Bus Duct Catalogue
Bus Duct Catalogue
Bus Duct Catalogue
Y
VRE ÖNET
ÇE
ÝM
KALÝTE VE
IEC 60439-2 T s E
ISO
9001
14001
SÝS
TEMÝ
ME 04
www.eae.com.tr
Akcaburgaz Mahallesi,
119. Sokak, No:10 Busbar Systems
Esenyurt-Ýstanbul
Tel: 0 (212) 886 23 90 630 A.....6300 A
ATA LTD. / A.C.E./ 612 40 66
Straight Lengths 11
Elbows 12-15
Standard Components 16
Dilatasyon Modülleri 17
Panel Connections 18-20
Transformer Connections 21-22
Panel Connections 23-26
Flexibles 25
Feeder Boxes 27
Tap-off Boxes
28-33
Vertical & Horizontal Applications
34-35
Fixing Elements
36-37
Determination of Special Length
38
Joint Structure 39
Inserting "Make-up Piece" Between Two Busbars 40
EC Conformity Certificate 41
Certificates 42
Product Overview 43
3D Project Design Form 44
ELINEKX ELINEKX
Introduction Technical Features
Hybrid Insulation
The perfect design for high current busbar systems High Short-Circuit
Transportation and distribution of electric special at high current rates used to
is the "compact structure" where tin plated and insulated Endurance
be provided by paralleling many large size cables. In order to place these
with B class polyester film and epoxy coated on As there are no support
Wire Systems cables in the buildings, there were used a lot of cable trays, cable ladders,
conductors are tightly placed into the extruded points in "compact
under-floor cable channels, etc. Applications of cables, such as, fixing to cable
aluminium housing (Figure 1). structure" momentum
channels, branching, connecting, calculating distances between cables for
heat dissipation, adjusting length differences, etc. need special expert Epoxy Coated Extruded Aluminium Housing levers are not formed
workers, more time, more effort, which means more money. Even after all (Figure 1).
Conductors (Al, Cu)
above difficulties and expenses, the result is not efficient enough. For Tin plated This feature ensures high
example, you can not get energy as much and from anywhere you need. short-circuit endurance
L3
L2 (Figure 5).
L1
N
Rapid and Efficient Installation * The bolt is tightened to 83 Nm (60 lbft) using
Since it has been a must to get in the torque spanner.
accordance with the rapidly improving
building technologies of civil engineering,
the installation time was made to sink by
reducing the number of bolts on the joint
points of the busbar.
Figure 3
60
Figure 4
relocating the tap-off unit.
83Nm
Torque Spanner (60lbft)
2 3
ELINEKX
Design & Horizontal Distribution
Components List
4 Project Sample
ELINEKX
Design & Vertical Distribution
As each building's structure is different than the other for vertical Line end
h= ......
N L1 L2 L3 N L1 L2 L3
I14
a= ...... 9. Floor
h= ......
er
rri I13
e Ba
Fir
a= ...... 8. Floor
h= ......
150 150 I12
Vertical Expantion
( 70 cm. )
a= ...... 7. Floor
h= ......
I11
( h ) Height of store measured from ceiling to ceiling ( cm. )
x
B
Bo a= ...... 6. Floor
ff
p -o
Ta
h= ......
in
g- nt
Special Length Plug-in Busbar
P l u i
Po I10
g
Plu
Tap-off Point
a= ...... 5. Floor
h= ...... I9
A
I8
a= ...... 4. Floor
h= ......
t
oin
a rJ I7
sb
Bu I6
a= ...... 3. Floor
h= ......
I5
a= ...... 2. Floor
h= ......
(a
)C
eil I4
ing
thi
ck 1. Floor
n es a= ......
s(
cm
.)
h= ......
I3
Project Design
a= ...... Ground Floor
The details below should be sent to our Project & Design
h= ......
department. N
… I2
11
10 a= ...... 1. Basement
Location and dimensions of the floor penetration 9
7
Number, height and ceiling thickness of storeys. 6 I1
(a=..., h=...) 5
4 2. Basement
a= ......
Connected load for each storey. 3
2
Supply type of the vertical line (busbar or cable).
h= ......
1 Feeder side,
Enterance
cable or busbar
Basement
Please send the information to us by fax or e-mail with a sample 3. Basement
drawing like the sample (Figure 1).
