MF3 FILTER ASSEMBLY SELECTION AND SIZING GUIDELINES
Effective filter sizing requires consideration of flow rate, viscosity (operating and cold start), fluid type and degree of filtration.
When properly sized, bypass during cold start can be avoided/minimized and optimum element efficiency and life achieved. The
filter assembly differential pressure values provided for sizing differ for each media code, and assume 150 SSU (32Cts) viscosity
and 0.86 fluid specific gravity. Use the following steps to identify the correct high pressure filter assembly.
2. Calculate actual clean filter assembly Dp at both operating and cold start viscosity:
Actual assembly clean Dp = Flow rate x Dp Coefficient x Assembly Dp factor (from sizing table)