www.huawei.
com
www.huawei.com
Inter Frequency Hand Over
Optimization
Author/ Email: Ray Khastur
Version: V1.0 (20131121)
Overview
Note : Please see in full screen mode for the simulation
F1:20 MHz
F2:10 MHz
F2:10 MHz
InterFreq HO Success IntraFreq HO Success
UEUE willwill
start
start
A3A4when
whenneighbor
neighboroffset
better
become
than threshold,
better than
When
UE willUE
start
located
A2 when
inside
serving
the Building
cell became
UE will
worst
handle
thanbythreshold
20 MHz
UE on 10 MHz when threshold,
out side the Building
2
Inter Frequency
Handover Observation-1
Change Configuration
A1
Triggering condition: Ms – Hys >
Thresh
Exiting condition: Ms + Hys < Thresh
A2
Triggering condition: Ms + Hys <
Thresh
Exiting condition: Ms – Hys > Thresh
A4
Triggering condition: Mn + Ofn + Ocn
– Hys > Thresh
Exiting condition: Mn + Ofn + Ocn +
A1 & A2 Hys < Thresh
Ms = Measurement Serving
Hys = Hysteresis A1A2
Thresh = A1 or A2 RSRP Threshold
A4
Mn = Measurement Neighbor
Ofn = Frequency-specific offset for Neighbor
Ocn = Cell-specific offset for Neighbor
Hys = Interfreq HO Hysteresis
Thresh = A4 RSRP Threshold 4
Default Configuration (10MHz to 20MHz)
1) When UE serving from 10
MHz with default threshold
Threshold A1 : -105
Threshold A2 : -109
Our UE will not doing any
measurement due to 10 MHz
RSRP still higher than A1
Threshold
2) We need to mapping in which 4) Change A2 Threshold to (-93
level RSRP we can start to dBm). A2 (start interfreq
search other frequency. measurement report to eNB)
3) A1 threshold change to will happen when RSRP
(-90dBm) and A1A2 hys Ms+2<-93
change to 2 dBm. Ms<-95
A1 (interfreq stop
measurement) will happen
when RSRP Ms-2>-90
Ms>-88
5
Default Configuration (20MHz to 10MHz)
When UE serving from 20 MHz
with default threshold Interfreq
HO can happen smoothly
Threshold A1 : -105
Threshold A2 : -109
6
Event A2 Monitored (10MHz to 20MHz)
When UE serving from 10 MHz
UE measurement @ -97 dBm
Threshold A2 : -93
-97+2 < -93 event A2 trigger
RSRP = -105 dBm
7
Default Configuration (10MHz to 20MHz)
5) In another Band (20 MHz) the
signal strength -94 dBm.
Threshold A4 was set to -97
dBm. Hys = 2
Mn+Ocn+Ofn-Hys > Thresh
Mn+0+0-2 > -97
Mn > -95 dBm
Event A4 will happen
8
Event A4 Monitored
When UE serving from 10 MHz
UE measurement @ -92 dBm
Threshold A4 : -97
-92+0+0-2 > -97 event A4 trigger
RSRPs = -95 dBm
happen
RSRPn = -92 dBm
9
Test Result after modification
Test Result show interfreq HO can run smoothly
10
Test Result after modification
Test Result show interfreq HO can run smoothly
11
Test Result after modification
Test Result show interfreq HO can run smoothly
12
Inter Frequency
Handover Observation-2
Proposed to Modification
From Last Configuration The Test taken from Outside to Inside
via back lobby.
When UE move from Outside to Inside via front lobby, we need
to adjust
A1
A1 = -67 dBm A2
A2 = -69 dBm
1) Event A1 will happen when
Ms-2>-67
Ms>-65
2) Event A2 wil happen when
Ms+2<-69
Ms<-71
14
Proposed to Modification
From Last Configuration The Test taken from Outside to Inside
via back lobby.
When UE move from Outside to Inside via front lobby, we need
to adjust
A4
A4 = -113
3) Event A4 will happen when
Mn-Ofn-Ocn+Hys > -113
Mn > -115 dBm
15
Interfreq HO from 10M to 20M Front Gateway
16
Interfreq HO from 10M to 20M Front Gateway
17
Interfreq HO from 10M to 20M Back Gateway
18
Interfreq HO from 10M to 20M Back Gateway
19