Busbar System Cable System Figure 1
5
ELINEKX
Technical Characteristics
Aluminium Conductor (Al)
Rated Current In A 800 1000 1250 1350 1600 2000 2500 3200 4000 5000
Busbar Code 08 10 12 14 17 20 25 33 40 50 PE
L3
L2
Standards TS EN / DIN EN / BS EN / IEC 60439-2 L1
N
Housing Material 2,50 mm RAL 7038 epoxy polyester coated extruded aluminium housing. Voltage Drop Calculation
Voltage drop of a busbar system can be calculated
Short-circuit (1 sec) Icw kA rms 35 50 60 60 60 60 100 120 120 120
with the following formula taking into account the
Short-circuit (peak) Ip kA 73,5 105 132 132 132 132 220 264 264 264 "a" load distribution constant.
6 7
ELINEKX
Technical Characteristics
Copper Conductor (Cu)
Rated Current In A 800 1000 1250 1350 1600 2000 2500 2000 2500 3150 3600 3900 4250 5000 6300
Busbar Code 08 10 12 14 16 20 25 22 26 32 36 39 43 50 63 PE
L3
L2
Standards TS EN / DIN EN / BS EN / IEC 60439-2 L1
N
Housing Material 2,50 mm. kalýnlýðýnda ekstrüzyon aluminyum profil RAL 7038 epoksi polyester boyalý Voltage Drop Calculation
Voltage drop of a busbar system can be calculated
Short-circuit (1 sec) Icw kA rms 40 50 60 60 60 60 60 70 100 120 120 120 120 120 120
with the following formula taking into account the
Short-circuit (peak) Ip kA 84 105 132 132 132 132 132 154 220 264 264 264 264 264 264 "a" as load distribution constant.
8 9
ELINEKX
BUSBAR TYPE
Order Code System CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UTILIZATION TYPE P - Plug-in / B - Bolt-on
COMPONENT
KX A 16 5 04 B TR41
COMPONENTS
Busbar Type
Standard Length STD
Special Length X
10
ELINEKX BUSBAR TYPE
CONDUCTOR TYPE
Standard Straight Length BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UTIZILATION TYPE P - Plug-in / B - Bolt-on
COMPONENT
KX
Bolt-on
L3
L2 Bolt-on Standard - STD
L1
N Straight Length Busbar
3000
KXA - Al KXC - Cu
A
Conductor Conductor
Rated Busbar Rated Busbar
(mm)
Current Code Current Code
- - 800 08 91
800 08 1000 10 106 Special Straight Length
- - 1250 12 121
X
1000 10 1350 14 131
Special Straight
1250 12 1600 16 161 Length in (cm)
1350 14 - - 176
- - 2000 20 191
Sample Order: L3
1600 17 - - 211 L2 X
2000 20 2500 25 251 L1
2500 A, Copper, Bolt-on, IP 55, N
4 conductors, 147 cm
- - 2000 22 202
- - 2500 26 252 KXC 25504 - B - X - 147
2500 25 3150 32 312
Note:
- - 3600 36 342
Minimum Length = 35 cm
- - 3900 39 372
3200 33 4250 43 412
4000 40 5000 50 492
KX
Upwards Elbow - U
250
325
Sample Order:
3150 A, Copper, Bolt-on, IP 55,
4 conductors
L3
KXC 32504 - B - U L2
L1
N
0
25 5
32
Downwards Elbow - D
5
32
0
25
Sample Order:
325
3150 A, Copper, Bolt-on, IP 55,
250
4 conductors L3
L2
L1
KXC 32504 - B - D N
Left Elbow - L
B A
Sample Order: L3
L2
2000 A, Copper, Bolt-on, IP 55, L1
N
4 conductors
KXC 20504 - B - L
KXA - Al KXC - Cu
A B
Conductor Conductor B A
Rated Busbar Rated Busbar (mm) (mm)
Current Code Current Code
- - 800 08 267 221
800 08 1000 10 282 228 Right Elbow - R
- - 1250 12 297 235
1000 10 1350 14 307 240
A
1250 12 1600 16 337 255 Sample Order: A
1350 14 - - 352 263 B
B
2000 A, Aluminium, Bolt-on, IP 55,
- - 2000 20 367 270
4 conductors
1600 17 - - 387 280
2000 20 2500 25 427 300 L3
KXA 20504 - B - R L2
- - 2000 22 377 276 L1
N
- - 2500 26 427 301
2500 25 3150 32 487 331
- - 3600 36 517 346
- - 3900 39 547 361
3200 33 4250 43 587 381
4000 40 5000 50 667 421
5000 50 6300 63 907 541
12 The dimensions given above are minumum values. Please call us for non-standard components.
ELINEKX BUSBAR TYPE
CONDUCTOR TYPE
Elbows BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UTIZILATION TYPE P - Plug-in / B - Bolt-on
COMPONENT
KX
Left Horizontal Offset - LH
Sample Order:
B
X=60 cm, 3150 A, Copper
Bolton, IP 55, 4 conductors
KXC 32504-B-LH60 - LH
x
Note: (cm)
X=min:28 cm,
X
max: *Please see table.
