AEROFLOW CONTROL VALVE

Innovative Technology for the 21st Century


LINEAR

The Aeroflow control valve family represents an integrated valve solution for the 21st Century ... and beyond. Not a compromise or re-
packaging of old valve technologies. The Aeroflow valve concept integrates proven state-of-the-art design in aerodynamic/ hydrody-
namic flow, field proven materials, digital positioning, and “smart” valve technology, with a modular design concept. The sum benefit
of Aeroflow’s technological advances is simply the most accurate, reliable control valve product line available in the world today.

CLASS 150 - 4500#


Typical Globe Style Body
w/Pilot Balanced Trim

Typical Angle Style Body

2
6

- 58 -
AEROFLOW CONTROL VALVE
Solution-Engineered Features for Demanding Applications

LINEAR
1. Aerodynamic Flow Control Vanes
• Integrally cast into the inlet and 0utlet
• Profiles flow to reduce turbulence
• Evenly distributes flow around the cage
• Reduces noise generated in the valve
2. Zero Leakage Tight Shut-off
• Exceeds ANSI Class VI shutoff
• Metal to metal seat and pilot balanced plug design
• Zero cc/min without oversized actuators
3. Custom Characterized Trim Options
• C3 Combination Characterized Cage – Combines high rangeability,
cavitation protection and low noise in one valve
• Mini P Multi Stage Trim – Designed for low-flow, high ∆P,
cavitating service with tight shutoff
• Les-Sonic Cage – Provide up to a 25 dBA noise reduction
• Les-CAV Multi Stage Cage – Up to five stages control for pressure
drops to 4000 PSI (276 BAR)
• Micro Taper Trim – Specially designed trim for very fine control in
low-flow/ high ∆P applications
4. Tri-Sheer Protected Seat Design
• Prevents high velocity erosion at opening and closing
• Provides a five-stage pressure drop near the seating position
• Prevents particle impingement on the seating surfaces since they
are withdrawn from the direct flow path before flow commences
• For LES-CAV cages only
5. “Smart Valve” Capability
• Optional inlet and outlet pressure taps provide accurate,
stable pressure measurements required by today’s “smart”
instrument action
6. Quick Change Trim Design (ANSI 900 and above)
• Seat retention and gasket loading are designed for reliability
and ease of maintenance
7. Hung Cage Design (ANSI 900 and above)
• Suspended Trim Cage eliminates damaging effects
of thermal expansion
• Cage is free to expand and contract with temperature changes
8. Oversized Outlet Connection
• Aeroflow Valves can be supplied with a larger outlet connection
than the valve body size
9. Parts Interchangeability
• All parts interchangeable between globe and angle style bodies
• Reduces parts inventory
• Reduces maintenance training

- 59 -
AEROFLOW TRIM OPTIONS
MODULAR TRIM
LINEAR

Aeroflow trim design allows you to choose the ideal tion to give you the best possible solution to your spe-
cost/performance combination for each application. cific flow control application. In addition, as shown at
All trim modules are 100% field interchangeable pro- the bottom of this page, we can also offer customized
viding extraordinary flexibility and value. Any of the trim sets for specific severe service applications where
cage throttling designs shown below can be combined fine control of low flows and high differential pressures
with any of the characterized cages shown in this sec- is a critical part to your operation.

CAGE THROTTLING DESIGNS


PILOT BALANCED (PB) BAL. LOW-TEMP (BL)

-20ºF — 1050ºF -20ºF — 500ºF


-29ºC — 565ºC -29ºC — 260ºC
Class IV/V/Zero Class IV/V

BAL. HIGH-TEMP (BH) UNBALANCED (UBC) T2

-20ºF — 1050ºF -20ºF — 1050ºF -20ºF — 1050ºF


-29ºC — 565ºC -29ºC — 565ºC -29ºC — 565ºC
Class III Class IV/V/Zero Class IV/V/Zero

- 60 -
AEROFLOW TRIM OPTIONS
CUSTOM CHARACTERIZED CONTROL

LINEAR
Standard LesSonic Cage
Cage (Noise Control)

LesCav Cage C3 Cage


(Cavitation Control) (Range Control)

CUSTOM TRIM SET OPTIONS


UNBALANCED (UBP) MICROTAPER® (MT) MINI-P
For Fine Control on For Staged Low Flow/
Low Flow/ High ∆P Cavitating
High ∆P Service Service

-20ºF — 1050ºF
-29ºC — 565ºC
Class IV/V/Zero
-20ºF — 1050ºF -20ºF — 800ºF
-29ºC — 565ºC -29ºC — 427ºC
Class IV/V/Zero Class IV/V/Zero

- 61 -
AEROFLOW CV TABLES
UNBALANCED PLUG THROTTLING (UBP) Cv Table
ANSI Class 150 – 2500
LINEAR

Linear and Equal %


Valve Stem Seat
Size Stroke Dia. Dia. Min. Cv Max.
in (DN) in (mm) in (mm) in (mm) Controllable Cv

1 (25) 1 (25) 0.75 (20) 1.00 (25) 0.2 16

1.5 (40) 1 (25) 0.75 (20) 1.50 (40) 0.2 30

2 (50) 1.5 (40) 0.75 (20) 2.25 (57) 0.3 57

3 (80) 2 (50) 0.75 (20) 3.00 (80) 0.4 120

CAGE THROTTLING (UBC, BL, BH, PB, T2) Cv Table


ANSI Class 150 – 2500
Flow Characteristic
LINEAR EQUAL %
Valve Stem Dia.1 Seat Dia. Max. Cv Max. Cv
Size Stroke 150-600 900-2500 150-600 900-2500 Min Cv ANSI ANSI ANSI ANSI
in. (DN) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) Controllable 150-600 900-2500 150-600 900-2500
2 (50) 1.5 (40) 0.75 (20) 0.75 (20) 2.21 (56) 2.21 (56) 0.6 65 60 55 50

3 (80) 2 (50) 0.75 (20) 0.75 (20) 2.96 (75) 2.96 (75) 0.8 140 130 125 120

4 (100) 2 (50) 0.75 (20) 0.75 (20) 3.80 (97) 3.80 (97) 0.9 210 200 190 180

6 (150) 3 (80) 1.00 (25) 1.00 (25) 5.31 (135) 5.31 (135) 1.4 470 450 420 400

8 (200) 3 (80) 1.25 (32) 1.25 (32) 7.06 (179) 7.06 (179) 1.8 725 700 650 580
4 (100) 830 800 750 720

