Barber Colman
Barber Colman
Barber Colman
LOGIC
Relays and Timers 2-2
Contact Material AgNi, AgNi + Gold AgNi, AgNi + Gold AgNi, AgNi + Gold
Max. operating
10 A (DPDT)
current under 10 A 8 A (DPDT), 16 A (SPDT)
7 A (4PDT)
resistive load
Coil Ratings
AC: 6V, 12V, 24V, 48V, 110V,
120V, 208V, 230V, 240V, 277V
AC: 6V, 12V, 24V, 120V, 240V AC: 6V, 12V, 24V, 120V, 240V
Coil Voltage DC: 6V, 12V, 24V, 36V, 48V,
DC: 6V, 12V, 24V, 48V, 110V DC: 6V, 12V, 24V, 48V, 110V
60V, 80V 110V, 125V, 140V,
220V
Electrical Ratings
Pole-to-pole: 2000V Pole-to-pole: 1600V Pole-to-pole: 1500V AC
Dielectric
Contact-to-coil: 2000V Contact-to-coil: 1600V Contact-to-coil: 1500V AC
Withstand Voltage
Contact-to-frame: 2000V Contact-to-frame: 1600V Contact-to-frame: 1500V AC
Electric Service
100,000 minimum 100,000 minimum 100,000 minimum
Life (cycles)
Reference
Certifications CE, cULus, cURus, Lloyds CE, cULus, cURus, Lloyds CE, UL, UR, CSA
700-HN100, 700-HN101,
700-HN103, 700-HN128, 700-HN121, 700-HN221
Socket Cat. No(s). 700-HN125, 700-HN126,
700-HN104 700-HN122, 700-HN222
700-HN204, 700-HN205
Product Selection Page 2-6 Page 2-9 Page 2-10
LOGIC
Contact Type Single Single Single
Contact Material AgSnO AgSnO AgNi, AgNi + Gold
Max. operating
current under 6 A (SPDT), 2 A (SSR) 10 A 8A
resistive load
Coil Ratings
AC: 12V, 24V, 48V, 110V, AC: 24V, 48V, 110V, 120V,
120V, 230V, 240V 230V, 240V AC: 6V, 12V, 24V, 120V, 240V
Coil Voltage
DC: 12V, 24V, 48V, 125V, DC: 12V, 24V, 48V, 125V, DC: 6V, 12V, 24V, 48V, 110V
230V, 240V 230V, 240V
Electrical Ratings
Pole-to-pole: 1000V AC Pole-to-pole: 1000V AC
Dielectric Pole-to-pole: 2000V
Contact-to-coil: 4000V Contact-to-coil: 5000V
Withstand Voltage Contact-to-coil: 5000V
Contact-to-frame: 1500V Contact-to-frame: 2500V
Electric Service
100,000 minimum 100,000 minimum 100,000 minimum
Life (cycles)
Reference
Certifications CE, cURus, cULus, ABS CE, cURus, cULus CE, cULus, cURus, Lloyds
Socket Cat. No(s). — — 700-HN123
Product Selection Page 2-11 Page 2-12 Page 2-14
Off-Delay
One Shot
Operation Modes: 11 Different Timing Modes
Repeat Cycle-Pulse
Fleeting Off-Delay
Pulse Converter
Time Range 0.05 s…10 h 0.05s…60 h
24V AC/DC
12V DC
110…240V AC
Supply Voltage 24V…48V DC
24V…48V AC/DC
24V…240V AC
24V…240V AC
Contact Rating at
5A 8A
120V AC
Certifications CE, cULus CE, cULus
Product Selection Page 2-16 Page 2-18
LOGIC
Break Break
X-Mark and X-Mark and
Contact Type Cross Stamp, Bifurcated
Bifurcated Bifurcated
Contact Material Silver-Copper Silver-Copper Silver, Gold
Electrical
Max. Current AC 20 A (Relay)
15 A 15 A
Resistive 10 A (Adder Deck)
Bifurcated contacts
17V, 30 mA (700-M) 17V 10 mA (Silver)
Min. load for high contact
17V 5 mA (700-MB) 5V 3 mA (Gold)
reliability
12…600V AC 24…480V AC 12…600V AC
Coil Voltage
9…250V DC 12…220V DC 9…250V DC
Coil Voltage 85…110% AC Coils, 85…110% AC Coils, 85…110% AC Coils,
Pickup 80…110% DC Coils 80…110% DC Coils 80…110% DC Coils
Dielectric
2640V 2640V 2640V
Withstand
Reference
Electric Service
800'000 at 10 A 800'000 at 10 A 1'200'000 at 10 A
Life (cycles)
Certifications CE, cULus CE, cULus, CSA CE, cULus, CSA
DIN Rail or Panel DIN Rail or Panel
Sockets DIN Rail or Panel Mount
Mount Mount
Product Selection Page 2-22 Page 2-24 Page 2-26
10 A Contact Rating
DPDT, 3PDT
Pin Style Terminals
Standard ON/OFF Flag Indicator
Options: LED, Push-to-Test and Manual Override, Socket Mounted
Surge Suppressor Module, or Multifunction Timer
Contact Choices: Standard Silver Nickel, Bifurcated Silver Nickel, or
Bifurcated with Gold Plating
Bulletin 700-HA Tube Base Relay with PIN Terminals (Single Contact) —
Mechanical ON/OFF Indicator included 1
Description Wiring Diagrams Contact Rating Coil Voltage Cat. No. ‡§
24V AC 700-HA32A24 11.00
DPDT 230V AC 700-HA32A03 11.60
2-pole
240V AC 700-HA32A2 15.60
2 Form C 10 A
Single AgNi Contact B300 24V DC 700-HA32Z24 11.00
110V DC 700-HA32Z1 12.50
700-HN100
Sockets 220V DC 700-HA32Z2 16.50
700-HN204
LOGIC
LOGIC
relays, -HR and -HT (Off-Delay) timing relays. Order must be for
10 sockets or multiples of 10.
8-Pin Socket — Can Be Used With or Without Timing
Attachment or Surge Suppressor
Screw Terminal Tube Base Sockets — panel or DIN Rail
10 700-HN204 5.36
mounting. Guarded terminal construction. Used with DPDT
Bulletin 700-HA Relays. Order must be for 10 sockets or
multiples of 10.
11-Pin Socket — Can Be Used With or Without Timing
Module or Surge Suppressor.
Screw Terminal Tube Base Sockets — panel or DIN Rail
10 700-HN205 5.97
mounting. Guarded terminal construction.
Used with 3PDT Bulletin 700-HA relays. Order must be for 10
sockets or multiples of 10.
PQ = Package Quantity
1
Voltage Range: 12…24V 1 700-AT2 28.20
AC/DC used with 700-
HN204/205 socket
Multi-Function Multi-Range Time Module 1
Voltage range 12…240V AC 50/60 Hz and 12…240V DC, with a
voltage variation of 85…110%. Repeat accuracy of ±1%. Reset
time <50 ms. 1 700-HT3 41.30
Choice of 8 functions
Choice of 8 time ranges 0.1…240 h
Use with sockets 700-HN204/205
1 Suppressors and timing modules easily plug into sockets (Cat. nos. 700-HN204 and 700-HN205). For use with
Bulletin 700-HA relays.
PQ = Package Quantity
ATTENTION: Cat. No. 700-HT3 is wired with signal “S” connected to “A1”.
See wiring diagram marked on the timer module.