Ýki adet yatay dönüþ modülü ile
ofset yapýlamayan yerlerde kullanýlýr. L3
L2
B
L1
A
N
Right Horizontal - RH
Offset
X
A
Sample Order:
B
X=60 cm, 3150 A, Copper
Bolton, IP 55, 4 conductors
KXC 32504-B-RH60 - RH
B
A
Note:
x
(cm) L3
X=min:28 cm, L2
L1
max: *Please see table. N
Ýki adet yatay dönüþ modülü ile
ofset yapýlamayan yerlerde kullanýlýr.
5
32 0
25
Upwards Vertical - UV
Offset
Sample Order:
250
KX
A
Upwards Left - K U L
B
Combined Offset
Sample Order:
3150 A, Copper
Bolt-on, IP 55, 4 conductors
Note:
L3
Y
Y=min. 30 cm L2
L1
N
0
25 5
32
KUL
Upwards Right - K U R A
Combined Offset B
Sample Order:
3200 A, Aluminium
Bolt-on, IP 55, 4 conductors
Y
Y=min. 30 cm L2
L1
N
0
25 5
32 KUR
325
Downwards Left - K D L
Combined Offset 250
Sample Order:
3150 A, Copper
Bolt-on, IP 55, 4 conductors
L3
L2
KXC 32504 - B - KDL L1
N
B
Rated Busbar Rated Busbar (mm) (mm) A
Current Code Current Code
- 06 800 08 267 221
800 08 1000 10 282 228 KDL
- - 1250 12 297 235
1000 10 1350 14 307 240
Downwards Right - K D R 5
1250 12 1600 16 337 255 32
1350 14 - - 352 263 Combined Offset 0
25
- - 2000 20 367 270 Sample Order:
1600 17 - - 387 280
3200 A, Aluminium L3
2000 20 2500 25 427 300 L2
Bolt-on, IP 55, 4 conductors
Y
KX
Left Upwards - K L U
Combined Offset
Sample Order:
3200 A, Aluminium
Bolt-on, IP 55, 4 conductors
250
325
KXA 33504 - B - KLU
Note:
Y=min. 30 cm
KLU
L3
Y
L2
L1
B
N
A
Right Upwards - K R U
Combined Offset
Sample Order:
3150 A, Copper
A
Bolt-on, IP 55, 4 conductors
B
KXC 32504 - B - KRU
L3
250
L2
Note: L1
325
Y=min. 30 cm N
Y
KRU
Left Downwards - K L D
Combined Offset
Sample Order: Y
3200 A, Aluminium
Bolt-on, IP 55, 4 conductors
325
L2
B
(mm) (mm) L1
Current Code Current Code N
- - 800 08 267 221
KLD
800 08 1000 10 282 228
- - 1250 12 297 235
1000 10 1350 14 307 240
Right Downwards - K R D
1250 12 1600 16 337 255
Combined Offset
1350 14 - - 352 263
- - 2000 20 367 270 Sample Order:
B A
KX
Reduction Reduction - RD
Is use to change the busbar cross section. Reduced
Sample Order: Busbar Current
0
0
7
Conductor Bolt-on, IP 55, 4 conductors
Rated Reduced Busbar Current KXA 20504 - B - RD17
Current 08 10 12 14 17 20 25 33 40
5
2
2
1000 - - - - - - - -
1250 - - - - - - -
5
7
1350 - - - - - - -
4
L3
1600 - - - - - - - L2
L1
2000 - - - - - - - N
2500 - - - - - - -
3200 - - - - - - -
4000 - - - - - - -
5000 - - - - - - -
A
Rated Reduced Busbar Current
B
2500 A, Copper, Bolt-on,
C
Current 08 10 12 14 16 20 25 22 26 32 36 39 43 50
1000 - - - - - - - - - - - - - IP 55, 4 conductors
1250 - - - - - - - - - - - -
KXC 25504 - B - TYR
1350 - - - - - - - - - - - -
1600 - - - - - - - - - - - - L3
2000 - - - - - - - - - - - - L2
L1
2500 - - - - - - - - - - - - N
2000 - - - - - - - - - - - -
2500 - - - - - - - - - - - -
3150 - - - - - - - - - - - -
3600 - - - - - - - - - - - -
3900 - - - - - - - - - - - -
4250 - - - - - - - - - - - -
5000 - - - - - - - - - - - - Left Side Feeder "T" - T Y L
6300 - - - - - - - - - - - -
B A
Sample Order:
C
16 Please call us for non-standard components. The dimensions given above are minumum values.
ELINEKX BUSBAR TYPE
CONDUCTOR TYPE
Expansions BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UTIZILATION TYPE P - Plug-in / B - Bolt-on
COMPONENT
KX
00
12
Attention!
