Chapter 1 Summarize
Email: [email protected]

Chapter 区分)
Lisun Electronics(大标题,居中小三加粗,尽量在新一页,用
Inc. (USA)
1. Operating
Add: 445 S. Figueroainstruction
Street, Los Angeless, CA 90071, U.S.A.
(一级标题,左对齐小四加粗)
According to the requirements of CIE, IESNA and the National’s standard, this
Email: [email protected]
system is a multi-measurement mode spectrophotometer system which can realize
B-β, A-α
Lisun and
China C-γ etc through rotating lamps and lanterns.
Factory
Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China
It test
Tel: Spatial, light intensity distribution curves on any cross section (can be shown
+86-189-1799-6096
under the rectangular coordinate system or polar coordinate system), spatial
Email: [email protected]
iso-intensity curve. (正文,段首顶格左对齐 10 号,段落之间空行)
1.1 Explosive material (二级标题,左对齐五号加粗)
Lead in CFL & LED Test Instruments
According to the requirements of CIE, IESNA and the National’s standard, this
Rev. 201610001
Lisun Electronics Inc. [email protected] www.Lisungroup.com

 Introduction

WT5000 Integrated Tester for electronic ballast display parameters and curve via
super-large LCD screen without computer. It takes all the technical characteristics
and parameters, expanding analysis for envelope wave and testing for single wave
of hi-frequency are newly added function. Fully meet the input, output performance
measurement requirement for electronic ballast according to IEC60929, IEC60969,
IEC61000-3-2, GB/T15144-93, GB/T17263-1998, and other standards.

WT5000 uses the advanced 12 digital A/D converter with ultra-high speed, sampling
speed reaches as high as 10MHz. It offers a better tool for technician to research the
ballast’s mechanism and to undertake the reliability analysis by testing single wave
with high frequency.

WT5000 uses the super-large LCD screen to display the parameters and curve; it is
convenient and suitable for technology development, spot testing and business
communication. WT5000 can print data and communicate with PC, displaying all the
dates and curves in PC

 Technical Parameters
1. Characteristics
(1) Super-large color LCD screen for displaying parameters and curve,
convenient for comparison, analysis and business communication;
(2) Frequency response for testing input current up to 1MHz, suitable for
precise testing of various kind of electronic ballast;
(3) Symmetry analysis for envelope wave’s crest factor of lamp current;
(4) Sampling at ultra-high speed, dynamic analysis single frequency curve,
highest sampling frequency is up to 10MHz.

-Page 1 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com

(5) Portable with built-in chip micro-processor, particular suitable for


development and spot production;
(6) Parameters, waves and curves can be printed;
(7) Communicating with PC via RS-232, special software provided and
both Chinese version and English version are available. Run in Windows
98, Windows 2000 and Window XP with nice interface and easy to
operate
(8) Expanding analysis for envelope wave.

2. Function:

2.1 Testing input parameters


a. Measuring voltage, current, power, power factor, power net frequency,
total harmonic and 0-39 harmonic;
b. Range of basic wave frequency of voltage and current: 45Hz – 65Hz;
Range of narrow band: 45Hz – 5 kHz
Range of broad band: 45Hz – 1MHz
c. Voltage range: 10 – 300V (virtual value)
Range of current: NR: 0.010~1.500A (virtual value);WR: 0.010-
4.500A (virtual value)
Range of power: NR: 0~450.0W;WR: 0- 999.9W
Power factor range: 0.000 – 1.000

2.2 Testing stable output parameters


a. Measuring lamp voltage, lamp current, lamp power, filament
current, input cathodic current, crest factor, frequency;
b. Range of lamp voltage: 10 – 300V; Range of lamp power:
NR:0.5~200.0W WR:0.5~400.0W
c. Range of lamp current, filament current, cathodic current: NR:
0.010-0.750A, WR: 0.010-1.500A

2.3 Testing output parameters during start-up


a. Test preheats time and lamp voltage, current, filament current,
changing curve and data of imported cathodic current within 0 to
5s.
b. Range of lamp voltage: 10.0~800.0V
c. Range of lamp current, filament current and imported cathodic
current:
NR: 0.010-0.750A, WR: 0.010-1.500A

2.4 Testing preheating energy


a. testing the filament voltage and filament current TRMS, preheat
energy curves after the electronic ballast start-up 0~5second,and

-Page 2 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com

also calculate the start-up time and according to the filament


parameters(the value of the Q,P,F)depicted the preheat energy,
and compare to the actual preheat energy, qualified to judge
whether or not
b. range of filament voltage: 2-30V
c. range of filament current: 10mA-1.5A
d. range of filament power: 0.1-40W
e. Range of the preheat energy: according to the filament power and
the testing time.