10 A Contact Ratings
2PDT or 4PDT
Standard ON/OFF Flag Indicator
Blade Style Terminals
Choice of Standard Silver Nickel Contacts, or Silver Nickel with Gold
Plated Contacts for Low Energy Applications
Options: LED, Push-to-Test with Manual Override Option
Tungsten UL Approvals
4-Pole: 5A @ 24V DC
2-Pole: 10A @ 24V DC
LOGIC
Sockets 24V DC 700-HC22Z24-3 7.79
700-HN104
24V AC 700-HC24A24-3 8.25
4PDT
4-Pole 240V AC 700-HC24A2-3 8.95
4 Form C 10 A
Contacts: Low energy rating; 1
10A = AgNi (10V, 1 mA) 24V DC 700-HC24Z24-3 8.25
Contacts
10 700-HN221 7.27
Socket Base
10 700-HN222 8.30
1 LED option: Add suffix (-4) to the selected Bulletin 700-HK relay cat. no. except for the 240V AC units, add (-4L).
Push-to-test and LED option: Add suffix (-3-4) to the selected Bulletin 700-HC relay cat. no., except for the
240V AC units, add (-3-4L).
‡ For AgCdO contact with gold overlay: Replace “3” with “X” in cat. no. For example, if cat. no. 700-HK36A1 is
required with gold overlay, the new catalog number is 700-HKX6A1.
PQ = Package Quantity
SPDT Relays
Cat. No.
Cat. No. (Spring
Assembled Devices Output (Screw Clamp
Input Voltage Type PQ Terminals) Terminals)
24V DC 10 ♣ 700-HLT1Z24 13.30 700-HLT2Z24 13.00
24V AC/DC 10 700-HLT1U24 15.30 700-HLT2U24 15.00
110/125V AC/DC 10 ♣ 700-HLT1U1 18.60 700-HLT2U1 18.20
220…240V AC/DC 10 700-HLT1U2 18.60 700-HLT2U2 18.20
SPDT
Built-in LCSC (leakage (1 C/O);
current suppression Ith = 6A1 10 700-HLT1L1 24.60
circuit)
120V AC and 125V DC§
LOGIC
Built-in LCSC (leakage
current suppression 10 700-HLT1L2 24.60
circuit) 240V AC§
Solid State
Cat. No.
Cat. No. (Spring
Assembled Devices Output (Screw Clamp
Input Voltage Type PQ Terminals) Terminals)
24V DC 10 ♣ 700-HLS1Z24 29.90 700-HLS2Z24 29.90
110/125V AC/DC 10 ♣ 700-HLS1U1 32.80 700-HLS2U1 32.80
220…240V AC/DC 1 N.O. 10 700-HLS1U2 32.80 700-HLS2U2 32.80
Built-in LCSC (leakage solid-
current suppression state;
10 700-HLS1L1 29.90
circuit) Ith = 2 A,
120V AC and 125V DC§ 24V DC‡
Built-in LCSC (leakage
current suppression 10 700-HLS1L2 35.40
circuit) 240V AC§
1 For gold-plated contacts: Add the letter “X” at the end of the catalog number. For example: if cat. no.
700-HLT1Z24 is required with gold plating, the new cat. no. is 700-HLT1Z24X.
Electromechanical relay to solid-state relay interchangeability is possible.
‡ Reverse polarity on the output terminals of the solid-state relay will result in the output being "On" regardless of
the state of the input voltage.
§ Leakage current suppression up to 2.2 mA off state current.
♣ Available as EX version. Add “-EX” at the end of the cat. no. (Example: 700-HLS1Z24-EX).
PQ = Package Quantity
Slim build of only 14mm wide that meets thedemand for panel
space-savings
Standard built-in reverse DC polarityprotection ensures DC coil
devices are notdamaged if improper polarity is connected
Separation of coil and contact terminals
Snap in marker system
One piece housing construction in terminal area to prevent
screwdriver blade from catching on housing seam
10 Amp Contact Rating
DPDT Relays
Cat. No. Cat. No.
Assembled Devices Output (Screw (Spring Clamp
Input Voltage Type PQ Terminals) Terminals)
24V DC 10 700-HLT12Z24 15.50 700-HLT22Z24 15.10
24V AC/DC DPDT 10 700-HLT12U24 17.90 700-HLT22U24 17.50
(2 C/O);
110/125V AC/DC Ith = 10 A1 10 700-HLT12U1 21.70 700-HLT22U1 21.20
220…240V AC/DC 10 700-HLT12U2 21.70 700-HLT22U2 21.20
1 For Gold-plated contacts: Add the letter "X" at the end of the catalog number. Example: Cat. No. 700-HLT12Z24
with gold plated contacts is catalog number 700-HLT12Z24X. The following relays are available with the gold-
LOGIC
LOGIC
inspection of groups,
safe separation of 700-HL
Black 10 700-HN177 0.94
neighboring 700-HL (1- /2-Pole)
modules that end with
jumpers. Order must be
for 10 or multiples of 10.
8-Way Jumper Red 700-TBJ08R 2.90
Can be cut to required Gray 700-HL 700-TBJ08G 2.90
1
length. Ith =10 A max per (2-Pole)
8-way jumper. Blue 700-TBJ08B 2.90
Snap-in Marker Blank 1492-MS6X12 4.92
These snap-in markers www.ab.com/
have a 6 x 12 mm Standard 1492- 700-HL
100 catalogs for /
surface and snap into MS6X12 (2-Pole) information
the ejection lever for the
relay. Custom
1 For gold-plated contacts: Add the letter “X” at the end of the catalog number. For example: if Cat. No. 700-
TBR24 is required with gold plating, the new cat. no. is 700-TBR24X. Gold-plated contacts with surcharge.
Go to http://www.ab.com/software/termblock/index.html and download software. Create custom text, save file,
and e-mail to your local Allen-Bradley distributor.
Note: Terminal block relay bases are not sold separately.
PQ = Package Quantity
8 A Contact Ratings
DPDT/ (2 c/o) Contacts
Plug-in PIN Style (PCB) Terminals (5 mm Pinning)
Choice of Standard Silver Nickel Contacts, or Silver Nickel with Gold
Plated Contacts
Options: None
700-HP
LOGIC
HN123 socket
One Shot Timing
Module
Voltage Range:
1 700-AT2 28.20
12…24V AC/DC
used with 700-
HN123 socket
PQ = Package Quantity
Single-Function
This device offers you one specific timing function.
Operating Contact
Mode Output Timing Range Input Voltage Cat. No.
0.75 s…1 h (4 24V AC/DC *
1 N.O. 700-FEA1SU22 41.20
settings) § 110…240V AC 50/60 Hz 1
ON-delay
0.05 s…10 h (6 24V…48V AC/DC
SPDT (1 C/O) 700-FEA3TU23 45.00
settings) ‡ 24…240V AC 50/60 Hz
0.75 s…1 h (4 24V AC/DC *
1 N.O. 700-FEB1SU22 43.60
settings) § 110…240V AC 50/60 Hz 1
OFF-delay
0.05 s…10 h (6 24V…48V AC/DC
SPDT (1 C/O) 700-FEB3TU23 47.50
settings) ‡ 24…240V AC 50/60 Hz
0.75 s…1 h (4 24V AC/DC *
1 N.O. 700-FED1SU22 41.20
LOGIC
Special Functions
Contact
Operating Mode Output Timing Range Input Voltage Cat. No.