The total length of the module should be adjusted
to 1200 mm. after installation.
0
70
L3
L2
L1
N
End Closer - S 1 1
Sample Order:
2500 A, Copper, Bolt-on, IP 55, L3
L2
4 conductors
5
L1
2
2
N
KXC 25504 - B - S11
Please call us for non-standard components. The dimensions given above are minumum values.
17
ELINEKX BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
Panel Connections PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UTIZILATION TYPE P - Plug-in / B - Bolt-on
COMPONENT
KX
Sample Order:
225
325
Sample Order:
3600 A, Copper, Bolt-on,4 conductors
150
325
250
Downwards Panel -PD20
Connection
275
Panel Feeder
200
Sample Order:
150
18
ELINEKX BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
Busbar&Panel Connections PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UTIZILATION TYPE P - Plug-in / B - Bolt-on
COMPONENT
KX
325
250
Upwards Busbar -PU21
Connection
275
200
Busbar Feeder
Sample Order:
150
325
250
Connection
200
Busbar Feeder
Sample Order:
150
L3
100 100 100 4250 A, Copper, Bolt-on,4 conductors L2
for Busbar Feeder L1
PD21
N
KXC 43504 - B - PD21
A
B Right Panel - P R30
Connection
A-125
B-125
Panel Feeder
Sample Order:
150
N
2500 A, Copper, Bolt-on,4 conductors L1
100 100 100 for Panel Feeder
PR30 L2
L3
KXC 25504 - B - PR30
A
B Left Panel - P L30
Connection
A-125
B-125
Panel Feeder
Sample Order:
150
KX
A
B
Right Panel - PR 31
Connection
A-125
B-125
Busbar Feeder
Sample Order:
150
L3
100 100 100 2500 A, Copper, Bolt-on,4 conductors
L2
for Busbar Feeder
L1
KXC 25504 - B - PR31 PR31 N
A
Left Panel - PL 31
B
Connection
Busbar Feeder
A-125
B-125
Sample Order:
2500 A, Copper, Bolt-on,4 conductors
150
N
100 100 100 for Busbar Feeder L1
L2
KXC 25504 - B - PL31 PL31
L3
860
Panel Connection - P 40
Panel Feeder
Sample Order:
min. 3150 A, Copper, Bolt-on,4 conductors
165 165 165 110
for Panel Feeder
L3
KXC 32504 - B - P40 L2 N
L1 L1
N L2
P40 L3
20 Please call us for non-standard components. The dimensions given above are minumum values.
ELINEKX BUSBAR TYPE
CONDUCTOR TYPE
Transformer Connections BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UTIZILATION TYPE P - Plug-in / B - Bolt-on
COMPONENT
KX
Transformer - T R11
Connection
Sample Order:
2500 A, Aluminium, Bolt-on, 4 conductors
225
N
L1
150
L3
L2 L2
100 100 100
L3 L1
TR11 N
325
Upwards - T U21
250 Transformer Connection
Sample Order:
2500 A, Copper, Bolt-on, 4 conductors
275
200
N
L1
150
L2
100 100 100 TU21 L3
L3
L2
150
L1
100 100 100 TD21 N
Please call us for non-standard components. The dimensions given above are minumum values.
21
ELINEKX BUSBAR TYPE
CONDUCTOR TYPE
Transformer Connections BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UTIZILATION TYPE P - Plug-in / B - Bolt-on
COMPONENT
KX
Transformer - T R41
Connection
N Sample Order:
200
0 in.
L1 L3 m 0
2500 A, Copper, Bolt-on, 4 conductors 1 1
L1 0
67
L3 N
0
n. 29
mi
0
25
TR41
150
Transformer - T R61
Connection
0
200 N n.
Sample Order: mi 0
11
L1 70
6
3600 A, Copper, Bolt-on,
4 conductors 0
67
L2
KXC 36504 - B - TR61
0
29 225
L3 150
150
min.
