Verification Verification Example: 1003 – AISC E.1A - W-Shape Column Design with Pinned Ends
Description
An ASTM A992 14×132 W-shape column is loaded with the axial compression forces given. The
column is pinned top and bottom in both axes. Determine whether the column is adequate to
support the loading shown in Figure 1 based on LRFD and ASD, see [1].
Yield
Fy 50.000 ksi
Strength
PD + PL
L x
y
z
Taking into account self-weight, determine the available strength in axial compression of the
column according to [1].
AISC Solution
From ASCE/SEI 7, Chapter 2, the required compressive strength is
LRFD ASD
Pu = 1.2 ⋅ 140 + 1.6 ⋅ 420 = 840.000 kips Pa = 140 + 420 = 560.000 kips
Kx = Ky = 1
1003 – 1
Verification Example: 1003 – AISC E.1A - W-Shape Column Design with Pinned Ends
Because the unbraced length is the same in both the x–x and y–y directions and rx exceeds ry for
all W-shapes, y–y axis bucking will govern.
Enter AISC Manual Table 4-1a with an effective length Lc = 30.000 ft, and proceed across the
table until reaching the least weight shape with an available strength that equals or exceeds the
required strength.
From AISC Manual Table 4-1a, the available strength for a y–y axis effective length of 30.000 ft is
LRFD ASD
RFEM 5 Settings
Results
1003 – 2
Verification Example: 1003 – AISC E.1A - W-Shape Column Design with Pinned Ends
Available Strength
1003 – 3
Verification Example: 1003 – AISC E.1A - W-Shape Column Design with Pinned Ends
1003 – 4
Verification Example: 1003 – AISC E.1A - W-Shape Column Design with Pinned Ends
1003 – 5
Verification Example: 1003 – AISC E.1A - W-Shape Column Design with Pinned Ends
References
[1] AMERICAN INSTITUTE OF STEEL CONSTRUCTION, Specification for Structural Steel Buildings.
2015.
1003 – 6