2 N.O. with 0.15 s…10 min. 24V…48V AC/DC
Star-delta 700-FEY2QU23 60.90
1 Common (4 settings) ♣ 24…240V AC 50/60 Hz
1 Voltage is either 24V AC 50/60 Hz or 24V DC.
LOGIC
Time ranges: 0.5 s…10 s, 3…60 s, 0.5 s…10 min., 3…60 min.
♣ Time ranges: (3s) 0.15…3 s, (10s) 0.5…10 s, (1m) 0.05…1 min, (10m) 0.5…10 min
700-FS
24…48V DC
0.05…1 s 700-FSB3AU23 60.70
24…240V AC, 50/60 Hz
Off-delay
24…48V DC
0.5…10 s 700-FSB3CU23 60.70
24…240V AC, 50/60 Hz
24…48V DC
0.5…10 min 700-FSB3GU23 60.70
24…240V AC, 50/60 Hz
24…48V DC
0.05…1 s 700-FSC3AU23 60.70
24…240V AC, 50/60 Hz
On- and off-delay
24…48V DC
0.5…10 s 700-FSC3CU23 60.70
24…240V AC, 50/60 Hz
24…48V DC
0.05…1 s 700-FSD3AU23 53.50
24…240V AC, 50/60 Hz
One shot
24…48V DC
0.5…10 s 700-FSD3CU23 53.50
24…240V AC, 50/60 Hz
24…48V DC
Fleeting Off-delay 0.5…10 s 700-FSE3CU23 60.70
24…240V AC, 50/60 Hz
Flasher 24…48V DC
0.5…10 s 700-FSF3CU23 53.50
(repeat cycle starts with pulse) 24…240V AC, 50/60 Hz
Flasher 24…48V DC
0.5…10 s 700-FSG3CU23 53.50
(repeat cycle starts with pause) 24…240V AC, 50/60 Hz
24…48V DC
On-delay pulse generator 0.5…10 s 700-FSI3CU23 53.50
24…240V AC, 50/60 Hz
24…48V DC
On-delay (pulse controlled) 0.5…10 s 700-FSJ3CU23 60.70
24…240V AC, 50/60 Hz
One shot/watch dog 24…48V DC
0.5…10 s 700-FSK3CU23 60.70
(pulse controlled) 24…240V AC, 50/60 Hz
24…48V DC
Pulse converter 0.5…10 s 700-FSL3CU23 60.70
24…240V AC, 50/60 Hz
700–FS A 3 A U23
a b c d
a c
Operating Mode Timing Range
Code Description Code Description
A On-delay A 0.05…1 s
B Off-delay B 0.15…3 s
C On- and off-delay C 0.5…10 s
D One shot D 1.5…30 s
E Fleeting off-delay E 0.05…1 min
Flasher (repeat cycle starts F 0.15…3 min
F
with pulse) G 0.5…10 min
Flasher (repeat cycle starts H 1.5…30 min
G
with pause)
I 0.05…1 h
I On-delay pulse generator
J 0.15…3 h
On-delay (pulse
J K 0.5…10 h
controlled)
One shot/watch dog (pulse L 3.0…60 h
LOGIC
K
controlled) U 0.05 s…60 h1
L Pulse converter
d
b Input Voltage
Contact Output Code Description
Code All functions: U18 24…240V AC/DC
3 1 Changeover contact (SPDT) 24…48V DC
U23
24…240V AC 50/60 Hz
Z12 12 V DC
The timing range of "0.05 s…60 h" is selectable in 12 smaller ranges plus an ON and OFF function for
maintenance needs.
700-FSM
Operating Mode Contact Output Timing Range Input Voltage Cat. No.
24…48V DC
0.05 s…60 h 1 24…240V AC 700-FSM3UU23 73.10
50/60 Hz
Multi-function timing relays (SPDT) 1 C/O 24…240V
8 Single-functions: 0.05 s…60 h 1 700-FSM3UU18 92.20
AC/DC
A, B, C, D, E, F, I, and L
ON and OFF function 346…440V AC
0.05 s…60 h 1 700-FSM3UA40 82.10
additional 50/60 Hz
(for installation and 24…48V DC
maintenance) 0.05 s…60 h 1 24…240V AC 700-FSM4UU23 88.30
Note: See connection 50/60 Hz
diagrams for further
(DPDT) 2 C/O 24…240V
description. 0.05 s…60 h 1 700-FSM4UU18 119.00
AC/DC
LOGIC
346…440V AC
0.05 s…60 h 1 700-FSM4UA40 97.40
50/60 Hz
A 10h
(A) On-Delay
(B) Off-Delay
(C) On- and Off-Delay (1 s) 0.05…1 s
(D) One shot (3 s) 0.15…3 s
(E) Fleeting Off-Delay (10 s) 0.5…10 s
(F) Flasher (repeat cycle starts with pulse) (1 min) 0.05…1 min
(I) On-Delay pulse generator (3 min) 0.15…3 min
(L) Pulse converter (10 min) 0.5…10 min
(On) ON-Function (1 h) 0.05…1 h
(Off) OFF-Function (3 h) 0.15…3 h
(10 h) 0.5…10 h
Note: Switch ⊗ is on DPDT relays only. When switch is (60 h) 3.…60 h
down, one contact is instantaneous and one is timed.
When switch is up, both contacts are timed.
1 The time range of "0.05 s…60 h" is selectable in 12 smaller ranges plus an ON and OFF function for
maintenance needs.
For installation and maintenance.
700-FSH 700-FSY
Operating Mode Contact Output Timing Range Input Voltage Cat. No.
24…48V DC
0.05 s…60 h 1 24…240V AC 700-FSH3UU23 79.00
50/60 Hz
24…48V DC
Flasher (Repeat Cycle 2 x 0.05 s…60 h
24…240V AC, 700-FSH3VU23 81.60
Starting with Pulse or (SPDT) 1 C/O (2 ranges)
50/60 Hz
Pause)
346…440V AC
0.05 s…60 h 700-FSH3UA40 88.30
50/60 Hz
2 x 0.05 s…60 h 346…440V AC
700-FSH3VA40 90.60
(2 ranges) 50/60 Hz
OFF-delay without
LOGIC
supply voltages (True (SPDT) 1 C/O 700-FSQ3QU18 99.00
OFF-delay) ‡ 24…48V DC
0.15 s…10 m 24…240V AC
OFF-delay without 50/60 Hz
supply voltages (True (DPDT) 2 C/O 700-FSQ4QU18 127.00
OFF-delay) ‡
0.5 s…10 s 700-FSY2CU23 64.40
1.5…30 s 24...48V DC 700-FSY2DU23 64.40
0.05 s…1 min. 24...240V AC 700-FSY2EU23 64.40
0.15…3 min. 50/60 Hz 700-FSY2FU23 64.40
2 N.O. + 1 0.5…10 min. 700-FSY2GU23 64.40
Star-Delta
Common 0.5 s…10 s 700-FSY2CA40 70.90
1.5…30 s 700-FSY2DA40 70.90
346…440V AC
0.05 s…1 min. 700-FSY2EA40 70.90
50/60 Hz
0.15…3 min. 700-FSY2FA40 70.90
0.5…10 min. 700-FSY2GA40 70.90
1 The timing range of "0.05 s…60 h" is selectable in 12 smaller ranges plus an ON and OFF function for
maintenance needs.
This timing range is selectable in four smaller ranges: 0.15 s…2.5 s, 0.5 s…10 s, 4 s…80 s, 30 s…10 min.