10 (250) 3 (80) 1.25 (32) 1.5 (40) 10 (250) 8.5 (216) 5.0 1375 1020 1230 850
4 (100) 1550 1160 1390 1040

12 (300) 3 (80) 1.25 (32) 1.5 (40) 11.9 (301) 10 (250) 6.0 1740 1300 1560 1080
4 (100) 2020 1470 1790 1320

14 (350) 3 (80) 1.25 (32) 1.5 (40) 12.5 (318) 11.86 (301) 7.5 — 1650 — 1370
4 (100) — 1950 — 1750

16 (400) 3 (80) 1.25 (32) 1.5 (40) 14.7 (373) 12.5 (318) 7.5 2500 1850 2250 1530
4 (100) 3100 2200 2750 1980

1. Stem diameter for T2 trim is 1/2" for 2-4" sizes and 3/4" for 6" & 8" sizes.

- 62 -
AEROFLOW CV TABLES
LES-SONIC CAGE THROTTLING Cv Table
Flow Characteristic - LINEAR

LINEAR
∆P/P1
Valve Stem Dia.1 Seat Dia. ≤ 0.6 >0.6 ≤ 0.8 >0.8 ≤ 0.992
Size Stroke 150-600 900-2500 150-600 900-2500 Min. Cv 150- 900- 150- 900- 150- 900-
in (DN) in (mm) in (mm) in (mm) in (mm) in (mm) Controllable 600 2500 600 2500 600 2500
2 (50) 1.5 (40) 0.75 (20) 0.75 (20) 2.21 (56) 2.21 (56) 0.60 45 45 30 30 15 15
2 (50) 60 60 40 40 23 23
3 (80) 2 (50) 0.75 (20) 0.75 (20) 2.96 (75) 2.96 (75) 0.80 100 100 55 55 30 30
3 (80) 150 150 82 82 45 45
4 (100) 2 (50) 0.75 (20) 0.75 (20) 3.80 (97) 3.80 (97) 0.90 150 150 75 75 40 40
3 (80) 225 225 110 110 60 60
6 (150) 3 (80) 1.00 (25) 1.00 (25) 5.31 (135) 5.31 (135) 1.40 330 330 150 150 85 85
4 (100) 440 440 200 200 115 115
8 (200) 3 (80) 1.25 (32) 1.25 (32) 7.06 (179) 7.06 (179) 1.80 430 430 200 200 110 110
4 (100) 530 530 265 265 150 150
5 (125) 720 720 330 330 180 180
10 (250) 3 (80) 1.25 (32) 1.5 (40) 10 (250) 8.5 (216) 5.02 620 535 280 240 160 135
4 (100) 830 720 375 320 210 180
5 (125) 1030 890 470 400 270 225
12 (300) 3 (80) 1.25 (32) 1.5 (40) 11.9 (301) 10 (250) 6.00 760 620 340 280 190 160
4 (100) 1010 830 450 375 250 210
5 (125) 1270 1030 570 470 315 270
14 (350) 3 (80) 1.25 (32) 1.5 (40) 12.5 (318) 11.86 (301) 7.50 — 760 — 340 — 190
4 (100) — 1010 — 450 — 250
5 (125) — 1270 — 570 — 315
16 (400) 3 (80) 1.25 (32) 1.5 (40) 14.7 (373) 12.5 (318) 7.50 920 790 410 350 230 200
4 (100) 1230 1060 550 465 310 270
5 (125) 1540 1320 690 585 390 335
1. Stem diameter for T2 trim is 1/2" for 2-4" sizes and 3/4" for 6" size.
2. For ratios above .9 consult Leslie Controls.

LES-CAV CAGE THROTTLING (Single/Multi - Stage) Cv Table


Flow Characteristic - LINEAR
Valve Stem Dia.1 Seat Dia. ANSI 150-600 ANSI 900-2500
Size Stroke 150-600 900-2500 150-600 900-2500 Min.Cv
in (DN) in (mm) in (mm) in (mm) in (mm) in (mm) Contr. CAV I CAV II CAV III CAV IV CAV V CAV I CAV II CAV III CAV IV CAV V
2 (50) 1.5 (40) .75 (20) .75 (20) 2.2 (56) 2.2 (56) 0.6 40 15 9 6 4 40 15 9 6 4
2 (50) 52 20 12 7 6 52 20 12 7 6
3 (80) 2 (50) .75 (20) .75 (20) 2.96 (75) 2.96 (75) 0.8 75 28 18 10 8 75 28 18 10 8
3 (80) 110 48 28 14 12 110 48 28 14 12
4 (100) 2 (50) .75 (20) .75 (20) 3.80 (97) 3.80 (97) 0.9 95 45 27 18 13 95 45 27 18 13
3 (80) 140 68 41 26 22 140 68 41 26 22
6 (150) 3 (80) 1 (25) 1 (25) 5.31 (135) 5.31 (135) 1.4 200 110 58 38 28 200 110 58 38 28
4 (100) 265 145 80 50 38 265 145 80 50 38
8 (200) 3 (80) 1.25 (32) 1.25 (32) 7.06 (179) 7.06 (179) 1.8 270 150 106 58 50 270 150 106 58 50
4 (100) 340 225 140 87 75 340 225 140 87 75
5 (125) 430 300 180 116 100 430 300 180 116 100
10 (250) 3 (80) 1.25 (32) 1.5 (40) 10 (250) 8.5 (216) 5.0 370 210 150 81 70 320 185 127 70 60
4 (100) 490 280 195 122 106 425 250 168 104 90
5 (125) 620 350 250 162 140 530 310 215 140 120
12 (300) 3 (80) 1.25 (32) 1.5 (40) 11.9 (301) 10 (250) 5.6 450 250 178 97 84 370 210 150 81 70
4 (100) 600 330 235 146 126 490 280 195 122 106
5 (125) 750 415 300 195 168 620 350 250 162 140
14 (350) 3 (80) 1.25 (32) 1.5 (40) 12.5 (318) 11.86 (301) 6.6 345 250 178 97 84 345 250 178 97 84
4 (100) 580 330 235 146 126 580 330 235 146 126
5 (125) 730 415 300 195 168 730 415 300 195 168
16 (400) 3 (80) 1.25 (32) 1.5 (40) 14.7 (373) 12.5 (318) 6.9 550 310 220 120 104 470 260 187 103 88
4 (100) 730 410 290 180 150 630 345 248 154 133
5 (125) 910 515 370 240 200 780 430 320 205 177

