0% found this document useful (0 votes)
35 views2 pages

Turbo Lab 1 Data

The document contains test results from experiments run at different frequencies, pressures, flow rates, and impeller speeds. It includes two graphs: one showing efficiency increasing with impeller speed up to a point then decreasing, and another showing water flow rate increasing linearly with impeller speed. The data suggests tests were conducted on a pump or similar device to analyze the relationships between operational parameters.

Uploaded by

Weii Kangg
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
35 views2 pages

Turbo Lab 1 Data

The document contains test results from experiments run at different frequencies, pressures, flow rates, and impeller speeds. It includes two graphs: one showing efficiency increasing with impeller speed up to a point then decreasing, and another showing water flow rate increasing linearly with impeller speed. The data suggests tests were conducted on a pump or similar device to analyze the relationships between operational parameters.

Uploaded by

Weii Kangg
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Differen

Flow Power
Frequen Pressure Power, Flow tial Efficien Speed
Rate, Output,
cy ,hz , bar watt Rate,m3 Pressure cy, % (rpm)
L/min W
, Kpa
8 10 0 70 0.000167 11.036 1.839333 2.627619 475.2
11 17 0 82 0.000283 11.036 3.126867 3.813252 650.6
16 24 0 96 0.0004 11.036 4.4144 4.598333 938
17 28 0 131 0.000467 11.036 5.150133 3.931399 991
20 33 0 151 0.00055 11.036 6.0698 4.019735 1150
23 38 0 183 0.000633 11.036 6.989467 3.819381 1324
26 43 0.1 236 0.000717 11.036 7.909133 3.351328 1498
30 48 0.1 311 0.0008 11.036 8.8288 2.838842 1730

Water Flow Rate v


100

water flow rate, m3/3(x105)


80

60

40

20

0
400 600 800 100
Impelle
Efficiency vs Impeller Speed
Efficiency, %
5

4
16.66667
3
28.33333
40 2
46.66667
1
55
63.33333 0
400 600 800 1000 1200 1400 1600 1800
71.66667
80 Impeller Speed, rpm

Water Flow Rate vs Impeller Speed


100

80

60

40

20

0
400 600 800 1000 1200 1400 1600 1800
Impeller speed, rpm

You might also like