‡ Due to shock during shipment, the state of the contacts should be verified before initial use.
Control Modules
Description PQ Cat. No.
Mechanical Interlock
LOGIC
For interlocking of two adjacent contactors
No added width to contactor assembly
1 100-KMCH 4.70
Front mount Plug-In type
Optional auxiliary contact blocks and suppressor modules
mount onto the interlock
24…48V AC 11 100-KFSC50
R-C Suppressor 110…280V AC 11 100-KFSC280 9.70
380…480V AC 11 100-KFSC480
12…55V AC /
Surge Suppressor 11 100-KFSV55
12…77V DC
Plug-in Type
Limits surge voltage MOV Suppressor 56…136V AC / 11 100-KFSV136 10.30
on coil drop-off 78…180V DC
137…277V AC /
11 100-KFSV277
181…250V DC
Diode
12…250V DC 11 100-KFSD250 5.80
Suppressor
1 May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-KFSC50M.
Ie [A] Ie [A]
40 °C 400V 500V N.O. N.C. Cat. No.
2 2 700DC-M220⊗S 28.60
3 1 700DC-M310⊗S 28.60
16 2.5 1.25
4 0 700DC-M400⊗S 28.60
1+1L 1+1L 700DC-MZ220⊗S 34.90
1 Mechanically Linked Contacts — Summary:
700-M, 700-MB, 700DC-M, and 700DC-MB relays are positively guided for 4 main poles. Restrictions apply
when using auxiliary contacts.
10-packs can be ordered for the following voltage codes: A1, A2, A24, Z24, D24. To order a 10-pack, specify
quantity in multiples of 10 and drop the final "S" from the catalog number.
LOGIC
Star-Delta Timer 220V AC 196-MTSDA2 80.40
48V 1 196-MTSDA3 80.40
35 mm DIN Rail Mounting Adapter
For easy mounting of timer modules on standard DIN Rail (EN 1 196-MTM 1.64
50 022-35) and G-Rail
24…48V AC 1 199-MSMNA48 9.71
R-C Suppressor 110…280V AC 100M 1 199-MSMNA280 9.71
380…480V AC 1 199-MSMNA480 9.71
12…55V
1 199-MSMV4 10.30
AC/12…77V DC
56…136V
MOV Suppressor 100-M 1 199-MSMV5 10.30
AC/78…162V DC
137…277V
1 199-MSMV6 10.30
AC/181…350V DC
Diode Suppressor 12…250V DC 100-M 1 199-MSMD2 5.78
1 Sold only in multiples of 10. Order (quantity of) 10 to receive one package of 10 pieces.
Bifurcated Contacts
AC-12 AC-15 Contacts
Ith [A] Ith [A]
40 °C 60 °C 240V 400V 525V N.O. N.C. Cat. No.
2 2 700-CFB220⊗ 29.60
20 20 10 6 2.5 3 1 700-CFB310⊗ 29.60
4 0 700-CFB400⊗ 29.60
May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 700-CFB220KFM).
⊗ The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table on page 2-27 to
complete the Cat. No. Example: Cat. No. 700-CF220⊗ becomes Cat. No. 700-CF220KF for 230V,
50/60 Hz.
Bifurcated Contacts
AC-12 AC-15 Contacts
Ith [A] Ith [A]
40 °C 60 °C 240V 400V 525V N.O. N.C. Cat. No.
2 2 700-CFB220⊗ 32,50
20 20 10 6 2.5 3 1 700-CFB310⊗ 32,50
4 0 700-CFB400⊗ 32,50
May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 700-CFB220ZJM).
LOGIC
Discount Schedule PRO
For Use
Description N.O. N.C. With Cat. No.
Auxiliary Contacts with Screw Terminals
Auxiliary Contact Blocks for Front 0 2 100-FA02 6.37
Mounting 1 1 100-FA11 6.37
2- and 4-pole
Quick and easy mounting without 2 0 100-FA20 6.37
tools
Electronic-compatible contacts
down to 17V, 5 mA 2 2 100-FA22 11.40
Mechanically linked performance
between N.O. and N.C. poles and to 700-CF
the main contactor poles (except for 3 1 100-FA31 11.40
L types)
Models with equal function with
several terminal numbering choices
1L = Late break N.C./early make 4 0 100-FA40 11.40
N.O.
Bifurcated version for switching
1+1L 1+1L 100-FAL22 11.40
down to 5V, 3 mA ‡
Auxiliary Contacts with Spring Clamp Terminals
Auxiliary Contact Blocks for Front 0 2 100-CRFA02 6.68
Mounting 1 1 100-CRFA11 6.68
2- and 4-pole
Quick and easy mounting without 2 0 100-CRFA20 6.68
LOGIC
tools
Electronic-compatible contacts
down to 17V, 5 mA 2 2 100-CRFA22 12.10
Mechanically linked performance
between N.O. and N.C. poles and to 700-CRF
the main contactor poles (except for 3 1 100-CRFA31 12.10
L types)
Models with equal function with
several terminal numbering choices
1L = Late break N.C./early make 4 0 100-CRFA40 12.10
N.O.
Bifurcated version for switching
1+1L 1+1L 100-CRFAL22 12.10
down to 5V, 3 mA ‡
1 Max. number of auxiliary contacts that may be mounted:
AC coil contactors — max. 4 N.O. contacts on the front of the contactor, 2 N.O. contacts on the side,
4 N.C. front or side, 6 total.
DC coil contactors — max. 4 N.O. contacts on the front of the contactor or max 2 N.O. contacts on the side,
4 N.C. front or side, 4 total.
May be ordered in package quantities of 10. Add letter M to the end of the cat. no. (Example: 100-FA02M).
‡ Selection data, see catalog A11_ or consult your local sales office.
LOGIC
200V AC, 5
Max Leakage 5 mA @ 100V, 10 mA @ 200V, 5 mA @ 100V
5 mA @ 100V, 10 mA @ 200V mA @ 50V DC
Current to Load 20 mA @ 400V AC
or 0.1mA @
100V DC
Zero Cross Load
Yes Yes (optional) Yes (optional) N/A
Switching
Equivalent
Electromechanical 1 N.O. 1 N.O. 1 N.O.
Relay Contact Form A Form A Form A
Arrangement
5…24V DC,
Rated Control 5…24V DC, 100…120V AC, 100…110V
5V DC, 12V DC, 24V DC 5...24V DC
(Input) Voltage 200…240V AC AC, 200/220V
AC
Yes (optional
LED Indicator Yes No Yes (optional)
for 48V DC)
Panel w/o heat sink, Panel or Panel w/o heat sink, Panel or
Mounting Method Panel or DIN w/socket
DIN w/heat sink DIN w/heat sink
Dielectric Strength 2500V AC, 50/60 Hz, 1 min. 2000V AC, 50/60 Hz, 1 min. 1500V AC, 50/60 Hz, 1 min.
Certification cURus, CE , TÜV 1 cURus, CE, TÜV cURus, CE, VDE
Max. Ambient
Operating -30…80°C (no condensation) -30…80°C (no condensation) -30…80°C (no condensation)
Temperature
Product Selection Page 2-31 Page 2-32 Page 2-33
1 With heat sink.
5 mA @ 100V,
Max Leakage
10 mA @ 5 mA @ 125V 1.5 mA 1 mA 5 μA 5 μA
Current to Load
200V
Zero Cross Load
Yes N/A Yes (optional) N/A No N/A
Switching
Equivalent
Electromechanical 1 N.O. 1 N.O.