- 63 -
AEROFLOW CV & FLOW COEFFICIENT TABLES
Mini-P (3-STAGE) PLUG THROTTLING Cv Table
LINEAR

Good for Cavitation but not for Flashing


Flow Characteristic - LINEAR
Valve Stem Seat
Size Stroke Dia. Dia.
in/DN in/mm in/mm in/mm Min Cv Max Cv
1/25 1.2
or 0.75/20 0.75/20 0.875/22 0.08 3
1.5/40 5

MICROTAPER® PLUG THROTTLING Cv Table


Good for Flashing but not for Cavitation
Flow Characteristic - LINEAR
Valve Stem Seat
Size Stroke Dia. Dia.
in/DN in/mm in/mm in/mm Min Cv Max Cv
0.375/9.5 0.01 0.3
0.375/9.5 0.01 0.6
1/25
0.375/9.5 0.01 1.2
or 1/25 0.75/20
0.50/13 0.013 2.1
1.5/40
.75/19 0.02 4.8
1.0/25 0.03 8.5

Flow Coefficients Globe vs. Angle


Flow Coefficients/Allowable ∆P for Aeroflow Anti-Cav Trim Configurations
Globe Angle Maximum Pressure
FL XT FL XT Differential psi (bar)1
Unbalanced Plug Throttling (Flow under seat) 0.92 0.80 0.90 0.76 N/A
Unbalanced Plug Throttling (Flow over seat)2 0.75 0.50 0.65 0.40 N/A
Cage (UBC/LT/HT) Throttling (Flow under seat) 0.88 0.76 0.85 0.72 N/A
Cage (LT/HT/PB/T2) Throttling (Flow over seat) 0.85 0.72 0.83 0.70 N/A
Les-Sonic (Flow under seat) N/A 0.68 N/A 0.64 N/A
Les-Sonic (Flow over seat) N/A 0.66 N/A 0.62 N/A
Les-Cav I (Flow over seat) 0.94 N/A 0.92 N/A 400 (27.6)
Les-Cav II (Flow over seat) 0.96 N/A 0.94 N/A 750 (51.7)
Les-Cav III (Flow over seat) 0.98 N/A 0.96 N/A 2000 (138)
Les-Cav IV (Flow over seat) 0.99 N/A 0.97 N/A 3000 (207)
Les-Cav V (Flow over seat) 0.99 N/A 0.98 N/A 4000 (276)
MicroTaper® (Flow under seat) 0.92 0.80 0.90 0.78 N/A
MicroTaper® (Flow over seat) 0.70 0.45 0.60 0.35 N/A
Mini-P (Flow under seat) 0.98 N/A 0.96 N/A 2000 (138)

1. Other trim Configurations Maximum Pressure Differential will be limited on Allowable Liquid
Velocities. These values are rules of thumb and may vary with specific customer conditions.
2. Consult factory for limitations of using unbalanced trim to flow over seat.

- 64 -
STANDARD PACKING CONFIGURATIONS
LAMINATED GRAPHITE (LG)
Precision die-cut laminated graphite rings provide a reliable, tight
stem seal up to operating temperatures of 1050ºF (565ºC).
BRAIDED TEFLON GRAPHITE (BTG)

LINEAR
Split rings allow packing replacement without removal of actuator.
Graphite impregnated PTFE provides 500ºF (260ºC) service temper-
ature, better “memory” and sealing than pure PTFE rings, lowered
stem hysteresis, and is ideal for fluids that contain suspended parti-
cles.
LG BTG DOUBLE PTFE V-RING
Also available.

Leslie Controls PROTECTS YOUR VALVE INVESTMENT


with a leak free WedgeSeal packing system
from Chesterton00
COMMON AIR OPERATED VALVE CONCERNS
WedgeSeal™ Packing System VALVE LEAKAGE
• Frequent stem actuation can cause loss of packing
The WedgeSeal packing gland load that leads to stem leakage.
system reduces stem
friction and gland loads. • PTFE v-rings will relax and wear in service. Braided
The WedgeSeal arrange- packing will consolidate in-service and lose gland load.
ment transfers gland POOR VALVE RESPONSIVENESS
force with predictable • Control valve responsiveness is critical to process
precision. Patented, quality and control. High packing friction from graphite
WedgeSeal sealing rings rings causes poor step response and process control,
are available in low fric- especially in lower temperature valves.
tion, PTFE mesh over • Friction causes valves to constantly hunt for the
graphite construction or correct position resulting in continuous stem actuation.
pure graphite. Both VARIATIONS IN VALVE PERFORMANCE
1/4" Thick Leslie
meet API 589 Fire • Variations in packing friction can cause unit start-up
Packing Box Ring Test requirements. problems. Inconsistent gland loading and sealing
system designs can be factors.
CHESTERTON WedgeSeal™ SOLUTIONS
FREQUENT VALVE ADJUSTMENTS
MAXIMUM SEALABILITY • Tightening packing glands in the field to reduce valve
• Transfers gland force efficiently to enhance sealing leakage can be all too common. Once tightened,
uncontrolled packing friction can limit operability.
• Packing volume loss and relaxation is minimized
with low PTFE content POOR VALVE RELIABILITY
• Poor control valve reliability can have a dramatic affect
VALVE RESPONSIVENESS on production costs, even before it is removed from
• Combines the friction characteristics of PTFE service. Removing control valves from service can be
with the physical characteristics of graphite for expensive.
unmatched performance. Step response below
1% is typical to maximize process control
• Minimizes valve hunting and improves process
quality and production yields
CONSISTENT PERFORMANCE
• Engineered sets ensure valve performance and
repeatablility
• Wiper rings are available for abrasive service 1724E PTFE
MAINTENANCE FREE Sealing System
WedgeSeal Low overall for maximum
• Valve live loading stores 800% more elastic energy Packing System PTFE content chemical
to maintain optimized gland load for temperatures increases compatability
• Frequent valve adjustments are eliminated greater than thermal stability
230ºC (450ºF)

- 65 -
AEROFLOW PARTS - UNBALANCED
MicroTaper® Mini-P Multi-Stage
Trim Plug ThrottlingTrim
LINEAR

3
2

2
5 5 5

6 4 6

17 3 17
2

16

15

17

➡ ➡ Load Ring Detail


Unbalanced Plug & VP 900-2500
(Cage Throttling 4" Valve Size and Up)
Throttling Trim 17 900-2500 Class