100
TR61
For transformer and panel connection
applications EAE design and planning
department can prepare your projects
upon request. Right Transformer - T R51
Connection
For the design, the following information is
required; Sample Order:
22 Please call us for non-standard components. The dimensions given above are minumum values.
ELINEKX
Panel and Transformer Connection Units
Note:
No flange supplied with transformer connection units.
150
150
150
150
23
23
23
23
23
Ø14 Ø14 Ø14 Ø14 Ø14
20 27,5 40 15 40 20 40 40 15
40 55 70 80 110
150
150
150
150
150
23
23
23
23
23
KXA 25
KXC 26 KXC 32 KXC 36 KXC 39
150
150
150
150
23
23
23
23
20 40 40 20 15 40 40 40 40 15 22,5 40 40 40 40 22,5 30 40 40 40 40 30
200 260 290 320
150
150
23
23
23
20 40 40 40 40 40 40 20 20 40 40 40 40 40 40 40 40 20 20 40 40 40 40 40 40 40 40 40 40 40 40 20
360 440 680
23
ELINEKX
Panel Connections
Connection Equipment
Description Code
M 10 x 50 Bolt 01505
M 10 x 60 Bolt 01506
M10 Steel Nut 01445
M10 Washer 01424 5
KXA - Al Order KXC - Cu Order Conductor KXA - Al Order KXC - Cu Order Conductor
Conductor Code Conductor Code Size Conductor Code Conductor Code Size
Rated Busbar (each piece) Rated Busbar (each piece) Rated Busbar (each piece) Rated Busbar (each piece)
Current Code Current Code Current Code Current Code
- - - 2000 22 09387 2(6x55) - - - 2000 22 12011 2(6x55)
- - - 2500 26 06988 2(6x80) - - - 2500 26 12013 2(6x80)
2500 25 09070 3150 32 09069 2(6x110) 2500 25 12014 3150 32 12015 2(6x110)
- - - 3600 36 09117 2(6x125) - - - 3600 36 12017 2(6x125)
- - - 3900 39 09175 2(6x140) - - - 3900 39 12019 2(6x140)
3200 33 05691 4250 43 05689 2(6x160) 3200 33 12020 4250 43 12021 2(6x160)
4000 40 05791 5000 50 05789 2(6x200) 4000 40 12022 5000 50 12023 2(6x200)
5000 50 09512 6300 63 09511 3(6x200) 5000 50 12024 6300 63 12025 3(6x200)
Ø 14
Ø 14 Ø 14
56
145
40
23
95 27,5 40 80 40 20 40 40 70 40 40 15
150 200 260
Ø 14
Ø 14
56
145
40
23
40 40 85 40 40 22,5 40 40 100 40 40 30
290 320
145
40
23
40 40 40 80 40 40 40 20 40 40 40 40 80 40 40 40 40 20
360 440
KXA 50 KXA 50
KXC 63 Ø 14 Ø 14 KXC 63
26
56
145
40
20
23
40 40 40 40 80 40 40 40 40 80 40 40 40 40
680
24
ELINEKX
Flexible & Panel Connections
Sample Connection (1)
Sample Connection Types
245
5
245
10
10
ø=.....mm
KX
Flange Dimensions
Panel Connection Units are supplied with suitable flange as standard.
Panel
Panel
Connection
Connection Flange
N Flange PE PE
L1
L2 Housing Housing
L3
PE
PE L3 L2 L1 N L3 L2 L1 N
B
A
100
Ø7
12,5
26
ELINEKX BUSBAR TYPE
CONDUCTOR TYPE
Feeder Boxes BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UTIZILATION TYPE P - Plug-in / B - Bolt-on
COMPONENT
Busbar Cable
Type
Housing Type Gland Plate
Feeder Box - B 1 0
PE
L3
Sample Order: L2
1 L1
3200 A, Aluminium, Bolt-on N
4 conductors
B10
Feeder Box - B 1 1
Sample Order:
PE
L3
L2
L1
N
B11
Sample Order:
PE
L3
2500 A, Aluminium, Bolt-on, 4 conductors L2
Ampere Ratings KXA 25504 - B - BO L1
N
Locking Point
28 29
ELINEKX RATED CURRENT
BUSBAR TYPE
BOX TYPE
Bolt on- B
Plug in- P
Tap-off Boxes PROTECTION 160 A-16
250 A-25
DEGREE 400 A-40
with Fused Switches (Bolt-on-KXB) CONDUCTOR IP-55-5 630 A-63
4-0
5-1
CABLE GLAND PLATES
KX
Cable Gland Plates
A
Sheet M32 RP1 25 KX B 1 650
KX B 2 550
C
KX B 4 050
Sheet M40 RP2 32 KX B 6 350 e
at
sý
Pl
nd ka
yö Pal
n d s)
(3 or
la e
k
Ra
Sheet Special RP3 63 G sid
Sample Order: b le 3
n L3 2
Ca (o L 1
Bolt-on / 630 A / IP-55 / L
N
AL 2xSpecial RP4 63 4 conductors
KXB 6350
AL 4xM25 RP5 18
AL 4xM32 RP6 25
KX B 1 651
50
KX B 2 551
AL 4xM40 RP7 32
KX B 4 051
KX B 6 351
AL 8xM32 RP8 25
Sample Order:
Bolt-on / 630 A / IP-55 /
5 conductors 30 A 30
KXB 6351
Notes:
Max. External
Tap-off A B C D Fuse Standard Gland
Diameter of Cable
Boxes (mm) (mm) (mm) (mm) Size Gland Type
Cros-section
KXB 16 600 300 200 170 NH00 RP2 M25 Ø 18
KXB 25 750 380 240 265 NH 1 RP3 M32 Ø 26
KXB 40 850 420 255 265 NH 2 RP4 M40 Ø 33
KXB 63 850 420 255 265 NH 3 RP4 M50 Ø 39
M63 Ø 45
Special for EAE Ø 60
Tap-off boxes can be equipped with any brand of
switches, circuit breakers and etc.