Relay Contact Form A Form A
Arrangement
Rated Control
5…24V DC 5 … 24 V DC 5 … 24 V DC 5 … 24V DC 5 … 24V DC
(Input) Voltage
LED Indicator Yes Yes
Mounting Method Panel or DIN w/socket Panel or DIN w/socket
Dielectric Strength 1500V AC, 50/60 Hz, 1 min. 4000V AC, 50/60 Hz, 1 min.
Certification cURus, CE, VDE cURus, CE, TÜV
Max. Ambient
-30 … 80°C, (no
Operating -30 … 80°C (no condensation)
condensation)
Temperature
Product Selection Page 2-35 Page 2-36
700-SH
LOGIC
10 A @ 200…480V AC
5…24V DC 700-SH10HZ25 48.40
(47…63 Hz)
Phototriac 5…24V DC 700-SH25GZ25 23.40
25 A @ 24…240V AC
100…120V AC 700-SH25GA12 27.90
Photocoupler (47…63 Hz)
Yes Yes 200…240V AC 700-SH25GA22 27.90
25 A @ 200…480V AC
Photocoupler 5…24V DC 700-SH25HZ25 48.40
(47…63 Hz)
Phototriac 5…24V DC 700-SH40GZ25 43.50
40 A @ 24…240V AC
100…120V AC 700-SH40GA12 52.30
(47…63 Hz)
Yes Yes 200…240V AC 700-SH40GA22 52.30
Photocoupler
40 A @ 200…480V AC
5…24V DC 700-SH40HZ25 65.40
(47…63 Hz)
1 Maximum load current when mounted on the appropriate heat sink.
Accessories
Description Cat. No.
700-S10 14.90
700-S30 24.50
700-SE
5V DC 700-SE20GZZ05 20.10
20 A @ 100…240V AC
12V DC 700-SE20GZZ12 20.10
(47…63 Hz)
24V DC 700-SE20GZZ24 20.10
Phototriac
5V DC 700-SE05GNZ05 16.40
5 A @ 100…240V AC
12V DC 700-SE05GNZ12 16.40
(47…63 Hz)
24V DC 700-SE05GNZ24 16.40
5V DC 700-SE10GNZ05 18.00
10 A @ 100…240V AC
No No 12V DC 700-SE10GNZ12 18.00
(47…63 Hz)
24V DC 700-SE10GNZ24 18.00
5V DC 700-SE20GNZ05 21.10
20 A @ 100…240V AC
12V DC 700-SE20GNZ12 21.10
(47…63 Hz)
24V DC 700-SE20GNZ24 21.10
1 Maximum load current when mounted on the appropriate heat sink.
Accessories
Description Cat. No.
700-S10 14.90
700-S30 24.50
700-SC
LOGIC
Photocoupler Applicable
Yes 3 A @ 100…240V AC 4…24V DC 700-SCZN3Z26 21.30
Phototriac No (47…63 Hz) 24V DC 700-SCTN3Z24 21.30
No
Not 3 A @ 4…48V DC 4…24V DC 700-SCNN3Z26 21.30
Photocoupler
Applicable 2 A @ 5…110V DC 5…24V DC 700-SCNN2Z25 22.40
700-SA
LOGIC
Accessories
Description PQ Cat. No.
PQ = Package Quantity
Input/Sensor Module
Output/SSR Module
LOGIC
Accessories
Description PQ Cat. No.
Screw Terminal Socket — Panel or DIN Rail Mounting
5-blade miniature socket with 10 A rating for use with 1-
pole, Bulletin 700-HK relays. Accepts forked lug 10 700-HN121 7.27
conductors. Socket includes a retainer clip. Order must
be in multiples of ten.
PQ = Package Quantity
LOGIC
• Non-Contact Temperature Sensor
• Relay Output (electromechanical) • Relay Output
• Voltage Output for Solid-State Relay (electromechanical)
Control Output 1
• Triac Output (AC only) • Voltage Output for
• Analog Output 4…20 mA and 0…20 mA Solid-State Relay
• Voltage Output for • Voltage Output for Solid-
Control Output 2 Solid-State Relay State Relay (with option —
• Triac Output (AC only) unit)
Max. Number of Alarms 3 2 (with option unit) 1
RS-232C
Communications (with option unit) — —
Function
RS-485
Communications (with option unit) (with option unit)
Function
Event Input (with option unit) (with option unit) —
Run/Stop via Keypad or
Keypad
Interrupts
Multiple SP Selection
via Keypad
Keypad or Interrupts
Heater Burnout and
—
Heater Short Alarm
Product Selection Page 2-38 Page 2-39 Page 2-40
1 900-TC32 only available with 0…50 mV DC.
Supports
Heater Burnout
(Open) and
Power Max. No. Heater
Supply of Alarms Control Control Short-Circuit
Voltage Supported Output 1 Output 2 Alarm Cat. No.
Input Type: Thermocouple or RTD
— No 900-TC8RGTZ25 318.00
— Yes (1-Phase) 900-TC8RGTH1Z25 330.00
Relay Voltage (for
No 900-TC8RVGTZ25 355.00
driving SSR)
— Yes (3-Phase) 900-TC8RGTH3Z25 350.00
— No 900-TC8VGTZ25 318.00
— Yes (1-Phase) 900-TC8VGTH1Z25 329.00
100…
3 Voltage (for Triac No 900-TC8VYGTZ25 355.00
LOGIC
240V AC
driving SSR) Voltage (for
No 900-TC8VVGTZ25 355.00
driving SSR)
— Yes (3-Phase) 900-TC8VGTH3Z25 350.00
— No 900-TC8ACGTZ25 350.00
0...20 or 4...20 mA Triac No 900-TC8ACYGTZ25 382.00
Analog Output Voltage (for
No 900-TC8ACVGTZ25 382.00
driving SSR)
— No 900-TC8RGTU25 308.00
Relay
— Yes (1-Phase) 900-TC8RGTH1U25 318.00
24V Voltage (for — No 900-TC8VGTU25 308.00
3
AC/DC driving SSR) — Yes (1-Phase) 900-TC8VGTH1U25 318.00
0...20 or 4...20 mA
— No 900-TC8ACGTU25 350.00
Analog Output
Input Type: Analog Current & Voltage 0...20 and 4...20 mA 0...5, 1...5, and 0...10V DC
Relay — Yes (1-Phase) 900-TC8RABH1Z25 340.00
Relay — No 900-TC8RABZ25 330.00
Voltage (for
— Yes (1-Phase) 900-TC8VABH1Z25 340.00
driving SSR)
100… Voltage (for
3 — No 900-TC8VABZ25 330.00
240V AC driving SSR)
Voltage (for
Triac No 900-TC8VYABZ25 366.00
driving SSR)
0...20 or 4...20 mA
— No 900-TC8ACABZ25 361.00
Analog Output
A current transformer (CT) is not provided with the unit.
When the heating and cooling function or the heater burnout alarm is used, one of the relay alarm outputs can be
used as the heating or cooling output or heater burnout alarm.
Supports Heater
Power Max. No. of Burnout (Open) and
Supply Alarms Heater Short-Circuit
Voltage Supported Control Output Alarm Cat. No.