6
5
Body/bonnet Module
shown with
2
Unbalanced Cage 8
3 Throttling Trim 9
5
7
6

Packing Detail

12
Packing Detail 11 Packing Detail
w/BTG Packing 13
w/Laminated
10
Graphite Packing
14

- 66 -
AEROFLOW MATERIAL SPECIFICATION - UNBALANCED
Item Description Material Material Specification
1 Body/Bonnet Carbon Steel ASTM A-216 GR WCB

LINEAR
Stainless Steel ASTM A-351 GR CF8M
Chrome-moly Steel ASTM A-217 GR WC9
2 Valve Plug Stainless Steel AISI SST 420
Mini P Trim only 1 3-8 MO ASTM A-564
Microtaper Trim only Stainless Steel AISI SST 431
3 Valve Stem Nitronic 60 ASTM A-276
4 Piston Ring Stellite Stellite #25
1
5 Cage Stainless Steel AISI SST 440
6 Seat Ring Stainless Steel AISI SST 440C
7 Load Ring Stainless Steel 400 Series
8 Load Screws Stainless Steel ASTM F880
9 Retaining Ring Stainless Steel AISI SST 302
10 Packing Follower Stainless Steel AISI SST 303
11 Packing Flange Stainless Steel AISI 1144CF
12 Hex Nut Stainless Steel ASTM A-194 GR4
13 Studs Alloy Steel ASTM A-193 B16
14 Packing BTG or Laminated Graphite
15 Hex Nut Alloy Steel ASTM A-194 GR7
Alloy Steel (WCB body) ASTM A-194 GR2
16 Stud Alloy Steel ASTM A-193 B16
Alloy Steel (WCB body) ASTM A-193 GR7
17 Gasket Graphite Inconel 600
NOTE:
INCONEL® is a trademark of the Inco Family of Companies
MICROTAPER® is a registered trademark of Leslie Controls, Inc.
STELLITE® is a trademark of Stoody Deloro Stellite, Inc.
NITRONIC 60® is a trademark of Armco, Inc.
NACE Material available upon request

1. Included in all other trim modules unless otherwise listed

- 67 -
AEROFLOW PARTS - BALANCED
Balanced
T2 Trim High-Temp Trim
LINEAR

3
3
7
4
9
5

6
2
7

9 10
2

10 22
3
21
4

5 23

6 1

8 2

➡ ➡
23

10

Balanced Load Ring Detail


Body/bonnet Module & VP 900-2500
Low-Temp shown with (Cage Throttling 4" Valve Size and Up)
Trim Pilot Balanced Trim 900-2500 Class
9
3
12
13

11 13

15
11
9

10

Packing Detail

18
Packing Detail 17 Packing Detail
w/BTG Packing 19
w/Laminated
16
Graphite Packing
20

- 68 -
AEROFLOW MATERIAL SPECIFICATION - BALANCED
Item Description Material Material Specification
1 Body/Bonnet Carbon Steel ASTM A-216 GR WCB

LINEAR
Stainless Steel ASTM A-351 GR CF8M
Chrome-moly ASTM A-217 GR WC9
2 Valve Plug Stainless Steel AISI 420
3 Valve Stem Nitronic 60 ASTM A-276
4 Pilot Plug Stainless Steel AISI SST 431
5 Socket Head Cap Screw 18-8 Stainless Steel AISI SST 300
6 Pilot Plate Stainless Steel ASTM A-582
7 Piston Ring Stellite Stellite #25
8 Spring Inconel INCO: x 750
1
9 Cage Stainless Steel AISI SST 440
10 Seat Ring Stainless Steel AISI SST 440 C
2
11 Load Ring Stainless Steel 400 Series
12 Load Screws2 Stainless Steel ASTM F880
13 Retaining Ring Stainless Steel AISI SST 302
14 Seal Retainer Stainless Steel ASTM A-240
15 Seal PTFE Fluo 36
16 Packing Follower Stainless Steel AISI SST 303
17 Packing Flange Stainless Steel AISI 1144 CF
18 Hex Nut Stainless Steel ASTM A-194 GR4
19 Studs Alloy Steel A-193 B16
20 Packing BTG or Laminated Graphite
21 Hex Nut Alloy Steel ASTM 194 GR7
Alloy Steel (WCB only) ASTM 194 GR2H
22 Stud Alloy Steel ASTM 193 B16
Alloy Steel (WCB only) ASTM 193 GR7
23 Gasket Graphite Inconel 600
NOTE: Common to all trim modules including Les-Cav/Les-Sonic unless otherwise listed
INCONEL® is a trademark of the Inco Family of Companies
NITRONIC 60® is a trademark of Armco, Inc.
STELLITE® is a trademark of Stoody Deloro Stellite, Inc.
NACE Material available upon request

