Hyundai Elevator Planning Guide
Hyundai Elevator Planning Guide
Hyundai Elevator Planning Guide
Hyundai Elevator Co. Ltd. is the number one company with the
highest market share among Elevator companies in Korea and has
become a major supplier of elevators & escalators in South East Asia, 02-07 Typical Car Designs
India, Middle East, Africa, USA, Japan and Europe.
08-11 Finishing Options
Our Company offers a full line of moving systems meticulous in
12-17 Planning Guide
detail, bringing together some of the most advanced technology and
progressive designs in the industry. 18-24 Glass & Observation Elevators
25-28 Freight & Automobile Elevators
Hyundai’s product range includes, in addition to elevators,
escalators and travellators, parking systems, airport logistics (cargo
and baggage handling) systems, automated warehousing systems
and platform screen doors.
Car Walls MS, Powder Coated (shade selectable) Car Walls SS, Hairline Finish
Car Door MS, Powder Coated (shade selectable) Car Door SS, Hairline Finish
Car Operating Panel & Type OPP-N240A Car Operating Panel & Type OPP -N240A
Indicator (Indicator PI -D601 separately in transom ) Indicator (indicator PI-D601 separately in transom )
Buttons Type A40 - Braille marked, rugged, Buttons Type A40 - Braille marked, rugged,
self illuminated LED number and ring self illuminated LED number and ring
Handrail HR-01A (Tubular, SS) Handrail HR- 01A (Tubular, SS, at rear only)
02 Note: Car is configurable and price will depend on the final configuration. Selectable options subject to availability at the time of finalization. Note: Car is configurable and price will depend on the final configuration. Selectable options subject to availability at the time of finalization. 03
Car Design SP - 04 (SS, Mirror Etched and Hairline Finish) Car Design SP - 05 (SS, Mirror and Mirror Etched Finish)
Side panels of each wall: SS, Hairline Finish Side panels of each wall: SS, Mirror Finish
Car Walls Car Walls
Middle panels of each wall: SS, Mirror Etched Middle panels of each wall: SS, Mirror Etched
Car Door SS, Mirror Etched Car Door SS, Mirror Etched
Car Operating Panel & Type OPP-N240A Car Operating Panel & Type OPP-D240B
Indicator (Indicator PI -D601 separately in transom ) Indicator (indicator integral in car operating panel )
Type A40 - Braille marked, rugged, Type A40 – Braille marked, rugged,
Buttons Buttons
self illuminated LED number and ring self illuminated LED number and ring
Curved acrylic, type C-726A (frame options Flat acrylic, type CD289C
False Ceiling False Ceiling (frame options SS Hairline/ Mirror Finish)
MS Powder Coated and SS Hairline/ Mirror Finish)
Colored acrylic (standard grey acrylic Colo red acrylic (standard grey acrylic or recess
Flooring Flooring for flooring by others)
or recess for flooring by others)
Handrail HR-Bar (Flat Bar, SS - at rear only, not shown ) Handrail HR-01B (Tubular, SS, with PVC sleeve )
04 Note: Car is configurable and price will depend on the final configuration. Selectable options subject to availability at the time of finalization. Note: Car is configurable and price will depend on the final configuration. Selectable options subject to availability at the time of finalization. 05
Car Design SP - 07 (SS, Mirror Etched and Hairline Finish) Landing Door Jamb Options
Narrow Jamb
(Jamb Type: JP-050)
06 Note: Car is configurable and price will depend on the final configuration. Selectable options subject to availability at the time of finalization. Note: Price will change with change in jamb type from default.
Special hairline etching finish doors shown above are illustrative and available as optional extras.