Input Type: Thermocouple or RTD
Relay Yes 1 900-TC16RGTZ25
Triac Yes 1 900-TC16YGTZ25 149,00
100… Voltage (for driving
2 Yes 1 900-TC16VGTZ25 143,00
240V AC SSR)
0...20 or 4...20 mA
No 900-TC16ACGTZ25 174,00
Analog Output
Relay Yes 1 900-TC16RGTU25 136,00
Voltage (for driving
24V Yes 1 900-TC16VGTU25 136,00
2 SSR)
AC/DC
LOGIC
0...20 or 4...20 mA
No 900-TC16ACGTU25
Analog Output
Input Type: Analog Current & Voltage 0...20 and 4...20 mA 0...5, 1...5, and 0...10V DC
Relay Yes 1 900-TC16RABZ25 143,00
Triac Yes 1 900-TC16YABZ25 149,00
100… Voltage (for driving
240V AC Yes 1 900-TC16VABZ25 143,00
SSR)
0...20 or 4...20 mA
No 900-TC16ACABZ25 187,00
2 Analog Output
Relay Yes 1 900-TC16RABU25 143,00
Voltage (for driving
24V Yes 1 900-TC16VABU25 143,00
SSR)
AC/DC
0...20 or 4...20 mA
No 900-TC16ACABU25 187,00
Analog Output
A current transformer (CT) is not provided with the unit.
When the heating and cooling function or the heater burnout alarm is used, one of the relay alarm outputs can be
used as the heating or cooling output or heater burnout alarm.
1 To implement the single-phase or three-phase heater burnout and heater short alarm function, an option module
must be inserted into the 900-TC16 controller. For a list of 900-TC16 option modules, refer to the Option Units
table. The heater burnout and heater short alarm is available by mounting the appropriate option module into
any 900-TC16 controller that supports (yes) the heater burnout (open) or heater short-circuit feature.
The Bulletin 900-TC16 can have a second ON/OFF control output (SSR) by adding an option unit to the
controller. Refer to Option Units table.
Discount Schedule RAA
Max. No. of
Power Supply Alarms Control Output RS485
Voltage Supported Type Communication Port Cat. No.
Controller with Thermocouple Support
Relay 900-TC32RTZ25 204.00
100…
1 Voltage (for driving No
240V AC 900-TC32VTZ25 204.00
SSR)
Relay 900-TC32RTU25 204.00
24V AC/DC 1 Voltage (for driving No
900-TC32VTU25 204.00
SSR)
Relay 900-TC32CRTZ25 247.00
100…
No Voltage (for driving Yes
240V AC 900-TC32CVTZ25 247.00
SSR)
Relay 900-TC32CRTU25 236.00
24V AC/DC No Voltage (for driving Yes
LOGIC
900-TC32CVTU25 236.00
SSR)
Controller with Platinum RTD Support
Relay 900-TC32RPZ25 204.00
100…
1 Voltage (for driving No
240V AC 900-TC32VPZ25 204.00
SSR)
Relay 900-TC32RPU25 204.00
24V AC/DC 1 Voltage (for driving No
900-TC32VPU25 204.00
SSR)
Relay 900-TC32CRPZ25 247.00
100…
No Voltage (for driving Yes
240V AC 900-TC32CVPZ25 247.00
SSR)
Relay 900-TC32CRPU25 236.00
24V AC/DC No Voltage (for driving Yes
900-TC32CVPU25 236.00
SSR)
If the heating/cooling function is used, ALM1 will be used for the cooling control output and so the alarm output
relay will not be available.
Cat. Nos. with a C designator (e.g., Cat. No. 900-TC32C___) include RS-485 communications, but do not have an
alarm (or cooling) output.
LOGIC
1-Phase Heater burnout
(open) and heater short-
1-Phase Heater Burnout and
circuit failure detection with 900-TC16P1V2 58.40
second voltage (SSR) output
a second control voltage
(SSR) output
® Enables direct RS-232 connection to personal computer using 900BuilderLite™ software. A Cat. No. 900-CP1X
cable or equivalent is also required.
Provides two event inputs. Allows selecting up to 4 different pre-configured set points, controller Run/Stop or
Auto/Manual mode, from 2 external inputs.
Heater burnout is not available for 0...20 or 4…20 mA analog output style 900-TC16 controllers such as the 900-
TC16AC.
To obtain 38.4 k baud rate, Series B communiation units must be used with any 900-TC8x controller catalog
number from the Product Selection table on the previous page.
Note: To obtain the free software, go to http://www.ab.com and use the A-Z Product Directory under
"Resources" to locate the Temperature Controller home page. With the Bulletin 900-TC Single-Loop
website displayed, go to the "Get Software" selection in the upper right and click on 900BuilderLite.
Follow the download instructions.
Accessory Cat. No.
Free configuration software for Enhanced Functionality Bulletin 900-TC8 and 900-TC16
900-BLDLTSW1
controllers.
trending, plus program upload/download capability for any Bulletin 900-TCx controller.
Accessory Cat. No.
900Builder™ Personal Computer Configuration Software for Bulletin
900-BLDSW1 133.00
900-TC32 Temperature Controllers (available in CD format only)
LOGIC
Rated voltage 230V AC (1+N), 400V AC (3+N) 230/400V AC, 240/415V AC
Tripping characteristic
— 30 °C
reference temperature
Rated tripping current 30, 100, 300, 500 mA —
Sensitivity AC and pulsating DC —
10 kA with 63 A gG/gL back-up fuse
Rated short circuit for up to 63 A
10 kA
capability 10 kA with 80 A gG/gL back-up fuse
for 80 A
Max. back-up fuse for 63 A gG/gL for up to 63 A
100 A gG/gL
short circuit protection 80 A gG/gL for 80 A
25 A gG/gL (25 A and 40 A devices)
Maximum back-up fuse
40 A gG/gL (63 A devices) —
for overload protection
50 A gG/gL (80 A devices)
Degree of protection IP20 IP20
Mechanical life ≥10000 changeovers ≥6000 changeovers
Mounting 35 mm hut (DIN) rail 35 mm hut (DIN) rail
-5°C…+40°C
Operating temperature -5°C…+40°C (reduction factors are required
for higher temperatures )
Wire size 1.5…35 mm2 1…25 mm2
Terminal torque 2.4 N.m ≤40 A, 3.0 N.m ≥63 A 2.4 N.m
Standards and IEC/EN 61008 IEC/EN 60889
Approvals VDE, CE CE, VDE, UL 1077, CSA 22.2 No. 235
Product Selection Page 2-68 Page 2-70
Bulletin 140F
Type MCS Fuse Holders
Available for UL Class CC or Midget Fuses, with or without blown fuse indication
Lockable in the open position
Compatible with 140M accessories
Features Compact busbar and connectors of contactors 100C and 100M
1 NO/ 1 NC Auxiliary Contact, early break NC
Provides capability for dropping out contactor before breaking current on fuse
Late make NO provides positive indication that power circuit is open
Product Selection Page 2-78
LOGIC
1492-RCD2 1492-RCD4
True IP2X finger-safe design (front)
Undelayed tripping time
Line-voltage independent tripping (suitable for residual current & additional protection)
Rated tripping current: 30, 100, 300, 500 mA
For applications in which AC and pulsating DC fault currents are likely to appear, nonselective and
non-delayed
Designed to prevent unwanted tripping caused by switching electronic circuit devices
Mounts on DIN Rail
Busbar position on top or bottom
Conditionally surge current proof 250 A
Rated Short-Circuit strength: 10 kA with 63 A gG/gL back-up fuse, 10 kA with 80 A gG/
gL back-up fuse for 80 A device
LOGIC
Standard Versions
Operating Rated Rated
Voltage, Tripping Operational
Nominal Current Current 2 poles (1 pole + neutral) 4 poles (3 poles + neutral)
[V] [mA] [A] Cat. No. Cat. No.