3. Specifications

Items Test error Testing condition

voltage
±(0.1%reading+0.1%range
current Input wave: sine wave;
+1digit)
power Input frequency:

±(0.002+0.001/reading+1di 45~65Hz;
Power factor
git) No DC component;

frequency ±0.1%reading

harmonic(rms) ±(0.1%range+5%reading)

lamp voltage

lamp current Input wave: sine wave;


±(1 %reading+1%range+2di
Import cathodic Input frequency:
git)
current 45~65KHz;

Filament current No DC component;

Lamp power ±2.5%range

frequency ±0.5%read

 The Next Pages are the Test Report from WT5000

-Page 3 -
Electronic Ballast Test Report Page 1 of 7 Pages

Input Characteristics Test Report [Narrow Band]

Voltage Current Power Power Factor Frequency


220.2(V) 0.696(A) 83.4(W) 0.543 50.00(Hz)

Voltage
Sensitivity: 319.33 V/Div
Peak: 319.3 V
Current
Sensitivity: 1.144 A
Peak: 2.288 A
Start Phase: 64.7°
Peak Phase: 84.4°
End Phase: 102.7°

Voltage Spectrum
THD(IEC): 2.2%
H3: 0.9%
H5: 1.0%
H7: 1.1%
0 K 39 H9: 0.9%

Current Spectrum
THD(IEC): 147.2%
H3: 92.2%
H5: 79.3%
H7: 62.6%
0 K 39 H9: 44.5%

Type:Electronic Ballast Number:10


Manufacturer:Philips Lighting Co., Ltd
Temperature:25°C Humidity:65%
Test Instrument: Lisun WT5000 Electronic Ballast Analysis System
Operator: Jacky 2010-03-04 Inspector:Herry 2010-03-04
Electronic Ballast Test Report Page 2 of 7 Pages

Input Characteristics Test Report [Narrow Band] (Cont.)

Voltage: 220.2(V) Current: 0.696(A)


VCF: 1.45 ACF: 3.29
Vthd(IEC): 2.2% Athd(IEC): 147.2%
Voltage Spectrum Current Spectrum
k Rel. Abs.(V) k Rel. Abs.(A)
0 0.0% 0.1 0 0.0% 0.005
1 100.0% 220.1 1 0.2% 0.391
2 0.0% 0.0 2 0.0% 0.001
3 0.9% 1.9 3 0.2% 0.360
4 0.0% 0.0 4 0.0% 0.001
5 1.0% 2.3 5 0.1% 0.310
6 0.0% 0.0 6 0.0% 0.001
7 1.1% 2.3 7 0.1% 0.245
8 0.0% 0.0 8 0.0% 0.001
9 0.9% 2.1 9 0.1% 0.174
10 0.0% 0.0 10 0.0% 0.001
11 0.7% 1.5 11 0.0% 0.107
12 0.0% 0.0 12 0.0% 0.001
13 0.4% 0.9 13 0.0% 0.053
14 0.0% 0.0 14 0.0% 0.000
15 0.1% 0.2 15 0.0% 0.014
16 0.0% 0.0 16 0.0% 0.000
17 0.1% 0.2 17 0.0% 0.008
18 0.0% 0.0 18 0.0% 0.000
19 0.2% 0.4 19 0.0% 0.016
20 0.0% 0.0 20 0.0% 0.000
21 0.2% 0.4 21 0.0% 0.015
22 0.0% 0.0 22 0.0% 0.000
23 0.1% 0.3 23 0.0% 0.009
24 0.0% 0.0 24 0.0% 0.000
25 0.0% 0.1 25 0.0% 0.004
26 0.0% 0.0 26 0.0% 0.000
27 0.1% 0.2 27 0.0% 0.005
28 0.0% 0.0 28 0.0% 0.000
29 0.1% 0.2 29 0.0% 0.006
30 0.0% 0.0 30 0.0% 0.000
31 0.1% 0.2 31 0.0% 0.005
32 0.0% 0.0 32 0.0% 0.000
33 0.1% 0.1 33 0.0% 0.003
34 0.0% 0.0 34 0.0% 0.000
35 0.1% 0.1 35 0.0% 0.004
36 0.0% 0.0 36 0.0% 0.000
37 0.1% 0.2 37 0.0% 0.004
38 0.0% 0.0 38 0.0% 0.000
39 0.1% 0.1 39 0.0% 0.003

Type:Electronic Ballast Number:10


Manufacturer:Philips Lighting Co., Ltd
Temperature:25°C Humidity:65%
Test Instrument: Lisun WT5000 Electronic Ballast Analysis System
Operator: Jacky 2010-03-04 Inspector:Herry 2010-03-04
Electronic Ballast Test Report Page 3 of 7 Pages

Start characteristics

4.05(s) Lamp Voltage(rms)


Sensitivity: 100.00 V/Div
155.1(V)
Peak Voltage: 161.2 V

Time
Sensitivity: 500 ms/Div
Time to peak: 0.04 s

4.05(s) Filament Current (rms)