07
False Ceiling Options Indicator and Button Panels and Hall Lanterns
Type: C245AS (Acrylic in Steel Frame) Type: C421A (Acrylic in Steel Frame)
Steel frame options: Steel frame options:
OPP-N240W
MS, powder coated finish SS, hairline finish MS, powder coated finish SS, hairline finish (Handicapped Type;
A40 Buttons; Indicator Separate)
SS, mirror finish SS, mirror finish
Note: Note:
Available for capacity up to 15-persons Available for capacity up to 15-persons
(similar flat ceiling available for 13 to 24-persons capacity)
Indicator PI-D601
OPP-D241B OPP-D221B OPP-D240B OPP-N240A (Indicator in Car Transom with
(A41 Buttons; (A21 Buttons; (A40 Buttons; (A40 Buttons; Car Operating Panel Types
Integral Indicator) Integral Indicator) Integral Indicator) Indicator Separate) OPP-N240A & OPP-N240W)
Type: C726A (Acrylic in Steel Frame) Type: C806A (Acrylic in Steel Frame)
Steel frame options: Steel frame options:
MS, powder coated finish SS, hairline finish SS, hairline finish
SS, mirror finish SS, mirror finish HIP-D240WA HIP-D442WB
(Box Type) (Boxless)
Note: Note:
Available for capacity up to 15-persons only and not for Available for capacity up to 24-persons
deep car (availability for customized cars subject to fitment) (availability for customized cars subject to fitment)
HIP-D442B HIP-D240A HPB-442B HPB-240
(Hall Indicator & (Hall Indicator & (Hall Button Panel, (Hall Button Panel,
Button Panel, Button Panel, Box-less Type Box Type
Box-less Type Box Type A40 Buttons.) A40 Buttons.)
A40 Buttons.) A40 Buttons.)
Indicator PI-D610
Notes: (Indicator in Landing Transom with
Above hall indicator and hall button panels available with A41 and A21 buttons also. Hall Button Panel Types
HPB-442B & HPB-240)
NOTES:
Some photos above are of etching on SS hairline finish base and some of etching on SS mirror finish base.
Handrail Type HR-01B Any pattern can be etched on hairline or mirror finish base SS.
(SS, Hairline Finish with PVC Sleeve) Above samples can be physically shown at the time of final selection.
The above are some of the etching patterns already available. Any other etching pattern required can be developed at extra price.
Machine Room Type Elevators – Geared Drive Illustrative Hoist-way Layout - Machine Room Type Elevators
Maximum travel 60M at 1.0 MPS and 70M at 1.5 MPS. Plan of Machine Room
( * ) Machine room size shown above is for speed 1.0 MPS. It has to be increased by 500mm in width as well as depth for speed 1.5 MPS.
Machine room height recommended is 2500mm.
Above mentioned overhead is applicable to Hyundai’s standard car height of 2500mm and door height of 2100mm
AND
Section of Hoistway
12 13
Planning Guide Planning Guide
Machine Room Type Elevators – Gearless PMSM Drive Machine Room Less (MRL) Elevators – Gearless PMSM Drive
Standard Size (mm) Hoist-way Standard Size (mm) Hoist-way Top Floor
Machine Room Speed
Capacity Car Door Capacity Car Door Required Front Wall
Speed Required Options
Internal Opening Size (mm) * Internal Opening Thickness
Persons KG M/Sec CW x CD DW HW x HD (mm) *
M/Sec Persons KG CW x CD DW HW x HD MW x MD
1.0 4 272 1.0 900 x 1000 800 (SO) 1500 x 1500 280
8 544 1400 x 1030 800 1800 x 1660 3000 x 3660
1.5 5 340 1.0 1000 x 1100 800 (SO) 1600 x 1500 280
9 612 1400 x 1100 800 1800 x 1730 3000 x 3730
6 408 1.0 1100 x 1150 800 (SO) 1700 x 1550 280
10 680 1400 x 1250 800 1800 x 1880 3000 x 3880 8 544 1.0 1200 x 1250 800 (CO) 1900 x 1650 280
1.0
11 748 1400 x 1350 800 1800 x 2000 3000 x 4000 9 612 1.0 1100 x 1400 800 (CO) 1950 x 1800 280
1.5
1.0 280
1.75 13 884 1600 x 1350 900 2050 x 2000 3250 x 4000
11 748 1.5 1200 x 1575 800 (CO) 2000 x 1975 280
15 1020 1600 x 1500 900 2050 x 2150 3250 x 4150
1.75 280
17 1156 1800 x 1500 1000 2350 x 2280 3550 x 4280 1.0 280
20 1360 1800 x 1700 1000 2350 x 2480 3550 x 4480 15 1020 1.5 1500 x 1600 900 (CO) 2300 x 2000 280
24 1632 2000 x 1750 1100 2550 x 2530 3750 x 4530 1.75 280
1.0 280
13 884 1600 x 1350 900 2300 x 2200 3800 x 4700
17 1156 1.5 1650 x 1650 1000 (CO) 2500 x 2050 280
2.0
15 1020 1600 x 1500 900 2300 x 2350 3800 x 4850 1.75 340
2.5
17 1156 1800 x 1500 1000 2500 x 2350 4000 x 4850 1.0 280
20 1360 1.5 1700 x 1800 1000 (CO) 2600 x 2300 340
20 1360 1800 x 1700 1000 2500 x 2550 4000 x 5050
1.75 340
24 1632 2000 x 1750 1100 2700 x 2600 4200 x 5100
1.0 340
Maximum travel 60M at 1.0 MPS, 70M at 1.5 MPS, 95M at 1.75 MPS and 120M at 2.0 & 2.5 MPS. 24 1632 1.5 1800 x 2000 1100 (CO) 2700 x 2500 340
( * ) Machine room width and depth shown above for speeds' group 1.0, 1.5 & 1.75 MPS are for speeds 1.0 & 1.5 respectively. Machine room 1.75 340
width and depth has to be increased by 500mm respectively for speeds 1.5 & 1.75 MPS (over that shown above for speed 1.0 MPS). Machine
room height recommended is 2500mm.