1. Cage Guided 4" valve size and up (900-2500 Class)


2. Malcolmized® 150-600 Class above 700ºF and 900-4500 Class above 650ºF.

- 69 -
AEROFLOW BODY DIMENSIONS3 - CLASS 150-600
LINEAR

DIMENSIONS IN INCHES Shpg. Info.1 DIMENSIONS IN MILLIMETERS Shpg. Info.1


SIZE A B C2 D WGT. VOL. SIZE A B C2 D WGT. VOL.
ANSI 150/300/600# PN16-100 BWE/SWE ANSI 150/300/600# PN16-100 BWE/SWE
1 81⁄4 41⁄8 8 3 53 lb. 2 ft3 25 210 105 203 76 24 kg 0.1 m3
11⁄2 97⁄8 415⁄16 8 31⁄16 63 lb. 2 ft3 40 251 125 203 78 29 kg 0.1 m3
2 111⁄4 55⁄8 123⁄4 311⁄16 94 lb. 3 ft3 50 286 143 324 94 43 kg 0.1 m3
3 131⁄4 65⁄8 141⁄2 43⁄4 160 lb. 4 ft3 75 337 168 368 121 73 kg 0.2 m3
4 151⁄2 73⁄4 161⁄2 59⁄16 215 lb. 6 ft3 100 394 197 419 141 98 kg 0.2 m3
6 20 10 219⁄16 613⁄16 450 lb. 11 ft3 150 508 254 548 173 204 kg 0.4 m3
8 24 12 24 87⁄8 860 lb. 17 ft3 200 610 305 610 225 390 kg 0.5 m3
10 295⁄8 1413⁄16 183⁄4 93⁄4 1100 lb. 22 ft3 250 752 376 476 248 499 kg 0.6 m3
12 321⁄4 161⁄8 201⁄2 103⁄4 1700 lb. 27 ft3 300 819 410 521 273 771 kg 0.8 m3
16 435⁄8 2113⁄16 231⁄2 123⁄4 3200 lb. 53 ft3 400 1108 552 597 324 1451 kg 1.5 m3
ANSI 150# PN16 Flanged ANSI 150# PN16 Flanged
1 71⁄4 35⁄8 8 3 56 lb. 2 ft3 25 184 92 203 76 25 kg 0.1 m3
11⁄2 83⁄4 43⁄8 8 31⁄16 65 lb. 2 ft3 40 222 111 203 78 29 kg 0.1 m3
2 10 5 123⁄4 311⁄16 95 lb. 3 ft3 50 284 127 324 94 43 kg 0.1 m3
3 113⁄4 57⁄8 141⁄2 43⁄4 155 lb. 4 ft3 75 298 149 368 121 70 kg 0.1 m3
4 137⁄8 615⁄16 161⁄2 59⁄16 230 lb. 5 ft3 100 352 176 419 141 105 kg 0.3 m3
6 173⁄4 87⁄8 219⁄16 613⁄16 505 lb. 9 ft3 150 451 225 548 173 230 kg 0.3 m3
8 213⁄8 105⁄8 24 87⁄8 930 lb. 14 ft3 200 543 270 610 225 423 kg 0.4 m3
10 261⁄2 1413⁄16 183⁄4 93⁄4 1120 lb. 18 ft3 250 673 376 476 248 508 kg 0.5 m3
12 29 161⁄8 201⁄2 103⁄4 1730 lb. 23 ft3 300 737 410 521 273 785 kg 0.7 m3
16 40 2113⁄16 231⁄2 123⁄4 3250 lb. 46 ft3 400 1016 554 597 324 1474 kg 1.3 m3
ANSI 300# PN40-64 Flanged ANSI 300# PN40-64 Flanged
1 73⁄4 37⁄8 8 3 58 lb. 2 ft3 25 197 98 203 76 26 kg 0.1 m3
11⁄2 91⁄4 45⁄8 8 31⁄16 67 lb. 2 ft3 40 235 117 203 78 30 kg 0.1 m3
2 101⁄2 51⁄4 123⁄4 311⁄16 97 lb. 3 ft3 50 267 133 324 94 44 kg 0.1 m3
3 121⁄2 61⁄4 141⁄2 43⁄4 160 lb. 4 ft3 75 311 159 368 121 73 kg 0.1 m3
4 141⁄2 71⁄4 161⁄2 59⁄16 240 lb. 6 ft3 100 368 184 419 141 109 kg 0.2 m3
6 185⁄8 95⁄16 219⁄16 613⁄16 525 lb. 10 ft3 150 473 237 548 173 239 kg 0.3 m3
8 223⁄8 113⁄16 24 87⁄8 950 lb. 15 ft3 200 568 284 610 225 432 kg 0.5 m3
10 277⁄8 1315⁄16 183⁄4 93⁄4 1140 lb. 20 ft3 250 708 354 476 248 517 kg 0.6 m3
12 301⁄2 151⁄4 201⁄2 103⁄4 1760 lb. 25 ft3 300 775 387 521 273 798 kg 0.7 m3
16 415⁄8 2013⁄16 231⁄2 123⁄4 3300 lb. 49 ft3 400 1057 529 597 324 1497 kg 1.4 m3
ANSI 600# PN40-64 Flanged ANSI 600# PN40-64 Flanged
1 81⁄4 41⁄8 8 3 59 lb. 2 ft3 25 210 105 203 76 27 kg 0.1 m3
11⁄2 97⁄8 415⁄16 8 31⁄16 69 lb. 2 ft3 40 251 125 203 78 31 kg 0.1 m3
2 111⁄4 55⁄8 123⁄4 311⁄16 100 lb. 3 ft3 50 286 143 324 100 45 kg 0.1 m3
3 131⁄4 65⁄8 141⁄2 43⁄4 170 lb. 4 ft3 75 337 168 368 121 77 kg 0.2 m3
4 151⁄2 73⁄4 157⁄8 59⁄16 260 lb. 6 ft3 100 394 197 419 141 118kg 0.2 m3
6 20 10 219⁄16 613⁄16 450 lb. 11 ft3 150 508 254 548 173 204 kg 0.3 m3
8 24 12 24 87⁄8 1000 lb. 17 ft3 200 610 305 610 225 390 kg 0.5 m3
10 295⁄8 1413⁄16 183⁄4 93⁄4 1160 lb. 22 ft3 250 752 376 476 248 526 kg 0.6 m3
12 321⁄4 161⁄8 201⁄2 103⁄4 1740 lb. 28 ft3 300 819 410 521 273 812 kg 0.8 m3
16 435⁄8 2113⁄16 231⁄2 123⁄4 3350 lb. 53 ft3 400 1108 554 597 324 1520 kg 1.5 m3
NOTE: DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Request certified drawings for piping layout and construction purposes.
1. Approximate weight and volume (actuator not included)
2. Consult factory for extended travel (C dimension)
3. ISA - 575.15 - 1986
4. Consult Factory for installation dimensions for 150-600 Angle Valves

- 70 -
AEROFLOW BODY DIMENSIONS3 - CLASS 900-2500
DIMENSIONS IN INCHES Shpg. Info.1 DIMENSIONS IN MILLIMETERS Shpg. Info.1
SIZE A B C2 D WGT. VOL. SIZE A B C 2 D WGT. VOL.

