200ah 12V

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Jiangsu Oliter Energy Technology Co.

,Ltd was founded in 1998,covered 42,000M2,annual throughput


reaches 750000KVAH.Over the years ,Oliter is focusing on the integration of R&D,production,Marketing and
application of VRLA,Gel battery,Lithium battery.By the support of South China Normal University,Xi’An
JiaoTong University and Other scientific research institutes,Oliter has built up the post-doctoral
workstations.Till now,Oliter has achieved 7 series,more than 100 models of batteries.Oliter has became the
largest production base of solar energy storage battery in northern Jiangsu.

LCPA 200-12 LEAD ACID BATTERY


Features
“Oliter” battery
,Maintenance free and
easy to use, Contemporary
advanced technology
research and development
of new high-performance
batteries,It can be widely
used in solar energy,
wind energy,
telecommunication
systems,off-grid systems
,UPS and other
fields.The designed life
for the battery could be
eight years up for float
use.

Technology data Certificate


Capacity Max Max Self- Recommended ISO9001
Reted ISO14001
(10hr,1.8 Weight Discharge Charge Discharge Using Cover Material
Voltage 0V/Cell) Current (25℃) Temperature CE
Current
CGC
30I 10A
12V 200Ah 56Kg ≤0.25C 10 <3%/month 15℃~25℃ ABS TLC
(3min)
High and New Technology
Charge Voltage Capacity Products Certification
Using Temperature Charge Mode(25℃) Cycle life Affected by
(25℃) Temperature
Standards:
Float Charge:2.275±0.025V/Cell 100%DOD GB/T 19638.2-2005
Float Charge:
Discharge:-45℃~50℃
13.5V-13.8V
Temperature Compensation 490times 105 % @ 40℃ YD/T799-2002
Charge: -20℃~45℃ Coefficient :±3 mV/Cell ℃ 50%DOD 85 % @ 0℃
Average Charge: JISC8704-2:1999
Storage: -30℃~40℃ Cycle Charge:2.45±0.05V/Cell 1250 times 60 % @ -20℃
14.4V-14.7V Temperature Compensation 30%DOD
Coefficient: ±5 mV/Cell ℃ 2150times
Contact
Different discharge time at different terminal Voltage,discharge time(Amps,25) Telephone:
Constant current discharge coefficient(25℃,A) +86-0514-80950888
Terminal
Voltage
1H 3H 5H 10H 20H 50H 100H 120H 240H Fax:
(v/Cell)
+86-0514-84472801
1.7 109.01 49.56 33.12 21.36 11.03 4.64 2.52 2.23 1.18 E-mail:
1.75 106.84 49.05 32.53 21.06 10.78 4.46 2.35 2.08 1.09 [email protected]
1.8 104.70 48.59 32.03 20.53 10.52 4.31 2.26 1.94 1.04 Web:
1.85 100.51 48.31 31.41 19.68 10.01 4.13 2.11 1.82 0.94 http://www.oliter.com
1.9 96.50 47.89 30.95 19.27 9.84 4.01 2.04 1.74 0.89
1.95 92.26 46.93 30.30 18.20 9.15 3.72 1.93 1.66 0.85

- 1/2 -
Performance characteristics
Temperature and Service life Discharge characteristics at Various Rates (25℃/77℉)
Service Life (years)

10

Discharge voltage
13.5
7.5
13.0

12.5
5
12.0

2.5 11.5
(V)
11.0
0 10.5
-10 0 10 20 30 40 50 60 0.01 0.05 0.1 0.2 0.5 1 2 5 10 20 50
Temperature( ) Discharge Time (h)

Temperature and discharge capacity


self discharge parameters characteristics
140
Capacity (%C10)

Effective capacity (%)

100
120

100 80

80 5℃
60
60
40℃ 30℃ 20℃
40 40

0
20 0 2 4 6 8 10 12 14 16 18 20
-40 -30 -20 -10 0 10 20 30 40 50 60
Temperature (℃) Storage capacity (month )

Constant-potential charge Cycle Service Life (25℃/77℉)


Current Voltage
(I10A) (V/ cell ) Capacity
(%) 100%
1.8 2.40 90%
Battery Voltage
Charge Current 80%
1.5 2.30 100 70%
Charge Quantity
60%
1.2 2.20 75
50%
DOD(%)

40%
0.9 2.10 50
50% DOD 30%
100% DOD 20%
0.6 2.00 25
10%

0.3 1.90 0 0%
0 500 1000 1500 2000 2500 3000 3500

0 1.80 Number of Cycles (times)


0 4 8 12 16 24 32 40 48
Time (h)

- 2/2 -

You might also like