Maximum travel 60M at 1.0 MPS, 70M at 1.5 MPS and 95M at 1.75 MPS.
( * ) Front wall thickness shown is the minimum required at top floor since control panel is located in top floor front wall, beside the landing
Overhead & Pit Depth Required (mm) door.
14 Above mentioned overhead is applicable to Hyundai’s standard car height of 2500mm and door height of 2100mm Above mentioned overhead is applicable to Hyundai’s standard car height of 2500mm and door height of 2100mm 15
Planning Guide Planning Guide
2. Car and machine room sizes and pit depth and overhead requirements shown are based on IS norms as applied in
India (linked to speed and car height) and may differ from those appearing in some Hyundai catalogues.
3. Car and required hoist-way sizes shown for machine room type elevators are with counter-weight at rear. Motor
as well as counterweight come on a side in the hoist-way in case of MRL elevators.
4. Car size can be customized as long as car internal area to capacity ratio and the differences between car
internal width and hoist-way width and car internal depth and hoist-way depth respectively are maintained.
Car internal width variation is offered in multiples of 100mm.
5. Door opening widths shown are all centre opening in case of machine room type elevators and side opening or
telescopic (SO) or centre opening (CO) as shown in the planning table in case of MRL elevators.
6. Standard car internal sizes shown yield area slightly more than permitted in IS in case of some smaller capacity
MRL elevators. Effective area will be reduced by handrail.
Plan of Hoistway 7. Standard minimum MRL lift capacity is 11 persons at speeds 1.5 and 1.75 MPS. Requirement of a lower capacity
elevator at either of these speeds will entail using the drive and related parts meant for 11 person capacity.
Hoist-way size required will be determined by the differences between car internal width and hoist-way width
for11 person capacity.
8. Capacities in between Hyundai's standard capacities (viz. 12 persons, 16 persons or 22 persons) can be offered by
using the drive and related parts meant for the next higher capacity. Car size will be altered so as to not violate
the permitted car internal area to capacity norm. Hoist-way size required will be determined by the differences
between car internal width and hoist-way width and car internal depth and hoist-way depth respectively for the
next higher capacity. However, the hoist-way width required for the next higher capacity will be required to
provide door opening width shown for the next higher capacity.
9. Please refer to Kinetic Hyundai for sizes for machine room type elevators with counterweight on a side (such as
in service elevators with deep car).
10. Pit depth 1600mm mandated in IS is acceptable but 1800mm is recommended at speed at 1.5 MPS.
11. Counterweight safety application is mandatory in case of floating pit (void left below the pits bottom in case of
lift starting from floor other than the lowest). This makes pit depth requirement 400-450mm more. In addition,
an additional concrete slab is required below and at least 300mm below the pit's bottom.
12. Above overhead requirements are with Hyundai's standard lift door height, 2100mm and will be higher for taller
doors. Requirement of taller (2200mm or 2400mm high) doors, hence taller car, may entail use of drive and
related parts meant for a higher capacity due the increased dead load of car (please see point no.14 below).
13. Above machine room sizes are for single elevators. Overall size of a combined machine room for a number of
elevators in a group can be slightly lower than the sum of the individual machine room sizes. Please consult
Kinetic Hyundai for the same.
14. Standard finishing allowance is 10% of the rated capacity. This is sufficient for marble/ granite flooring in 20mm
recess. Higher finishing allowance requirement (or requirement of taller doors, hence taller car) may entail use
of drive and related parts meant for a higher capacity. In such case, hoist-way clearances (differences between
car internal width and hoist-way width and car internal depth and hoist-way depth respectively) will also be
required as applicable to the higher capacity. Taller doors or higher finishing allowance are not offered for MRL
elevators with rated capacity 24 persons. Requirement of 24 person rated capacity machine room type
elevators with taller doors or higher finishing allowance may be referred to Kinetic Hyundai.