A
Sheet M32 RP1 25 KX P 1 650
KX P 2 550
C
KX P 4 050
Sheet M40 RP2 32 KX P 5 050 e
at
ý
Pl
as
nd ak
y ö Pl
nd )
la des
(3 or
k
Ra
G si
Sheet Special RP3 63 Sample Order: e
bl n 3
a
C ( o
Plug-in / 400 A / IP-55 /
L3 2
4 conductors L 1
AL 2xSpecial RP4 63 L
N
KXP 4050
AL 4xM25 RP5 18
AL 4xM32 RP6 25
50
KX P 1 651
KX P 2 551
AL 4xM40 RP7 32
KX P 4 051
KX P 5 051
AL 8xM32 RP8 25
Sample Order:
Plug-in / 500 A / IP-55 /
5 conductors 30 A 30
KXP 5051
Notes:
Max. External
Tap-off A B C D Fuse Standard Gland
Diameter of Cable
Boxes (mm) (mm) (mm) (mm) Size Gland Type
Cros-section
KXP 16 520 300 210 195 NH00 RP2 M25 Ø 18
KXP 25 670 380 270 310 NH 1 RP3 M32 Ø 26
KXP 40 750 420 300 285 NH 2 RP4 M40 Ø 33
KXP 63 750 420 300 285 NH 3 RP4 M50 Ø 39
M63 Ø 45
Special for EAE Ø 60
Tap-off boxes can be equipped with any brand of
switches, circuit breakers and etc.
Please call us for non-standard tap-off boxes and detailed information.
31
ELINEKX
Product Overview 630A ... 6300A COMPACT BUSBAR
PRODUCT OVERVIEW (E-LINE KX)
1- Standards & Certification:
-Busbar system shall be designed and manufactured as per IEC 60439-2 standard. Each busbar rating shall have a seperate type test certificate from an independent internationally accredited laborotory.
-Short-circuit tests shall follow the same standard procedure. Type test certificate shall be also available. Busbar systems shall be manufactured upon the standards and criteria of the test certification. Busbar
systems shall have the “Minimum Duration of 6 Hours on Fire Certification” upon the IEC 60331 Standard.
-The tests below are necessary for each busbar current rating seperately from an independent internationally accredited laborotory upon the IEC 60439-2 Standard:
a) Temperature Rise Limits b) Dielectrical Features c) Short-circuit Duration d) Effectiveness of Protection Circuit e)Clearances and Creepage Distances f) Mechanical Operation g) Protection Degree h)
Electrical Characteristics i) Structural Duration j) Crushing Resistance k) Resistance of Insulation Material to Abnormal Heat l) Fire Barrier
- Busbar system shall have CE sign.
-Manufacturing facility of busbar systems shall have ISO 9001 and ISO 14001 certification.
-Each product shall have a “Type Label”, which indicates the brand, type of the unit, number of conductors and electrical details.
2- General Structure of Products
-Busbar system shall have “Sandwich-Compact” structure. Aluminium or Copper conductors shall be tin plated along the entire length upon the wire configuration and required number, which are described in
the statements below. Housing shall be made of termically strengthened extruded aluminium profile, which shall be RAL7038-Electrostatic painted. Protection degree shall be IP55.