LINEAR
ANSI CLASS 900/1500 PN160-250 BWE/SWE ANSI CLASS 900/1500 PN160-250 BWE/SWE
1 11 51⁄2 91⁄2 31⁄8 87 lb. 2 ft3 25 279 140 241 79 39 kg 0.1 m3
11⁄2 13 61⁄2 97⁄8 31⁄2 125 lb. 3 ft3 40 330 165 251 89 57 kg 0.1 m3
2 143⁄4 73⁄8 123⁄4 415⁄16 230 lb. 4 ft3 50 400 200 323 379 104 kg 0.1 m3
3 181⁄8 91⁄16 141⁄2 61⁄8 346 lb. 7 ft3 75 460 251 368 156 157 kg 0.2 m3
4 Glb 207⁄8 113⁄16 153⁄4 73⁄4 484 lb. 10 ft3 100 574 308 400 197 220 kg 0.3 m3
4 Angl N/A 113⁄16 153⁄4 73⁄4 484 lb. 10 ft3 100 574 308 400 197 220 kg 0.3 m3
6 301⁄4 151⁄8 203⁄4 103⁄16 1311 lb. 24 ft3 150 819 384 527 259 595 kg 0.7 m3
8 323⁄4 163⁄8 239⁄16 131⁄4 3069 lb. 34 ft3 200 1022 416 598 337 1392 kg 1.0 m3
10 39 191⁄2 281⁄2 161⁄2 3800 lb. 52 ft3 250 991 495 724 419 1723 kg 1.5 m3
12 441⁄2 221⁄4 301⁄2 193⁄4 5700 lb. 74 ft3 300 1130 565 775 502 2585 kg 2.1 m3
16 56 28 341⁄2 26 8100 lb. 134 ft3 400 1422 711 876 660 3674 kg 3.8 m3
ANSI CLASS 2500 PN400 BWE/SWE ANSI CLASS 2500 PN400 BWE/SWE
1 121⁄2 61⁄4 91⁄2 31⁄8 90 lb. 3 ft3 25 318 159 241 79 41 kg 0.1 m3
11⁄2 141⁄8 71⁄2 97⁄8 31⁄2 130 lb. 3 ft3 40 359 191 251 89 59 kg 0.1 m3
2 153⁄4 77⁄8 123⁄4 4-45⁄16 250 lb. 5 ft3 50 375 187 323 379 113 kg 0.1 m3
3 195⁄8 913⁄16 141⁄2 61⁄8 511 lb. 8 ft3 75 460 230 368 156 232 kg 0.2 m3
4 Glb 225⁄8 121⁄16 153⁄4 8 625 lb. 11 ft3 100 530 301 400 203 283 kg 0.3 m3
4 Angl N/A 115⁄16 153⁄4 8 625 lb. 11 ft3 100 530 301 400 203 283 kg 0.3 m3
6 321⁄4 161⁄8 203⁄4 11 1590 lb. 27 ft3 150 768 409 527 280 721 kg 0.8 m3
8 401⁄4 201⁄8 239⁄16 141⁄4 4059 lb. 51 ft3 200 832 511 598 362 1841 kg 1.4 m3
10 50 25 281⁄2 171⁄2 4900 lb. 84 ft3 250 1270 635 724 419 2223 kg 2.4 m3
12 56 28 301⁄2 203⁄4 7100 lb. 115 ft3 300 1422 711 775 502 3221 kg 3.3 m3
16 Call Call 341⁄2 27 10600 lb. Call ft3 400 Call Call 876 660 4808 kg Call
ANSI CLASS 900 PN160 Flanged (RF and RTJ) ANSI CLASS 900 PN160 Flanged (RF and RTJ)
1 171⁄4 85⁄8 91⁄2 31⁄8 105 lb. 4 ft3 25 438 219 241 79 48 kg 0.1 m3
11⁄2 20 10 97⁄8 31⁄2 150 lb. 6 ft3 40 508 254 251 89 68 kg 0.2 m3
2 231⁄4 115⁄8 123⁄4 415⁄16 280 lb. 9 ft3 50 591 295 323 379 113 kg 0.3 m3
3 265⁄8 135⁄16 141⁄2 61⁄8 551 lb. 13 ft3 75 676 338 368 156 232 kg 0.4 m3
4 Glb 303⁄8 157⁄8 153⁄4 8 680 lb. 18 ft3 100 770 379 400 203 283 kg 0.5 m3
4 Angl N/A 153⁄16 153⁄4 8 680 lb. Call ft3 100 N/A 386 400 203 283 kg Call
6 413⁄4 207⁄8 203⁄4 11 1680 lb. 43 ft3 150 1060 530 527 280 721 kg 1.2 m3
8 461⁄8 231⁄16 239⁄16 141⁄4 4189 lb. 78 ft3 200 1172 586 598 362 1841 kg 1.9 m3
10 54 27 281⁄2 171⁄2 5070 lb. 106 ft3 250 1372 686 724 419 2300 kg 2.8 m3
12 603⁄4 303⁄8 301⁄2 203⁄4 7300 lb. 147 ft3 300 1543 772 775 502 3311 kg 3.8 m3
16 731⁄2 363⁄4 341⁄2 27 10840 lb. 225 ft3 400 1867 933 876 660 4917 kg 6.5 m3
ANSI CLASS 1500 PN250 Flanged (RF and RTJ) ANSI CLASS 1500 PN250 Flanged (RF and RTJ)
1 171⁄4 85⁄8 91⁄2 31⁄8 105 lb. 4 ft3 25 438 219 241 79 48 kg 0.1 m3
11⁄2 20 10 97⁄8 31⁄2 150 lb. 6 ft3 40 508 254 251 89 68 kg 0.2 m3
2 231⁄4 115⁄8 123⁄4 415⁄16 280 lb. 9 ft3 50 591 295 323 379 113 kg 0.3 m3
3 265⁄8 1315⁄16 141⁄2 61⁄8 561 lb. 14 ft3 75 708 354 368 156 254 kg 0.4 m3
4 Glb 311⁄8 161⁄16 153⁄4 8 690 lb. 19 ft3 100 791 389 400 203 313 kg 0.5 m3
4 Angl N/A 159⁄16 153⁄4 8 690 lb. Call 100 N/A 395 400 203 313 kg Call
6 441⁄4 221⁄8 203⁄4 11 1685 lb. 47 ft3 150 1124 562 527 280 764 kg 1.4 m3
8 501⁄8 251⁄16 239⁄16 141⁄4 4199 lb. 90 ft3 200 1273 637 598 362 1905 kg 2.2 m3
10 591⁄2 293⁄4 281⁄2 171⁄2 5100 lb. 126 ft3 250 1511 756 724 419 2313 kg 3.3 m3
12 671⁄4 335⁄8 301⁄2 203⁄4 7360 lb. 176 ft3 300 1708 854 775 502 3338 kg 4.6 m3
16 81 401⁄2 341⁄2 27 10980 lb. 271 ft3 400 2057 1029 876 660 4980 kg 7.7 m3
ANSI CLASS 2500 PN400 Flanged (RF and RTJ) ANSI CLASS 2500 PN400 Flanged (RF and RTJ)
1 20 10 91⁄2 31⁄8 110 lb. 6 ft3 25 508 254 241 79 50 kg 0.2 m3
11⁄2 233⁄8 1111⁄16 97⁄8 31⁄2 160 lb. 8 ft3 40 594 297 251 89 73 kg 0.2 m3
2 261⁄4 131⁄8 123⁄4 415⁄16 290 lb. 12 ft3 50 667 333 323 379 113 kg 0.3 m3
3 333⁄8 1611⁄16 141⁄2 61⁄8 576 lb. 27 ft3 75 848 424 368 156 232 kg 0.6 m3
4 Glb 381⁄8 199⁄16 153⁄4 8 710 lb. 37 ft3 100 968 562 400 203 283 kg 0.8 m3
4 Angl N/A 191⁄16 153⁄4 8 710 lb. Call 100 N/A 484 400 203 283 kg Call
6 541⁄4 271⁄8 203⁄4 11 1745 lb. 73 ft3 150 1378 689 527 280 721 kg 2.0 m3
8 653⁄4 325⁄8 239⁄16 141⁄4 4249 lb. 124 ft3 200 1670 829 598 362 1841 kg 3.6 m3
10 831⁄2 413⁄4 281⁄2 171⁄2 5180 lb. 240 ft3 250 2121 1060 724 419 2350 kg 6.2 m3
12 93 461⁄2 301⁄2 203⁄4 7460 lb. 336 ft3 300 2362 1181 775 502 3384 kg 8.5 m3
16 C/F C/F 341⁄2 27 11120 lb. C/F 400 C/F C/F 876 660 5044 kg C/F
NOTE: DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Request certified drawings for piping layout and construction purposes.