16 Section of Hoistway
17
Nude Elevators Observation Elevators Machine Room Type Only
Notes:
Capacity Minimum 11 persons (748 KG),
Maximum 20 persons (1360 KG)
Speed - Maximum 1.75 MPS
Glass Window 3 Piece Safety Glass Glass Window 3 Piece Safety Glass
Car Walls SS, Hairline Finish (Options SS Mirror Finish / Car Walls SS, Hairline Finish (Options SS Mirror Finish /
Etched and Mild Steel Powder Coated) Etched and Mild Steel Powder Coated)
Ceiling Milky White Acrylic in MS Powder Coated Frame Ceiling Milky White Acrylic in MS Powder Coated Frame
with Decorative Lighting with Decorative Lighting
Glass Window 3 Piece Safety Glass Glass Window 3 Piece Safety Glass
Outer Domes Milky White Acrylic Outer Domes SS, Hairline Finish, With Lights
SS, Hairline Finish (Options SS Mirror Finish / Car Walls SS, Hairline Finish (Options SS Mirror Finish /
Car Walls
Etched and Mild Steel Powder Coated) Etched and Mild Steel Powder Coated)
Acrylic in MS Powder Coated Frame Ceiling Milky White Acrylic in MS Powder Coated Frame
Ceiling with Decorative Lighting
with Decorative Lens Lighting
Notes: Notes:
Capacity (Machine Room Type) Minimum 11 persons (748 KG), Maximum 20 persons (1360 KG) Capacity (Machine Room Type) Minimum 11 persons (748 KG), Maximum 20 persons (1360 KG)
20 Capacity (MRL) - Minimum 11 persons (748 KG), Maximum 15 persons (1020 KG) Capacity (MRL) - Minimum 11 persons (748 KG), Maximum 15 persons (1020 KG) 21
Speed - Maximum 1.75 MPS Speed - Maximum 1.75 MPS
Observation Elevators Machine Room Type As Well As MRL Observation Elevators Machine Room Type As Well As MRL
Notes:
Capacity (Machine Room Type) Minimum 11 persons (748 KG), Maximum 20 persons (1360 KG)
22 Capacity (MRL) -
Speed -
Minimum 11 persons (748 KG), Maximum 15 persons (1020 KG)
Maximum 1.75 MPS
23
Observation Elevators Machine Room Type As Well As MRL Freight & Automobile Elevators
Plan of Hoistway
Capsules SHGQ004, SHGQ007,
SHGQ008 & SC-846A
Plan of Hoistway
Capsules SHGQ-F02, SHGQ002
Plan of Hoistway
Capsule SHGQ015
24 NOTE: Hoist-way sections for MRL and Machine Room Type shown for one capsule type each for illustration. Will be similar for other capsules. 25
Freight Elevators - Planning Guide Freight Elevators - Planning Guide
General Type (2S, 2SCO, 2U)
R2
Height (MH)
Double
M/C Room
CA
Cinder Concrete 60
Min. 150 Entrance 1900 x 2100
900(W) x 2000(H)
2U 1900 X 2100 1980 x 2298 2950 x 2700
F2000-2U 4600
Machine Room
45 2950 x 2876 3800 x 4200
Double 1980 x 2416
60
OP Entrance
Distribution Board(By Others)
30 Standard
2S 1700 X 2100 2100 x 2300 2180 x 2510 3100 x 2800
Overhead(OH)
F2500-2SCO 45 4800 4000 x 4400
Double 2180 x 2640 3100 x 2940
(60)
Entrance
2-Panel Side-Opening Doors (2S)
30 Standard
2U 2100 X 2100 2180 x 2498 3100 x 2900
(Note) Temperatures should be maintained below 40oC with ventilating fan F2500-2U 45 4600 4000 x 4400
and / or air conditioner (if necessary) and humidity below 90% Double 2180 x 2616 3100 x 3076
(60)
Entrance
Total Height (TH)
30 Standard
2SCO 1800 X 2300 2300 x 2500 2380 x 2710 3300 x 3000
F3000-2SCO 45 4800 4200 x 4800
Double 2380 x 2840 3300 x 3140
Entrance
30 Standard
2U 2300 X 2100 2380 x 2698 3300 x 3100
F3000-2U
Travel (TR)
25 3700 x 3400
120
25 Standard
Depth (PP)
4-Panel Center Opening Doors (2SCO) 2U 2500 X 2100 2580 x 3098 3700 x 3500
F4000-2U 30 5500 4700 x 6400
Pit
Building Requirements
Wall - finished
50 OP 50
26 27
Standard Features for Passenger & Freight Elevators
Selective Collective Control Selective automatic operation by collective all call signals
VVVF Inverter Drive With Accurately adjusts motor speed, which makes elevator start, run and stop smoothly.
