General Information: Location A Location B
General Information: Location A Location B
General Information: Location A Location B
General Information
Filename: Fiber39.trc
Test date: 12/7/2018 Customer:
Test time: 1:41:05 PM Company:
Cable ID: Fiber ID: Fiber39
Job ID:
Comments:
Locations
Location A Location B
Location
Operator
Model MAX-710B-M1-EA
Serial number 810502
Calibration date 1/7/2015 (UTC)
Results
Span length: 0.0993 km Average loss: 11.459 dB/km Injection level: 16.1 dB
Span loss: 1.138 dB Average splice loss: 0.342 dB
Span ORL: 16.55 dB Maximum splice loss: 0.342 dB
Graph
Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 36.301 dB/km A-B average loss: 71.794 dB/km
a 0.0600 14.771 A-B LSA loss: 0.042 dB 4-point Event Loss: 8.775 dB
A 0.1200 11.266 A-B ORL: 60.18 dB Maximum reflectance: ---
B 0.1800 6.961
b 0.2210 2.170
Macrobend
Position (km) Delta Loss (dB)
Pass/Fail Thresholds
1310 nm
Splice loss (dB) 0.100
Connector loss (dB) 0.350
Test Parameters
A→B
Wavelength (nm) 1310 (9 μm)
Range (km) 0.3000
Pulse (ns) 50
Duration (s) 10
Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 2.000000
Backscatter (dB) -79.45
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 5.000