1. Approximate weight and volume (actuator not included)


2. Consult factory for extended travel (C dimension)
3. ISA - 575.15 - 1986
4. Consult Factory for installation dimensions for 150-600 Angle Valves

- 71 -
AEROFLOW ACTUATOR DIMENSIONS
Diaphragm Actuator
LINEAR

DIAPHRAGM ACTUATOR

STANDARD w/Handwheel WEIGHT


B SIZE A B C w/o w/Hndwl
55AFR 161⁄4 1115⁄16 259⁄16 60 65

55AF 185⁄8 1115⁄16 269⁄16 50 55

85AFR 2215⁄32 143⁄4 3113⁄16 120 122

85AF 2511⁄16 143⁄4 335⁄8 96 101


C

Piston Actuator
E
PISTON ACTUATOR
NOM. DA & DASR w/ WEIGHT SHPG. VOL. ft.3
AREA DA DASR DASR HOD
SIZE in2 A B† C D E DA DASR DA DASR

6" 28 16 ⁄2
1
7 ⁄8
7
25 ⁄16
15
35 ⁄8
3
11 ⁄2
1
82 122 2.1 2.8

10" 78 1711⁄16 101⁄2 337⁄8 453⁄4 1213⁄16 132 172 3.7 5

13" 130 26 153⁄4 475⁄16 5913⁄16 133⁄16 232 352 8.1 11.8

16" 201 243⁄4 19 421⁄16 5113⁄16 1411⁄16 295 425 9.7 14

B D 20" 314 243⁄4 23 421⁄16 5113⁄16 1411⁄16 415 535 13.8 20


DA - Double Acting
DASR - Double Acting w/Spring Return
C † Corner to corner dimension not shown.

A Leslie’s unique optional Manual Hydraulic Override System


(HOD), shown above, assures easy, accurate manual valve
positioning using a hydraulic hand pump to position the
valve plug in 1/8" increments per pump stroke.

- 72 -
AEROFLOW SPECIFICATION
Valve Body Actuators
1.1.1 Body should have integrally cast flow control vanes in 2.1.1 Actuator should be designed in a steel or composite
the inlet, outlet and body gallery to reduce turbulence construction that is rated for 150 psig working pressure.

LINEAR
and allow maximum Cv/Size ratios. 2.1.2 Air failure spring should be mounted outside air cylinder
1.1.2 Body should be designed with pressure taps on the to minimize residual air volume.
inlet and outlet side so that adjacent piping penetration 2.1.3 Spring cartridge should be mounted so that accessi-
points are not needed. bility for reversing failure modes is easily accomplished.
1.1.3 Globe and angle body configurations should be 2.1.4 Actuator/spring assembly shall be designed to
designed so that trim modules are fully interchangeable. provide a low center of gravity for vibration and
1.1.4 High pressure body designs (900-2500#) should allow seismic resistance.
for machining to accept an outlet pipe nominally one
size larger than the valve body size.

Valve Trim
1.2.1 Pilot balanced trim to have capability to shutoff to ANSI
Class Vl or Zero (cc/min) Leakage utilizing metal-to-
metal seats.
1.2.2 Valve plug should be designed with a three stage
labyrinth style plug tip.
1.2.3 Trim design should allow for reduction down to a 0.2
factor of full Cv, without changing the original plug or
seat ring
1.2.4 Cage design should allow for modification of flow win
dow for a desired flow characteristic without changing
plug assembly.
1.2.5 Unbalanced designs should allow for reduction of Cv
without reducing seat ring diameter.

Steam Conditioning
Station
Leslie offers it’s unique Aeroflow
pressure reducing valve in combin-
ation with a state of the art, variable
area, mechanically atomized desuper-
heating system. This combination
system meets today’s stringent require-
ments for control and turndown with-
out the temperature stress problems
associated with combination units.
We offer complete fabricated systems
that include either Globe or Angle body
PRV designs with noise attenuation
plates (as required), customized trim
selection and desuperheating equip-
ment.