Close Loop Encoder
Feedback
VVVF Inverter Door Drive Accurately adjusts door motor speed, which makes door start, open & close and stop
With Close Loop Encoder smoothly.
Feedback
Inspection Operation When inspection switch actuates car inching operation at speed 0.3m/s.
Automatic Overload Bypass Crowded car with load more than a preset value bypasses hall calls.
Fireman’s Emergency Return When the key switch at main floor is activated or signal is received from fire detection
and Fireman’s Emergency system, all calls are canceled and car returns immediately to main floor, then door
Operation opens. Thereafter car responds only to car call, to facilitate rescue.
Car Arrival Chime Electronic chime mounted on car top sounds to indicate the car's arrival.
Dot Matrix Display Indication Car position displays inside car and on landings with scrolling arrow to indicate the
direction in which the car is running.
Reverse Car Call When the car responds to the final car call in one direction, the system automatically
Cancellation clears the remaining calls in the other direction from its memory.
False Call Canceling – If a mistake is made when pressing a floor button, simply pressing the same button
Button Operation again cancels the call.
False Call Canceling – If the number of car calls registered is not in proportion with the lift’s capacity, all calls
Automatic are canceled in order to avoid unnecessary stops.
Owner Skip Operation Temporarily locking (by-passing) a floor as per customer’s requirement.
Ventilation Fan Lift is fitted with sound free axial flow fan fitted above and hidden by false ceiling.
Car Ventilation Auto Shut Off If there is no call registered within a predetermined period of time, i.e. the elevator is
idle, car fan is automatically shut off to conserve energy.
Car Light Auto Shut Off If there is no call registered within a predetermined period of time, i.e. the elevator is
idle, car light is automatically shut off to conserve energy.
Overload Holding St op Overloaded car cannot leave the floor and a buzzer is sounded.
Attendant Service Elevators can be changed over to attendant service from normal full automatic
-
operation by an override switch in the car operating panel.
Repeated Door Closing and If an obstacle prevents the doors from closing, the doors repeatedly open and close
Openi ng until the obstacle is cleared.
Lift Operation Counter The controller records the number of elevator running operations performed.
Fault Indication When elevator stops due to a fault, the fault is recorded and displayed in the
controller.
Emergency Car Lighting When power fails, battery operated emergency light in car turns ON immediately.
Multi-beam Door Protection Multiple infrared -light beams cover the full width and height of the door as the door
opens or closes, to detect passengers or objects.
Interphone with Battery Back A three way interphone system comprising a press and speak unit in car operating
Up panel for the passengers and handset each at lift control panel and main lobby.
Optional Features
Safety Edge Door Protection Conventional sensitive mechanical door edge to detect pressure from passenger and
objects, in lieu of or together with multi
- beam protection.
Voice Synthesizer Floor and elevator status announcement.
Duplex Control Optimizes the operation of a pair of elevators by dispatching the nearest car to attend
a call.
Group Control Optimizes the operation of a group of 3 to 8 cars by minimizing waiting time, zonal
distribution and energy conservation.
Auxiliary Car Operating Extra car operating panel in large-capacity elevator for passenger convenience. Can
Panel be regular vertical layout type or handicap type.
Swing Type Car Operating Full height car operating panel– an entire return panel forms the car operating panel
Panel plate.
Emergency Landing Device In case of normal power’s failure, a rechargeable battery moves the car to the
ELD (Automatic Rescue nearest floor.
Device ARD)
Dual Floor Fireman’s In case of fire sign al from the building’s fire detection system, return to a floor other
Emergency Return than the main floor if the fire signal is from the main floor.
Supervisory Panel Common display panel (for building control room or lobby or security room) with a car
position and status display for each lift.
Hall Lantern Predictive attractive flashing up and down indicator lights above the landing doors of
lifts in a group to indicate to waiting passengers the lift expected to arrive at the floor.
28 BMS contact Potential free contacts for BMS at lift control panel, with signals on lift position and 29
status.