0% found this document useful (0 votes)
91 views20 pages

Interfrequencyhandoveroptimizationreport Coveragebased 150811061827 Lva1 App6891 PDF

This document discusses optimizing inter-frequency handovers between different carrier frequencies. It provides examples of configuring measurement events and thresholds to successfully handover a user equipment (UE) between a 10MHz signal and a 20MHz signal. Specific parameters like hysteresis values and RSRP thresholds are adjusted to control when the UE will start and stop inter-frequency measurements and trigger a handover between frequencies. Test results confirm that with the appropriate configurations, inter-frequency handovers can be performed smoothly when the UE moves between areas with different signal strengths.

Uploaded by

Murat Koc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
91 views20 pages

Interfrequencyhandoveroptimizationreport Coveragebased 150811061827 Lva1 App6891 PDF

This document discusses optimizing inter-frequency handovers between different carrier frequencies. It provides examples of configuring measurement events and thresholds to successfully handover a user equipment (UE) between a 10MHz signal and a 20MHz signal. Specific parameters like hysteresis values and RSRP thresholds are adjusted to control when the UE will start and stop inter-frequency measurements and trigger a handover between frequencies. Test results confirm that with the appropriate configurations, inter-frequency handovers can be performed smoothly when the UE moves between areas with different signal strengths.

Uploaded by

Murat Koc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

www.huawei.

com
www.huawei.com

Inter Frequency Hand Over


Optimization
Author/ Email: Ray Khastur
Version: V1.0 (20131121)
Overview
Note : Please see in full screen mode for the simulation

F1:20 MHz
F2:10 MHz
F2:10 MHz
InterFreq HO Success IntraFreq HO Success

UEUE willwill
start
start
A3A4when
whenneighbor
neighboroffset
better
become
than threshold,
better than
When
UE willUE
start
located
A2 when
inside
serving
the Building
cell became
UE will
worst
handle
thanbythreshold
20 MHz
UE on 10 MHz when threshold,
out side the Building

2
Inter Frequency
Handover Observation-1
Change Configuration
 A1
 Triggering condition: Ms – Hys >
Thresh
 Exiting condition: Ms + Hys < Thresh
 A2
 Triggering condition: Ms + Hys <
Thresh
 Exiting condition: Ms – Hys > Thresh
 A4
 Triggering condition: Mn + Ofn + Ocn
– Hys > Thresh
 Exiting condition: Mn + Ofn + Ocn +
 A1 & A2 Hys < Thresh
 Ms = Measurement Serving

 Hys = Hysteresis A1A2

 Thresh = A1 or A2 RSRP Threshold

 A4

 Mn = Measurement Neighbor

 Ofn = Frequency-specific offset for Neighbor

 Ocn = Cell-specific offset for Neighbor

 Hys = Interfreq HO Hysteresis

 Thresh = A4 RSRP Threshold 4


Default Configuration (10MHz to 20MHz)
1) When UE serving from 10
MHz with default threshold
Threshold A1 : -105
Threshold A2 : -109
Our UE will not doing any
measurement due to 10 MHz
RSRP still higher than A1
Threshold

2) We need to mapping in which 4) Change A2 Threshold to (-93


level RSRP we can start to dBm). A2 (start interfreq
search other frequency. measurement report to eNB)
3) A1 threshold change to will happen when RSRP
(-90dBm) and A1A2 hys Ms+2<-93
change to 2 dBm. Ms<-95
A1 (interfreq stop
measurement) will happen
when RSRP Ms-2>-90
Ms>-88

5
Default Configuration (20MHz to 10MHz)
When UE serving from 20 MHz
with default threshold Interfreq
HO can happen smoothly

Threshold A1 : -105
Threshold A2 : -109

6
Event A2 Monitored (10MHz to 20MHz)
When UE serving from 10 MHz
UE measurement @ -97 dBm
Threshold A2 : -93
-97+2 < -93 event A2 trigger

RSRP = -105 dBm

7
Default Configuration (10MHz to 20MHz)
5) In another Band (20 MHz) the
signal strength -94 dBm.
Threshold A4 was set to -97
dBm. Hys = 2

Mn+Ocn+Ofn-Hys > Thresh


Mn+0+0-2 > -97
Mn > -95 dBm
Event A4 will happen

8
Event A4 Monitored

When UE serving from 10 MHz


UE measurement @ -92 dBm
Threshold A4 : -97
-92+0+0-2 > -97 event A4 trigger
RSRPs = -95 dBm
happen

RSRPn = -92 dBm

9
Test Result after modification

Test Result show interfreq HO can run smoothly

10
Test Result after modification

Test Result show interfreq HO can run smoothly

11
Test Result after modification

Test Result show interfreq HO can run smoothly

12
Inter Frequency
Handover Observation-2
Proposed to Modification
 From Last Configuration The Test taken from Outside to Inside
via back lobby.
 When UE move from Outside to Inside via front lobby, we need
to adjust
A1
 A1 = -67 dBm A2
 A2 = -69 dBm

1) Event A1 will happen when


Ms-2>-67
Ms>-65
2) Event A2 wil happen when
Ms+2<-69
Ms<-71

14
Proposed to Modification
 From Last Configuration The Test taken from Outside to Inside
via back lobby.
 When UE move from Outside to Inside via front lobby, we need
to adjust
A4
 A4 = -113

3) Event A4 will happen when


Mn-Ofn-Ocn+Hys > -113
Mn > -115 dBm

15