Sensitivity: 0.300 A/Div
0.153(A)
Peak Current: 0.196 A

Time
Sensitivity: 500 ms/Div
Time to peak: 0.51 s

4.05(s) Lamp Current(rms)


Sensitivity: 0.300 A/Div
0.626(A)
Peak Current: 0.628 A

Time
Sensitivity: 500 ms/Div
Time to peak: 4.06 s
Preheat time: 0.04s

4.05(s) Cathod Current(rms)


Sensitivity: 0.300 A/Div
0.551(A)
Peak Current: 0.568A

Time
Sensitivity: 500 ms/Div
Time to peak: 0.07 s

Type:Electronic Ballast Number:10


Manufacturer:Philips Lighting Co., Ltd
Temperature:25°C Humidity:65%
Test Instrument: Lisun WT5000 Electronic Ballast Analysis System
Operator: Jacky 2010-03-04 Inspector:Herry 2010-03-04
Electronic Ballast Test Report Page 4 of 7 Pages

Output

Lamp Voltage

RMS: 130.5(V)
Peak: 209.4(V)
CF: 1.60

Filament Current

RMS: 0.138(A)
Peak: 0.298(A)
CF: 2.16

Lamp Current
RMS: 0.669(A)
Peak: 0.989(A)
CF: Positive:1.48
Negative: -3.43 DHC: 132.25%
Power: 87.4 (W)
Freq.: 36.87(kHz)

Cathod Current
RMS: 0.593(A)
Peak: 0.844(A)
CF: 1.42

Type:Electronic Ballast Number:10


Manufacturer:Philips Lighting Co., Ltd
Temperature:25°C Humidity:65%
Test Instrument: Lisun WT5000 Electronic Ballast Analysis System
Operator: Jacky 2010-03-04 Inspector:Herry 2010-03-04
Electronic Ballast Test Report Page 5 of 7 Pages

Input & Output Characteristics Test Report

Input Characteristics Test Report [Narrow Band]

Voltage: 220.2(V)
VCF: 1.45
Vthd(IEC): 2.2%
Current: 0.696(A)
ACF: 3.29
Athd(IEC): 147.2%
Power: 83.4(W)
Power Factor: 0.543
Frequency: 50.00(Hz)

Output characteristics

Lamp Voltage Wave


Lamp Voltage: 130.5(V)
Filament Current: 0.138(A)
Cathod Current: 0.593(A)
Lamp Current: 0.669(A)
Lamp CurrentCF: 1.48

Power: 87.4 (W)


Freq.: 36.87(kHz)

Lamp Current Wave

Type:Electronic Ballast Number:10


Manufacturer:Philips Lighting Co., Ltd
Temperature:25°C Humidity:65%
Test Instrument: Lisun WT5000 Electronic Ballast Analysis System
Operator: Jacky 2010-03-04 Inspector:Herry 2010-03-04
Electronic Ballast Test Report Page 6 of 7 Pages

Preheat Energy

3.92(s) Filament Voltage (rms)


152.22(V) Sensitivity: 63.82 V/Div
Peak Voltage: 159.5 V

Time
Sensitivity: 500 ms/Div
Time to peak: 0.04 s

3.92(s) Filament Current (rms)


0.553(A) Sensitivity: 0.342 A/Div
Peak Current: 0.569 A

Time
Sensitivity: 500 ms/Div
Time to peak: 0.07 s

E(J)
Preheat Parameter
418.2
Pre-start Time: 0.00 s
Preheat Energy: 0.00 J
313.7

209.1
Emin = Q+P*t
104.6
(Q=7.00J, P=9.00W)
Emax Emax = F*Emin (F=1.500)
Emin
0.0 t(s)
0 1 2 3 4 5

Type:Electronic Ballast Number:10


Manufacturer:Philips Lighting Co., Ltd
Temperature:25°C Humidity:65%
Test Instrument: Lisun WT5000 Electronic Ballast Analysis System
Operator: Jacky 2010-03-04 Inspector:Herry 2010-03-04
Electronic Ballast Test Report Page 7 of 7 Pages

Hight Frequency Analysis Report

Lamp Voltage: RMS: 148.4(V) Peak: 217.5(V) CF: 1.47

Filament Current: RMS: 0.145(A) Peak: 0.312(A) CF: 2.15

Lamp Current: RMS: 0.554(A) Peak: 0.732(A) CF: 1.32

Cathod Current: RMS: 0.495(A) Peak: 0.636(A) CF: 1.286

Type:Electronic Ballast Number:10


Manufacturer:Philips Lighting Co., Ltd
Temperature:25°C Humidity:65%
Test Instrument: Lisun WT5000 Electronic Ballast Analysis System
Operator: Jacky 2010-03-04 Inspector:Herry 2010-03-04