0% found this document useful (0 votes)
369 views2 pages

Ethiopian Construction Design & Supervision Works Corporation

The document summarizes the results of a modified compaction test conducted on a soil sample from project location Addis Ababa. The test was conducted to determine the maximum dry density (MDD) of 1.880 g/cm3 and optimum moisture content (OMC) of 16.75% for the soil. It includes the trial results showing weights and densities at different moisture contents, and a graph plotting the dry density against moisture content with an MDD of 1.890 g/cm3. The test was conducted by the laboratory expert and checked by the senior geotechnical engineer.

Uploaded by

BikaZee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
369 views2 pages

Ethiopian Construction Design & Supervision Works Corporation

The document summarizes the results of a modified compaction test conducted on a soil sample from project location Addis Ababa. The test was conducted to determine the maximum dry density (MDD) of 1.880 g/cm3 and optimum moisture content (OMC) of 16.75% for the soil. It includes the trial results showing weights and densities at different moisture contents, and a graph plotting the dry density against moisture content with an MDD of 1.890 g/cm3. The test was conducted by the laboratory expert and checked by the senior geotechnical engineer.

Uploaded by

BikaZee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

ETHIOPIAN CONSTRUCTION DESIGN & SUPERVISION WORKS CORPORATION

Research, Laboratory and Training Center


Laboratory Testing Process
Tel 0116 - 61 45 01 / 0116 - 61 01 05 ; Fax. 251 - 116 - 61 53 71/61 08 98; e-mail [email protected] ; P.O.Box 2561

Geotechnical Laboratory Sub-Process

Project :- Producing Ecofriendly Construction Materials


Client :- Addis Ababa Science & Technology University
Location :- Addis Ababa
BH / TP :- PZ-50SA Lab No. : 877/11
Depth :- - Test Type Modifide Compaction
Sample type Disturbed
MDD (g/cm3) 1.880
OMC (%) 16.75

Trial 1 Trial 2 Trial 3 Trial 4 Trial 5


Water in cc - - - - -
Wt.of mould + Wet sample(g) 10375.5 10728.4 11129.3 10931.5 -
Wt.of mould (g) 6440.2 6440.2 6440.2 6440.2 -
Wt.of wet soil(g) 3935.3 4288.2 4689.1 4491.3 -
Volume of mould cm3 2124 2124 2124 2124 -
Wet Density gm /cm3 1.853 2.019 2.208 2.115 -
Moisture content
Wet soil + tin (g) 159 189.7 139.4 153.4 -
Dry soil + tin (g) 149.3 171.6 120.9 125.1 -
Wt of tin (g) 16.2 16.3 16.5 16.1 -
Wt of Water (g) 9.70 18.10 18.50 28.30 -
Wt of Dry soil (g) 133.1 155.3 104.4 109 -
Moisture content % 7.29 11.65 17.72 25.96 -
Dry Density gm /cm3 1.727 1.808 1.875 1.679 -
Dry Density gm/cc

1.890

1.870

1.850

1.830

1.810

1.790

1.770

1.750

1.730

1.710

1.690

1.670

1.650
6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
Water Content %

Tested by :- Checked by :-
Lab Expert Senior Geotechnical Engineer

Processed by :- Approved by :-
Geotechnical Engineer Geotechnical Lab S/P Manager

You might also like