPM
60 80 100 120 140 160 180 200 220 240 260 280
Lbm/Hr 40 50 60 70 80 90 100 110 120 130 140 150 160 170
Flow Rate Lbm/Hr
Flow Rate
MOUNTING BRACKET
(SUPPLIED WITH EACH COOLER)
3/4 in. FNPT
cooling water inlet
TLR-4225 450 psi @ 650ºF 5000 psi @ 1000ºF 316/316L SS 304 SS 2.4 ft2 17 lbs 7-03951A
31 bar @ 343ºC 345 bar @ 538ºC 1/4" O.D. x 0.049" AW 0.22 m2 8 kg
TLR-4225U 450 psi @ 650ºF 4400 psi @ 1000ºF 316/316L SS 304 SS 2.4 ft2 17 lbs 7-03951B
31 bar @ 343ºC 303 bar @ 538ºC 1/4" O.D. x 0.049" AW 0.22 m2 8 kg
TLR-42B5 450 psi @ 650ºF 5000 psi @ 1100ºF Alloy (Inconel®) 625 304 SS 2.4 ft2 17 lbs 7-03951C
31 bar @ 343ºC 345 bar @ 593ºC 1/4 " O.D. x 0.035" AW 0.22 m2 8 kg
TLR-42B5U 450 psi @ 650ºF 5000 psi @ 1100ºF Alloy (Inconel®) 625 304 SS 2.4 ft2 17 lbs 7-03951D
31 bar @ 343ºC 345 bar @ 593ºC 1/4" O.D. x 0.035" AW 0.22 m2 8 kg
TLR-4BB5 450 psi @ 650ºF 5000 psi @ 1100ºF Alloy (Inconel®) 625 Alloy 2.4 ft2 17 lbs 7-03951E
31 bar @ 343ºC 345 bar @ 593ºC 1/4" O.D. x 0.035" AW (Inconel®) 625 0.22 m2 8 kg
NOTES:
• U in model number denotes ASME stamped model.
• Canadian Registration Number available for ASME stamped models only. Consult factory for CRN and other options and information.
• Vessels are exempt from CE marking per PED 97/23/EC, TÜV. Vessels are below or equal to the limits set forth in Article 3, Sections 1.1, 1.2, 1.3 and Section 2 as
applicable, and are designed and manufactured in accordance with sound engineering practice (meets the general requirements of the ASME Section VIII, Division
1, Boiler And Pressure Vessel Code). Nameplate will bear the name of Sentry Equipment Corp and safety instructions will be included per Article 3, Section 2.
It is solely the responsibility of the end-user, through its own analysis and testing, to select products and materials suitable for their specific application
requirements, ensure they are properly installed, safely applied, properly maintained, and limit their use to their intended purpose. Improper selection,
installation, or use may result in personal injury or property damage.