0% found this document useful (0 votes)
59 views1 page

4.1 Structure: 4.0 Engineering Strategy

notes 2

Uploaded by

Mohammed Ashraf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views1 page

4.1 Structure: 4.0 Engineering Strategy

notes 2

Uploaded by

Mohammed Ashraf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

4.

0 Engineering Strategy

4.1 Structure
Notes:
Do not scale from drawings. All discrepancies to be reported to
Gensler architect immediately.
All dimensions to be verified by contractor on site prior to any works

A Aa B Ba Bb C Ca Cb Cc Cd D E F G H Client

1200 3550 1150 1200 6350 1150 1200 4700 1200450 8700 8700 8700 800

(400x750)
(400x600)
(250x1100)

(250x1100)

(400x750)

(400x600)
(250x1100) WASL
P.O.Box 23073

250
Dubai , UAE

250
(250x1100)
Tel +971 (0)4 511 6302

2900
Lead Consultant

(250x1100)

2500
C12 (700 x 3200) PD1-XX-22021
5.1
(500x1100) (500x550)
C05 (600x1500) C05 (600x1500) C05 (600x1500)
1200

500
500
C11 (600x4900) Etihad towers T3, 32nd Floor
6 Corniche Street West PO Box 26967

(250x1100)
Abu Dhabi,
1PD1-XX-2201 United Arab Emirates

3000
3000
Tel +971 (0)2 696 3400

(400x600)

(400x750)
Fax +971 (0)2 635 9186
(500x550)

(400x600)

(400x750)
500
500
T=260 Consultant
T=200
7200

RC SLAB

(500x550)

(500x550)
RC SLAB SSL -7.475

1900
SSL -7.475
T=260
(500x550)
RC SLAB

500
500
SSL -7.475

(250x1100)

(250x1100)
C12 (700 x 3200) C11 (600x4900)

(400x750)
C05 (600x1500)
6.1
1500

DN C05 (600x1500) C05 (600x1500)

(400x750)
GLEEDS
7

(250x1100)

(250x1100)
P.O.Box 23073
Dubai , UAE

8100
8100

Tel +971 (04) 321 4435

(400x750)
6300

(250x1100)

(250x1100)
DESIGN WORKSHOP
Dubai , UAE
Tel +971 (04) 455 8555
650
(500x550)

500
250 800 500

C07 (600x3200) C07 (600x3200)


(400x600)
7.1
No slab required due to GENIUS LOCI

3850
2400

P.O. Box 336651


(250x1100) (250x1100)

C05 (600x1500) C05 (600x1500) C05 (600x1500) Dubai , UAE

double height water tanks, 8


Tel +971 (0)4 511 6302

spacial requirement
6000

600 1200 250 1500 250


(250x1100)
(250x1100)


PD1-XX-0701

(600x550) (400x600)
6000

600

500 3000 250 2500 250 2400 500


C07 (600x3200) C07 (600x3200)

8.1
A 09/08/2018 Schematic Design PD WH
2700

rev date revision note drawn checked


C05 (600x1500) C05 (600x1500) C05 (600x1500) Key Plan

9
5100

T=260
RC SLAB
SSL -7.475
C07 (600x3200) C10 (600x4000) C10 (600x4000) N

PLOT 1
9.1 Q

Discipline
3600

STRUCTURAL
Drawing Status
C05 (600x1500) C05 (600x1500) C05 (600x1500) C05 (600x1500) C05 (600x1500) FIT FOR COORDINATION
Title
10
4150

PARTIAL GA PLAN - BASEMENT 2 -


C05 (600x1500)
C02 (600x800) C02 (600x800) C02 (600x800) C02 (600x800) C02 (600x800) PART D
650

450

450
C02 (600x800) Project
11 Wasl - Kifaf Phase 5 (Stg 1 & 2)
P. O. Box 23073

Project Number
17.8140.01
Scale Date Drawn Checked
1 : 100 09/08/2018 PD WH
1 PARTIAL GA PLAN - BASEMENT 2 - PART D Drawing Number Rev

A
1 : 100
F1013-DE-MHT-ST-DWG-PD1-B2-1104

© 2018 Gensler All rights reserved, including but not limited to The Copyright, Design and Patents Act
1988

F1013-DE-MHT-ST-DWG-PD1-B2-1104

District Cooling Design Report | F1013-DE-GEN-AR-RPT-XXX-XX-0005 Rev. A | Vol.01 13

You might also like