125W Dual Output Switching Power Supply: Series

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

125W Dual Output Switching Power Supply RD-125 series

Features :
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105 long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty

SPECIFICATION
MODEL RD-125A RD-125B
OUTPUT NUMBER CH1 CH2 CH1 CH2
DC VOLTAGE 5V 12V 5V 24V
RATED CURRENT 7.7A 7.7A 4.6A 4.6A
CURRENT RANGE Note.6 2 ~ 15A 0.5 ~ 10A 2 ~ 10A 0.4 ~ 5A
RATED POWER Note.6 130.9W 133.4W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 120mVp-p
OUTPUT
VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 5.0% 7.0% 5.0% 7.0%
LINE REGULATION Note.4 1.0% 2.0% 1.0% 2.0%
LOAD REGULATION Note.5 3.0% 4.0% 3.0% 4.0%
SETUP, RISE TIME 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 25ms/230VAC 30ms/115VAC at full load
VOLTAGE RANGE 88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC(Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 82% 85%
INPUT
AC CURRENT (Typ.) 3A/115VAC 2A/230VAC
INRUSH CURRENT (Typ.) COLD START 40A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
110 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
CH1: 5.75 ~ 6.75V
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP. -25 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT 0.03%/ (0 ~ 50 )on CH1 output
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved
SAFETY & WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
EMC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
(Note 7) EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
MTBF 232.4Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION 199*98*38mm (L*W*H)
PACKING 0.7Kg; 20pcs/15Kg/0.8CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.

File Name:RD-125-SPEC 2011-08-19


125W Dual Output Switching Power Supply RD-125 series

Features :
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105 long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty

SPECIFICATION
MODEL RD-125-1224 RD-125-1248 RD-125-2448
OUTPUT NUMBER CH1 CH2 CH1 CH2 CH1 CH2
DC VOLTAGE 12V 24V 12V 48V 24V 48V
RATED CURRENT 3.7A 3.7A 2.3A 2.3A 2A 2A
CURRENT RANGE Note.6 1 ~ 7A 0.4 ~ 5A 1 ~ 7A 0.2 ~ 2.5A 0.5 ~ 4A 0.2 ~ 2.5A
RATED POWER Note.6 133.2W 138W 144W
RIPPLE & NOISE (max.) Note.2 120mVp-p 200mVp-p 120mVp-p 240mVp-p 200mVp-p 240mVp-p
OUTPUT
VOLTAGE ADJ. RANGE CH1: 11.4 ~ 13.2V CH1: 11.4 ~ 13.2V CH1: 22.8 ~ 26.4V
VOLTAGE TOLERANCE Note.3 2.0% +8,-5% 2.0% +8,-5% 1.0% 4.0%
LINE REGULATION Note.4 0.5% 1.0% 0.5% 1.0% 0.5% 1.0%
LOAD REGULATION Note.5 1.0% 5.0% 1.0% 5.0% 1.0% 3.0%
SETUP, RISE TIME 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 25ms/230VAC 30ms/115VAC at full load
VOLTAGE RANGE 88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC(Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 85% 86% 86%
INPUT
AC CURRENT (Typ.) 3A/115VAC 2A/230VAC
INRUSH CURRENT (Typ.) COLD START 40A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
110 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
CH1: 13.8 ~ 16.2V CH1: 13.8 ~ 16.2V CH1: 27.6 ~ 32.4V
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP. -25 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT 0.03%/ (0 ~ 50 )on CH1 output
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved
SAFETY & WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
EMC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
(Note 7) EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
MTBF 218.2Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION 199*98*38mm (L*W*H)
PACKING 0.7Kg; 20pcs/15Kg/0.8CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.

File Name:RD-125-SPEC 2011-08-19


125W Dual Output Switching Power Supply RD-125 series

Features :
Protections:Short circuit/Overload/Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105 long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty

SPECIFICATION
MODEL RD-125-2412 RD-125-4812 RD-125-4824
OUTPUT NUMBER CH1 CH2 CH1 CH2 CH1 CH2
DC VOLTAGE 24V 12V 48V 12V 48V 24V
RATED CURRENT 3.7A 3.7A 2.3A 2.3A 2A 2A
CURRENT RANGE Note.6 0.5 ~ 5A 1 ~ 7A 0.3 ~ 2.5A 1 ~ 7A 0.3 ~ 2.5A 0.5 ~ 4A
RATED POWER Note.6 133.2W 138W 144W
RIPPLE & NOISE (max.) Note.2 200mVp-p 120mVp-p 240mVp-p 120mVp-p 240mVp-p 240mVp-p
OUTPUT
VOLTAGE ADJ. RANGE CH1: 22.8 ~ 26.4V CH1: 45.6 ~ 52.8V CH1: 45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.3 2.0% 10% 2.0% 10% 1.0% 8.0%
LINE REGULATION Note.4 0.5% 1.0% 0.5% 1.0% 0.5% 1.0%
LOAD REGULATION Note.5 1.0% 5.0% 1.0% 5.0% 1.0% 5.0%
SETUP, RISE TIME 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 25ms/230VAC 30ms/115VAC at full load
VOLTAGE RANGE 88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC(Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 85% 86% 86%
INPUT
AC CURRENT (Typ.) 3A/115VAC 2A/230VAC
INRUSH CURRENT (Typ.) COLD START 40A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
110 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
CH1: 27.6 ~ 32.4V CH1: 55.2 ~ 64.8V CH1: 55.2 ~ 64.8V
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP. -25 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT 0.03%/ (0 ~ 50 )on CH1 output
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved
SAFETY & WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
EMC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
(Note 7) EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
MTBF 232.4Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION 199*98*38mm (L*W*H)
PACKING 0.7Kg; 20pcs/15Kg/0.8CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.

File Name:RD-125-SPEC 2011-08-19


125W Dual Output Switching Power Supply RD-125 series

Mechanical Specification Case No. 902A Unit:mm

197

7
12

3.5
1
2
9.5

85.5
4

98
80

5
8.2

6
7
3
M
3.5 4-

4.5 57.5 120


199

6.5 190

Terminal Pin No. Assignment


9.5
9

18

Pin No. Assignment Pin No. Assignment


3.5
3.5

18

38
3-M 1 AC/L 4,6 DC OUTPUT COM
28.5

3
2 AC/N 5 DC OUTPUT +V2
3 FG 7 DC OUTPUT +V1
22 157

Block Diagram fosc : 60KHz


230 RECTIFIERS
115 & +V2
FILTER

EMI RECTIFIERS POWER RECTIFIERS +V1


I/P FILTER & SWITCHING &
COM
FILTER FILTER

DETECTION
FG
CIRCUIT
O.L.P. CONTROL
O.V.P.

Derating Curve Static Characteristics

Ta=25
100
100
90
80
80

60 70
LOAD (%)

LOAD (%)

60
40
50
20
40

-25 0 10 20 30 40 45 50 60 70 (VERTICAL) 88 95 100 115 120 132


-25 0 (HORIZONTAL)
176 190 200 230 240 264
AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (VAC) 60Hz

File Name:RD-125-SPEC 2011-08-19