43
ELINEKX RATED CURRENT
BUSBAR TYPE
BOX TYPE
Bolt on- B
Plug in- P
Tap-off Boxes PROTECTION DEGREE
IP-55-5
160 A-16
250 A-25
CONDUCTOR 400 A-40
for MCCB's (KXB) 4 Ýletken-0
5 Ýletken-1
630 A-63
800 A-80
1000 A-10
SWITCH TYPE M- MCCB / B- Empty
CABLE GLAND PLATES
Cable Gland Plates KX
B
A
KX B 1 6 5 0 - M1
Sheet M40 RP2 32
KX B 2 5 5 0 - M1
C
KX B 4 0 5 0 - M1
Sheet Special RP3 63 KX B 6 3 5 0 - M1
Sample Order:
AL 2xSpecial RP4 63
Bolt-on / 630 A / IP-55 / e
at
4 conductors, empty tap-off box Pl
n d s)
AL 4xM25 RP5 18 L3 2 a e
KXB 6350 - B1
L 1 Gl s i d
L le 3
N b n
Ca ( o
AL 4xM32 RP6 25
KX B 1 6 5 1 - B1
KX B 2 5 5 1 - B1
KX B 4 0 5 1 - B1
AL 4xM40 RP7 32 KX B 6 3 5 1 - B1
50
KX B 1 6 5 1 - M1
AL 8xM32 RP8 25 KX B 2 5 5 1 - M1
KX B 4 0 5 1 - M1
KX B 6 3 5 1 - M1
Special Cable Gland Plates
Sample Order:
Cable Order Inner
Mat. Gland Type Code Diameter Bolt-on / 630 A / IP-55 /
5 conductors, empty tap-off box
(mm) 30 A 30
Sheet ---- RPK0 ---- KXB 6351 - B1
KXB 8050 - B1
Tap-off A B C *D Standard
Boxes (mm) (mm) (mm) (mm) Gland
A
Sheet M40 RP2 32
KX P 1 6 5 0 - M1
KX P 2 5 5 0 - M1
C
Sheet Special RP3 63 KX P 4 0 5 0 - M1
KX P 6 3 5 0 - M1
AL 2xSpecial RP4 63 Sample Order:
a te
Pl
Plug-in / 400 A / IP-55 / n d s)
la e
AL 4xM25 RP5 18 4 conductors, empty tap-off box G sid
L3 2 b le 3
L 1 n
KXP 4050 - B1 L Ca ( o
N
AL 4xM32 RP6 25
50
AL 4xM40 RP7 32
AL 8xM32 RP8 25
KXP 4051 - B1
Tap-off A B C *D Standard
Boxes (mm) (mm) (mm) (mm) Gland
Max. External
Gland
KXP 16 520 300 250 150 RPK3 Diameter of Cable
Type
KXP 25 520 300 250 150 RPK4 Cros-section
KXP 40 700 300 250 255 RP4 M25 Ø 18
KXP 63 700 300 250 255 RP4 M32 Ø 26
M40 Ø 33
* D value varies as per the used switch. M50 Ø 39
M63 Ø 45
* Tap-off boxes can be equipped with any Special for EAE Ø 60
brand of MCCB's.
N L1 L2 L3 N L1 L2 L3
CEILING
FLOOR CONCRETE
100
L3
L2
L1
N
100
200
WALL
VERTICAL EXPANSION
COMPONENT
FIGURE-1 HORIZONTAL POSITION
CEILING
100
BUSBAR-1 L3
L2
L1
N
100
DUVAR
WALL
BUSBAR-2 L3
L2
L1
N
100
PLUG-IN BUSBAR
FIGURE-2 HORIZONTAL POSITION
CEILING
100
FLOOR CONCRETE
BUSBAR-1
BUSBAR-2
WALL
200
100 100
N L1 L2 L3 N L1 L2 L3
FIGURE-3 VERTICAL POSITION All measures are given in mm. FIGURE-4 RISER LOCATING MEASURES (VERTICAL)
34
ELINEKX
Vertical and Horizontal Busbar Applications
CEILING
STRING CEILING
STRING
20
100
BUSBAR (VERTICAL POSITION) L3
L2
L1 BUSBAR (HORIZONTAL POSITION)
N
N L1L2 L3
FIGURE-5 STRING CROSSING VERTICAL POSITION FIGURE-6 STRING CROSSING HORIZONTAL POSITION
WALL
WALL
200 (min.)
