UD Series
UD Series
UD Series
kW
UDC and VUDC series motors are continuously rated for S1 duty as per 4000
IS: 325 / IEC 60034-7 They are suitable for 3 phase supply, 50Hz freq. 2000
The motor enclosure is offered with Degree of protection IP 23,
providing adequate protection against dripping liquids and solid objects 0
as per IS: 4691/ IEC 60034-5 & the mounting dimensions are as per IS: 2 4 6 8 10 12 Poles
1231/ IEC 60072. 3000 1500 1000 750 600 500 RPM
Stator
To minimize the iron losses, stator stack is made up of low-loss silicon
stampings. The stator winding consists of insulated coils of high
conductivity, fiber glass covered strips. Completely taped & insulated
coils are housed in the stator slots followed by insertion of tight slot
wedges & termination of the end connections. Bearings
Carefully selected anti-friction bearing are used. These bearing are
regreased and located in bearing housing of adequate size. The grease used
Rotor is lithium based grade 3. All the motors irrespective of frame size have the
The rotor bars are made of Copper for carrying higher current to ensure bearing housing insulated to prevent the flow of shaft current as a standard
minimum deflection and stress concentrations, specially incorporated practice. (Insulated bearing can also be provided for special requirements)
strappings to make the overhang rigid to encounter stresses on account
of starting and switching for various critical applications, rotor shafts are
used of high grade steel (like EN8 or other suitable grade) with Terminal Box
Ultrasonic test. For good mechanical strength and for good current carrying capacity the
terminal studs are made from extruded brass rods, rigid welded construction
Balancing with ample size for making connections of supply cables along with pressure
Ensuring a very low vibration level enhances the life of rotor, this is relief disk in the box in case of an arching short circuit, Cable entry position
achieved through a sturdy construction and careful three stage can be changed in steps of 90 degree about the axis of terminal box. The
balancing of rotor to very high accuracy as per ISO 1940 shafts are terminal box has been certified to withstand fault level of 43kA for 0.25 secs.
subjected to stringent stage wise quality checks after fabrication &
machining. UD range comply to IEC 60034-9 for noise and IEC 60034- Accessories
14 for vibration standards. • Winding Temp. Detectors (RTD) for HT, PTC thermistor for LT.
• Bearing Temp. Detectors (BTD)
• Temp. Indicators Dial type thermometer (DTT)
End-Shields • Mounting of Vibration Probes
The end shields support the rotor on bearings & protect the winding, • Phase Segregated Terminal Box (Fault withstanding type) for HT,
with other internal parts of the machine. These are either of fabricated • Star Point Terminal Box
Mild steel or of cast iron.
Dial type thermometers (DTT) are used to monitor bearing temperature under
all conditions and commonly, mercury in steel type DTT is used (Non mercury
can also be provided for special requirements). Space heater are used to
avoid any condensation of moisture inside the motor when in idle condition.
Suitably located lifting hooks of adequate strength are provided to lift the
motor for the purpose of installation, alignment, repairs and overhauling.
Earthing terminals are provided at opposite side on stator body & also on
each terminal box. Suitable sized slip ring with large creepage distances are
mounted externally to the main enclosure on the non-drive end, for ease of
maintenance, inspection windows are also provided for monitoring the
condition of the slip ring and brushes.
Technical Specification
Shaft Height Technical
355 - 710 mmSpecification
Protection IP23
Cooling IC01A1
Rotor Constructions SR / SCR
Insulation Class H,F with VPI, RR
Standards IEC60034 / IS:325
Frame Construction Fabricated Steel
Voltage & Frequency 3.3 kv to 11kV, +/-10% & 50 Hz, +/-5%
HA
ØD
A
E C B
Type Poles A B C ØD E H HA L
UDC 450 E 2 - 10 750 1250 315 85 - 125 170 - 210 450 950 2000
UDC 500 E 2 - 10 850 1250 315 - 570 85 - 140 170 - 250 500 1050 2050 - 2450
UDC 560 E 2 - 10 950 1250 335 - 570 100 - 140 170 - 250 560 1170 2075 - 2515
UDC 560 G 2 - 10 950 1600 335 - 355 125 - 140 210 - 250 560 1170 2475 - 2915
UDC 630 F 2 - 10 1060 1400 355 - 570 125 - 160 210 - 250 630 1300 2350 - 2715
Cat. No. CG / M7 / HT / Sep09
UDC 630 H 2 - 10 1060 1800 355 - 570 140 - 160 210 - 250 630 1300 2750 - 3115
UDC 710 F 2 - 10 1180 1400 375 - 630 160 - 180 250 - 300 710 1470 2450 - 2850
UDC 710 H 2 - 10 1180 1800 375 - 630 160 - 200 300 - 350 710 1470 2850 - 3250
All dimensions are in mm
† UD800 and UD900 are also available on request
Note : Due to continuous improvements and developments, the above data is likely to be changed without prior notice.
Cat. No. CG / M7 / HT / Sep09