16 1492-RCD2A16 86.20 — —
25 1492-RCD2A25 71.50 1492-RCD4A25 94.90
30 40 1492-RCD2A40 89.80 1492-RCD4A40 117.00
63 — — 1492-RCD4A63 170.00
80 — — 1492-RCD4A80 266.00
25 1492-RCD2B25 74.10 1492-RCD4B25 97.70
100 40 1492-RCD2B40 92.50 1492-RCD4B40 122.00
63 — — 1492-RCD4B63 176.00
230/400V 16 — — 1492-RCD4C16 102.00
50 Hz 25 1492-RCD2C25 64.70 1492-RCD4C25 85.30
300 40 1492-RCD2C40 80.90 1492-RCD4C40 107.00
63 — — 1492-RCD4C63 153.00
80 — — 1492-RCD4C80 239.00
16 — — 1492-RCD4D16 96.70
25 — — 1492-RCD4D25 80.60
500 40 — — 1492-RCD4D40 101.00
63 — — 1492-RCD4D63 145.00
80 — — 1492-RCD4D80 226.00
Accessories 1492-RCD
Description Diagram Cat. No.
LOGIC
Auxiliary/Signal Alarm Contact Module
1 Auxiliary Contact switches when protective device
is operated manually or tripped electrically 96 98 12 14
Energy Limiting Design - Protects Downstream Components Better than Conventional Breakers
During Short Circuits
Field Mountable Options for Selective Applications
IP2x Finger-Protection (Front)
International Approvals - CE Marked, and Meets UL, CSA, and IEC (VDE, GL) Standards for
Worldwide Acceptance
Ratings to 480Y/277V AC @ 240/415V AC - 10 000 A Interrupt Rating
AC and DC Voltage Ratings - in One Convenient Device
A Positively Trip-Free Mechanism (Breaker Operation Cannot be Defeated by Holding the Handle in
the ON Position)
3 Trip Curves: B, C, and D
Time Delay (D Characteristic) for High Inrush Currents During Inductive Start-Ups Such as
LOGIC
LOGIC
Miniature Circuit Breakers, 3-Poles
Trip Curve C Trip Curve D
Inductive Highly Inductive
Tripping Characteristics 5…10 In 10…20 In
Continuous
Current Rating
Number of Poles (In) Ampere Cat. No. Cat. No.
1 1492-SP3C010 50.10 1492-SP3D010 63.60
2 1492-SP3C020 50.10 1492-SP3D020 63.60
4 1492-SP3C040 50.10 1492-SP3D040 63.60
6 1492-SP3C060 30.90 1492-SP3D060 39.20
10 1492-SP3C100 30.90 1492-SP3D100 39.20
13 1492-SP3C130 30.90 1492-SP3D130 39.20
16 1492-SP3C160 30.90 1492-SP3D160 39.20
20 1492-SP3C200 34.60 1492-SP3D200 43.90
25 1492-SP3C250 37.70 1492-SP3D250 47.80
32 1492-SP3C320 46.40 1492-SP3D320 74.50
40 1492-SP3C400 58.60 1492-SP3D400 74.50
50 1492-SP3C500 77.10 — —
63 1492-SP3C630 102.00 — —
For Trip Curves B visit our website or consult your local sales office.
LOGIC
loss of power and eventual D2 AC
restoration of power creates an
unsafe or unknown set of condition.
Shunt Trip Module 110…415V
Use the shunt trip module to trip the AC
1 1492-ASPA1 21.90
adjacent breaker poles from a remote (110…230V
location. DC)
The module is actuated by applying a
voltage (pickup voltage) to the trip
terminals. 12…110V
Shunt trip modules are often used in AC
1 1492-ASPA2 21.90
emergency shutdown circuits where (12…60V
multiple power circuits must be DC)
switched off from a single location.
Mounting Rails
DIN (#3) Symmetrical Rail
10 199-DR1 13.30
35 mm x 7.5 mm x 1 m long
Order must be for 10 rails or multiples of 10.
DIN Hi-Rise Symmetrical Rail, 1 m
35 mm x 7.5 mm, 57.4 mm (2.26 in.) high 2 1492-DR6 19.10
Copper-Free Aluminum
DIN Angled Hi-Rise Symmetrical Rail, 1 m
35 mm x 7.5 mm, 71.0 mm (2.80 in.) high 2 1492-DR7 22.20
Zinc-Plated, Chromated Steel
End Anchor 10 1492-EAH35 2.39
Lockout Attachment 10 1492-ASPLOA 4.14
PQ = Package Quantity
PQ = Package Quantity
Protective cover
5 1492-ASPCLPS 2.46
for unused fork termination
1 m (19
3 poles 63 1 1492-ASPCL3 35.10
devices/m)
LOGIC
(may be cut to length, not for use with accessories)
1 m (56
1 pole 40 1 1492-ACBCL1 25.10
devices/m)
2 poles (1p + 1 m (26
30 1 1492-ACBCL2 47.10
N) devices/m)
1 m (16
3 poles 30 1 1492-ACBCL3 53.40
devices/m)
PQ = Package Quantity
LOGIC
3 Pole Fuse Block 2 1492-FB3C30 34.10 1492-FB3M30 33.00
3-
Poles 3 Pole Fuse Block with 2 1492-FB3C30-L 49.90 1492-FB3M30-L 49.30
Indication
1 All major fuse brands and current ranges have been evaluated for this fuse holder. Due to the heat they generate,
the following fuses must be derated:
Ferraz Shamut ATQR 1.25 I = 0.42 A max.
Ferraz Shamut ATQR 1.40 I = 0.47 A max.
PQ = Package Quantity
Approvals
Description IEC CE Mark UL CSA Cat. No.
MCS Fuse Holder, CC - 30A Yes Yes Yes Yes 140F-D3C-C30 40.10
MCS Fuse Holder with Blown Fuse
Yes Yes Yes Yes 140F-D3C-C30L 56.30
Indication, CC - 30A
MCS Fuse Holder, Midget - 30A Yes Yes Yes Yes 140F-D3M-C30 40.10
MCS Fuse Holder with Blown Fuse
Yes Yes Yes Yes 140F-D3M-C30L 56.30
Indication, Midget - 30A
LOGIC
For additional accessories refer to contactors 100M/100-C and circuit breakers 140M.
