SOs aa MES e eek rue move. LDM-170 DISTORTION METER OPERATING INSTRUCTIONS. LEADER ELECTRONICS CORP. CONTENTS SECTION PAGE 1 DESCRIPTION LL General eee e eee : 2 1.2 Specifications. A 1.3 Panel Functions 5 2 OPERATION 2.1 Distortion Measurement 2a.L Preliminary Notes 4 2.1.2 Preparation cette 5 2.1.3 Tuning and Balancing Adjustments é 214 Measurements at 0.1 ~ 300mVems input 6.6 6eeeeeeeeeeeeeey 21.8 Use of an Oscilloscope a 2.1.6 Examples of Measurements 2.2. SIN Measurement “2 23° Voltage Measurement ra Tes Gonenal ree teat ee eer eee eee eres 23.2 Operation ooo cece cece eeeeeeeeeeeee ee eeeeeeeeeee ee dg 3 PRINCIPLE OF OPERATION 3.1 Distortion Measurement 1b 3.2. SIN Measurement 16 3.3 Voltage Measurement 00000 ceceeeeeee eee eveeeeeeeeeeeeeeeeeeay BA High pass FRC cece e eee e cece cette ee eeeeeeeag 35 DC Power Supply on 4 MAINTENANCE Erg ea anerele ee ee eeereerer 4.2 Cover Removal 8 43° Circuit Adjustments 43.1 Location of Adjusters ; oe 5 4.3.2 ‘Test Equipment Required -..0..6cceceeeee eee “9 43.3 Checks and Adjustments 00.00 cc cee cess sete eee essere enag, OPERATING INSTRUCTIONS SECTION 1 DESCRIPTION 42 General ‘The LDM-170 measures the distortion, SN (signal to-noise ratio), and signal levels in audio frequency circuit. ‘A highly selective balancing network is used to eliminate the fundamental frequency in che 20H to 20kHs ba ‘The distortion products are fed to a stable high gain wideband amplifier for indication on the mecer. The aml is effective up to 200kHz and measurements are posible up to and including the tenth harmonie of 20kHe, ‘The balancing network is switched out when measuring the noise and signa levels whereby the high gain ampli is used as a sensitive voltmeter. SSIN can be measured to 70dB below the reference level can be measured for frequencies between 20H2 and 200kHz. In addition, signal levels in the 100HV to 300V ra (Output terminal are provided for scope connections when observing the distortion components andjor noise. | Specifications Distortion Measurement Range 0.3%, 155, 3, 10%, 30% and 100% ful scale Accuracy +505 of full scale, at 30% and lower ranges. Frequency Range 20H to 20kHe (fundamental) in three bands: calibration accuracy within * balancing controls provided, Input Voltage Range 0.35 to 30Vems. Input Impedance Approx. 100k: less than SOpF in shunt. Fundamental Suppression Over 70dB. Residual Distortion lets than 0.03%. Harmonie Attenuation Within 0.54B (2nd and 3rd harmonics. SIN (Noize) Measurement Range (010 70dB below the reference level. Input Voltage Range 0.35 c0 30Vrms ‘Level Measurement Voltage Range mV to 300Vems in 12 ranges: minimum ecading, 0.1m¥. Accuracy 595 of full sale Frequency Range 2012 to 200kHe, Highpass Filter ‘Cutoff at 500H2: 6éBJoctave attenuation. ‘Monitor Output Approx. 1Vems xt fall scale reading; output impedance, approx. 1k9. Operating Temp. Range oF wo 40°C.

You might also like