- 73 -
AEROFLOW ACCESSORIES
LINEAR

Siemen’s Series 760 Positioners


• Pneumatic: Model 760P
• Electropneumatic: Model 760E
• Optional internal limit switches
• Optional valve position transmission

Other Positioners
• PMV Series 1200, 2000 and P5
• ABB TZID-C
• SMAR FY302 Fieldbus
• Siemens PS2
• Bailey AV Series

Process Controllers
• Electropneumatic: PMC-1
• Pneumatic: PDAP/PRAP

Solenoid Valves
• ASCO 8320G174 is standard
• Other Asco models, Versa, Skinner, as required

Electric Actuators
• Jordan

Electrohydraulic Actuators
• Rexa L & T Series

Limit Switches
• Westlock
• National Acme (NAMCO)
• Honeywell (Micro)
• GO Proximity Switches

Noise Reduction Devices


• Noise Suppressor
• Les-Sonic Silencing Orifice

Air Regulators Other Options


• ASG-1 • Handwheels
• AFG-2 • Hydraulic Manual
• Bellofram Type 50 Override System
• Control Air Type 300 • Limit Stops
• Special Connections
Instruments - Socketweld
• Lockup Valves - Buttweld
• S-Transfer Valve - Stub Ends
- Pipe Reducers
- Smooth Flange Faces
- Ring Type Joints

- 74 -
AEROFLOW Linear Valve Specification Form
Project/Job _________________________________________ Data Sheet ________ of ________
Unit/Customer ______________________________________ Spec _____________________________________
12501 Telecom Drive · Tampa, Florida 33637
(813) 978-1000 · FAX: (813)-978-0984 P.O./LCO File #______________________________________ Tag_______________________________________

LINEAR
Item _______________________________________________ Dwg______________________________________
CONTROL VALVE Contract____________________________________________ Service ___________________________________
SPEC SHEET MFR Serial# ________________________________________

Fluid ❏ Steam ❏ Water ❏ Gas______________ ❏ Liquid______________ Crit Pres PC


Service Conditions Max. Flow Norm. Flow Min. Flow Shut-off Pressure
Flow ❏ #/hr ❏ gpm ❏ scfh ❏ _________
Inlet Pressure ❏ psig ❏ psia ❏ _________
Outlet Pressure ❏ psig ❏ psia ❏ _________
Temperature ❏ °C ❏ °F ____________
Max Press/Temperature:____________ /____________
Density/MW/SG __________/__________/___________
Viscosity _________CP
Vapor Pressure ❏ psia ❏ _________
Required Cv _____________ Noise (dBA) Allowable______________
Line Actuator
Pipe Size/Sch.In ______________ /Sch ________________ *Type ❏ DA ❏ SR ❏ DASR
Pipe Size/Sch. Out ____________/Sch ________________ ❏ Diaph ❏ EHA ❏ Electr. ❏ Other
Pipe Line Insulation ____________ in. ________________ *Mfr/Model ______________/_______________
Valve Body and Bonnet *Size/Eff Area ❏ 6”/28 in2 ❏ 10”/80 in2 ❏ 13”/130 in2
Type ❏ Globe ❏ Angle ❏ 16”/200 in ❏ 20”/300 in2 ❏ Other
2

❏ On/Off ❏ Modulating
*Body Size inches ❏1 ❏ 11⁄2 ❏ 2 ❏3 ❏4
Spring Action/Air Failure ❏ Open ❏ Closed ❏ None
❏6 ❏8 ❏ 10 ❏ 12 ❏ 16
Spring #_______________
ANSI Class ❏ 150 ❏ 300 ❏ 600
*Max. Allowable Press. __________________
❏ 900 ❏ 1500 ❏ 2500 ❏ 4500 *Min. Required Press. ___________________ psig
Design.Press.Temp____________ /______________ Available Air Supply Press. _______________
Mfr./Model: Leslie/Aeroflow Max. ____________ Min. ______________
Body/Bonnet Mat’l ❏ WCB ❏ WC9 ❏ CF8M *Bench Range _______________ psig ❏ N/A
❏ C12A ❏ ______ Act.Orientation ❏ Horiz. ❏ Vert. (Std.)
End Conn Inlet/Outlet Override Type ❏ Hyd. Overide ❏ None
❏ Flg RF ❏ Thd ❏ RTJ Air Failure Valve ❏ Opens ❏ Closes ❏ Last
❏ SWE ❏ BWE/Sch ______ Tubing ❏ SST ❏ Copper
❏ In BWE/Sch ______ ❏ In SWE ______ ❏ 3/8” ❏ 1/2” ❏ ______
❏ Out BWE/Sch ______ ❏ Out SWE ______ Data Tag: ❏ Brass ❏ SST
❏ In Stubs/Sch ______ Length (in.) ______ Solenoid ❏ Asco/8320G174 ❏ None
❏ Other Mfgr/Model ____________ /_____________
❏ Out Stub/Sch ______ Length (in.) ______
Positioner
❏ Exp ______ x ______ In/Sch ______
Input Signal ❏ 3-15 psi ❏ 4-20 mA ❏ __________
❏ Exp ______ x ______ Out/Sch ______
*Type ❏ Pneu. ❏ I/P ❏ None
Flg. Face Finish ______RMS ❏ Std. (125-500) *Mfr./Model____________ /_____________
End Ext/Mat’l. ________________________________ *On Incr. Signal Output ❏ Incr. ❏ Decr.
*Flow ❏ Over Seat ❏ Under Seat Gauges ❏ Yes ❏ No, By-Pass ❏ Yes ❏ No
*Type Bonnet ❏ Std *Cam Charact. ❏ Linear ❏ =% ❏ Sq.Root
*Packing Mat’l ❏ LG ❏ BTG ❏ DTFE Switch
❏ Live Loaded ❏ Other *Type ❏ Mech ❏ Prox ❏ Other
Trim *Mfr./Model____________ /_____________
*Type ❏ UBP ❏ MT ❏ Mini-P ❏ UBC Contacts/Rating ❏ SPDT ❏ DPDT
❏ BH ❏ BL ❏ PB ❏ T2 Actuation points: ❏ Both ❏ Open ❏ Closed
Les-Sonic Cage ❏ Yes NEMA Class 1,4, & 13
Les-Cav ❏ I ❏ II ❏ III ❏ IV ❏ V Airset
*Mfr./Model: Leslie/ ❏ AFG-2 ❏ ASG-1 ❏ None
C3 ❏ Yes
*Set Press. ___________PSIG _____________ /____________
*Characteristic ❏ Linear ❏ =% ❏ QO ❏ Custom
Filter ❏ Yes ❏ No Gauge ❏ Yes ❏ No
Travel ❏ Std. ❏ Ext ❏ Max
Range: Max ❏ 30psi ❏ 60 psi ❏ 100psi ❏ 150psi
*Rated Cv _________% Max._________ Cv = ______________ Test *Hydro Pressure
❏ Malcomizing (150-600 CL > 700ºF, 900-4500 CL > 650ºF) ANSI/FCI Leakage Class ❏ III ❏ IV ❏ V
Special ACC NEC Class Group Div. ❏ VI ❏ Zero CC/min
QUESTIONS? CALL LESLIE CONTROLS @ (813) 978-1000 PLEASE FAX COMPLETED FORM TO: (813) 977-0174