ENEA Brasimone Plant
ENEA Brasimone Plant
ENEA Brasimone Plant
FSN-ING-PAN
Engineering Design
Thermo-Mechanical Analysis
System design ..
4
Our research infrastructures….
5
CIRCE FACILITY
6
CIRCE FACILITY
7
NACIE FACILITY
NACIE (Natural Circulation Experiment)
allows to perform experimental
campaigns with HLM in the fields of
• HLM Thermal-hydraulics;
• Fluid-dynamics;
•. Fuel Pin Bundle Investigation
Features
• Height: 8 m;
• Width: 1 m;
• Pipes O.D.: 2.5”;
• Material: Steel AISI 304;
• Working Fluid: LBE;
• HLM capacity: 1500 kg;
• Working Temperature: up to 500 °C.
8
LIFUS5 FACILITY
Discharge
LIFUS5/Mod2
THINS configuration 2012 V22
TC-S3L-01
V9
V23
Argon Ar gas Argon Argon PC-S3V-01
[High P] Water [Low P] D1
Ar supply Discharge
V20
V16
V24 V26
PC-S4V-01
Discharge
V15
V6
PC-S1V-01 LC-S1V-01
PT-S1V-05 V13
TC-S4V-01 V1 Discharge
V25
PC-S2V-01
S3
S1 - Interaction vessel
TC-S2V-02
LBE
S4 – Storage tank
PT-S1V-03 PT-S1V-02
Level
SG-S1V-03 SG-S1V-02 Gauge
LBE Housing
TC-S1V-02 TC-S1V-01
Reaction vessel S1
LT-S2V-01
S2 Pb – LBE 2'’
Water
V7
TC-S2V-01
PC-AUX-01 V11
Compressor Vacuum pump PC-AUX-02
Air circuit
Safety vessel S3
PT-S2V-06 Wa. 1/2’’
Drainage
PT-S2L-07 Drainage
V5
V19 V3 Wa. ½’’ Wa. 2’’
V4 V14
TC-S2L-01
coriolis flow meter
Experimental facility for HLM/water interaction investigations (i.e. PbLi, LBE, Pb)
Designed to operate in a wide range of conditions: up to 200 bar and 500 °C
Operated for supporting nuclear fission (i.e. LFR and HLM-ADS) and fusion technologies development
Suitable for code validation, models development, safety analysis studies, testing engineering solutions, …
9
LECOR FACILITY
MATERIALS
• Mechanical behaviour
HLM TECHNOLOGIES
11
What we do…..on Nuclear Fusion
JET
ITER HEBT
neutrons
Test
LEBT
D+ pieces
Two accelerators d-beams
n-irradiation
ECR Heat
(~1017 n/s)
source RFQ DTL exchanger
IFMIF PIE
ECR source: 155 mA, 95 keV Typical reactions: 7Li(d,2n)7Be,
6Li(d,n)7Be, 6Li(n,T)4He.
Two 175 MHz Accelerators: each 125 Footprint on target: 20cm wide x 5cm high (1 GW/m2)
mA and 40 MeV, acceleration by Radio EM pump
Frequency Quadrupoles (RFQ) and Drift Total Availability:
1270%
Tube Linacs (DTL)
Our research infrastructures….
13
IELLLO Experimental Facility
• The Integrated European Lead Lithium LOop
(IELLLO) is able to carry out:
thermo-fluid dynamic tests on mock-
up of HCLL blanket modules up to
full scale, in ITER relevant conditions;
characterization of instrumentations,
auxiliary circuits and components
relevant to lead lithium loops;
LOCA simulations on HCLL TBM mock
ups.
• IELLLO can be also coupled with the
experimental helium facility HE-FUS3. The
integrated facility, named European Breeder
Blanket Test Facility (EBBTF), is unique in
terms of size and power, allowing to test the
operation of TBM mock-ups up to full scale,
14
in ITER relevant conditions.
HE-FUS3 Experimental Facility
HE-FUS3 facility is designed to study the cooling circuit of HCPB-HCLL TBMs in ITER. It is able to carry
out experiments up to scale 1:1.
• The loop is designed to operate at the following operative modes:
long term isothermal cooling flow;
slow thermal cycling flow;
fast cold thermal shock flow;
LOCA/LOFA simulation.
- Processed fluid: He
- Design Temperature: 530 °C
- Design Pressure: 8 MPa
- He mass flow-rate: 0,2 – 1,4 kg/s
- Electrical Power installed: 1 MW
15
EBBTF Experimental Facility
• The EBBTF (European Breeder Blanket Test Facility) is an experimental facility composed by the
helium loop HE-FUS3 and the liquid metal loop IELLLO.
• IELLLO facility will be able to test small/medium/full scale HCLL TBM mock-ups in conjunction
with HE-FUS3 loop. This operation mode is called integrated, and the facility is named EBBTF.
16
EBBTF Facility
TRIEX Facility
Investigation on Tritium Extraction Systems for HCLL blanket
Removable Closing
back plate system
(bolts)
20
Our research infrastructures….
…………crosscutting
21
Mechanical Test Lab
22
Metallographic and Control Lab
23
Coolant chemistry Lab
New corrosion laboratory for the
qualification of materials in Pb/PbBi/PbLi
was created in ENEA Brasimone .
The laboratory is equipped with large
capsule for the qualification of several
samples (5/6) in one device up to 550°C
with oxygen control
N. 10 Large Capsule in order to qualified 60
samples
N. 10 small capsule with 1 sample/capsule
24
Coolant chemistry Lab
25
Coolant chemistry Lab
Pb, 480-550°C
CO= 10-9-10-8 % wt.
Pb, 480°C
CO= 10-6-10-7 % wt.
Pt-air sensors
Sensor calibration
26
CONCLUSIONS
27