HOLE
HOLE
BUSBAR BUSBAR
FIGURE-7 STANDARD WALL CROSSING FIGURE-8 SAMPLE WALL CROSSING WITH FIRE BARRIER
N L1 L2 L3 N L1 L2 L3
150 200
WALL
TAP-OFF
BOXES
FIGURE-9 RISER LOCATING MEASURES (HORIZONTAL) All measures are given in mm.
35
ELINEKX ORDER CODE
LENGTH L (mm)
Fixing Elements
Supports Al Cu Order
L
Conductor Conductor Code
KX UT FIXING SET Rated Busbar Rated Busbar (mm)
Current Code Current Code
- - 800 08 250 50161
800 08 1000 10 300 50162
- - 1250 12 300 50162
1000 10 1350 14 300 50162
1250 12 1600 16 350 72597
1350 14 - - 350 72597
- - 2000 20 350 72597
1600 17 - - 400 72589
2000 20 2500 25 400 72589
- - 2000 22 350 72597
- - 2500 26 400 72589
2500 25 3150 32 500 72581
- - 3600 36 500 72581
- - 3900 39 550 72575
3200 33 4250 43 600 72573
4000 40 5000 50 650 72571
5000 50 6300 63 900 50163
Description L Code
IDD 105 155 (mm)
Fixing Elements
Supports Description L
(mm) Code
Supports
UAS-K5
Threaded Threaded Description L Code
(mm)
Rod Rod
L UAS-K5 SUPPORT (1) 200 67127S
UAS-K5 SUPPORT (2) 250 67126S
UAS-K5 SUPPORT (3) 300 67125S
50
50
UAS-K5 SUPPORT (4) 350 67124S
5
UAS-K5
UAS-K5 SUPPORT (5) 400 67123S
UAS-K5 SUPPORT (6) 500 67122S
UAS-K5 SUPPORT (7) 600 67121S
UAS-K5 SUPPORT (8) 700 67120S
UAS-K5 SUPPORT (9) 1100 67119S
L
Connection Units
Description L Code
(mm)
Threaded
Rod BRA 12-05 Threaded Rod (M10) 500 99356
BRA 12-10 Threaded Rod (M10) 1000 98876
Extension BRA 14-05 Threaded Rod (M12) 500 98706
Unit BRA 14-10 Threaded Rod (M12) 1000 98942
BRA 13 Extension Unit (M10) - 98874
Diameter of the
Steel Dowel hole to be drilled BRA 13 Extension Unit (M12) - 98696
M10.....Ø14 BRA 9 Steel Dowel (M10) - 98703
M12.....Ø16 BRA 9 Steel Dowel (M12) - 98702
Steel Nut M10 Steel Nut - 01445
M12 Steel Nut - 02231
38
ELINEKX
Joint Structure
5 12 13
7
1 3
10
2
11 6
8
Figure 5
Figure 1
Block Joint
Figure 6
1 2 2a
Alignment Pin
2a
2a
1- Remove Alignment Pin on the busbar, without block 2- Insert the piece aligning conductors correctly. Fix back the
joint. Alignment pin.
3 4
3a
3a
3- Make sure busbar piece is aligned according to alignment pin. 4- Fix one of the joint cover to stabilize joint. Apply
83Nm to the main bolt.
5 6
1
First
Torque: 4
(20-30Nm)
3
2
Final
Torque: 1
(83Nm) 4
3
2
5- If there are more than one 6- Fix the remaning joint cover.
bolt for the same phase, bolts Joint installation is completed.
shall be tighten by hand
approximately 20-30Nm as per Note: If the last joint cover can not be fixed properly and easily, it
above sequence, then 83Nm shows that physical alignment is not done properly. Release the
shall be applied at final torque bolts and repeat above applications from figure-4 with the same
with the same sequence. sequence.
Please check related installation manuel for details.
40
ELINEKX
Directive
EC DECLARATION OF CONFORMITY
According to EC - Directive
This is to attest, under our sole responsibility, that the aforementioned products conforms with
the regulations and guidelines of the following standards.
Tests
1- Temperature-rise Limits 7- Degree of Protection
2- Dielectric Properties 8- Electrical Characteristics
3- Short-circuit Strength 9- Structural Strength
E L E K T R Ý K
4- Effectiveness of The Protective Circuit
5- Clearances and Creepage Distances
10- Crushing Resistance
11- Resistance of Insulating Materials to Abnormal Heat
6- Mechanical Operation 12- Fire Barrier
02.01.2008
41
ELINEKX
Certificate
42
44
Component List
Company :
Project :
Project No :
Name :
Date :
Signature :
Prepared by
E L E K T R Ý K
43