First Basis Vaccum Requirements Pressure Requirements

This document contains information about pump rates and pressure requirements for two bases. For the first basis, the pump-in rate is 522.6 m3/hr and pump-out rate is 48.7 m3/hr. The total pressure requirement is 9451.7 Nm3/hr and total vacuum requirement is 1925.5 Nm3/hr. For the revised basis, the pump-in rate is 450 m3/hr and pump-out rate is 127.76 m3/hr. The total pressure requirement is 9304.4 Nm3/hr and total vacuum requirement is 2000.0 Nm3/hr. Both bases require a 10 or 12 inch valve with similar pressure and

Uploaded by

sohaib
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
55 views1 page

First Basis Vaccum Requirements Pressure Requirements

This document contains information about pump rates and pressure requirements for two bases. For the first basis, the pump-in rate is 522.6 m3/hr and pump-out rate is 48.7 m3/hr. The total pressure requirement is 9451.7 Nm3/hr and total vacuum requirement is 1925.5 Nm3/hr. For the revised basis, the pump-in rate is 450 m3/hr and pump-out rate is 127.76 m3/hr. The total pressure requirement is 9304.4 Nm3/hr and total vacuum requirement is 2000.0 Nm3/hr. Both bases require a 10 or 12 inch valve with similar pressure and

Uploaded by

sohaib
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

3

Pump‐in Rate          = 522.6 m /hr.


FIRST BASIS
Pump‐out Rate       = 48.7 m3/hr.
PRESSURE REQUIREMENTS VACCUM REQUIREMENTS

Pump‐in Rate 1060.2 Nm3/hr. Pump‐out Rate


3
46.0 Nm /hr.
Thermal 1879.5 Nm3/hr. Thermal
3
1879.5 Nm /hr.
Regulator Failure 6512 Nm3/hr.
TOTAL 9451.7 Nm3/hr. TOTAL
3
1925.5 Nm /hr.
Valve Size 12 inch
Valve Quantity 1
Pressure Setpoint 18 mbarg
Over‐Pressure 2 mbarg
Vacuum Setpoint 2.5 mbarg
Over‐Vaccum 0.5 mbarg

Pump‐in Rate          = 450 m3/hr.


REVISED BASIS 3
Pump‐out Rate       = 127.76 m /hr.
PRESSURE REQUIREMENTS VACCUM REQUIREMENTS

Pump‐in Rate 912.9 Nm3/hr. Pump‐out Rate


3
120.5 Nm /hr.
Thermal 1879.5 Nm3/hr. Thermal
3
1879.5 Nm /hr.
Regulator Failure 6512 Nm3/hr.
TOTAL 9304.4 Nm3/hr. TOTAL
3
2000.0 Nm /hr.
Valve Size 10 inch
Valve Quantity 2
Pressure Setpoint 18 mbarg
Over‐Pressure 2 mbarg
Vacuum Setpoint 2.5 mbarg
Over‐Vaccum 0.5 mbarg