LOGIC
Input Voltage
85…375V DC 160...375V DC 450...820V DC
Efficiency 80...90% 87...93% 89...92.5%
5, 10...12, 12, 15, 24, 48V
Output Voltage 12, 24, 36, 48V DC 24, 48V DC
DC
Rated Output Current 1.3…4.2 A 2.5…20 A 4…40 A
Operating Temperature -10…+70°C -10…+70°C -10…+70°C
Range (Tamb) >60°C with derating >60°C with derating >60°C with derating
CE, UL508, UL1950, CE, UL508, UL1950, CE, UL508, UL1950,
Approvals IEC/EN IEC/EN IEC/EN
60950, EMC 60950, EN 50178, EMC 60950, EN 50178, EMC
EN 55011 (Class B), EN 55011 (Class B),
EN 50081-1, EN 55022 (Class B), EN 55022 (Class B),
Standards EN 61000-6-2, EN 61000-6-2, EN 61000-6-2,
EN 61000-3-2 (A14) EN 61000-3-2 (A14), EN 61000-3-2 (A14),
EN 50081-1 EN 50081-1
Product Selection Page 2-81 Page 2-81 Page 2-82
88…375/ 450…780V DC
Efficiency 91.6...95% 96% ⎯
24…120V
Output Voltage 24V DC 120, 208/230V AC
Multi-tap 115…230V (50 Hz)
Rated Output Current 5…20 A 4.2 A ⎯
Operating Temperature -25…+70°C
0…50°C ⎯
Range (Tamb) >60°C with derating
CE, UL508, UL1950,
CE, UL506, NEC450, TÜV
Approvals IEC/EN UL, CSA, CE
Rheinland
60950, EN 50178, EMC
EN 55011 (Class B),
EN 55022 (Class B),
EN 50091-1-1,
EN 61000-6-2,
EN 50091-2 (Class 2)
Standards EN 61000-3-2 (A14), EN 61558
UL 1778
EN 50081-1
CSA C22.2 No. 107.3
UL 508
UL 1950
Product Selection Page 2-81 Page 2-84 Page 2-86
LOGIC
50 W
24…28V DC 2.1 A NEC Class 2 — N/A 1606-XLP50EZ 111.00
48…56V DC 1.0 A NEC Class 2 — N/A 1606-XLP50F 115.00
72 W 24…28V DC 3.0 A NEC Class 2 — N/A 1606-XLP72E 133.00
90 W 12…15V DC 8.0 A NEC Class 2 Yes Yes 1606-XLP90B 201.00
24…28V DC 4.2 A Yes 1 Yes 1606-XLP100E 156.00
100 W
48…56V DC 2.1 A Yes 1 Yes 1606-XLP100F 175.00
1606-XL Standard Single Phase
60 W 2.5 A NEC Class 2 — Yes 1606-XL60D 151.00
24V DC
120 W 5.0 A — — Yes 1606-XL120D 202.00
180 W 12…15V DC 15 A — — No 1606-XL180B 329.00
FM Class 1 — No 1606-XL240E 264.00
24…28V DC 10 A
240 W Div. 2 T3A — Yes 1606-XL240EP 303.00
48…56V DC 5.0 A — — Yes 1606-XL240FP 343.00
Active inrush
Yes 1 No 1606-XL480E 345.00
current limiting
24…28V DC 20 A — Yes 1 Yes 1606-XL480EP 424.00
480 W Remote shut
Yes 1 Yes 1606-XL480EPT 467.00
down
36…43V DC 13.3 A — Yes 1 Yes 1606-XL480GP 467.00
48…56V DC 10 A — Yes 1 No 1606-XL480F 444.00
1606-XLS Performance Single Phase
120 W 24…28V DC 5.0 A — Yes Yes 1606-XLS120E 212.00
240 W 24…28V DC 10 A — Yes Yes 1606-XLS240E 277.00
1 Single/parallel operation (inclined characteristic) selectable (jumper)
(FUSE
240 W 10 A Yes 1 Yes 1606-XL240E-3 264.00
Mode/continuou
s current), 2-
phase operation
24…28V admissible
DC
20 A — Yes 1 Yes 1606-XL480E-3 305.00
Wide input
range; overload
behavior
20 A selectable Yes 1 Yes 1606-XL480E-3W 312.00
480 W
(FUSE
Mode/continuou
s current)
48…56V Input voltage
10 A Yes 1 Yes 1606-XL480F-3H 377.00
DC 400V AC
720 W 30 A — Yes 1 Yes 1606-XL720E-3 426.00
Passive load
40 A Yes 1 Yes 1606-XL960E-3 478.00
24…28V sharing
960 W DC Active inrush
Active current
40 A current limiting; Yes 1606-XL960E-3S 565.00
sharing
output signals
1606-XLS Performance Three Phase
24…28V
480 W 20 A — Yes Yes 1606-XLS480E-3 328.00
DC
1 Single/parallel operation (inclined characteristic) selectable (jumper)
LOGIC
Vin 1 -.9V
— 16 A Redundancy — N/A 1606-XLPRED 45.30
typ
10-60 V DC
Vin -.5V Dual 1+1
— 30 A — N/A 1606-XLRED20-30 130.00
typ redundancy
Vin -.6V Single N+1
— 40 A — N/A 1606-XLRED40 115.00
typ redundancy §
1 Single/parallel operation (inclined characteristic) selectable (jumper)
To be used alongside 20 and 30 A power supplies (or smaller)
‡ Used with a pair of identical power supplies to offer N+1 redundancy
§ To be used alongside 40 A power supplies (or smaller)
Accessories
Description Cat. No.
Back of panel bracket for XL 1606-XLA 6.18
Output Operating Without Network Management Card With Network Management Card
Power Input Voltage Temperature Cat. No. Cat. No.
0…40°C 1609-U500NS 565.00 1609-U500NSC 1,110.00
115V AC
500 VA 0…50°C 1609-U500NH 735.00 1609-U500NHC 1,280.00
(325 W) 0…40°C 1609-U500ES 565.00 1609-U500ESC 1,110.00
208/230V AC
0…50°C 1609-U500EH 735.00 1609-U500EHC 1,280.00
LOGIC
Accessories
Description Output Power Cat. No.
40°C Replacement Battery 500 VA (325 W) 1609-500SBAT 100.00
50°C Replacement Battery 500 VA (325 W) 1609-500HBAT 265.00
Network Management Card 1609-NMC 555.00
Remote Start Cable 1609-RSC 37.50
LOGIC
5000 VA (3500 W) 208/230V AC 1609-P5000E 6,120.00
8000 VA (6400 W) 208/230V AC 1609-P8000E 8,290.00
10000 VA (8000 W) 208/230V AC 1609-P10000E 10,100.00
Accessories
Description Cat. No.
Network Management Card 1609-NMC 555.00
Remote Start Cable 1609-RSC 37.50
Replacement Battery 1609-PBAT 790.00
External Battery Pack 1609-PXBP 1,160.00
5000 VA CCT 1609-5000CCT 835.00
Rail Kit 1609-PRK1 180.00
LOGIC
Primary 550V (50 Hz) / 600V (60 Hz)
Secondary 24V (50 Hz)/24V (60 Hz) Secondary 110V (50 Hz)/120V (60 Hz)
Continuous VA Cat. No. Cat. No.
63 1497-A-CXJK-0-N 41.10 1497-A-CXSX-0-N 41.10
80 1497-B-CXJK-0-N 44.10 1497-B-CXSX-0-N 44.10
130 1497-C-CXJK-0-N 52.90 1497-C-CXSX-0-N 52.90
200 1497-D-CXJK-0-N 64.60 1497-D-CXSX-0-N 64.60
250 1497-E-CXJK-0-N 72.70 1497-E-CXSX-0-N 72.70
350 1497-F-CXJK-0-N 98.50 1497-F-CXSX-0-N 98.50
500 1497-G-CXJK-0-N 134.00 1497-G-CXSX-0-N 134.00
750 1497-H-CXJK-0-N 176.00 1497-H-CXSX-0-N 176.00
800 1497-J-CXJK-0-N 207.00 1497-J-CXSX-0-N 207.00
1000 1497-K-CXJK-0-N 282.00 1497-K-CXSX-0-N 282.00
1600 — — 1497-L-CXSX-0-N 411.00
2000 — — 1497-M-CXSX-0-N 499.00